Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 25
Filtrar
1.
Sci Data ; 11(1): 655, 2024 Jun 21.
Artigo em Inglês | MEDLINE | ID: mdl-38906912

RESUMO

We present the INSPIRE dataset, a publicly available research dataset in perioperative medicine, which includes approximately 130,000 surgical operations at an academic institution in South Korea over a ten-year period between 2011 and 2020. This comprehensive dataset includes patient characteristics such as age, sex, American Society of Anesthesiologists physical status classification, diagnosis, surgical procedure code, department, and type of anaesthesia. The dataset also includes vital signs in the operating theatre, general wards, and intensive care units (ICUs), laboratory results from six months before admission to six months after discharge, and medication during hospitalisation. Complications include total hospital and ICU length of stay and in-hospital death. We hope this dataset will inspire collaborative research and development in perioperative medicine and serve as a reproducible external validation dataset to improve surgical outcomes.


Assuntos
Medicina Perioperatória , Humanos , República da Coreia , Unidades de Terapia Intensiva
3.
J Clin Monit Comput ; 37(1): 165-177, 2023 02.
Artigo em Inglês | MEDLINE | ID: mdl-35695942

RESUMO

Common physiological time series and waveforms are composed of repeating cardiac and respiratory cycles. Often, the cardiac effect is the primary interest, but for, e.g., fluid responsiveness prediction, the respiratory effect on arterial blood pressure also convey important information. In either case, it is relevant to disentangle the two effects. Generalized additive models (GAMs) allow estimating the effect of predictors as nonlinear, smooth functions. These smooth functions can represent the cardiac and respiratory cycles' effects on a physiological signal. We demonstrate how GAMs allow a decomposition of physiological signals from mechanically ventilated subjects into separate effects of the cardiac and respiratory cycles. Two examples are presented. The first is a model of the respiratory variation in pulse pressure. The second demonstrates how a central venous pressure waveform can be decomposed into a cardiac effect, a respiratory effect and the interaction between the two cycles. Generalized additive models provide an intuitive and flexible approach to modelling the repeating, smooth, patterns common in medical monitoring data.


Assuntos
Pulmão , Fenômenos Fisiológicos Respiratórios , Humanos , Fatores de Tempo , Pressão Sanguínea/fisiologia , Coração , Respiração Artificial , Hidratação
4.
Anesthesiology ; 137(3): 283-289, 2022 09 01.
Artigo em Inglês | MEDLINE | ID: mdl-35984931

RESUMO

The Hypotension Prediction Index is a proprietary prediction model incorporated into a commercially available intraoperative hemodynamic monitoring system. The Hypotension Prediction Index uses multiple features of the arterial blood pressure waveform to predict hypotension. The index publication introducing the Hypotension Prediction Index describes the selection of training and validation data. Although precise details of the Hypotension Prediction Index algorithm are proprietary, the authors describe a selection process whereby a mean arterial pressure (MAP) less than 75 mmHg will always predict hypotension. We hypothesize that the data selection process introduced a systematic bias that resulted in an overestimation of the current MAP value's ability to predict future hypotension. Since current MAP is a predictive variable contributing to Hypotension Prediction Index, this exaggerated predictive performance likely also applies to the corresponding Hypotension Prediction Index value. Other existing validation studies appear similarly problematic, suggesting that additional validation work and, potentially, updates to the Hypotension Prediction Index model may be necessary.


Assuntos
Hipotensão , Algoritmos , Pressão Arterial/fisiologia , Humanos , Hipotensão/diagnóstico , Monitorização Intraoperatória/métodos , Viés de Seleção
6.
J Clin Monit Comput ; 36(3): 889-900, 2022 06.
Artigo em Inglês | MEDLINE | ID: mdl-34041648

