Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 33
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Proc Natl Acad Sci U S A ; 119(29): e2203199119, 2022 Jul 19.
Artigo em Inglês | MEDLINE | ID: mdl-35858350

RESUMO

Lithium-ion battery (LIB) is a broadly adopted technology for energy storage. With increasing demands to improve the rate capability, cyclability, energy density, safety, and cost efficiency, it is crucial to establish an in-depth understanding of the detailed structural evolution and cell-degradation mechanisms during battery operation. Here, we present a laboratory-based high-resolution and high-throughput X-ray micro-computed laminography approach, which is capable of in situ visualizing of an industry-relevant lithium-ion (Li-ion) pouch cell with superior detection fidelity, resolution, and reliability. This technique enables imaging of the pouch cell at a spatial resolution of 0.5 µm in a laboratory system and permits the identification of submicron features within cathode and anode electrodes. We also demonstrate direct visualization of the lithium plating in the imaged pouch cell, which is an important phenomenon relevant to battery fast charging and low-temperature cycling. Our development presents an avenue toward a thorough understanding of the correlation among multiscale structures, chemomechanical degradation, and electrochemical behavior of industry-scale battery pouch cells.

2.
Proc Natl Acad Sci U S A ; 118(25)2021 06 22.
Artigo em Inglês | MEDLINE | ID: mdl-34140413

RESUMO

Multicontrast X-ray imaging with high resolution and sensitivity using Talbot-Lau interferometry (TLI) offers unique imaging capabilities that are important to a wide range of applications, including the study of morphological features with different physical properties in biological specimens. The conventional X-ray TLI approach relies on an absorption grating to create an array of micrometer-sized X-ray sources, posing numerous limitations, including technical challenges associated with grating fabrication for high-energy operations. We overcome these limitations by developing a TLI system with a microarray anode-structured target (MAAST) source. The MAAST features an array of precisely controlled microstructured metal inserts embedded in a diamond substrate. Using this TLI system, tomography of a Drum fish tooth with high resolution and tri-contrast (absorption, phase, and scattering) reveals useful complementary structural information that is inaccessible otherwise. The results highlight the exceptional capability of high-resolution multicontrast X-ray tomography empowered by the MAAST-based TLI method in biomedical applications.


Assuntos
Tomografia Computadorizada por Raios X , Animais , Análise de Dados , Eletrodos , Peixes/anatomia & histologia , Imageamento Tridimensional , Interferometria , Iluminação , Dente/anatomia & histologia , Dente/diagnóstico por imagem
3.
Sci Rep ; 10(1): 9919, 2020 06 18.
Artigo em Inglês | MEDLINE | ID: mdl-32555373

RESUMO

Our future bioeconomy depends on increased utilization of renewable lignocellulosic biomass. Controlling the diffusion of chemicals, such as inorganic ions, within secondary plant cell walls is central to many biomass applications. However, insufficient understanding of intra-cell-wall diffusion within secondary plant cell walls is hindering the advancement of many lignocellulosic biomass applications. In this work, X-ray fluorescence microscopy was used to measure diffusion constants of K+, Cu2+, and Cl- diffusing through loblolly pine (Pinus taeda) cell wall layers under 70%, 75%, or 80% relative humidity (RH). Results revealed that diffusion constants increased with RH, the larger Cu2+ diffused more slowly than the K+, and the Cl- diffusion constant was the same as that for the counter cation, indicating cations and anions diffused together to maintain charge neutrality. Comparison with electrical conductivity measurements showed that conductivity is being controlled by ion mobility over these RH. The results further support that intra-cell-wall diffusion of inorganic ions is a Fickian diffusion process occurring through rubbery amorphous polysaccharides, which contradicts previous assertions that intra-cell-wall diffusion is an aqueous process occurring through water pathways. Researchers can now utilize polymer science approaches to engineer the molecular architecture of lignocellulosic biomass to optimize properties for specific end uses.

