Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 13 de 13
Filtrar
1.
Radiat Prot Dosimetry ; 195(3-4): 434-442, 2021 Oct 12.
Artigo em Inglês | MEDLINE | ID: mdl-33683309

RESUMO

PURPOSE: Digital tomosynthesis (DTS) is currently undergoing validation for potential clinical implications. The aim of this study was to investigate the potential for DTS as a low-dose alternative to computed tomography (CT) in imaging of pulmonary pathology in patients with cystic fibrosis (CF). METHODS: DTS and CT were performed as part of the routine triannual follow-up in 31 CF patients. Extent of disease was quantified according to modality-specific scoring systems. Statistical analysis included Spearman's rank correlation coefficient (r) and Krippendorff's alpha (α). MAJOR FINDINGS: The median effective dose was 0.14 for DTS and 2.68 for CT. Intermodality correlation was very strong for total score and the subscores regarding bronchiectasis and bronchial wall-thickening (r = 0.82-0.91, P < 0.01). Interobserver reliability was high for total score, bronchiectasis and mucus plugging (α = 0.83-0.93) in DTS. CONCLUSION: Chest tomosynthesis could be a low-dose alternative to CT in quantitative estimation of structural lung disease in CF.


Assuntos
Fibrose Cística , Fibrose Cística/diagnóstico por imagem , Humanos , Pulmão/diagnóstico por imagem , Radiografia , Reprodutibilidade dos Testes , Tomografia Computadorizada por Raios X
2.
Artigo em Inglês | MEDLINE | ID: mdl-28356729

RESUMO

BACKGROUND: Data are lacking from general population studies on how to define changes in lung function after bronchodilation. This study aimed to analyze different measures of bronchodilator response of forced expiratory volume in 1 second (FEV1), forced vital capacity (FVC) and slow vital capacity (SVC). MATERIALS AND METHODS: Data were derived from the Swedish Cardiopulmonary Bioimage Study (SCAPIS) Pilot study. This analysis comprised 1,050 participants aged 50-64 years from the general population. Participants were investigated using a questionnaire, and FEV1, FVC and SVC were recorded before and 15 minutes after inhalation of 400 µg of salbutamol. A bronchodilator response was defined as the relative change from baseline value expressed as the difference in units of percent predicted normal. Predictors of bronchodilator responses were assessed using multiple linear regression models. Airway obstruction was defined as FEV1/FVC ratio below lower limit of normal (LLN) before bronchodilation, and COPD was defined as an FEV1/FVC ratio below LLN after bronchodilation. Physician-diagnosed asthma was defined as an affirmative answer to "Have you ever had asthma diagnosed by a physician?". Asymptomatic never-smokers were defined as those not reporting physician-diagnosed asthma, physician-diagnosed COPD or emphysema, current wheeze or chronic bronchitis and being a lifelong never-smoker. RESULTS: Among all subjects, the greatest bronchodilator responses (FEV1, FVC and SVC) were found in subjects with asthma or COPD. The upper 95th percentile of bronchodilator responses in asymptomatic never-smokers was 8.7% for FEV1, 4.2% for FVC and 5.0% for SVC. The bronchodilator responses were similar between men and women. In a multiple linear regression model comprising all asymptomatic never-smokers, the bronchodilator response of FEV1 was significantly associated with airway obstruction and height. CONCLUSION: When the bronchodilator response in asymptomatic never-smokers is reported as the difference in units of predicted normal, significant reversibility of FEV1, FVC and SVC to bronchodilators is ~9%, 4% and 5%, respectively.


