Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 1 de 1
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
J Heart Valve Dis ; 6(6): 661-5, 1997 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-9427139

RESUMO

BACKGROUND AND AIMS OF THE STUDY: The ATS Medical valve was first implanted in 1992. The purpose of this report was to establish the normal range of each hemodynamic parameter, measured by Doppler echocardiography, in small aortic ATS Medical valves. METHODS: Twenty-five patients with small aortic ATS Medical valves, operated on over six months, and with no cardiac or prosthetic dysfunction, in sinus rhythm, on adequate oral anticoagulant therapy, and no other valve prosthesis or significant valvulopathy, were reviewed on the basis of physical examination and transthoracic Doppler echocardiography. RESULTS: For the aortic 21 Standard ATS Medical valve (n = 10), the following values were registered: peak velocity 2.40 +/- 0.39 m/s; peak gradient 23.7 +/- 6.8 mmHg; mean gradient 12.6 +/- 4.0 mmHg; valve effective orifice area 1.73 +/- 0.41 cm2; Doppler velocity index 0.47 +/- 0.11. For the aortic 19 Standard ATS Medical valve (n = 9), these values were: 3.41 +/- 0.43 m/s; 47.0 +/- 12.6 mmHg; 26.2 +/- 7.9 mmHg; 0.96 +/- 0.18 cm2; and 0.32 +/- 0.06, respectively. For the aortic 16 AP ATS Medical valve (n = 6), these parameters were 3.44 +/- 0.47 m/s; 47.7 +/- 12.0 mmHg; 27.0 +/- 7.3 mmHg; 0.61 +/- 0.09 cm2; and 0.30 +/- 0.04, respectively. CONCLUSIONS: Using Doppler echocardiography, the present study establishes the normal range of parameters which define the hemodynamic performance of the aortic 21 and 19 Standard and 16 AP ATS Medical valves, and demonstrates satisfactory hemodynamic performance of the aortic 21 and 19 Standard ATS Medical valves. It should be noted that the valve effective orifice area determined for the aortic 16 AP ATS Medical valve was smaller than that for the aortic 19 Standard ATS Medical valve, though these two prostheses have the same physical orifice area.


Assuntos
Valva Aórtica/fisiopatologia , Doenças das Valvas Cardíacas/fisiopatologia , Próteses Valvulares Cardíacas , Hemodinâmica/fisiologia , Adulto , Idoso , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Ecocardiografia Doppler , Feminino , Seguimentos , Doenças das Valvas Cardíacas/diagnóstico por imagem , Doenças das Valvas Cardíacas/cirurgia , Próteses Valvulares Cardíacas/normas , Implante de Prótese de Valva Cardíaca , Humanos , Masculino , Pessoa de Meia-Idade , Desenho de Prótese , Estudos Retrospectivos , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...