Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Eur J Nucl Med ; 28(10): 1496-504, 2001 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-11685492

RESUMO

Fluorine-18 fluorodeoxyglucose positron emission tomography (FDG-PET), technetium-99m hexamethylpropylene amine oxime (HMPAO)-labelled white blood cell (WBC) scintigraphy and bone scintigraphy were used in the evaluation of total knee arthroplasties (TKAs). We prospectively included 21 patients who had a three-phase bone scan for exclusion of infection of TKAs. Four hours after injection of 185 MBq 99mTc-HMPAO-labelled WBCs, planar and single-photon emission tomographic (SPET) imaging was performed. Planar imaging was repeated at 24 h p.i. Consecutively images of the knees were obtained with a dedicated PET system 60 min following the injection of 370 MBq of FDG. Focal tracer uptake was scored on SPET and PET visually (0=no uptake, 4=intense uptake). In addition, SUV (standardised uptake value) per voxel was calculated from attenuation-corrected PET images using the MLAA algorithm. Focal uptake at the bone-prosthesis interface was used as the criterion for infection before and after correlation with the third phase of the bone scan. Final diagnosis was based on operative findings, culture and clinical outcome. In the infected TKAs, the WBC scan showed focal activity of grade 2 (n=2), 3 (n=l) or 4 (n=2). PET scan revealed focal activity of grade 4 (n=5) or 3 (n=1). WBC scan alone had a specificity for infection of 53% [positive predictive value (PPV) 42%, sensitivity 100%], compared with 73% for PET scan (PPV 60%, sensitivity 100%). Considering only lesions at the bone-prosthesis interface that were also present on the third phase of the bone scan, we found a specificity of 93% (PPV 83%) for WBC scan. Using these criteria, a specificity of 80% (PPV 67%) was obtained for PET scan. Two out of three false-positive PET scans were due to loosening of the TKA. It is concluded that WBC scintigraphy in combination with bone scintigraphy has a high specificity in the detection of infected TKAs. FDG-PET seems to offer no additional benefit.


Assuntos
Osso e Ossos/diagnóstico por imagem , Fluordesoxiglucose F18 , Prótese do Joelho , Leucócitos/diagnóstico por imagem , Dor Pós-Operatória/diagnóstico por imagem , Compostos Radiofarmacêuticos , Tecnécio Tc 99m Exametazima , Tomografia Computadorizada de Emissão , Adulto , Idoso , Feminino , Humanos , Masculino , Pessoa de Meia-Idade
2.
J Nucl Med ; 36(1): 133-9, 1995 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-7799067

RESUMO

UNLABELLED: With the introduction of 99mTc-teboroxime, a previously undocumented artifact has shown up in cardiac SPECT imaging. In the images, the uptake values near the inferior wall are lower than expected. The artifact has been reported in the literature, but an adequate explanation has not yet been provided. The high uptake of 99mTc-teboroxime in the liver has been demonstrated to be the cause of this artifact. METHODS: With simulations we show that an artifact can be reproduced by applying filtered backprojection (without corrections for attenuation) of attenuated and blurred projections. The conclusions from the simulations are validated with SPECT and PET phantom measurements. Maximum likelihood expectation maximization (ML-EM) reconstruction is applied to evaluate the effect of accurate attenuation correction. The influence of the high liver uptake on the convergence of ML-EM was also evaluated. RESULTS: The artifact results mainly when the photon attenuation during reconstruction is ignored. This results in a distorted reconstruction of the liver. These distortions affect the neighboring inferior wall of the myocardium. While the use of opposite projections reduces the effect, accurate attenuation correction nearly eliminates it. A small additional deformation is caused by the position dependence of the spatial resolution of the gamma camera. It was also noted that the presence of the liver slows down the convergence of ML-EM in the heart region. CONCLUSION: The liver-heart artifact is an attenuation effect and is eliminated by attenuation correction. The local convergence of ML-EM is affected by the total image content.


Assuntos
Artefatos , Coração/diagnóstico por imagem , Fígado/diagnóstico por imagem , Compostos de Organotecnécio , Oximas , Tomografia Computadorizada de Emissão de Fóton Único , Animais , Humanos , Processamento de Imagem Assistida por Computador , Modelos Estruturais , Tomografia Computadorizada de Emissão
3.
Clin Imaging ; 16(4): 230-3, 1992.
Artigo em Inglês | MEDLINE | ID: mdl-1473028

RESUMO

The effects of age and laterality on sacroiliac (SI) to sacral indices and ratios were assessed in 62 patients. For the 14 controls, the left mean SI to sacral index was significantly higher than the right one. There was no correlation between age and SI to sacral ratio (= average of right and left index). The mean ratio in 36 patients with sacroiliitis and 12 patients with low back pain was not significantly different from that of the controls, with a clear overlap of indices between controls and sacroiliitis patients.


Assuntos
Articulação Sacroilíaca/diagnóstico por imagem , Espondilite Anquilosante/diagnóstico por imagem , Adulto , Análise de Variância , Feminino , Humanos , Masculino , Radiografia , Cintilografia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...