Assuntos
Agonistas de Receptores Adrenérgicos beta 2/administração & dosagem , Albuterol/administração & dosagem , Asma/fisiopatologia , Broncodilatadores/administração & dosagem , Volume Expiratório Forçado/efeitos dos fármacos , Pulmão/efeitos dos fármacos , Doença Pulmonar Obstrutiva Crônica/fisiopatologia , Capacidade Vital/efeitos dos fármacos , Administração por Inalação , Asma/diagnóstico , Asma/epidemiologia , Doenças Assintomáticas , Feminino , Humanos , Modelos Lineares , Pulmão/fisiopatologia , Masculino , Pessoa de Meia-Idade , Projetos Piloto , Doença Pulmonar Obstrutiva Crônica/diagnóstico , Doença Pulmonar Obstrutiva Crônica/epidemiologia , Fumar/efeitos adversos , Inquéritos e Questionários , Suécia/epidemiologia , Fatores de Tempo
3.
J Intern Med ; 278(6): 645-59, 2015 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-26096600

RESUMO

Cardiopulmonary diseases are major causes of death worldwide, but currently recommended strategies for diagnosis and prevention may be outdated because of recent changes in risk factor patterns. The Swedish CArdioPulmonarybioImage Study (SCAPIS) combines the use of new imaging technologies, advances in large-scale 'omics' and epidemiological analyses to extensively characterize a Swedish cohort of 30 000 men and women aged between 50 and 64 years. The information obtained will be used to improve risk prediction of cardiopulmonary diseases and optimize the ability to study disease mechanisms. A comprehensive pilot study in 1111 individuals, which was completed in 2012, demonstrated the feasibility and financial and ethical consequences of SCAPIS. Recruitment to the national, multicentre study has recently started.


Assuntos
Doenças Cardiovasculares , Doença Pulmonar Obstrutiva Crônica , Doenças Cardiovasculares/diagnóstico , Doenças Cardiovasculares/epidemiologia , Doenças Cardiovasculares/etiologia , Doenças Cardiovasculares/metabolismo , Doenças Cardiovasculares/terapia , Feminino , Técnicas Genéticas , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Proteômica/métodos , Saúde Pública/métodos , Saúde Pública/estatística & dados numéricos , Doença Pulmonar Obstrutiva Crônica/diagnóstico , Doença Pulmonar Obstrutiva Crônica/epidemiologia , Doença Pulmonar Obstrutiva Crônica/etiologia , Doença Pulmonar Obstrutiva Crônica/metabolismo , Doença Pulmonar Obstrutiva Crônica/terapia , Fatores de Risco , Fatores Socioeconômicos , Suécia/epidemiologia
4.
Scand J Immunol ; 76(4): 411-20, 2012 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-22823472

RESUMO

The aim of the study was to evaluate long-term clinical and immunological effects of anti-B cell treatment in patients with antineutrophil cytoplasmic antibodies (ANCA)-associated vasculitis refractory to conventional immunosuppressive treatment. Rituximab (RTX) was added to the ongoing immunosuppressive treatment in 29 patients with refractory ANCA-associated vasculitis. The disease activity was measured using Birmingham Vasculitis Activity Score/Wegener's granulomatosis (BVAS/WG score), and clinical laboratory variables were recorded. The median BVAS/WG score before treatment was 6 (IQR 3-8), and 28 patients (97%) had disease flare classified either severe (62%) or limited (34%). Six of 29 patients (21%) achieved a complete remission, and 12 (41%) had a treatment response with ≥50% decrease in BVAS/WG score at 6 months. Fourteen patients (64%) with kidney involvement achieved remission, and in seven patients (50%), no flare was seen during the follow-up period. Three patients had renal flare and were successfully re-treated with RTX. Seventeen patients had disease symptoms from airways and eyes at RTX initiation, whereas only 29% displayed ≥50% treatment response. Limited clinical improvement was seen in patients with endobronchial lesions and trachea-subglottic granulomatous disease. RTX is a potent therapeutic option for ANCA-associated vasculitis refractory to conventional treatment. Best response may be expected in patients with vasculitic manifestations.