RESUMO

Prediction of fluid responsiveness is essential in perioperative goal directed therapy, but dynamic tests of fluid responsiveness are not applicable during open-chest surgery. We hypothesised that two methods could predict fluid responsiveness during cardiac surgery based on their ability to alter preload and thereby induce changes in arterial blood pressure characteristics: (1) the change caused by extrasystolic beats and (2) the change caused by a fast infusion of 50 ml crystalloid (micro-fluid challenge). Arterial blood pressure and electrocardiogram waveforms were collected during surgical preparation of the left internal mammary artery in patients undergoing coronary artery bypass surgery. Patients received a fluid challenge (5 ml/kg ideal body weight). The first 50 ml were infused in 10 s and comprised the micro-fluid challenge. Predictor variables were defined as post-ectopic beat changes (compared with sinus beats preceding ectopy) in arterial blood pressure characteristics, such as pulse pressure and systolic pressure, or micro-fluid challenge induced changes in the same blood pressure characteristics. Patients were considered fluid responsive if stroke volume index increased by 15% or more after the full fluid challenge. Diagnostic accuracy was calculated by the area under the receiver operating characteristics curve (AUC). Fifty-six patients were included for statistical analysis. Thirty-one had extrasystoles. The maximal AUC was found for the extrasystolic change in pulse pressure and was 0.70 (CI [0.35 to 1.00]). The micro-fluid challenge method generally produced lower AUC point estimates. Extrasystoles did not predict fluid responsiveness with convincing accuracy in patients undergoing cardiac surgery and changes in arterial waveform indices following a micro-fluid challenge could not predict fluid responsiveness. Given a low number of fluid responders and inherently reduced statistical power, our data does not support firm conclusions about the utility of the extrasystolic method. CLINICAL TRIAL REGISTRATION: Unique identifier: NCT02903316. https://clinicaltrials.gov/ct2/show/NCT02903316?cond=NCT02903316&rank=1 .


Assuntos
Pressão Arterial , Procedimentos Cirúrgicos Cardíacos , Pressão Sanguínea , Complexos Cardíacos Prematuros , Débito Cardíaco , Soluções Cristaloides , Hidratação , Hemodinâmica , Humanos , Curva ROC , Volume Sistólico
7.
Acta Anaesthesiol Scand ; 66(1): 17-24, 2022 01.
Artigo em Inglês | MEDLINE | ID: mdl-34338314

RESUMO

BACKGROUND: The mini-fluid challenge (MFC) is a clinical concept of predicting fluid responsiveness by rapidly infusing a small amount of intravenous fluids, typically 100 ml, and systematically assessing its haemodynamic effect. The MFC method is meant to predict if a patient will respond to a subsequent, larger fluid challenge, typically another 400 ml, with a significant increase in stroke volume. METHODS: We critically evaluated the general methodology of MFC studies, with statistical considerations, secondary analysis of an existing study and simulations. RESULTS: Secondary analysis of an existing study showed that the MFC could predict the total fluid response (MFC + 400 ml) with an area under the receiver operator characteristic curve (AUROC) of 0.92, but that the prediction was worse than random for the response to the remaining 400 ml (AUROC = 0.33). In a null simulation with no response to both the MFC and the subsequent fluid challenge, the commonly used analysis could predict fluid responsiveness with an AUROC of 0.73. CONCLUSION: Many existing MFC studies are likely overestimating the classification accuracy of the MFC. This should be considered before adopting the MFC into clinical practice. A better study design includes a second, independent measurement of stroke volume after the MFC. This measurement serves as reference for the response to the subsequent fluid challenge.


Assuntos
Hidratação , Hemodinâmica , Área Sob a Curva , Pressão Sanguínea , Débito Cardíaco , Humanos , Curva ROC , Volume Sistólico
9.
Ann Intensive Care ; 11(1): 21, 2021 Jan 29.
Artigo em Inglês | MEDLINE | ID: mdl-33512597

RESUMO

BACKGROUND: Treatment decisions on critically ill patients with circulatory shock lack consensus. In an international survey, we aimed to evaluate the indications, current practice, and therapeutic goals of inotrope therapy in the treatment of patients with circulatory shock. METHODS: From November 2016 to April 2017, an anonymous web-based survey on the use of cardiovascular drugs was accessible to members of the European Society of Intensive Care Medicine (ESICM). A total of 14 questions focused on the profile of respondents, the triggering factors, first-line choice, dosing, timing, targets, additional treatment strategy, and suggested effect of inotropes. In addition, a group of 42 international ESICM experts was asked to formulate recommendations for the use of inotropes based on 11 questions. RESULTS: A total of 839 physicians from 82 countries responded. Dobutamine was the first-line inotrope in critically ill patients with acute heart failure for 84% of respondents. Two-thirds of respondents (66%) stated to use inotropes when there were persistent clinical signs of hypoperfusion or persistent hyperlactatemia despite a supposed adequate use of fluids and vasopressors, with (44%) or without (22%) the context of low left ventricular ejection fraction. Nearly half (44%) of respondents stated an adequate cardiac output as target for inotropic treatment. The experts agreed on 11 strong recommendations, all of which were based on excellent (> 90%) or good (81-90%) agreement. Recommendations include the indications for inotropes (septic and cardiogenic shock), the choice of drugs (dobutamine, not dopamine), the triggers (low cardiac output and clinical signs of hypoperfusion) and targets (adequate cardiac output) and stopping criteria (adverse effects and clinical improvement). CONCLUSION: Inotrope use in critically ill patients is quite heterogeneous as self-reported by individual caregivers. Eleven strong recommendations on the indications, choice, triggers and targets for the use of inotropes are given by international experts. Future studies should focus on consistent indications for inotrope use and implementation into a guideline for circulatory shock that encompasses individualized targets and outcomes.

