1.
Opt Express ; 25(16): 19236-19250, 2017 Aug 07.
Artigo em Inglês | MEDLINE | ID: mdl-29041117

RESUMO

4D computed tomography (4D-CT) aims to visualise the temporal dynamics of a 3D sample with a sufficiently high temporal and spatial resolution. Successive time frames are typically obtained by sequential scanning, followed by independent reconstruction of each 3D dataset. Such an approach requires a large number of projections for each scan to obtain images with sufficient quality (in terms of artefacts and SNR). Hence, there is a clear trade-off between the rotation speed of the gantry (i.e. time resolution) and the quality of the reconstructed images. In this paper, the MotionVector-based Iterative Technique (MoVIT) is introduced which reconstructs a particular time frame by including the projections of neighbouring time frames as well. It is shown that such a strategy improves the trade-off between the rotation speed and the SNR. The framework is tested on both numerical simulations and on 4D X-ray CT datasets of polyurethane foam under compression. Results show that reconstructions obtained with MoVIT have a significantly higher SNR compared to the SNR of conventional 4D reconstructions.

2.
Microsc Microanal ; 17(2): 252-63, 2011 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-21281537

RESUMO

Three-dimensional (3D) analysis is an essential tool to obtain quantitative results from 3D datasets. Considerable progress has been made in 3D imaging techniques, resulting in a growing need for more flexible, complete analysis packages containing advanced algorithms. At the Centre for X-ray Tomography of the Ghent University (UGCT), research is being done on the improvement of both hardware and software for high-resolution X-ray computed tomography (CT). UGCT collaborates with research groups from different disciplines, each having specific needs. To meet these requirements the analysis software package, Morpho+, was developed in-house. Morpho+ contains an extensive set of high-performance 3D operations to obtain object segmentation, separation, and parameterization (orientation, maximum opening, equivalent diameter, sphericity, connectivity, etc.), or to extract a 3D geometrical representation (surface mesh or skeleton) for further modeling. These algorithms have a relatively short processing time when analyzing large datasets. Additionally, Morpho+ is equipped with an interactive and intuitive user interface in which the results are visualized. The package allows scientists from various fields to obtain the necessary quantitative results when applying high-resolution X-ray CT as a research tool to the nondestructive investigation of the microstructure of materials.

3.
IEEE Trans Image Process ; 19(9): 2419-27, 2010 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-20350850

RESUMO

In computed tomography, the application of iterative reconstruction methods in practical situations is impeded by their high computational demands. Especially in high resolution X-ray computed tomography, where reconstruction volumes contain a high number of volume elements (several giga voxels), this computational burden prevents their actual breakthrough. Besides the large amount of calculations, iterative algorithms require the entire volume to be kept in memory during reconstruction, which quickly becomes cumbersome for large data sets. To overcome this obstacle, we present a novel multiresolution reconstruction, which greatly reduces the required amount of memory without significantly affecting the reconstructed image quality. It is shown that, combined with an efficient implementation on a graphical processing unit, the multiresolution approach enables the application of iterative algorithms in the reconstruction of large volumes at an acceptable speed using only limited resources.


Assuntos
Algoritmos , Processamento de Imagem Assistida por Computador/métodos , Intensificação de Imagem Radiográfica/métodos , Tomografia Computadorizada por Raios X/métodos , Imagens de Fantasmas
4.
J Opt Soc Am A Opt Image Sci Vis ; 26(4): 890-4, 2009 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-19340263

RESUMO

When a very-low-absorbing sample is scanned at an x-ray computed tomography setup with a microfocus x-ray tube and a high-resolution detector, the obtained projection images contain not only absorption contrast but also phase contrast. While images without a phase signal can be reconstructed very well, such mixed phase and absorption images give rise to severe artifacts in the reconstructed slices. A method is described that applies a correction to these mixed projections to remove the phase signal. These corrected images can then be processed using a standard filtered backprojection algorithm to obtain reconstructions with only few or no phase artifacts. This new method, which we call the Bronnikov-aided correction (BAC), can be used in a broad variety of applications and without much additional effort. It is tested on a biological and a pharmaceutical sample, and results are evaluated and discussed by comparing them with those of conventional reconstruction methods.

5.
Physiol Biochem Zool ; 82(1): 51-62, 2009.
Artigo em Inglês | MEDLINE | ID: mdl-19072236

RESUMO

Loricariidae, or suckermouth armored catfishes, possess upper and lower jaws that are ventrally oriented and that bear teeth that touch the substrate from which algae and other food items are scraped. The ventral orientation and the highly specialized morphology of the jaws, characterized by protrusible upper jaws and left-right decoupled lower jaws, are observed in Pterygoplichthys disjunctivus, the species investigated here. Kinematic data of the scraping feeding movements, obtained by external high-speed and x-ray recordings, are used to quantify jaw movement, especially to test for upper jaw mobility and versatility during substrate scraping. Our results show that the mobility of the jaws is indeed high compared with what is standard for catfishes. The upper jaw's ability to perform a substantial degree of rostrocaudal movement is quite unique for catfishes. The ventromedially oriented lower jaws, with the teeth and the coronoid process at opposite sides, display an extensive mobility: they rotate around the suspensorial articulation and around their longitudinal axis, resulting in an extended scraping movement and thereby covering a large surface area. The lower jaws also show a left-right asymmetry in their movements during scraping. Thus, our results suggest that the extreme morphological specializations of the jaws in loricariid catfishes are linked to an increased mobility and functional versatility, allowing these animals to efficiently scrape algae from substrates with irregular surfaces.


Assuntos
Peixes-Gato/anatomia & histologia , Comportamento Alimentar/fisiologia , Arcada Osseodentária/anatomia & histologia , Animais , Fenômenos Biomecânicos , Peixes-Gato/fisiologia
6.
J Magn Reson ; 190(2): 189-99, 2008 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-18023218

RESUMO

Diffusion weighted magnetic resonance imaging enables the visualization of fibrous tissues such as brain white matter. The validation of this non-invasive technique requires phantoms with a well-known structure and diffusion behavior. This paper presents anisotropic diffusion phantoms consisting of parallel fibers. The diffusion properties of the fiber phantoms are measured using diffusion weighted magnetic resonance imaging and bulk NMR measurements. To enable quantitative evaluation of the measurements, the diffusion in the interstitial space between fibers is modeled using Monte Carlo simulations of random walkers. The time-dependent apparent diffusion coefficient and kurtosis, quantifying the deviation from a Gaussian diffusion profile, are simulated in 3D geometries of parallel fibers with varying packing geometries and packing densities. The simulated diffusion coefficients are compared to the theory of diffusion in porous media, showing a good agreement. Based on the correspondence between simulations and experimental measurements, the fiber phantoms are shown to be useful for the quantitative validation of diffusion imaging on clinical MRI-scanners.


Assuntos
Mapeamento Encefálico/métodos , Imagem de Difusão por Ressonância Magnética/métodos , Imagens de Fantasmas , Algoritmos , Anisotropia , Água Corporal/metabolismo , Simulação por Computador , Processamento de Imagem Assistida por Computador , Imageamento Tridimensional , Método de Monte Carlo , Fibras Nervosas