Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 59
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Appl Radiat Isot ; 204: 111109, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38029636

RESUMO

The goal of this study is to provide a benchmark for the use of Monte Carlo simulation when applied to coincidence summing corrections. The examples are based on simple geometries: two types of germanium detectors and four kinds of sources, to mimic eight typical measurement conditions. The coincidence corrective factors are computed for four radionuclides. The exercise input files and calculation results with practical recommendations are made available for new users on a dedicated webpage.

2.
Appl Radiat Isot ; 194: 110680, 2023 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-36696752

RESUMO

Recycling and conventional reuse of lead materials and structures originating from controlled areas in nuclear facilities rely on historical knowledge and well selected characterization procedures. At the SCK•CEN, one of these procedures involves performing high-resolution gamma-ray spectrometry measurements on several cylindrical shaped test samples (50 mm diameter and approximately 5 mm thickness), obtained during the lead melting campaigns. The high density (11.3 g/cm³) of these samples is a challenge for radionuclide analysis by gamma-ray spectrometry since no such calibration sources nor reference materials are available. We used the efficiency transfer procedure, relying on regular standard sources available in our laboratory, to set up calibrations for this specific counting geometry. The method proves to be fit for purpose.

3.
Appl Radiat Isot ; 192: 110607, 2023 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-36495787

RESUMO

Gamma spectrometric measurements to determine the isotopic composition and total uranium mass in UO2 pellets (D = 7.5 mm; H = 3.5 mm, ρ = 10 g/cm3) were carried out. The required efficiency curve was obtained by applying the efficiency transfer method from a calibration standard (D = 65 mm; H = 20 mm) of a slightly acidified water solution. The average isotopic composition of ten UO2 pellets was consistent with values of natural uranium given by IUPAC. The average relative bias for the 235U/238U amount ratio was -0.73% using the 1001 keV gamma line for 238U and 0.50% using the 63 keV gamma line (186 keV was always used for 235U). For the total uranium mass, the mean deviation as compared to mass determinations using a balance was 5.5% using the 1001 keV gamma line for 238U and 4.3% using the 63 keV gamma line.


Assuntos
Urânio , Urânio/análise , Espectrometria gama/métodos , Raios gama
4.
Appl Radiat Isot ; 155: 108921, 2020 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-31629294

RESUMO

An internal consistency test of the calculation of coincidence-summing correction factors FC for volume sources is presented. The test is based on exact equations relating the values of FC calculated for three ideal measurement configurations. The test is applied to a number of 33 sets of FC values sent by 21 teams. Most sets passed the test, but not the results obtained using the quasi-point source approximation; in the latter case the test qualitatively indicated the magnitude of the bias of FC.

5.
Appl Radiat Isot ; 109: 482-486, 2016 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-26651169

RESUMO

The aim of this study was to check for equivalence of computer codes that are capable of performing calculations of true coincidence summing (TCS) correction factors. All calculations were performed for a set of well-defined detector parameters, sample parameters and decay scheme data. The studied geometry was a point source of (133)Ba positioned directly on the detector window of a low-energy (n-type) detector. Good agreement was established between the TCS correction factors computed by the different codes.

6.
Appl Radiat Isot ; 109: 547-550, 2016 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-26688363

RESUMO

We present a numerical fitting method for transmission data that outputs an equivalent sample composition. This output is used as input to a generalised efficiency transfer model based on the EFFTRAN software integrated in a LIMS. The procedural concept allows choosing between efficiency transfer with a predefined sample composition or with an experimentally determined composition based on a transmission measurement. The method can be used for simultaneous quantification of low-energy gamma emitters like (210)Pb, (241)Am, (234)Th in typical environmental samples.

7.
Appl Radiat Isot ; 87: 356-60, 2014 May.
Artigo em Inglês | MEDLINE | ID: mdl-24326317

RESUMO

Any approach to efficiency calibration of HPGe detectors sensitive to low-energy gamma-rays and X-rays has to deal with true coincidence summing. We developed a method based on the integration of the EFFTRAN code into the commercial Genie2K™ gamma-ray spectrometry software. EFFTRAN's role is to compute true coincidence summing corrections and to obtain satisfactory results for detectors sensitive to X-rays. EFFTRAN had to be upgraded to include a full simulation of the emission of X-rays. In this manner, efficiency calibrations were successfully set up for BeGe and XtRa detectors.

8.
Appl Radiat Isot ; 87: 425-8, 2014 May.
Artigo em Inglês | MEDLINE | ID: mdl-24332338

RESUMO

We developed a Microsoft(®) Access-based LIMS (Laboratory Information and Management Systems), γ-LIMS, for the management of our gamma-spectrometry laboratory, in which thousands of routine, but high-quality analyses are performed each year. This paper explains the main features of the γ-LIMS and puts special attention on the interfacing methods and solutions for using the Genie™2000 spectrometry software in conjunction with the EFFTRAN package, which serves for efficiency transfer calculations, coincidence summing corrections and a procedure for uncertainty estimation.