Assuntos
Vasculite Associada a Anticorpo Anticitoplasma de Neutrófilos/tratamento farmacológico , Anticorpos Anticitoplasma de Neutrófilos/sangue , Anticorpos Monoclonais Murinos/administração & dosagem , Linfócitos B/efeitos dos fármacos , Rim/efeitos dos fármacos , Corticosteroides/administração & dosagem , Adulto , Idoso , Vasculite Associada a Anticorpo Anticitoplasma de Neutrófilos/sangue , Vasculite Associada a Anticorpo Anticitoplasma de Neutrófilos/imunologia , Vasculite Associada a Anticorpo Anticitoplasma de Neutrófilos/patologia , Anticorpos Anticitoplasma de Neutrófilos/imunologia , Linfócitos B/imunologia , Linfócitos B/patologia , Quimioterapia Combinada , Olho/efeitos dos fármacos , Olho/imunologia , Olho/patologia , Feminino , Seguimentos , Humanos , Imunossupressores/administração & dosagem , Rim/imunologia , Rim/patologia , Masculino , Pessoa de Meia-Idade , Indução de Remissão , Projetos de Pesquisa , Sistema Respiratório/efeitos dos fármacos , Sistema Respiratório/imunologia , Sistema Respiratório/patologia , Rituximab , Índice de Gravidade de Doença
5.
Radiat Prot Dosimetry ; 139(1-3): 124-9, 2010.
Artigo em Inglês | MEDLINE | ID: mdl-20181650

RESUMO

Since December 2006, approximately 3800 clinical chest tomosynthesis examinations have been performed at our department at Sahlgrenska University Hospital. A subset of the examinations has been included in studies of the detectability of pulmonary nodules, using computed tomography (CT) as the gold standard. Visibility studies, in which chest tomosynthesis and CT have been compared side-by side, have been used to determine the depiction potential of chest tomosynthesis. Comparisons with conventional chest radiography have been made. In the clinical setting, chest tomosynthesis has mostly been used as an additional examination. The most frequent indication for chest tomosynthesis has been suspicion of a nodule or tumour. In visibility studies, tomosynthesis has depicted over 90 % of the nodules seen on the CT scan. The corresponding figure for chest radiography has been <30 %. In the detection studies, the lesion-level sensitivity has been approximately 60 % for tomosynthesis and 20 % for chest radiography. In one of the detection studies, an analysis of all false-positive nodules was performed. This analysis showed that all findings had morphological correlates on the CT examinations. The majority of the false-positive nodules were localised in the immediate subpleural region. In conclusion, chest tomosynthesis is an improved chest radiography method, which can be used to optimise the use of CT resources, thereby reducing the radiation dose to the patient population. However, there are some limitations with chest tomosynthesis. For example, patients undergoing tomosynthesis have to be able to stand still and hold their breath firmly for 10 s. Also, chest tomosynthesis has a limited depth resolution, which may explain why pathology in the subpleural region is more difficult to interpret and artefacts from medical devices may occur.


Assuntos
Neoplasias Pulmonares/diagnóstico por imagem , Radiografia Torácica/métodos , Nódulo Pulmonar Solitário/diagnóstico por imagem , Tomografia Computadorizada por Raios X/métodos , Humanos , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Suécia
6.
Radiat Prot Dosimetry ; 139(1-3): 140-3, 2010.
Artigo em Inglês | MEDLINE | ID: mdl-20133329

RESUMO

The aim of the present study was to investigate nodule size measurements with chest tomosynthesis (TS) and computed tomography (CT). A 26-mm thick phantom, composed of a Polylite block with embedded spheres of different materials and sizes (4-20 mm), was scanned by both CT and TS. Six observers without prior knowledge of the true diameters of the spheres independently measured the diameter of the spheres on the CT and TS images. Four observers were allowed to change the window settings and two of the observers used predetermined fixed viewing conditions. The mean relative errors for all observers and all measured spheres compared with the known diameter of the spheres were 1.4 % (standard deviation, SD: 5.4 %) on CT images and -1.1 % (SD: 5.0 %) on TS images. With regard to the four observers where the window settings were at the discretion of the observer, the mean relative errors were 1.4 % (SD: 6.4 %) on CT images and -1.7 % (SD: 5.7 %) on TS images. Regarding the two observers using identical viewing conditions the mean relative error was 1.5 % (SD: 2.8 %) on CT images and 0.2 % (SD: 2.6 %) on TS images. In conclusion, the study suggests that nodule size measurements on chest TS might be an alternative to measurements on CT.