12.
J Clin Monit Comput ; 34(2): 245-251, 2020 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-31134474

RESUMO

Near infrared spectroscopy (NIRS) has been used to evaluate regional cerebral tissue oxygen saturation (ScO2) during the last decades. Perioperative management algorithms advocate to maintain ScO2, by maintaining or increasing cardiac output (CO), e.g. with fluid infusion. We hypothesized that ScO2 would increase in responders to a standardized fluid challenge (FC) and that the relative changes in CO and ScO2 would correlate. This study is a retrospective substudy of the FLuid Responsiveness Prediction Using Extra Systoles (FLEX) trial. In the FLEX trial, patients were administered two standardized FCs (5 mL/kg ideal body weight each) during cardiac surgery. NIRS monitoring was used during the intraoperative period and CO was monitored continuously. Patients were considered responders if stroke volume increased more than 10% following FC. Datasets from 29 non-responders and 27 responders to FC were available for analysis. Relative changes of ScO2 did not change significantly in non-responders (mean difference - 0.3% ± 2.3%, p = 0.534) or in fluid responders (mean difference 1.6% ± 4.6%, p = 0.088). Relative changes in CO and ScO2 correlated significantly, p = 0.027. Increasing CO by fluid did not change cerebral oxygenation. Despite this, relative changes in CO correlated to relative changes in ScO2. However, the clinical impact of the present observations is unclear, and the results must be interpreted with caution.Trial registration:http://ClinicalTrial.gov identifier for main study (FLuid Responsiveness Prediction Using Extra Systoles-FLEX): NCT03002129.


Assuntos
Encéfalo/metabolismo , Procedimentos Cirúrgicos Cardíacos , Monitorização Intraoperatória/métodos , Oxigênio/metabolismo , Espectroscopia de Luz Próxima ao Infravermelho/métodos , Idoso , Débito Cardíaco , Ponte Cardiopulmonar , Ponte de Artéria Coronária , Feminino , Hidratação , Monitorização Hemodinâmica , Humanos , Masculino , Pessoa de Meia-Idade , Oximetria/métodos , Estudos Retrospectivos
13.
J Clin Monit Comput ; 34(5): 913-922, 2020 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-31677135

RESUMO

Echocardiographic measurement of cardiac output with automated software analyses of spectral curves in the left ventricular outflow tract has been introduced. This study aimed to assess the precision and accuracy of cardiac output measurements as well as the ability to track cardiac output changes over time comparing the automated echocardiographic method with the continuous pulmonary artery thermodilution cardiac output technique and the manual echocardiographic method in cardiac surgery patients. Cardiac output was measured simultaneously with all three methods in 50 patients on the morning after cardiac surgery. A second comparison was performed 90-180 min later. Precisions for each method were measured. Bias and limits of agreement (LoA) between methods were assessed and concordance- and polar plots were used for evaluating trending of cardiac output. When comparing the automated echocardiographic method with the thermodilution technique, the mean bias was 0.72 L/min with LoA - 1.89; 3.33 L/min corresponding to a percentage error of 46%. The concordance rate was 47%. The mean bias between the automated- and the manual echocardiographic methods was - 0.06 L/min (95% LoA - 2.33; 2.21 L/min, percentage error 42%). The concordance rate was 79%. The automated echocardiographic method did not meet the criteria for interchangeability with the thermodilution technique or the manual echocardiographic method. Trending ability was poor when compared to the continuous thermodilution technique, but moderate when compared to the manual echocardiographic method.Trial registry number: NCT03372863. Retrospectively registered December 14th 2017.


