1.
J Appl Clin Med Phys ; : e14391, 2024 Jul 10.
Artigo em Inglês | MEDLINE | ID: mdl-38988053

RESUMO

In failure modes and effects analysis (FMEA), the components of the risk priority number (RPN) for a failure mode (FM) are often chosen by consensus. We describe an empirical method for estimating the occurrence (O) and detectability (D) components of a RPN. The method requires for a given FM that its associated quality control measure be performed twice as is the case when a FM is checked for in an initial physics check and again during a weekly physics check. If instances of the FM caught by these checks are recorded, O and D can be computed. Incorporation of the remaining RPN component, Severity, is discussed. This method can be used as part of quality management design ahead of an anticipated FMEA or afterwards to validate consensus values.

2.
Radiat Res ; 197(2): 113-121, 2022 02 01.
Artigo em Inglês | MEDLINE | ID: mdl-34634111

RESUMO

This work seeks to develop standard X-ray beams that are matched to radiobiology X-ray irradiators. The calibration of detectors used for dose determination of these irradiators is performed with a set of standard X rays that are more heavily filtered and/or lower energy, which leads to a higher uncertainty in the dose measurement. Models of the XRad320, SARRP, and the X-ray tube at the University of Wisconsin Medical Radiation Research Center (UWMRRC) were created using the BEAMnrc user code of the EGSnrc Monte Carlo code system. These models were validated against measurements, and the resultant modeled spectra were used to determine the amount of added filtration needed to match the X-ray beams at the UWMRRC to those of the XRad320 and SARRP. The depth profiles and half-value layer (HVL) simulations performed using BEAMnrc agreed to measurements within 3% and 3.6%, respectively. A primary measurement device, a free-air chamber, was developed to measure air kerma in the medium energy range of X rays. The resultant spectra of the matched beams had HVL's that matched the HVL's of the radiobiology irradiators well within the 3% criteria recommended by the International Atomic Energy Agency (IAEA) and the average energies agreed within 2.4%. In conclusion, three standard X-ray beams were developed at the UWMRRC with spectra that more closely match the spectra of the XRad320 and SARRP radiobiology irradiators, which will aid in a more accurate dose determination during calibration of these irradiators.


Assuntos
Método de Monte Carlo
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...