Assuntos
Algoritmos , Neoplasias Pulmonares/diagnóstico por imagem , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Radiografia Torácica/métodos , Nódulo Pulmonar Solitário/diagnóstico por imagem , Tomografia Computadorizada por Raios X/métodos , Humanos , Imagens de Fantasmas , Intensificação de Imagem Radiográfica/métodos , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
7.
Acta Radiol ; 50(8): 884-91, 2009 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-19639475

RESUMO

BACKGROUND: The new technique chest tomosynthesis refers to the principle of collecting low-dose projections of the chest at different angles and using these projections to reconstruct section images of the chest at a radiation dose comparable to that of chest radiography. PURPOSE: To investigate if, for experienced thoracic radiologists, the detectability of pulmonary nodules obtained after only a short initial learning period of chest tomosynthesis improves with additional clinical experience of the new technique. MATERIAL AND METHODS: Two readings of the same clinical chest tomosynthesis cases, the first performed after 6 months of clinical experience and the second after an additional period of 1 year, were conducted. Three senior thoracic radiologists, with more than 20 years of experience of chest radiography, acted as observers, with the task of detecting pulmonary nodules in a jackknife free-response receiver operating characteristics (JAFROC1) study. The image material consisted of 42 patients with and 47 patients without pulmonary nodules examined with chest tomosynthesis. Multidetector computed tomography (MDCT) was used as a reference. The total number of nodules was 131. The JAFROC1 figure of merit (FOM) was used as the principal measure of detectability. RESULTS: The difference in the observer-averaged JAFROC1 FOM of the two readings was 0.004 (95% confidence interval: -0.11, 0.12; F-statistic: 0.01 on 1 and 2.65 df; P=0.91). Thus, no significant improvement in detectability was found after the additional clinical experience of tomosynthesis. CONCLUSION: The study indicates that experienced thoracic radiologists already within the first months of clinical use of chest tomosynthesis are able to take advantage of the new technique in the task of detecting pulmonary nodules.


Assuntos
Nódulos Pulmonares Múltiplos/diagnóstico por imagem , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Tomografia Computadorizada por Raios X/métodos , Humanos , Variações Dependentes do Observador , Imagens de Fantasmas , Curva ROC , Doses de Radiação , Radiografia Torácica , Sensibilidade e Especificidade
8.
Acta Radiol ; 49(7): 755-60, 2008 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-19143061

RESUMO

BACKGROUND: Dose modulation can be used to reduce the radiation dose in computed tomography (CT) examinations while still obtaining the necessary diagnostic image quality. Multidetector-row computed tomography (MDCT) provides the possibility of simultaneous reconstruction of thin and thick slices from the same raw data. PURPOSE: To compare thin slices reconstructed from a dose-modulated helical acquisition and conventional high-resolution computed tomography (HRCT) images taken with the "step and shoot" technique in terms of visibility and motion artifacts, in order to investigate the possibility of excluding "step and shoot" acquisition from the HRCT examination. MATERIAL AND METHODS: Twenty patients were examined by a dose-modulated helical acquisition, "MDCT smart mA," and by a noncontiguous cross-sectional high-resolution 16-row MDCT examination, "MDCT step and shoot." Images from four anatomical levels, made anonymous regarding identity and technical data, were analyzed in random order by four thoracic radiologists. RESULTS: "MDCT smart mA" was worse than "MDCT step and shoot" in terms of visibility. Concerning motion artifacts, "MDCT smart mA" was better than "MDCT step and shoot." CONCLUSION: Thin images reconstructed from a dose-modulated 16-row helical MDCT acquisition ("MDCT smart mA"), as performed in our study, do not provide sufficient image quality regarding visibility compared to the "MDCT step and shoot" technique for the latter technique to be excluded from the HRCT examination.