4.
Phys Med Biol ; 65(3): 035008, 2020 02 04.
Artigo em Inglês | MEDLINE | ID: mdl-31874460

RESUMO

Talbot-Lau interferometry (TLI) provides additional contrast modes for x-ray imaging that are complementary to conventional absorption radiography. TLI is particularly interesting because it is one of the few practical methods for realizing phase contrast with x-rays that is compatible with large-spot high power x-ray sources. A novel micro array anode structured target (MAAST) x-ray source offers several advantages for TLI over the conventional combination of an extended x-ray source coupled with an absorption grating including higher flux and larger field of view, and these advantages become more pronounced for x-ray energies in excess of 30 keV. A Monte Carlo simulation was performed to determine the optimal parameters for a MAAST source for use with TLI. It was found that the both spatial distribution of x-ray production and the number of x-ray produced in the MAAST have a strong dependence on the incidence angle of the electron beam.


Assuntos
Eletrodos , Processamento de Imagem Assistida por Computador/métodos , Interferometria/instrumentação , Interferometria/métodos , Radiografia/métodos , Humanos , Modelos Teóricos , Método de Monte Carlo , Raios X
5.
Rev Sci Instrum ; 90(8): 083701, 2019 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-31472643

RESUMO

Motivated by the advanced photon source upgrade, a new hard X-ray microscope called "Velociprobe" has been recently designed and built for fast ptychographic imaging with high spatial resolution. We are addressing the challenges of high-resolution and fast scanning with novel hardware designs, advanced motion controls, and new data acquisition strategies, including the use of high-bandwidth interferometric measurements. The use of granite, air-bearing-supported stages provides the necessary long travel ranges for coarse motion to accommodate real samples and variable energy operation while remaining highly stable during fine scanning. Scanning the low-mass zone plate enables high-speed and high-precision motion of the probe over the sample. With an advanced control algorithm implemented in a closed-loop feedback system, the setup achieves a position resolution (3σ) of 2 nm. The instrument performance is evaluated by 2D fly-scan ptychography with our developed data acquisition strategies. A spatial resolution of 8.8 nm has been demonstrated on a Au test sample with a detector continuous frame rate of 200 Hz. Using a higher flux X-ray source provided by double-multilayer monochromator, we achieve 10 nm resolution for an integrated circuit sample in an ultrafast scan with a detector's full continuous frame rate of 3000 Hz (0.33 ms per exposure), resulting in an outstanding imaging rate of 9 × 104 resolution elements per second.

6.
Phys Med Biol ; 64(14): 145011, 2019 07 16.
Artigo em Inglês | MEDLINE | ID: mdl-31163408

RESUMO

Talbot-Lau grating interferometer (TLGI) has great advantages in x-ray imaging contrasts, especially for low-Z materials, over conventional absorption contrast. A microstructured array anode target (MAAT) source offers significantly higher imaging throughput than the combination of an extended x-ray source paired with an absorption grating (also known as source grating). The performance of the MAAT source can be optimized with respect to the areal density, dimensions, and choice of material for the microstructured metal inserts (MMI) and the substrate in which they are embedded. In this paper, we analyze the x-ray generation efficiency per incident electron, relative fraction of x-rays generated by MMI and substrate, x-ray spectrum, and angular distribution via Monte Carlo simulation. Based on the simulation results, the optimal parameters are obtained for a MAAT with incident electron energies from 30 keV to 120 keV. The corresponding temperature distribution within the MAAT is also simulated for the optimal set of the parameters via finite element analysis. As demonstrated by the thermal analysis data, the maximum allowable electron-beam power loading was derived that allows a stable operation of the transmission MAAT.


Assuntos
Interferometria/instrumentação , Interferometria/normas , Modelos Teóricos , Imagem Molecular/métodos , Método de Monte Carlo , Difração de Raios X/instrumentação , Simulação por Computador , Eletrodos , Desenho de Equipamento , Interferometria/métodos
7.
Chem Commun (Camb) ; 55(8): 1052-1055, 2019 Jan 25.
Artigo em Inglês | MEDLINE | ID: mdl-30608504

RESUMO

Biological X-ray fluorescence microscopy (XFM) is an important tool for determining quantitative distributions of bioinorganics and essential trace elements. Here we present a new analysis approach for rapid nanoscale ptychographic imaging and simultaneous chemical mapping of large radiation sensitive specimens without image degradation associated with probe evolution.