Assuntos
Procedimentos Cirúrgicos Cardíacos , Termodiluição , Débito Cardíaco , Ecocardiografia , Humanos , Artéria Pulmonar
14.
Best Pract Res Clin Anaesthesiol ; 33(2): 165-177, 2019 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-31582096

RESUMO

The impact of positive pressure ventilation extends the effect on lungs and gas exchange because the altered intra-thoracic pressure conditions influence determinants of cardiovascular function. These mechanisms are called heart-lung interactions, which conceptually can be divided into two components (1) The effect of positive airway pressure on the cardiovascular system, which may be more or less pronounced under various pathologic cardiac conditions, and (2) The effect of cyclic airway pressure swing on the cardiovascular system, which can be useful in the interpretation of the individual patient's current haemodynamic state. It is imperative for the anaesthesiologist to understand the fundamental mechanisms of heart-lung interactions, as they are a foundation for the understanding of optimal, personalised cardiovascular treatment of patients undergoing surgery in general anaesthesia. The aim of this review is thus to describe what the anaesthesiologist needs to know about heart-lung interactions.


Assuntos
Anestesiologistas/normas , Competência Clínica/normas , Hemodinâmica/fisiologia , Pulmão/fisiologia , Respiração com Pressão Positiva/normas , Função Ventricular/fisiologia , Pressão Sanguínea/fisiologia , Humanos , Respiração com Pressão Positiva/métodos
16.
J Clin Monit Comput ; 33(2): 211-222, 2019 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-30847738

RESUMO

Hemodynamic management is a mainstay of patient care in the operating room and intensive care unit (ICU). In order to optimize patient treatment, researchers investigate monitoring technologies, cardiovascular (patho-) physiology, and hemodynamic treatment strategies. The Journal of Clinical Monitoring and Computing (JCMC) is a well-established and recognized platform for publishing research in this field. In this review, we highlight recent advancements and summarize selected papers published in the JCMC in 2018 related to hemodynamic monitoring and management.


Assuntos
Monitorização Hemodinâmica/métodos , Hemodinâmica/fisiologia , Monitorização Fisiológica/métodos , Algoritmos , Velocidade do Fluxo Sanguíneo , Pressão Sanguínea , Determinação da Pressão Arterial , Débito Cardíaco , Sistema Cardiovascular , Humanos , Hipotensão , Unidades de Terapia Intensiva , Período Intraoperatório , Salas Cirúrgicas , Publicações Periódicas como Assunto , Período Perioperatório
17.
Ann Intensive Care ; 9(1): 20, 2019 Jan 30.
Artigo em Inglês | MEDLINE | ID: mdl-30701448

RESUMO

BACKGROUND: Vasopressors are commonly applied to restore and maintain blood pressure in patients with sepsis. We aimed to evaluate the current practice and therapeutic goals regarding vasopressor use in septic shock as a basis for future studies and to provide some recommendations on their use. METHODS: From November 2016 to April 2017, an anonymous web-based survey on the use of vasoactive drugs was accessible to members of the European Society of Intensive Care Medicine (ESICM). A total of 17 questions focused on the profile of respondents, triggering factors, first choice agent, dosing, timing, targets, additional treatments, and effects of vasopressors. We investigated whether the answers complied with current guidelines. In addition, a group of 34 international ESICM experts was asked to formulate recommendations for the use of vasopressors based on 6 questions with sub-questions (total 14). RESULTS: A total of 839 physicians from 82 countries (65% main specialty/activity intensive care) responded. The main trigger for vasopressor use was an insufficient mean arterial pressure (MAP) response to initial fluid resuscitation (83%). The first-line vasopressor was norepinephrine (97%), targeting predominantly a MAP > 60-65 mmHg (70%), with higher targets in patients with chronic arterial hypertension (79%). The experts agreed on 10 recommendations, 9 of which were based on unanimous or strong (≥ 80%) agreement. They recommended not to delay vasopressor treatment until fluid resuscitation is completed but rather to start with norepinephrine early to achieve a target MAP of ≥ 65 mmHg. CONCLUSION: Reported vasopressor use in septic shock is compliant with contemporary guidelines. Future studies should focus on individualized treatment targets including earlier use of vasopressors.