9.
Appl Radiat Isot ; 87: 336-41, 2014 May.
Artigo em Inglês | MEDLINE | ID: mdl-24332343

RESUMO

The aim of the study was to check for equivalence of computer codes that can perform calculations of true coincidence summing correction factors. All calculations were performed for a set of well-defined detector and sample parameters, without any reference to empirical data. For a p-type detector model the application of different codes resulted in satisfactory agreement in the calculated correction factors. For high-efficiency geometries in combination with an n-type detector and a radionuclide emitting abundant X-rays the results were scattered.

10.
Appl Radiat Isot ; 70(9): 2112-8, 2012 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-22445105

RESUMO

The second part of an intercomparison of the coincidence summing correction methods is presented. This exercise concerned three volume sources, filled with liquid radioactive solution. The same experimental spectra, decay scheme and photon emission intensities were used by all the participants. The results were expressed as coincidence summing corrective factors for several energies of (152)Eu and (134)Cs, and different source-to-detector distances. They are presented and discussed.


Assuntos
Algoritmos , Artefatos , Radioisótopos/análise , Radioisótopos/normas , Radiometria/métodos , Radiometria/normas , Espectrometria gama/métodos , Meia-Vida , Internacionalidade , Doses de Radiação , Radioisótopos/química , Padrões de Referência , Valores de Referência
11.
Appl Radiat Isot ; 68(7-8): 1407-12; discussion 1412, 2010.
Artigo em Inglês | MEDLINE | ID: mdl-20117939

RESUMO

A comparison of the coincidence summing correction methods is presented. Since there are several ways for computing these corrections, each method has advantages and drawbacks that could be compared. This part of the comparison was restricted to point sources. The same experimental spectra, decay scheme and photon emission intensities were used by all the participants. The results were expressed as coincidence summing correction factors for several energies of (152)Eu and (134)Cs, and three source-to-detector distances. They are presented and discussed.

12.
Appl Radiat Isot ; 68(7-8): 1226-30, 2010.
Artigo em Inglês | MEDLINE | ID: mdl-19962906

RESUMO

This experiment aimed at studying a technique to measure the leakage of charged particles from a fusion plasma. The activity induced in samples of various materials placed on a special holder inside a Tokamak was measured using ultra low-level gamma-ray spectrometry (ULGS) performed in three underground laboratories. In total, 27 radionuclides were detected in this experiment. Seven of these radionuclides were mainly produced by proton interactions. For two of them it was possible to determine their angular distribution.

13.
Appl Radiat Isot ; 68(2): 355-9, 2010 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-19892558

RESUMO

Four general Monte Carlo codes (GEANT3, PENELOPE, MCNP and EGS4) and five dedicated packages for efficiency determination in gamma-ray spectrometry (ANGLE, DETEFF, GESPECOR, ETNA and EFFTRAN) were checked for equivalence by applying them to the calculation of efficiency transfer (ET) factors for a set of well-defined sample parameters, detector parameters and energies typically encountered in environmental radioactivity measurements. The differences between the results of the different codes never exceeded a few percent and were lower than 2% in the majority of cases.


Assuntos
Algoritmos , Radiometria/instrumentação , Radiometria/métodos , Software , Desenho de Equipamento , Análise de Falha de Equipamento , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
14.
Appl Radiat Isot ; 67(10): 1952-6, 2009 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-19647443

RESUMO

Five different numerical algorithms used for calculating coincidence summing corrections (CSCs) in HPGe gamma-spectrometry in case of complex radionuclide decay schemes were tested for their equivalence. Simulated point-source detection geometries and efficiency curves have been used to calculate and compare counting rates as well as CSCs of (133)Ba, (134)Cs and (152)Eu of 1MBq sources. Contributions of one X-ray per radionuclide were included. The algorithms were found to give identical results within their respective presuppositions.

15.
Appl Radiat Isot ; 67(5): 716-8, 2009 May.
Artigo em Inglês | MEDLINE | ID: mdl-19230683

RESUMO

A new approach to spectrum analysis in gamma-ray spectrometry has recently been proposed, based on channel-by-channel matching of the measured spectrum with calculated synthetic spectra. In this paper, verification of the new method against experimental data and a comparison with the standard approach to the analysis of HPGe spectra is presented.


Assuntos
Simulação por Computador , Espectrometria gama/métodos , Algoritmos , Modelos Teóricos
16.
Appl Radiat Isot ; 67(1): 160-3, 2009 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-18829336

RESUMO

The sum-peak method was successfully applied to the determination of the activity of extended (60)Co sources measured on a HPGe detector. Monte Carlo simulations were used to account for the effects of the spatial variation of the efficiency across the sample volume and for the angular correlations between the emitted gamma rays. The determined activities agree with the reference values within a range of 1.0%.


Assuntos
Radioisótopos de Cobalto/análise , Radioisótopos de Cobalto/normas , Métodos , Método de Monte Carlo , Padrões de Referência
17.
Appl Radiat Isot ; 66(6-7): 764-8, 2008.
Artigo em Inglês | MEDLINE | ID: mdl-18359236

RESUMO

In an intercomparison exercise, the Monte Carlo codes most commonly used in gamma-ray spectrometry today were compared with each other in order to gauge the differences between them in terms of typical applications. No reference was made to experimental data; instead, the aim was to confront the codes with each other, as they were applied to the calculation of full-energy-peak and total efficiencies. Surprising differences between the results of different codes were revealed.