8.
Angew Chem Int Ed Engl ; 57(37): 11957-11962, 2018 Sep 10.
Artigo em Inglês | MEDLINE | ID: mdl-30070756

RESUMO

A state-of-the-art operando spectroscopic technique is applied to Co/TiO2 catalysts, which account for nearly half of the world's transportation fuels produced by Fischer-Tropsch catalysis. This allows determination of, at a spatial resolution of approximately 50 nm, the interdependence of formed hydrocarbon species in the inorganic catalyst. Observed trends show intra- and interparticular heterogeneities previously believed not to occur in particles under 200 µm. These heterogeneities are strongly dependent on changes in H2 /CO ratio, but also on changes thereby induced on the Co and Ti valence states. We have captured the genesis of an active FTS particle over its propagation to steady-state operation, in which microgradients lead to the gradual saturation of the Co/TiO2 catalyst surface with long chain hydrocarbons (i.e., organic film formation).

9.
Environ Sci Pollut Res Int ; 25(17): 16427-16433, 2018 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-28940161

RESUMO

Animal studies show that exposure to the environmental pollutant 3,3',4,4',5-pentachlorobiphenyl (PCB126) causes alterations in hepatic metals as measured in acid-digested volume-adjusted tissue. These studies lack the detail of the spatial distribution within the liver. Here we use X-ray fluorescence microscopy (XFM) to assess the spatial distribution of trace elements within liver tissue. Liver samples from male Sprague Dawley rats, treated either with vehicle or PCB126, were formalin fixed and paraffin embedded. Serial sections were prepared for traditional H&E staining or placed on silicon nitride windows for XFM. With XFM, metal gradients between the portal triad and the central vein were seen, especially with copper and iron. These gradients change with exposure to PCB126, even reverse. This is the first report of how micronutrients vary spatially within the liver and how they change in response to toxicant exposure. In addition, high concentrations of zinc clusters were discovered in the extracellular space. PCB126 treatment did not affect their presence, but did alter their elemental makeup suggesting a more general biological function. Further work is needed to properly evaluate the gradients and their alterations as well as classify the zinc clusters to determine their role in liver function and zinc homeostasis.


Assuntos
Cobre/química , Ferro/química , Metais/química , Micronutrientes/química , Bifenilos Policlorados/química , Oligoelementos/química , Zinco/química , Animais , Cobre/metabolismo , Homeostase , Ferro/metabolismo , Fígado , Micronutrientes/metabolismo , Bifenilos Policlorados/metabolismo , Ratos , Ratos Sprague-Dawley , Zinco/metabolismo
10.
Nat Commun ; 8(1): 2091, 2017 12 12.
Artigo em Inglês | MEDLINE | ID: mdl-29233965

RESUMO

Lithium-rich layered transition metal oxide positive electrodes offer access to anion redox at high potentials, thereby promising high energy densities for lithium-ion batteries. However, anion redox is also associated with several unfavorable electrochemical properties, such as open-circuit voltage hysteresis. Here we reveal that in Li1.17-x Ni0.21Co0.08Mn0.54O2, these properties arise from a strong coupling between anion redox and cation migration. We combine various X-ray spectroscopic, microscopic, and structural probes to show that partially reversible transition metal migration decreases the potential of the bulk oxygen redox couple by > 1 V, leading to a reordering in the anionic and cationic redox potentials during cycling. First principles calculations show that this is due to the drastic change in the local oxygen coordination environments associated with the transition metal migration. We propose that this mechanism is involved in stabilizing the oxygen redox couple, which we observe spectroscopically to persist for 500 charge/discharge cycles.

