Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 33
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Small Methods ; : e2301328, 2024 Mar 05.
Artigo em Inglês | MEDLINE | ID: mdl-38441281

RESUMO

A new method for time-resolved X-ray absorption near edge structure (XANES) spectroscopy that enables faster data acquisition and requires smaller sample quantities for high-quality data, thus allowing the analysis of more samples in a shorter time is introduced. The method uses large bandwidth free electron laser pulses to measure laser-excited XANES spectra in transmission mode. A beam-splitting grating configuration allows simultaneous measurements of the spectra of the incoming X-ray Free Electron Laser (XFEL) pulses and transmission XANES, which is crucial for compensating the pulse-dependent intensity and spectrum fluctuations due to the self-amplified spontaneous emission operation. The implementation of this new methodology is applied on a liquid solution of ammonium iron(III) oxalate jet and is compared to previous results, showing great improvements in the speed of acquisition and spectral resolution, and the ability to measure a large 2-D spectral-time map quickly.

2.
Light Sci Appl ; 12(1): 107, 2023 May 04.
Artigo em Inglês | MEDLINE | ID: mdl-37142565

RESUMO

Achromatic doublets are combinations of two individual lenses designed to focus different wavelengths of light in the same position. Apochromatic optics are improved versions of the achromatic schemes which extend the wavelength range significantly. Both achromatic and apochromatic optics are well-established for visible light. However, X-ray achromatic lenses did not exist until very recently, and X-ray apochromatic lenses have never been experimentally demonstrated. Here, we create an X-ray apochromatic lens system using an appropriate combination of a Fresnel zone plate and a diverging compound refractive lens with a tuned separation distance. The energy-dependent performance of this apochromat was characterized at photon energies between 6.5 and 13.0 keV by ptychographic reconstruction of the focal spot and scanning transmission X-ray microscopy of a resolution test sample. The apochromat delivered a reconstructed focal spot size of 940 × 740 nm2. The apochromatic combination shows a four-fold improvement in the chromatic aberration correction range compared to an achromatic doublet configuration. Thus, apochromatic X-ray optics have the potential to increase the focal spot intensity for a wide variety of X-ray applications.

3.
Opt Express ; 31(2): 2977-2988, 2023 Jan 16.
Artigo em Inglês | MEDLINE | ID: mdl-36785299

RESUMO

In a full-field transmission X-ray microscopy (TXM) setup, a condenser X-ray optical element is used to illuminate the sample by condensing the X-ray beam delivered by the synchrotron storage ring. On-going and future upgrades of synchrotron facilities to diffraction-limited storage rings will pose new challenges to these TXM setups, such as much smaller X-ray beams on the condenser. Here, we demonstrate that a refractive axicon can be used as an X-ray beam shaper to match the ring-shaped aperture of the condenser. Aiming at more efficient use of the incoming X-ray intensity, we explore several axicon designs both analytically and with numerical simulations. The axicons were produced by two-photon polymerization 3D printing on thin silicon nitride membrane substrates. The first characterization of the axicon was carried out at the TOMCAT beamline of the Swiss Light Source (Switzerland).

4.
Nat Commun ; 13(1): 1305, 2022 Mar 14.
Artigo em Inglês | MEDLINE | ID: mdl-35288546

RESUMO

Diffractive and refractive optical elements have become an integral part of most high-resolution X-ray microscopes. However, they suffer from inherent chromatic aberration. This has to date restricted their use to narrow-bandwidth radiation, essentially limiting such high-resolution X-ray microscopes to high-brightness synchrotron sources. Similar to visible light optics, one way to tackle chromatic aberration is by combining a focusing and a defocusing optic with different dispersive powers. Here, we present the first successful experimental realisation of an X-ray achromat, consisting of a focusing diffractive Fresnel zone plate (FZP) and a defocusing refractive lens (RL). Using scanning transmission X-ray microscopy (STXM) and ptychography, we demonstrate sub-micrometre achromatic focusing over a wide energy range without any focal adjustment. This type of X-ray achromat will overcome previous limitations set by the chromatic aberration of diffractive and refractive optics and paves the way for new applications in spectroscopy and microscopy at broadband X-ray tube sources.

