Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
1.
Scand J Surg ; 109(4): 320-327, 2020 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-31315537

RESUMO

BACKGROUND AND AIMS: Circulatory arrest carries a high risk of neurological damage, but modern monitoring methods lack reliability, and is susceptible to the generalized effects of both anesthesia and hypothermia. The objective of this prospective, explorative study was to research promising, reliable, and noninvasive methods of neuromonitoring, capable of predicting neurological outcome after hypothermic circulatory arrest. MATERIALS AND METHODS: Thirty patients undergoing hypothermic circulatory arrest during surgery of the thoracic aorta were recruited in a single center and over the course of 4 years. Neuromonitoring was performed with a four-channel electroencephalogram montage and a near-infrared spectroscopy monitor. All data were tested off-line against primary neurological outcome, which was poor if the patient suffered a significant neurological complication (stroke, operative death). RESULTS: A poor primary neurological outcome seen in 10 (33%) patients. A majority (63%) of the cases were emergency surgery, and thus, no neurological baseline evaluation was possible. The frontal hemispheric asymmetry of electroencephalogram, as measured by the brain symmetry index, predicted primary neurological outcome with a sensitivity of 79 (interquartile range; 62%-88%) and specificity of 71 (interquartile range; 61%-84%) during the first 6 h after end of circulatory arrest. CONCLUSION: The hemispheric asymmetry of frontal electroencephalogram is inherently resistant to generalized dampening effects and is predictive of primary neurological outcome. The brain symmetry index provides an easy-to-use, noninvasive neuromonitoring method for surgery of the thoracic aorta and postoperative intensive care.


Assuntos
Doenças da Aorta/cirurgia , Parada Cardíaca Induzida , Hipotermia Induzida , Monitorização Neurofisiológica , Adulto , Idoso , Doenças da Aorta/diagnóstico por imagem , Doenças da Aorta/fisiopatologia , Eletroencefalografia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Espectroscopia de Luz Próxima ao Infravermelho , Resultado do Tratamento
2.
Br J Anaesth ; 107(5): 710-8, 2011 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-21862496

RESUMO

BACKGROUND: Excessive sedation is associated with adverse patient outcomes during critical illness, and a validated monitoring technology could improve care. We developed a novel method, the responsiveness index (RI) of the frontal EMG. We compared RI data with Ramsay clinical sedation assessments in general and cardiac intensive care unit (ICU) patients. METHODS: We developed the algorithm by iterative analysis of detailed observational data in 30 medical-surgical ICU patients and described its performance in this cohort and 15 patients recovering from scheduled cardiac surgery. Continuous EMG data were collected via frontal electrodes and RI data compared with modified Ramsay sedation state assessments recorded regularly by a blinded trained observer. RI performance was compared with Entropy™ across Ramsay categories to assess validity. RESULTS: RI correlated well with the Ramsay category, especially for the cardiac surgery cohort (general ICU patients ρ=0.55; cardiac surgery patients ρ=0.85, both P<0.0001). Discrimination across all Ramsay categories was reasonable in the general ICU patient cohort [P(K)=0.74 (sem 0.02)] and excellent in the cardiac surgery cohort [P(K)=0.92 (0.02)]. Discrimination between 'lighter' vs 'deeper' (Ramsay 1-3 vs 4-6) was good for general ICU patients [P(K)=0.80 (0.02)] and excellent for cardiac surgery patients [P(K)=0.96 (0.02)]. Performance was significantly better than Entropy™. Examination of individual cases suggested good face validity. CONCLUSIONS: RI of the frontal EMG has promise as a continuous sedation state monitor in critically ill patients. Further investigation to determine its utility in ICU decision-making is warranted.


Assuntos
Anestesia , Lobo Frontal/efeitos dos fármacos , Monitorização Fisiológica/métodos , Adulto , Idoso , Idoso de 80 Anos ou mais , Algoritmos , Período de Recuperação da Anestesia , Procedimentos Cirúrgicos Cardíacos , Estudos de Coortes , Cuidados Críticos/métodos , Estado Terminal , Eletromiografia/métodos , Humanos , Pessoa de Meia-Idade , Reprodutibilidade dos Testes , Respiração Artificial
3.
Br J Anaesth ; 98(4): 447-55, 2007 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-17329347

RESUMO

BACKGROUND: Inadequate analgesia during general anaesthesia may present as undesirable haemodynamic responses. No objective measures of the adequacy of analgesia exist. We aimed at developing a simple numerical measure of the level of surgical stress in an anaesthetized patient. METHODS: Sixty and 12 female patients were included in the development and validation data sets, respectively. All patients had elective surgery with propofol-remifentanil target controlled anaesthesia. Finger photoplethysmography and electrocardiography waveforms were recorded throughout anaesthesia and various waveform parameters were extracted off-line. Total surgical stress (TSS) for a patient was estimated based on stimulus intensity and remifentanil concentration. The surgical stress index (SSI) was developed to correlate with the TSS estimate in the development data set. The performance of SSI was validated within the validation data set during and before surgery, especially at skin incision and during changes of the predicted remifentanil effect-site concentration. RESULTS: SSI was computed as a combination of normalized heart beat interval (HBI(norm)) and plethysmographic pulse wave amplitude (PPGA(norm)): SSI = 100-(0.7*PPGA(norm)+0.3*HBI(norm)). SSI increased at skin incision and stayed higher during surgery than before surgery; SSI responded to remifentanil concentration changes and was higher at the lower concentrations of remifentanil. CONCLUSIONS: SSI reacts to surgical nociceptive stimuli and analgesic drug concentration changes during propofol-remifentanil anaesthesia. Further validation studies of SSI are needed to elucidate its usefulness during other anaesthetic and surgical conditions.