Assuntos
Doenças Pulmonares Intersticiais/diagnóstico por imagem , Tomografia Computadorizada por Raios X/métodos , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Artefatos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Doses de Radiação , Interpretação de Imagem Radiográfica Assistida por Computador , Tomografia Computadorizada Espiral
9.
Acta Radiol ; 48(9): 956-61, 2007 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-17957508

RESUMO

BACKGROUND: High-resolution computed tomography is the image procedure of choice in the evaluation of interstitial lung disease. Multidetector-row computed tomography provides the possibility of simultaneous reconstruction of thin and thick slices from the same raw data, acquired from one single series. Thus, it may be tempting to exclude the step-and-shoot series. PURPOSE: To compare high-resolution computed tomography (HRCT step-and-shoot) from single-slice CT (SSCT) and 16-channel multidetector CT (MDCT) in terms of visibility and motion artifacts, and to investigate whether thin images reconstructed from helical MDCT are equal to or better than conventional HRCT by SSCT in terms of visibility and motion artifacts. MATERIAL AND METHODS: 20 patients underwent HRCT step-and-shoot by SSCT (SSCT step-and-shoot) and MDCT (MDCT step-and-shoot), and a helical MDCT acquisition (MDCT helical). Images from four anatomical levels were analyzed in random order regarding visibility and motion artifacts. RESULTS: Visibility using MDCT step-and-shoot was significantly better than or equal to SSCT step-and-shoot for segmental bronchi and fissures, but not for subsegmental bronchi. For MDCT helical, visibility was equal to or better than SSCT step-and-shoot for segmental bronchi, but not for fissures and subsegmental bronchi. Concerning motion artifacts, MDCT step-and-shoot and MDCT helical were significantly better than or equal to SSCT step-and-shoot. CONCLUSION: The image quality (accounting for motion artifacts and visibility) of SSCT step-and-shoot and MDCT step-and-shoot is comparable. The visibility of anatomic structures in images from MDCT helical is inferior to HRCT step-and-shoot.


Assuntos
Doenças Pulmonares Intersticiais/diagnóstico por imagem , Tomografia Computadorizada por Raios X/métodos , Adulto , Idoso , Artefatos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Movimento (Física) , Variações Dependentes do Observador , Estudos Prospectivos , Interpretação de Imagem Radiográfica Assistida por Computador , Tomografia Computadorizada Espiral
10.
Acta Radiol ; 46(3): 237-45, 2005 May.
Artigo em Inglês | MEDLINE | ID: mdl-15981719

RESUMO

PURPOSE: To assess the ability of a conventional density mask method to detect mild emphysema by high-resolution computed tomography (HRCT); to analyze factors influencing quantification of mild emphysema; and to validate a new algorithm for detection of mild emphysema. MATERIAL AND METHODS: Fifty-five healthy male smokers and 34 never-smokers, 61-62 years of age, were examined. Emphysema was evaluated visually, by the conventional density mask method, and by a new algorithm compensating for the effects of gravity and artifacts due to motion and the reconstruction algorithm. Effects of the reconstruction algorithm, slice thickness, and various threshold levels on the outcome of the density mask area were evaluated. RESULTS: Forty-nine percent of the smokers had mild emphysema. The density mask area was higher the thinner the slice irrespective of the reconstruction algorithm and threshold level. The sharp algorithm resulted in increased density mask area. The new reconstruction algorithm could discriminate between smokers with and those without mild emphysema, whereas the density mask method could not. The diagnostic ability of the new algorithm was dependent on lung level. At about 90% specificity, sensitivity was 65-100% in the apical levels, but low in the rest of the lung. CONCLUSION: The conventional density mask method is inadequate for detecting mild emphysema, while the new algorithm improves the diagnostic ability but is nevertheless still imperfect.


Assuntos
Absorciometria de Fóton/métodos , Enfisema/diagnóstico , Pulmão/diagnóstico por imagem , Tomografia Computadorizada por Raios X/métodos , Algoritmos , Artefatos , Enfisema/diagnóstico por imagem , Humanos , Masculino , Pessoa de Meia-Idade , Valores de Referência , Sensibilidade e Especificidade , Índice de Gravidade de Doença , Suécia
11.
Acta Radiol ; 45(1): 44-52, 2004 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-15164778