5.
Opt Lett ; 46(15): 3693-3696, 2021 Aug 01.
Artigo em Inglês | MEDLINE | ID: mdl-34329258

RESUMO

The orientation mismatch between the cone beam of an X-ray tube and the grating lines in a flat substrate remains a big challenge for laboratory grating-based X-ray interferometry, since it severely limits the imaging field of view. Here, we fabricated fan-shaped G0 source gratings by modulating the electric field during the deep reactive ion etching of silicon. The gold electroplated fan-shaped G0 grating (3.0 µm pitch) in a 20 keV interferometer improves the uniformity of the field of view with an increase of average visibility from 16.2% to 18.5% and a better angular sensitivity (by a factor 5.8) at the edges.

6.
Micromachines (Basel) ; 12(5)2021 May 07.
Artigo em Inglês | MEDLINE | ID: mdl-34066906

RESUMO

We present a method to produce small pitch gratings for X-ray interferometric imaging applications, allowing the phase sensitivity to be increased and/or the length of the laboratory setup to be minimized. The method is based on fabrication of high aspect ratio silicon microstructures using deep reactive ion etching (Bosch technique) of dense grating arrays and followed by conformal electroplating of Au. We demonstrated that low resistivity Si substrates (<0.01 Ohm·cm) enable the metal seeding layer deposition step to be avoided, which is normally required to initiate the electroplating process. Etching conditions were optimized to realize Si recess structures with a slight bottom tapering, which ensured the void-free Au filling of the trenches. Vapor HF was used to remove the native oxide layer from the Si grating surface prior to electroplating in the cyanide-based Au electrolyte. Fabrication of Au gratings with pitch in the range 1.2-3.0 µm was successfully realized. A substantial improved aspect ratio of 45:1 for a pitch size of 1.2 µm was achieved with respect to the prior art on 4-inch wafer-based technology. The fabricated Au gratings were tested with X-ray interferometers in Talbot-Laue configuration with measured visibility of 13% at an X-ray design energy of 26 keV.

7.
Opt Express ; 29(2): 2049-2064, 2021 Jan 18.
Artigo em Inglês | MEDLINE | ID: mdl-33726406

RESUMO

X-ray phase contrast imaging is a powerful analysis technique for materials science and biomedicine. Here, we report on laboratory grating-based X-ray interferometry employing a microfocus X-ray source and a high Talbot order (35th) asymmetric geometry to achieve high angular sensitivity and high spatial resolution X-ray phase contrast imaging in a compact system (total length <1 m). The detection of very small refractive angles (∼50 nrad) at an interferometer design energy of 19 keV was enabled by combining small period X-ray gratings (1.0, 1.5 and 3.0 µm) and a single-photon counting X-ray detector (75 µm pixel size). The performance of the X-ray interferometer was fully characterized in terms of angular sensitivity and spatial resolution. Finally, the potential of laboratory X-ray phase contrast for biomedical imaging is demonstrated by obtaining high resolution X-ray phase tomographies of a mouse embryo embedded in solid paraffin and a formalin-fixed full-thickness sample of human left ventricle in water with a spatial resolution of 21.5 µm.


