Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
1.
Artigo em Inglês | MEDLINE | ID: mdl-24396835

RESUMO

This multicenter case series introduces an innovative ultrasonic implant site preparation (UISP) technique as an alternative to the use of traditional rotary instruments. A total of 3,579 implants were inserted in 1,885 subjects, and the sites were prepared using a specific ultrasonic device with a 1- to 3-year follow-up. No surgical complications related to the UISP protocol were reported for any of the implant sites. Seventy-eight implants (59 maxillary, 19 mandibular) failed within 5 months of insertion, for an overall osseointegration percentage of 97.82% (97.14% maxilla, 98.75% mandible). Three maxillary implants failed after 3 years of loading, with an overall implant survival rate of 97.74% (96.99% maxilla, 98.75% mandible).


Assuntos
Implantes Dentários , Piezocirurgia , Humanos
2.
Int J Periodontics Restorative Dent ; 30(4): 415-24, 2010 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-20664844

RESUMO

The purpose of this study was to present a new laboratory technique for cementable implant-supported restorations and to evaluate its efficacy in reducing chair time for both patients and clinicians, while maintaining the precision of an indirect procedure for crown fabrication. The technique consisted of the duplication of the implant portion of a working cast prepared using double-pour or plastic base die systems for single or multiple crowns. For this purpose, a flask previously intended for the production of ceramic inlays and onlays was used. Duplication was obtained using a high-precision addition silicon material and a low-shrinkage polyurethane resin. The duplicated implant abutment was used to finalize the fixed partial denture restorations after the originals were delivered to the patients. Fifty abutments were tested consecutively. The castings (19 single crowns, 31 fixed partial dentures) produced on the original abutments were seated on the duplicate abutments and evaluated by two prosthodontists and two dental technicians using a visual inspection method (laboratory microscope at 163 magnification). Forty-eight restorations were "good" (completely seated, no marginal opening) and 2 were "acceptable" (incomplete seating but amendable), with a 98% success rate. The technique presented demonstrates efficacy and predictability in reducing the number of clinical sessions for delivering precisely fitting cementable implant-supported restorations.


Assuntos
Cimentação , Dente Suporte , Implantes Dentários , Planejamento de Prótese Dentária , Prótese Dentária Fixada por Implante , Coroas , Implantes Dentários para Um Único Dente , Materiais para Moldagem Odontológica/química , Adaptação Marginal Dentária , Planejamento de Dentadura , Prótese Parcial Fixa , Humanos , Teste de Materiais , Ligas Metalo-Cerâmicas/química , Poliuretanos/química , Silício/química , Propriedades de Superfície , Tecnologia Odontológica
3.
J Periodontol ; 81(4): 493-501, 2010 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-20367092

RESUMO

BACKGROUND: The dual acid-etched (DAE) implant was commercially introduced in 1996 with a hybrid design incorporating a machined surface in the coronal region from approximately the third thread to the seating surface. This design was intended to reduce the risks of peri-implantitis and other related soft tissue complications that were reported for implants with surface roughness in the coronal region. The objective of this prospective, randomized-controlled clinical trial was to determine the incidence of peri-implantitis for a fully etched implant with the DAE surface extending to the implant platform. METHODS: Patients had implant sites randomly assigned to receive one hybrid control implant and at least one fully etched test implant in support of a short-span fixed restoration to ensure that variables (e.g., demographics, jaw locations, and bone density) were consistent between groups. Prostheses were inserted 2 months after implant placement with follow-up evaluations scheduled annually for 5 years to assess mucosal health based on bleeding on probing, suppuration, and probing depths. Evaluations also included radiographic and mobility assessments. RESULTS: One hundred twelve patients who were enrolled at seven centers received 139 control and 165 test implants (total: 304 implants). With >5 years of postloading evaluations, there was one declaration of peri-implantitis associated with a control implant that was successfully treated later. Clinical probing and radiographic assessments did not reveal differences between groups in mucosal health outcomes or other signs of peri-implantitis. CONCLUSION: Five-year results of this randomized-controlled study showed no increased risk of peri-implantitis for fully etched implants compared to hybrid-designed implants.