18.
J Clin Monit Comput ; 33(5): 777-786, 2019 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-30414054

RESUMO

Fluid responsiveness prediction is difficult during cardiac surgery. The micro-fluid challenge (micro-FC; rapid central infusion of 50 ml) and the extrasystolic method utilising post-extrasystolic preload increases may predict fluid responsiveness. Two study windows during coronary artery bypass graft surgery were defined, 1: After anaesthesia induction until surgical incision, 2: Left internal mammarian artery surgical preparation period. Each window consisted of 10-15 min observation for extrasystoles before a micro-FC was performed, after which a traditional fluid challenge (FC) was performed (5 ml/kg). Extrasystolic and micro-FC induced changes in hemodynamic variables were derived as predictors of fluid responsiveness defined as stroke volume increasing > 10% following FC. 61 patients were studied. Post-ectopic changes in pulse pressure (PP) predicted fluid responsiveness with receiver operating characteristic area (AUC) of 0.69 [CI 0.40;0.97] in the first study window and 0.64 [0.44;0.86] in the second window. Other post-ectopic predictors such as pre-ejection period (PEP) and systolic blood pressure (SBP) had similar or lower AUCs. Heart rate was 52.9 (SD ±8.4) min- 1 and 53.6 (± 8.8) min- 1 in the two study windows. Micro-FC induced changes in PEP had AUC of 0.74 [0.57;0.90] in the first window and 0.60 [0.40;0.76] in the second window. Correcting micro-FC induced changes in PEP for the micro-FC induced changes in heart rate had AUCs of 0.84 [0.70;0.97] in the first window and 0.63 [0.47;0.79] in the second window. The investigated methods revealed insufficient validity during cardiac surgery. RR interval corrected changes during a micro-FC should be investigated further. Trial registration Clinicaltrials.gov: NCT03002129.


Assuntos
Débito Cardíaco , Procedimentos Cirúrgicos Cardíacos/instrumentação , Ponte de Artéria Coronária/instrumentação , Hemodinâmica , Sístole , Idoso , Idoso de 80 Anos ou mais , Área Sob a Curva , Pressão Sanguínea , Feminino , Hidratação , Frequência Cardíaca , Ventrículos do Coração , Humanos , Masculino , Pessoa de Meia-Idade , Oximetria , Estudos Prospectivos , Curva ROC , Respiração Artificial , Volume Sistólico
19.
Crit Care Res Pract ; 2018: 5697092, 2018.
Artigo em Inglês | MEDLINE | ID: mdl-30364006

RESUMO

BACKGROUND: Extrasystoles may be useful for predicting the response to fluid therapy in hemodynamically unstable patients but their prevalence is unknown. The aim of this study was to estimate the availability of extrasystoles in intensive care unit patients diagnosed with sepsis. The study aim was not to validate the fluid responsiveness prediction ability of extrasystoles. METHODS: Twenty-four-hour ECG recordings from a convenience sample of 50 patients diagnosed with sepsis were extracted from the MIMIC-II waveform database, and ECGs were visually examined for correct QRS complex detection. Custom-made algorithms identified potential extrasystoles based on RR intervals. Two raters visually confirmed or rejected the potential extrasystoles and then classified them as ventricular, supraventricular, or unknown origin. Extrasystole availability was calculated as extrasystolic coverage for each 24 h ECG recording, that is, the percentage of the 24 h recording where an extrasystole had occurred in the preceding 30 minutes. RESULTS: Mean extrasystolic coverage was 53.3% (confidence interval: [42.8; 63.6]%) and ventricular extrasystolic coverage was 21.4 [13.5; 29.8]%. Interrater reliability was strong for confirming/rejecting extrasystoles. CONCLUSIONS: Extrasystoles are available for fluid responsiveness prediction in septic patients in about half of the time. With this extrasystolic availability, we believe the method to be considered for clinical use, provided that future studies validate the method's fluid responsiveness prediction ability.

20.
PeerJ ; 6: e4912, 2018.
Artigo em Inglês | MEDLINE | ID: mdl-29892504

RESUMO

BACKGROUND: Constipation is suspected to occur frequently after acquired brain injury (ABI). In patients with ABI, heart rate variability (HRV) is reduced suggesting autonomic dysfunction. Autonomic dysfunction may be associated with prolonged gastrointestinal transit time (GITT). The primary aim of this study was to investigate if GITT is prolonged in patients with ABI. Secondarily, HRV and its correlation with GITT was investigated. METHODS: We included 25 patients with ABI (18 men, median age: 61.3 years, range [30.7-74.5]). GITT was assessed using radio-opaque markers and HRV was calculated from 24-hour electrocardiograms. Medical records were reviewed for important covariates, including primary diagnosis, time since injury, functional independence measure, and use of medication. The GITT assessed in patients was compared to a control group of 25 healthy subjects (18 men, median age: 61.5 years, range [34.0-70.9]). RESULTS: In ABI patients, the mean GITT was significantly longer than in healthy controls (2.68 days, 95% CI [2.16-3.19] versus (1.92 days, 95% CI [1.62-2.22], p = 0.011)). No correlation was found between HRV and GITT. CONCLUSION: Patients with mild to moderate ABI have prolonged GITT unrelated to the HRV.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...