11.
Nat Commun ; 8(1): 658, 2017 09 22.
Artigo em Inglês | MEDLINE | ID: mdl-28939848

RESUMO

Negative differential resistance behavior in oxide memristors, especially those using NbO2, is gaining renewed interest because of its potential utility in neuromorphic computing. However, there has been a decade-long controversy over whether the negative differential resistance is caused by a relatively low-temperature non-linear transport mechanism or a high-temperature Mott transition. Resolving this issue will enable consistent and robust predictive modeling of this phenomenon for different applications. Here we examine NbO2 memristors that exhibit both a current-controlled and a temperature-controlled negative differential resistance. Through thermal and chemical spectromicroscopy and numerical simulations, we confirm that the former is caused by a ~400 K non-linear-transport-driven instability and the latter is caused by the ~1000 K Mott metal-insulator transition, for which the thermal conductance counter-intuitively decreases in the metallic state relative to the insulating state.The development of future computation devices will be aided by a better understanding of the physics underlying material behaviors. Using thermoreflectance and spatially resolved X-ray microscopy, Kumar et al. elucidate the origin of two types of negative differential resistance in NbO2 memristors.

12.
Sci Rep ; 7(1): 445, 2017 03 27.
Artigo em Inglês | MEDLINE | ID: mdl-28348401

RESUMO

X-ray microscopy can be used to image whole, unsectioned cells in their native hydrated state. It complements the higher resolution of electron microscopy for submicrometer thick specimens, and the molecule-specific imaging capabilites of fluorescence light microscopy. We describe here the first use of fast, continuous x-ray scanning of frozen hydrated cells for simultaneous sub-20 nm resolution ptychographic transmission imaging with high contrast, and sub-100 nm resolution deconvolved x-ray fluorescence imaging of diffusible and bound ions at native concentrations, without the need to add specific labels. By working with cells that have been rapidly frozen without the use of chemical fixatives, and imaging them under cryogenic conditions, we are able to obtain images with well preserved structural and chemical composition, and sufficient stability against radiation damage to allow for multiple images to be obtained with no observable change.


Assuntos
Congelamento , Processamento de Imagem Assistida por Computador , Microscopia de Fluorescência/métodos , Água/química , Chlamydomonas/citologia , Raios X
13.
Sci Rep ; 7: 41798, 2017 01 31.
Artigo em Inglês | MEDLINE | ID: mdl-28139778

RESUMO

The role of ions in the fungal decay process of lignocellulose biomaterials, and more broadly fungal metabolism, has implications for diverse research disciplines ranging from plant pathology and forest ecology, to carbon sequestration. Despite the importance of ions in fungal decay mechanisms, the spatial distribution and quantification of ions in lignocellulosic cell walls and fungal hyphae during decay is not known. Here we employ synchrotron-based X-ray fluorescence microscopy (XFM) to map and quantify physiologically relevant ions, such as K, Ca, Mn, Fe, and Zn, in wood being decayed by the model brown rot fungus Serpula lacrymans. Two-dimensional XFM maps were obtained to study the ion spatial distributions from mm to submicron length scales in wood, fungal hyphae with the dried extracellular matrix (ECM) from the fungus, and Ca oxalate crystals. Three-dimensional ion volume reconstructions were also acquired of wood cell walls and hyphae with ECM. Results show that the fungus actively transports some ions, such as Fe, into the wood and controls the distribution of ions at both the bulk wood and cell wall length scales. These measurements provide new insights into the movement of ions during decay and illustrate how synchrotron-based XFM is uniquely suited study these ions.


Assuntos
Fungos/metabolismo , Íons/metabolismo , Lignina/metabolismo , Microscopia de Fluorescência , Síncrotrons , Raios X , Madeira/química , Madeira/microbiologia
14.
Nanoscale ; 9(5): 1793-1798, 2017 Feb 02.
Artigo em Inglês | MEDLINE | ID: mdl-27906408

RESUMO

We analyzed micrometer-scale titanium-niobium-oxide prototype memristors, which exhibited low write-power (<3 µW) and energy (<200 fJ per bit per µm2), low read-power (∼nW), and high endurance (>millions of cycles). To understand their physico-chemical operating mechanisms, we performed in operando synchrotron X-ray transmission nanoscale spectromicroscopy using an ultra-sensitive time-multiplexed technique. We observed only spatially uniform material changes during cell operation, in sharp contrast to the frequently detected formation of a localized conduction channel in transition-metal-oxide memristors. We also associated the response of assigned spectral features distinctly to non-volatile storage (resistance change) and writing of information (application of voltage and Joule heating). These results provide critical insights into high-performance memristors that will aid in device design, scaling and predictive circuit-modeling, all of which are essential for the widespread deployment of successful memristor applications.