Assuntos
Embrião de Mamíferos/diagnóstico por imagem , Ventrículos do Coração/diagnóstico por imagem , Interferometria/instrumentação , Microscopia de Contraste de Fase/instrumentação , Tomografia Computadorizada por Raios X/métodos , Animais , Desenho de Equipamento , Humanos , Processamento de Imagem Assistida por Computador/métodos , Camundongos , Inclusão em Parafina
8.
Nanoscale Horiz ; 5(5): 869-879, 2020 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-32100775

RESUMO

High aspect ratio nanostructuring requires high precision pattern transfer with highly directional etching. In this work, we demonstrate the fabrication of structures with ultra-high aspect ratios (up to 10 000 : 1) in the nanoscale regime (down to 10 nm) by platinum assisted chemical etching of silicon in the gas phase. The etching gas is created by a vapour of water diluted hydrofluoric acid and a continuous air flow, which works both as an oxidizer and as a gas carrier for reactive species. The high reactivity of platinum as a catalyst and the formation of platinum silicide to improve the stability of the catalyst pattern allow a controlled etching. The method has been successfully applied to produce straight nanowires with section size in the range of 10-100 nm and length of hundreds of micrometres, and X-ray optical elements with feature sizes down to 10 nm and etching depth in the range of tens of micrometres. This work opens the possibility of a low cost etching method for stiction-sensitive nanostructures and a large range of applications where silicon high aspect ratio nanostructures and high precision of pattern transfer are required.

9.
MethodsX ; 6: 107-114, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-30656142

RESUMO

This paper reports on light yield enhancement of terbium-doped gadolinium oxysulfide based scintillator screens achieved by coating their substrates with thin layers of a high density and high atomic number material. For this purpose, iridium was chosen and layers of various thicknesses were applied by atomic layer deposition (ALD). We assessed newly developed scintillator screens for neutron absorption, light yield and spatial resolution and compared them to previously used non-iridium-coated scintillator screens. The addition of the iridium layer resulted in 65 % light yield enhancement in comparison to uncoated scintillator screens while the spatial resolution and absorption power remained unchanged. Highlights •65 % light yield enhancement of the scintillator light output with preservation of the spatial resolution•Use of atomic layer deposition for nanoengineering of the neutron sensitive scintillator screens.

10.
Opt Express ; 25(24): 30686-30695, 2017 Nov 27.
Artigo em Inglês | MEDLINE | ID: mdl-29221096

RESUMO

High resolution metrology of beam profiles is presently a major challenge at X-ray free electron lasers. We demonstrate a characterization method based on beam imprints in poly (methyl methacrylate). By immersing the imprints formed at 47.8 eV into organic solvents, the regions exposed to the beam are removed similar to resist development in grayscale lithography. This allows for extending the sensitivity of the method by more than an order of magnitude compared to the established analysis of imprints created solely by ablation. Applying the Beer-Lambert law for absorption, the intensity distribution in a micron-sized focus can be reconstructed from one single shot with a high dynamic range, exceeding 103. The procedure described here allows for beam characterization at free electron lasers revealing even faint beam tails, which are not accessible when using ablation imprint methods. We demonstrate the greatly extended dynamic range on developed imprints taken in focus of conventional Fresnel zone plates and spiral zone plates producing beams with a topological charge.

11.
Biomed Opt Express ; 8(2): 1257-1270, 2017 Feb 01.
Artigo em Inglês | MEDLINE | ID: mdl-28271016

RESUMO

The high-throughput 3D visualisation of biological specimens is essential for studying diseases and developmental disorders. It requires imaging methods that deliver high-contrast, high-resolution volumetric information at short sample preparation and acquisition times. Here we show that X-ray phase-contrast tomography using a single grating can provide a powerful alternative to commonly employed techniques, such as high-resolution episcopic microscopy (HREM). We present the phase tomography of a mouse embryo in paraffin obtained with an X-ray single-grating interferometer at I13-2 Beamline at Diamond Light Source and discuss the results in comparison with HREM measurements. The excellent contrast and quantitative density information achieved non-destructively and without staining using a simple, robust setup make X-ray single-grating interferometry an optimum candidate for high-throughput imaging of biological specimens as an alternative for existing methods like HREM.

