Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Sensors (Basel) ; 16(8)2016 Jul 28.
Artigo em Inglês | MEDLINE | ID: mdl-27483266

RESUMO

The reduction of nitrate leaching to ensure greater protection of groundwater quality has become a global issue. The development of new technologies for more accurate dosing of nitrates helps optimize fertilization programs. This paper presents the practical application of a newly developed electrochemical sensor designed for in situ quantification of nitrate. To our knowledge, this paper is the first to report the use of electrochemical impedance to determine nitrate concentrations in growing media under forest nursery conditions. Using impedance measurements, the sensor has been tested in laboratory and compared to colorimetric measurements of the nitrate. The developed sensor has been used in water-saturated growing medium and showed good correlation to certified methods, even in samples obtained over a multi-ion fertilisation season. A linear and significant relationship was observed between the resistance and the concentration of nitrates (R² = 0.972), for a range of concentrations of nitrates. We also observed stability of the sensor after exposure of one month to the real environmental conditions of the forest nursery.


Assuntos
Técnicas Biossensoriais/métodos , Agricultura Florestal/métodos , Nitratos/isolamento & purificação , Poluentes Químicos da Água/isolamento & purificação , Monitoramento Ambiental/métodos , Água Subterrânea/análise , Estações do Ano , Poluentes Químicos da Água/química
2.
Sensors (Basel) ; 15(9): 23572-88, 2015 Sep 17.
Artigo em Inglês | MEDLINE | ID: mdl-26393587

RESUMO

This paper describes the development of a low-cost, miniaturized, multiplexed, and connected platform for dielectric impedance spectroscopy (DIS), designed for in situ measurements and adapted to wireless network architectures. The platform has been tested and used as a DIS sensor node on ZigBee mesh and was able to interface up to three DIS sensors at the same time and relay the information through the network for data analysis and storage. The system is built from low-cost commercial microelectronics components, performs dielectric spectroscopy ranging from 5 kHz to 100 kHz, and benefits from an on-the-fly calibration system that makes sensor calibration easy. The paper describes the microelectronics design, the Nyquist impedance response, the measurement sensitivity and accuracy, and the testing of the platform for in situ dielectric impedance spectroscopy applications pertaining to fertilizer sensing, water quality sensing, and touch sensing.

3.
Sensors (Basel) ; 15(7): 17715-27, 2015 Jul 21.
Artigo em Inglês | MEDLINE | ID: mdl-26197322

RESUMO

With the advent of smart cities and big data, precision agriculture allows the feeding of sensor data into online databases for continuous crop monitoring, production optimization, and data storage. This paper describes a low-cost, compact, and scalable nitrate sensor based on electrochemical impedance spectroscopy for monitoring trace amounts of NO3- in selected growing media. The nitrate sensor can be integrated to conventional microelectronics to perform online nitrate sensing continuously over a wide concentration range from 0.1 ppm to 100 ppm, with a response time of about 1 min, and feed data into a database for storage and analysis. The paper describes the structural design, the Nyquist impedance response, the measurement sensitivity and accuracy, and the field testing of the nitrate sensor performed within tree nursery settings under ISO/IEC 17025 certifications.


Assuntos
Espectroscopia Dielétrica/métodos , Nitratos/análise , Solo/química , Agricultura
4.
Sensors (Basel) ; 14(10): 19260-74, 2014 Oct 16.
Artigo em Inglês | MEDLINE | ID: mdl-25325335

RESUMO

The ability to integrate multiple materials into miniaturized fiber structures enables the realization of novel biomedical textile devices with higher-level functionalities and minimally-invasive attributes. In this work, we present novel textile fabrics integrating unobtrusive multi-material fibers that communicate through 2.4 GHz wireless networks with excellent signal quality. The conductor elements of the textiles are embedded within the fibers themselves, providing electrical and chemical shielding against the environment, while preserving the mechanical and cosmetic properties of the garments. These multi-material fibers combine insulating and conducting materials into a well-defined geometry, and represent a cost-effective and minimally-invasive approach to sensor fabrics and bio-sensing textiles connected in real time to mobile communications infrastructures, suitable for a variety of health and life science applications.


Assuntos
Monitorização Ambulatorial , Telemedicina , Tecnologia sem Fio , Humanos , Têxteis
5.
Artigo em Inglês | MEDLINE | ID: mdl-25571432

RESUMO

The ability to integrate multiple materials into miniaturized fiber structures enables the realization of novel biomedical textile devices with higher-level functionalities and minimally-invasive attributes. In this work, we present novel textile fabrics integrating unobtrusive multi-material fibers that communicate through 2.4 GHz wireless networks with excellent signal quality. The conductor elements of the textiles are embedded within the fibers themselves, providing electrical and chemical shielding against the environment, while preserving the mechanical and cosmetic properties of the garments. These multi-material fibers combine insulating and conducting materials into a well-defined geometry, and represent a cost-effective and minimally-invasive approach to sensor fabrics and bio-sensing textiles connected in real time to mobile communications infrastructures, suitable for a variety of health and life science applications.


Assuntos
Vestuário , Têxteis , Técnicas Biossensoriais , Humanos , Monitorização Fisiológica , Propriedades de Superfície , Tecnologia sem Fio
6.
Nature ; 431(7010): 826-9, 2004 Oct 14.
Artigo em Inglês | MEDLINE | ID: mdl-15483607

RESUMO

The combination of conductors, semiconductors and insulators with well-defined geometries and at prescribed length scales, while forming intimate interfaces, is essential in most functional electronic and optoelectronic devices. These are typically produced using a variety of elaborate wafer-based processes, which allow for small features, but are restricted to planar geometries and limited coverage area. In contrast, the technique of fibre drawing from a preformed reel or tube is simpler and yields extended lengths of highly uniform fibres with well-controlled geometries and good optical transport characteristics. So far, this technique has been restricted to particular materials and larger features. Here we report on the design, fabrication and characterization of fibres made of conducting, semiconducting and insulating materials in intimate contact and in a variety of geometries. We demonstrate that this approach can be used to construct a tunable fibre photodetector comprising an amorphous semiconductor core contacted by metallic microwires, and surrounded by a cylindrical-shell resonant optical cavity. Such a fibre is sensitive to illumination along its entire length (tens of meters), thus forming a photodetecting element of dimensionality one. We also construct a grid of such fibres that can identify the location of an illumination point. The advantage of this type of photodetector array is that it needs a number of elements of only order N, in contrast to the conventional order N2 for detector arrays made of photodetecting elements of dimensionality zero.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...