RESUMO

PURPOSE: To elucidate whether emphysematous lesions and other high-resolution computed tomography (HRCT) findings considered associated with smoking are part of a progressive process, and to measure the extent to which similar changes are found in never-smokers. MATERIAL AND METHODS: Healthy smokers and never-smokers were recruited from a randomized epidemiological study and investigated with a 6-year interval. Emphysema, parenchymal and subpleural nodules, ground-glass opacities, bronchial alterations, and septal lines were evaluated in 66 subjects (40 smokers, 11 of whom had stopped smoking in the interval, and 26 never-smokers). Lung function was tested. RESULTS: All except emphysematous lesions were present to some extent in never-smokers. Emphysema, parenchymal nodules, and septal lines occurred significantly more in current smokers, and a progression in extent of emphysema, ground-glass opacities, bronchial alterations and septal lines was seen. There was no significant change among those who stopped and never-smokers except for bronchial alterations, which progressed in never-smokers. CONCLUSION: In healthy, elderly never-smokers a low extent of various HRCT findings has to be considered normal. Emphysema, parenchymal nodules, and ground-glass opacities are indicative of smoking-induced disease. Further progress may cease if smoking is stopped.


Assuntos
Fumar , Tomografia Computadorizada por Raios X , Idoso , Seguimentos , Humanos , Masculino , Fatores de Tempo
12.
Acta Radiol ; 44(5): 517-24, 2003 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-14510759

RESUMO

PURPOSE: To test the hypothesis that diffuse and/or focal air trapping are sensitive indicators of airflow obstruction in smoker's small airways disease, when age, gender and presence of emphysematous lesions were allowed for. MATERIAL AND METHODS: Fifty-eight smokers and 34 never smokers, recruited from a randomized population study of men born in 1933, were investigated by HRCT and by extended pulmonary function tests, including a sensitive test for small airways disease (N2 slope). Diffuse air trapping was evaluated by calculating a quotient of mean lung density at expiration and inspiration. Focal air trapping was scored visually by consensus. RESULTS: Diffuse air trapping did not differ between non-emphysematous smokers and never smokers. Furthermore, diffuse air trapping correlated well to the quotient between the residual volume and total lung capacity (RV/TLC, p = 0.01) and was consequently higher in emphysematous smokers than in never smokers. Focal air trapping was found as frequently in smokers without emphysema as in never smokers. Smokers with emphysema showed significantly less focal air trapping. Neither the N2 slope nor any of the other lung function variables differed between those with and without focal air trapping among non-emphysematous smokers. CONCLUSION: Neither diffuse nor focal air trapping are sensitive indicators of smoker's small airways disease.


Assuntos
Pneumopatias Obstrutivas/etiologia , Fumar/efeitos adversos , Idoso , Ar , Enfisema/diagnóstico , Enfisema/epidemiologia , Enfisema/etiologia , Enfisema/fisiopatologia , Humanos , Pneumopatias Obstrutivas/diagnóstico , Pneumopatias Obstrutivas/epidemiologia , Pneumopatias Obstrutivas/fisiopatologia , Masculino
13.
Eur Radiol ; 13(6): 1235-40, 2003 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-12764637

RESUMO

The aim of this study was to evaluate the ability of experienced thoracic radiologists to assess full inspiration based on two CT slices, one above and one below the carina, in normal subjects. Ten healthy volunteers were studied. Total lung capacity (TLC) was measured with a body plethysmograph. High-resolution computed tomography (HRCT) was performed in two slices at TLC and at various expired volumes. Mean Hounsfield values (HU) were calculated. Unidentifiable images, stored on a web server, were analysed visually by experienced thoracic radiologists. The results show that the mean lung density at TLC varied by approximately 40 HU between individuals. Within an individual this may correspond to a decrease in lung volume of approximately 25% of TLC. On visual determination of images taken at 65-74% of TLC, more than one-third of the images were assessed as taken at full inspiration; of the images taken at 75-84% of TLC, approximately 50% were assessed as taken at full inspiration. We conclude that visual determination of full inspiration on CT images in normal subjects is highly inaccurate. If quantitative density measurements are to be used in the diagnosis or follow-up of lung disease, thorough control of full inspiration is recommended.


Assuntos
Pulmão/diagnóstico por imagem , Tomografia Computadorizada por Raios X , Adulto , Feminino , Humanos , Processamento de Imagem Assistida por Computador , Modelos Lineares , Masculino , Variações Dependentes do Observador , Radiografia Torácica , Respiração , Capacidade Pulmonar Total
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...