12.
J Vis Exp ; (120)2017 02 21.
Artigo em Inglês | MEDLINE | ID: mdl-28287529

RESUMO

Underground storage permanence is a major concern for carbon capture and storage. Pumping CO2 into carbonate reservoirs has the potential to dissolve geologic seals and allow CO2 to escape. However, the dissolution processes at reservoir conditions are poorly understood. Thus, time-resolved experiments are needed to observe and predict the nature and rate of dissolution at the pore scale. Synchrotron fast tomography is a method of taking high-resolution time-resolved images of complex pore structures much more quickly than traditional µ-CT. The Diamond Lightsource Pink Beam was used to dynamically image dissolution of limestone in the presence of CO2-saturated brine at reservoir conditions. 100 scans were taken at a 6.1 µm resolution over a period of 2 hours. The images were segmented and the porosity and permeability were measured using image analysis and network extraction. Porosity increased uniformly along the length of the sample; however, the rate of increase of both porosity and permeability slowed at later times.


Assuntos
Carbonato de Cálcio/química , Dióxido de Carbono/análise , Carbonatos/análise , Síncrotrons , Tomografia Computadorizada por Raios X/métodos , Porosidade
13.
Nat Commun ; 7: 13367, 2016 11 18.
Artigo em Inglês | MEDLINE | ID: mdl-27857061

RESUMO

Phase retrieval is a long-standing problem in imaging when only the intensity of the wavefield can be recorded. Coherent diffraction imaging is a lensless technique that uses iterative algorithms to recover amplitude and phase contrast images from diffraction intensity data. For general samples, phase retrieval from a single-diffraction pattern has been an algorithmic and experimental challenge. Here we report a method of phase retrieval that uses a known modulation of the sample exit wave. This coherent modulation imaging method removes inherent ambiguities of coherent diffraction imaging and uses a reliable, rapidly converging iterative algorithm involving three planes. It works for extended samples, does not require tight support for convergence and relaxes dynamic range requirements on the detector. Coherent modulation imaging provides a robust method for imaging in materials and biological science, while its single-shot capability will benefit the investigation of dynamical processes with pulsed sources, such as X-ray free-electron lasers.

14.
Microsc Microanal ; 21(2): 290-7, 2015 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-25740406

RESUMO

The oxidation of nickel powder under a controlled gas and temperature environment was studied using synchrotron-based full-field transmission X-ray microscopy. The use of this technique allowed for the reaction to be imaged in situ at 55 nm resolution. The setup was designed to fit in the limited working distance of the microscope and to provide the gas and temperature environments analogous to solid oxide fuel cell operating conditions. Chemical conversion from nickel to nickel oxide was confirmed using X-ray absorption near-edge structure. Using an unreacted core model, the reaction rate as a function of temperature and activation energy were calculated. This method can be applied to study many other chemical reactions requiring similar environmental conditions.

15.
Chem Commun (Camb) ; 51(2): 266-8, 2015.
Artigo em Inglês | MEDLINE | ID: mdl-24898258

RESUMO

The electrodeposition of metallic lithium is a major cause of failure in lithium batteries. The 3D microstructure of electrodeposited lithium 'moss' in liquid electrolytes has been characterised at sub-micron resolution for the first time. Using synchrotron X-ray phase contrast imaging we distinguish mossy metallic lithium microstructures from high surface area lithium salt formations by their contrasting X-ray attenuation.


Assuntos
Galvanoplastia , Imageamento Tridimensional , Lítio/química , Galvanoplastia/métodos , Imageamento Tridimensional/métodos , Síncrotrons , Raios X
16.
Opt Express ; 22(23): 28142-53, 2014 Nov 17.
Artigo em Inglês | MEDLINE | ID: mdl-25402054

RESUMO

Focusing efficiency of Fresnel zone plates (FZPs) for X-rays depends on zone height, while the achievable spatial resolution depends on the width of the finest zones. FZPs with optimal efficiency and sub-100-nm spatial resolution require high aspect ratio structures which are difficult to fabricate with current technology especially for the hard X-ray regime. A possible solution is to stack several zone plates. To increase the number of FZPs within one stack, we first demonstrate intermediate-field stacking and apply this method by stacks of up to five FZPs with adjusted diameters. Approaching the respective optimum zone height, we maximized efficiencies for high resolution focusing at three different energies, 10, 11.8, and 25 keV.