18.
Radiat Prot Dosimetry ; 124(4): 372-7, 2007.
Artigo em Inglês | MEDLINE | ID: mdl-17525061

RESUMO

The profile of (137)Cs present in undisturbed soil due to the Chernobyl accident was measured repeatedly for approximately 20 y. The vertical migration of (137)Cs in soil is a very slow process. The mean vertical migration velocity is estimated at approximately 0.1-0.2 cm y(-1). A method based on in situ gamma spectrometry measurements and Monte Carlo computations, aimed at estimating the profile of (137)Cs without performing any soil sampling, is investigated.


Assuntos
Radioisótopos de Césio/análise , Cinza Radioativa/análise , Poluentes Radioativos do Solo/análise , Solo/análise , Acidente Nuclear de Chernobyl , Seguimentos , Modelos Teóricos , Método de Monte Carlo , Espectrometria gama
19.
Appl Radiat Isot ; 64(10-11): 1303-6, 2006.
Artigo em Inglês | MEDLINE | ID: mdl-16549352

RESUMO

When close-geometry detector calibration is required in gamma-ray spectrometry, single-line emitters are usually used in order to avoid true coincidence summing effects. We managed to overcome this limitation by developing a method for the determination of the efficiency of p-type HPGe detectors in close-geometry with a calibrated Cs-134 point source. No separate determination of coincidence summing correction factors is required and a single measurement furnishes the full-energy-peak efficiencies in the 475-1365 keV energy range.


Assuntos
Algoritmos , Radioisótopos de Césio/análise , Radioisótopos de Césio/normas , Radiometria/instrumentação , Radiometria/normas , Transdutores , Calibragem/normas , Análise de Falha de Equipamento/instrumentação , Análise de Falha de Equipamento/métodos , Análise de Falha de Equipamento/normas , Guias como Assunto , Itália , Doses de Radiação , Radiometria/métodos , Padrões de Referência , Valores de Referência , Reprodutibilidade dos Testes , Semicondutores , Sensibilidade e Especificidade
20.
J Vet Pharmacol Ther ; 27(3): 169-81, 2004 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-15189303

RESUMO

The interrelationships between physicochemical properties, absorption and potency of 2-desoxoparaherquamide and five analogs, representing a new anthelmintic class, were evaluated in in vitro and in vivo assays. At pH 7.5, rates of drug absorption by the gastrointestinal nematode Haemonchus contortus and jird small intestine, parameterized by the permeability coefficient, P(e), ranged from 1.2-2.4 x 10(-4) cm/min (nematode) to 2.5-5.5 x 10(-3) cm/min (jird). In the jird intestine, absorption was pH-dependent, with P(e) at pH 7.5 being twice that at pH 4.5, reflecting the negative influence of protonation on transport of these weakly basic molecules. Each compound rapidly paralyzed H. contortus during in vitro exposure to therapeutically relevant concentrations (1-10 microm). The kinetics of drug action on motility in vivo mirrored their in vitro effects; motility concentrations were reduced in nematodes collected from jird stomach 3 h following oral drug dosing, by which time > or =50% clearance of the parasites had occurred. The nematode/medium partition coefficient K ranged from 10.1 to 16.1, consistent with the lipophilic nature of the compounds. The time required to reduce motility in vitro by 50% (t50*) and P(e) were used to determine C(n)*, the concentration of drug in the nematode at t50*, as an indicator of intrinsic potency. In the jird, the apparent potencies of the compounds were insensitive to route of administration (i.e. oral = i.v. = i.p. = i.m.) for H. contortus and two other gastrointestinal nematodes, Ostertagia ostertagi and Trichostrongylus colubriformis; topical administration, however, required three to 10-fold higher doses for equivalent efficacy.


Assuntos
Anti-Helmínticos/farmacologia , Hemoncose/veterinária , Haemonchus/efeitos dos fármacos , Indolizinas/farmacologia , Doenças dos Ovinos/tratamento farmacológico , Compostos de Espiro/farmacologia , Absorção , Administração Oral , Animais , Anti-Helmínticos/administração & dosagem , Anti-Helmínticos/farmacocinética , Feminino , Hemoncose/tratamento farmacológico , Haemonchus/metabolismo , Indolizinas/administração & dosagem , Indolizinas/farmacocinética , Injeções Intramusculares/veterinária , Injeções Intraperitoneais/veterinária , Injeções Intravenosas/veterinária , Testes de Sensibilidade Parasitária , Distribuição Aleatória , Ovinos , Doenças dos Ovinos/parasitologia , Compostos de Espiro/administração & dosagem , Compostos de Espiro/farmacocinética , Trichostrongyloidea/efeitos dos fármacos , Trichostrongyloidea/metabolismo
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...