Assuntos
Anestesia Geral/métodos , Complicações Intraoperatórias/diagnóstico , Monitorização Intraoperatória/métodos , Índice de Gravidade de Doença , Estresse Fisiológico/diagnóstico , Adulto , Idoso , Analgésicos Opioides/administração & dosagem , Anestésicos Combinados/administração & dosagem , Anestésicos Intravenosos/administração & dosagem , Relação Dose-Resposta a Droga , Eletrocardiografia/efeitos dos fármacos , Feminino , Frequência Cardíaca/efeitos dos fármacos , Humanos , Pessoa de Meia-Idade , Modelos Neurológicos , Fotopletismografia , Piperidinas/administração & dosagem , Propofol/administração & dosagem , Remifentanil , Processamento de Sinais Assistido por Computador , Estresse Fisiológico/etiologia
4.
Anaesthesia ; 60(9): 862-9, 2005 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-16115246

RESUMO

ENTROPY index monitoring, based on spectral entropy of the electroencephalogram, is a promising new method to measure the depth of anaesthesia. We examined the association between spectral entropy and regional cerebral blood flow in healthy subjects anaesthetised with 2%, 3% and 4% end-expiratory concentrations of sevoflurane and 7.6, 12.5 and 19.0 microg.ml(-1) plasma drug concentrations of propofol. Spectral entropy from the frequency band 0.8-32 Hz was calculated and cerebral blood flow assessed using positron emission tomography and [(15)O]-labelled water at baseline and at each anaesthesia level. Both drugs induced significant reductions in spectral entropy and cortical and global cerebral blood flow. Midfrontal-central spectral entropy was associated with individual frontal and whole brain blood flow values across all conditions, suggesting that this novel measure of anaesthetic depth can depict global changes in neuronal activity induced by the drugs. The cortical areas of the most significant associations were remarkably similar for both drugs.


Assuntos
Circulação Cerebrovascular/efeitos dos fármacos , Eletroencefalografia/efeitos dos fármacos , Éteres Metílicos/farmacologia , Monitorização Intraoperatória/métodos , Propofol/farmacologia , Adulto , Anestésicos Inalatórios/farmacologia , Anestésicos Intravenosos/farmacologia , Encéfalo/diagnóstico por imagem , Relação Dose-Resposta a Droga , Entropia , Humanos , Masculino , Tomografia por Emissão de Pósitrons , Sevoflurano
5.
Acta Anaesthesiol Scand ; 48(2): 145-53, 2004 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-14995935

RESUMO

BACKGROUND: Time-frequency balanced spectral entropy of electroencephalogram (EEG) and frontal electromyogram (FEMG) is a novel measure of hypnosis during anesthesia. Two Entropy parameters are described: Response entropy (RE) is calculated from EEG and FEMG; and State Entropy (SE) is calculated mainly from EEG. This study was performed to validate their performance during transition from consciousness to unconsciousness under different anesthetic agents. METHODS: Response entropy, SE [S/5 Entropy Module, M-ENTROPY (later in text: Entropy), Datex-Ohmeda Division, Instrumentarium Corp., Helsinki, Finland] and BIS (BIS XP, A-2000, Aspect Medical Systems, Newton, MA) data were collected from 70 patients; 30 anesthetized with propofol 2 mg kg-1, 20 with sevoflurane inhalation, and 20 with thiopental 5 mg kg-1. Loss and regaining of consciousness (LOC, ROC) was tested every 10 s, and sensitivity, specificity, and prediction probability (Pk) were calculated. Behavior of the indices was studied. RESULTS: Sensitivity, specificity, and Pk values for consciousness were high and similar for all indices. During regaining of consciousness after propofol bolus, RE, SE, and BIS values recovered by 81 +/- 22%, 75 +/- 26%, and 59 +/- 18% (mean +/- SD), respectively, from the minimum relative to their baseline. After thiopental bolus, RE, SE, and BIS values recovered by 86+/-21%, 88 +/- 13%, and 63 +/- 14%, respectively. The relative rise was higher in RE and SE compared with BIS (P < 0.01). During deep levels of hypnosis, RE and SE decreased monotonously as a function of burst suppression ratio, while BIS showed biphasic behavior. On average, RE indicated emergence from anesthesia 11 s earlier than SE, and 12.4 s earlier than BIS. CONCLUSIONS: All indices, RE, SE, and BIS, distinguished excellently between conscious and unconscious states during propofol, sevoflurane, and thiopental anesthesia. During burst suppression, Entropy parameters RE and SE, but not BIS, behave monotonously. During regaining of consciousness after a thiopental or propofol bolus, RE and SE values recovered significantly closer to their baseline values than did BIS. Response entropy indicates emergence from anesthesia earlier than SE or BIS.


Assuntos
Anestésicos/farmacologia , Eletroencefalografia/efeitos dos fármacos , Éteres Metílicos/farmacologia , Propofol/farmacologia , Tiopental/farmacologia , Adolescente , Adulto , Idoso , Eletromiografia/efeitos dos fármacos , Entropia , Humanos , Pessoa de Meia-Idade , Sensibilidade e Especificidade , Sevoflurano , Fatores de Tempo
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...