Assuntos
Lentes , Refratometria/instrumentação , Espalhamento de Radiação , Difração de Raios X/instrumentação , Desenho de Equipamento , Raios X
17.
J Synchrotron Radiat ; 21(Pt 6): 1252-61, 2014 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-25343792

RESUMO

Novel X-ray imaging of structural domains in a ferroelectric epitaxial thin film using diffraction contrast is presented. The full-field hard X-ray microscope uses the surface scattering signal, in a reflectivity or diffraction experiment, to spatially resolve the local structure with 70 nm lateral spatial resolution and sub-nanometer height sensitivity. Sub-second X-ray exposures can be used to acquire a 14 µm × 14 µm image with an effective pixel size of 20 nm on the sample. The optical configuration and various engineering considerations that are necessary to achieve optimal imaging resolution and contrast in this type of microscopy are discussed.

18.
Muscles Ligaments Tendons J ; 4(2): 238-44, 2014 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-25332942

RESUMO

The effect of phosphotungstic acid (PTA) and iodine solution (IKI) staining was investigated as a method of enhancing contrast in the X-ray computed tomography of porcine anterior cruciate ligaments (ACL) and patellar tendons (PT). We show that PTA enhanced surface contrast, but was ineffective at penetrating samples, whereas IKI penetrated more effectively and enhanced contrast after 70 hours of staining. Contrast enhancement was compared when using laboratory and synchrotron based X-ray sources. Using the laboratory source, PT fascicles were tracked and their alignment was measured. Individual ACL fascicles could not be identified, but identifiable features were evident that were tracked. Higher resolution scans of fascicle bundles from the PT and ACL were obtained using synchrotron imaging techniques. These scans exhibited greater contrast between the fascicles and matrix in the PT sample, facilitating the identification of the fascicle edges; however, it was still not possible to detect individual fascicles in the ACL.

19.
Sci Rep ; 4: 5246, 2014 Jun 10.
Artigo em Inglês | MEDLINE | ID: mdl-24912978

RESUMO

Following exposure to ppm-level hydrogen sulfide at elevated temperatures, a section of a solid oxide fuel cell (SOFC) Ni-YSZ anode was examined using a combination of synchrotron-based x-ray nanotomography and x-ray fluorescence techniques. While fluorescence measurements provided elemental identification and coarse spatial mapping, x-ray nanotomography was used to map the detailed 3-D spatial distribution of Ni, YSZ, and a nickel-sulfur poisoning phase. The nickel-sulfur layer was found to form a scale covering most of the exposed nickel surface, blocking most fuel reformation and hydrogen oxidation reaction sites. Although the exposure conditions precluded the ability to develop a detailed kinetic description of the nickel-sulfur phase formation, the results provide strong evidence of the detrimental effects of 100 ppm hydrogen sulfide on typical Ni-YSZ anode materials.

20.
Biophys J ; 106(2): 459-66, 2014 Jan 21.
Artigo em Inglês | MEDLINE | ID: mdl-24461021

RESUMO

The characterization of the structure of highly hierarchical biosamples such as collagen-based tissues at the scale of tens of nanometers is essential to correlate the tissue structure with its growth processes. Coherent x-ray Bragg ptychography is an innovative imaging technique that gives high resolution images of the ordered parts of such samples. Herein, we report how we used this method to image the collagen fibrillar ultrastructure of intact rat tail tendons. The images show ordered fibrils extending over 10-20 µm in length, with a quantifiable D-banding spacing variation of 0.2%. Occasional defects in the fibrils distribution have also been observed, likely indicating fibrillar fusion events.


Assuntos
Colágenos Fibrilares/metabolismo , Imagem Molecular/métodos , Tendões/metabolismo , Algoritmos , Animais , Processamento de Imagem Assistida por Computador , Ratos , Difração de Raios X , Raios X
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...