15.
J Microsc ; 265(1): 81-93, 2017 01.
Artigo em Inglês | MEDLINE | ID: mdl-27580164

RESUMO

Trace metals play important roles in biological function, and x-ray fluorescence microscopy (XFM) provides a way to quantitatively image their distribution within cells. The faithfulness of these measurements is dependent on proper sample preparation. Using mouse embryonic fibroblast NIH/3T3 cells as an example, we compare various approaches to the preparation of adherent mammalian cells for XFM imaging under ambient temperature. Direct side-by-side comparison shows that plunge-freezing-based cryoimmobilization provides more faithful preservation than conventional chemical fixation for most biologically important elements including P, S, Cl, K, Fe, Cu, Zn and possibly Ca in adherent mammalian cells. Although cells rinsed with fresh media had a great deal of extracellular background signal for Cl and Ca, this approach maintained cells at the best possible physiological status before rapid freezing and it does not interfere with XFM analysis of other elements. If chemical fixation has to be chosen, the combination of 3% paraformaldehyde and 1.5 % glutaraldehyde preserves S, Fe, Cu and Zn better than either fixative alone. When chemically fixed cells were subjected to a variety of dehydration processes, air drying was proved to be more suitable than other drying methods such as graded ethanol dehydration and freeze drying. This first detailed comparison for x-ray fluorescence microscopy shows how detailed quantitative conclusions can be affected by the choice of cell preparation method.


Assuntos
Fibroblastos/química , Fibroblastos/citologia , Microscopia de Fluorescência/métodos , Espectrometria por Raios X/métodos , Fixação de Tecidos/métodos , Oligoelementos/análise , Animais , Camundongos , Células NIH 3T3
16.
ACS Nano ; 10(12): 11205-11210, 2016 12 27.
Artigo em Inglês | MEDLINE | ID: mdl-27957851

RESUMO

Transition-metal-oxide memristors, or resistive random-access memory (RRAM) switches, are under intense development for storage-class memory because of their favorable operating power, endurance, speed, and density. Their commercial deployment critically depends on predictive compact models based on understanding nanoscale physicochemical forces, which remains elusive and controversial owing to the difficulties in directly observing atomic motions during resistive switching, Here, using scanning transmission synchrotron X-ray spectromicroscopy to study in situ switching of hafnium oxide memristors, we directly observed the formation of a localized oxygen-deficiency-derived conductive channel surrounded by a low-conductivity ring of excess oxygen. Subsequent thermal annealing homogenized the segregated oxygen, resetting the cells toward their as-grown resistance state. We show that the formation and dissolution of the conduction channel are successfully modeled by radial thermophoresis and Fick diffusion of oxygen atoms driven by Joule heating. This confirmation and quantification of two opposing nanoscale radial forces that affect bipolar memristor switching are important components for any future physics-based compact model for the electronic switching of these devices.

17.
J Synchrotron Radiat ; 23(Pt 5): 1151-7, 2016 09 01.
Artigo em Inglês | MEDLINE | ID: mdl-27577770

RESUMO

Owing to its extreme sensitivity, quantitative mapping of elemental distributions via X-ray fluorescence microscopy (XFM) has become a key microanalytical technique. The recent realisation of scanning X-ray diffraction microscopy (SXDM) meanwhile provides an avenue for quantitative super-resolved ultra-structural visualization. The similarity of their experimental geometries indicates excellent prospects for simultaneous acquisition. Here, in both step- and fly-scanning modes, robust, simultaneous XFM-SXDM is demonstrated.

