Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 1 de 1
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Index enferm ; 30(3)jul.-sep. 2021. tab, graf
Artigo em Espanhol | IBECS | ID: ibc-221883

RESUMO

Objetivo principal: Medir los efectos del decúbito prono sobre los parámetros ventilatorios en el tratamiento de pacientes con síndrome respiratorio agudo secundario a COVID-19. Metodología: Estudio descriptivo, transversal, prospectivo, se analizaron 103 pacientes con síndrome respiratorio agudo secundario (SDRA) a COVID-19. Se colocó a los pacientes en decúbito prono (DP) por 16 horas continuas y se monitorizaron parámetros ventilatorios como presión arterial de oxígeno (PaO2), saturación de oxígeno (SatO2) y relación entre presión parcial de oxígeno y fracción inspirada de oxígeno (PaO2/FiO2). Resultados principales: La concentración de FiO2 disminuyó de 100% en posición supina a 69% en prono, la PaO2/FiO2 se incrementó de 74 a 122 milímetros de mercurio (mmHg), la PaO2 basal se registró en 51 mmHg y posterior al cambio de posición fue de 89 mmHg, igualmente la SatO2 mejoró de 84% a 93%. Conclusión principal: El DP puede mejorar significativamente los valores de PaO2, SatO2, así como la relación PaO2/FiO2, y en general, el estado clínico del paciente con SDRA. (AU)


Objective: To measure the effects of the prone position on ventilatory parameters in the treatment of patients with acute respiratory syndrome secondary to COVID-19. Methods: Through a descriptive, cross-sectional, prospective study, a sample of 103 patients with acute respiratory syndrome (ARDS) secondary to COVID-19 was studied. The patients were placed in the prone position indefinitely and clinical ventilatory parameters were monitored such as blood pressure oxygen (PaO2), oxygen saturation (SatO2) and relationship between partial pressure of oxygen and inspired fraction of oxygen (PaO2 / FiO2). Results: The concentration of FiO2 decreased from 100% in the supine position to 69% in the prone position, the PaO2 / FiO2 increased from 74 to 122 millimeters of mercury (mmHg), the basal PaO2 was recorded at 51 mmHg and after the change in position it was of 89 mmHg, also the SatO2 improved from 84% to 93%. Conclusions: The prone position can significantly improve the PaO2, SatO2 values, as well as the PaO2 / FiO2 ratio, and in general, the clinical status of the patient with ARDS. (AU)


Assuntos
Humanos , Pandemias , Infecções por Coronavirus/epidemiologia , Síndrome Torácica Aguda/tratamento farmacológico , Decúbito Ventral , Coronavírus Relacionado à Síndrome Respiratória Aguda Grave , Epidemiologia Descritiva , Estudos Transversais , Estudos Prospectivos , México
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...