Assuntos
Condicionamento Ácido do Dente/métodos , Implantes Dentários/efeitos adversos , Periodontite/etiologia , Infecções Relacionadas à Prótese/etiologia , Adulto , Idoso , Idoso de 80 Anos ou mais , Perda do Osso Alveolar/diagnóstico por imagem , Distribuição de Qui-Quadrado , Implantação Dentária Endóssea/efeitos adversos , Implantação Dentária Endóssea/métodos , Polimento Dentário , Prótese Dentária Fixada por Implante/efeitos adversos , Falha de Restauração Dentária , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Radiografia , Espectroscopia de Infravermelho com Transformada de Fourier , Propriedades de Superfície , Adulto Jovem
4.
Clin Implant Dent Relat Res ; 12 Suppl 1: e47-55, 2010 May.
Artigo em Inglês | MEDLINE | ID: mdl-19438938

RESUMO

BACKGROUND: Clinical studies reporting immediate loading of endosseous implants for edentulous cases and for fixed partial restorations have been well documented with satisfactory survival rates. Implants with a recently developed, nanometer-scale surface topography (NanoTite, BIOMET 3i, Palm Beach Gardens, FL, USA), created by discrete crystalline depositions (DCD) of calcium phosphate nano-crystals onto a dual acid-etched (DAE) surface, show enhanced early fixation in preclinical studies when compared with DAE-surfaced implants. These outcomes suggest DCD-surfaced implants may be advantageous for immediate loading approaches. OBJECTIVE: The aim of this prospective, multicenter, observational study is to report clinical outcomes for DCD-surfaced implants placed in immediate functional support of single- and multi-unit restorations according to an immediate loading protocol. MATERIALS AND METHODS: One hundred eighty-five patients enrolled at 15 international study centers received a total of 335 implants supporting 216 immediate provisionalizations consisting of 128 single-tooth restorations and 88 fixed restorations. Of the 335 implants, 77% are located in posterior and 23% in anterior regions with 55.5% of the total in mandibles and 44.5% in maxillae. Patients were evaluated for implant mobility, gingival health, symptomatology, and radiographic outcomes. RESULTS: At the time of this 1-year interim report, a total of 17 failures have been observed in 11 patients, yielding a cumulative survival rate of 94.9%. CONCLUSION: Relative to other prospective, multicenter studies of immediately loaded implants with various surface enhancements, NanoTite implants perform comparatively well when immediately provisionalized with single-tooth and fixed restorations.


Assuntos
Implantes Dentários para Um Único Dente , Planejamento de Prótese Dentária , Falha de Restauração Dentária , Prótese Parcial Imediata , Prótese Parcial Temporária , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Fosfatos de Cálcio , Cimentação , Coroas , Corrosão Dentária , Implantação Dentária Endóssea , Análise do Estresse Dentário , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Nanopartículas , Estudos Prospectivos , Propriedades de Superfície , Fatores de Tempo , Adulto Jovem
5.
Int J Oral Maxillofac Implants ; 20(6): 905-12, 2005.
Artigo em Inglês | MEDLINE | ID: mdl-16392348

RESUMO

PURPOSE: In this multicenter study, the performance of Osseotite implants after a 1-stage surgery and abbreviated healing period of 2 months is reported. The implants were followed for up to 5 years. MATERIALS AND METHODS: Partially or completely edentulous patients treated at 10 private practice centers were included in the study. Oral hygiene was assessed using the plaque index and the gingival index prior to surgery and at recall visits at 6 months, 1, 2, 3, 4, and 5 years after initial loading. Bone density and implant/bone fit were evaluated at the time of surgery. Implants were loaded after a healing period of about 2 months. RESULTS: The mean age of the patients at time of enrollment was 60.4 +/- 13.0 years; 44% (86) of the patients were men and 56% (109) were women. In all, 526 implants were placed, 65.4% in the mandible and 34.6% in the maxilla, with 23.0% placed in anterior locations and 77.0% in the posterior. The cumulative success rate of these 526 implants was 97.9% at 5 years. Eight of the 11 implant failures occurred during nonsubmerged healing prior to prosthetic loading. Provisional restorations were placed at 2.1 +/- 0.5 months, at which time implants were evaluated for mobility, gingival health, symptomology, and radiolucency. The distribution of prosthesis types included 118 single-tooth restorations (118 implants), 134 short-span prostheses (327 implants), and 16 long-span restorations (81 implants). DISCUSSION: The benefits of early loading cannot be fully appreciated if there is a substantive increase in implant failures. In this study, a cumulative success rate greater than 97% was maintained throughout 5 years of observation. CONCLUSION: These results suggest that success can be expected with Osseotite implants after a nonsubmerged reduced healing period of 2 months in this patient population.


Assuntos
Implantação Dentária Endóssea/métodos , Implantes Dentários , Falha de Restauração Dentária , Adulto , Métodos Epidemiológicos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Fatores de Tempo , Suporte de Carga
7.
J Periodontol ; 64 Suppl 11S: 1184-1191, 1993 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-29539701

RESUMO

The use of expanded polytetrafluoroethylene (ePTFE) membranes in the treatment of mucogingival problems such as gingival recession, has been recently described. The major issues raised dealt with creating and maintaining space under the membrane and designing a flap that could be coronally positioned and at the same time capable of maintaining a good blood supply. The authors proposed the use of a trapezoidal flap and some technical space-making solutions, such as the use of a suturing technique and different metal structures to support the membranes. J Periodontol 1993; 64:1184-1191.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...