18.
J Synchrotron Radiat ; 23(Pt 5): 1210-5, 2016 09 01.
Artigo em Inglês | MEDLINE | ID: mdl-27577777

RESUMO

Recent progress in the development of dichroic Bragg coherent diffractive imaging, a new technique for simultaneous three-dimensional imaging of strain and magnetization at the nanoscale, is reported. This progress includes the installation of a diamond X-ray phase retarder at beamline 34-ID-C of the Advanced Photon Source. The performance of the phase retarder for tuning X-ray polarization is demonstrated with temperature-dependent X-ray magnetic circular dichroism measurements on a gadolinium foil in transmission and on a Gd5Si2Ge2 crystal in diffraction geometry with a partially coherent, focused X-ray beam. Feasibility tests for dichroic Bragg coherent diffractive imaging are presented. These tests include (1) using conventional Bragg coherent diffractive imaging to determine whether the phase retarder introduces aberrations using a nonmagnetic gold nanocrystal as a control sample, and (2) collecting coherent diffraction patterns of a magnetic Gd5Si2Ge2 nanocrystal with left- and right-circularly polarized X-rays. Future applications of dichroic Bragg coherent diffractive imaging for the correlation of strain and lattice defects with magnetic ordering and inhomogeneities are considered.

19.
Sci Adv ; 2(6): e1600149, 2016 06.
Artigo em Inglês | MEDLINE | ID: mdl-27386575

RESUMO

Many organisms in nature have evolved sophisticated cellular mechanisms to produce photonic nanostructures and, in recent years, diverse crystalline symmetries have been identified and related to macroscopic optical properties. However, because we know little about the distributions of domain sizes, the orientations of photonic crystals, and the nature of defects in these structures, we are unable to make the connection between the nanostructure and its development and functionality. We report on nondestructive studies of the morphology of chitinous photonic crystals in butterfly wing scales. Using spatially and angularly resolved x-ray diffraction, we find that the domains are highly oriented with respect to the whole scale, indicating growth from scale boundaries. X-ray coherent diffractive imaging reveals two types of crystalline domain interfaces: abrupt changes between domains emerging from distinct nucleation sites and smooth transitions with edge dislocations presumably resulting from internal stresses during nanostructure development. Our study of the scale structure reveals new aspects of photonic crystal growth in butterfly wings and shows their similarity to block copolymer materials. It opens new avenues to exploration of fundamental processes underlying the growth of biological photonic nanostructures in a variety of species.


Assuntos
Materiais Biomiméticos/química , Borboletas , Nanoestruturas/química , Fótons , Asas de Animais , Animais , Óptica e Fotônica , Asas de Animais/ultraestrutura , Difração de Raios X
20.
Opt Express ; 23(5): 5438-51, 2015 Mar 09.
Artigo em Inglês | MEDLINE | ID: mdl-25836777

RESUMO

Ptychography is a coherent diffraction imaging (CDI) method for extended objects in which diffraction patterns are acquired sequentially from overlapping coherent illumination spots. The object's complex transmission function can be reconstructed from those diffraction patterns at a spatial resolution limited only by the scattering strength of the object and the detector geometry. Most experiments to date have positioned the illumination spots on the sample using a move-settle-measure sequence in which the move and settle steps can take longer to complete than the measure step. We describe here the use of a continuous "fly-scan" mode for ptychographic data collection in which the sample is moved continuously, so that the experiment resembles one of integrating the diffraction patterns from multiple probe positions. This allows one to use multiple probe mode reconstruction methods to obtain an image of the object and also of the illumination function. We show in simulations, and in x-ray imaging experiments, some of the characteristics of fly-scan ptychography, including a factor of 25 reduction in the data acquisition time. This approach will become increasingly important as brighter x-ray sources are developed, such as diffraction limited storage rings.


Assuntos
Imageamento Tridimensional , Movimento (Física) , Raios X , Animais , Simulação por Computador
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...