Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Appl Occup Environ Hyg ; 16(7): 729-35, 2001 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-11458919

RESUMO

The aim of the study was to assess the use of 3M porous polymer extraction discs (3M Empore sorbent filters) for detection of chemical permeation of protective clothing. Analysis of some commonly used solvents on 3M Empore sorbent filters was performed for methanol, acetone, trichloroethylene (TriCE), and toluene by solvent desorption and gas chromatography. All solvents exhibited >98 percent adsorption on the filters at a spiking level of 1.8 microL for each solvent. Solvent recovery for the system was calculated for each solvent, ranging from 72-94 percent (RSD < or = 4.0%) for all solvents over the spiking range 0.2-1.8 microL. The modified ASTM F739 method was used to determine breakthrough times for five protective glove materials (polyvinyl chloride, natural rubber, polymerized alkene, nitrile, and nitrile butyl rubber) using the model solvents as test chemicals. Breakthrough times for each type of protective glove were determined, and found to range from 36 s to 9 min for acetone, from 142 s to 52 min for methanol, from 18 s to 12 min for TriCE, and from 32 s to 28 min for toluene. The quantitative mass of the solvents on the filters at the time of breakthrough detection ranged from 150-159, 157-166, 570-581, and 371-382 microg/cm2 for acetone, methanol, TriCE, and toluene, respectively. The sorbent filter should find utility in collecting chemical permeation samples through protective gloves in both laboratory and field studies for quantitative analysis.


Assuntos
Teste de Materiais , Roupa de Proteção , Administração Cutânea , Humanos , Exposição Ocupacional/prevenção & controle , Permeabilidade , Polímeros/química , Solventes
2.
AIHAJ ; 61(6): 837-41, 2000.
Artigo em Inglês | MEDLINE | ID: mdl-11192217

RESUMO

A quantitative study of aromatic amine permeation through a glove material using Permea-Tec aromatic amine pads, used for the detection of chemical breakthrough of protective clothing, was performed for aniline following the microwave extraction process and gas chromatographic analysis. Aniline exhibited >99% adsorption on the pads at a spiking level of 1.94 mg (1.9 microL). Aniline showed recoveries from 65 to 89% (RSD < or =5.6%) over the range 1.1-1.9 microL (1.12-1.94 mg) of aniline applied to pads. The modified ASTM F739 and direct permeability testing procedures were used to determine breakthrough times for five protective glove materials using aniline as a challenge chemical. Breakthrough times for six protective gloves were determined, ranging from 182 sec to 82 min. The quantitative concentration of aniline on the pads following permeation through the gloves also was determined, ranging from 0.53 to 0.55 mg/cm2 (1.79-1.88 mg/pad).


Assuntos
Compostos de Anilina/análise , Luvas Protetoras/normas , Teste de Materiais/métodos , Exposição Ocupacional/análise , Permeabilidade , Adsorção , Calibragem , Cromatografia Gasosa , Desenho de Equipamento , Humanos , Estados Unidos
3.
J Environ Monit ; 1(6): 545-8, 1999 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-11529186

RESUMO

A quantitative study of alkylamine permeation through a glove material using Permea-Tec aliphatic amine pads, used for the detection of chemical breakthrough of protective clothing, was performed for triethylamine following a microwave-extraction process and gas chromatographic analysis. Triethylamine exhibited > 99% adsorption on the pads at a spiking level of 729 ng (1.0 ml). Triethylamine showed recoveries from 63 to 90% (RSD < or = 5%) over the range 0.2-1.0 ml (146-729 ng) applied to pads. The ASTM F739 standard and direct permeability testing procedures were used to determine breakthrough times for five protective glove materials using triethylamine as a challenge chemical. Breakthrough times for six protective gloves were determined ranging from 40 s to > 4 h. The quantitative concentration of triethylamine on the pads following permeation through the gloves was also determined, ranging from 101 to 103 ng cm-2 (382-386 ng per pad).


Assuntos
Aminas/química , Luvas Protetoras/normas , Cromatografia Gasosa , Falha de Equipamento , Humanos , Teste de Materiais , Micro-Ondas , Exposição Ocupacional , Permeabilidade
4.
Analyst ; 124(6): 941-4, 1999 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-10736878

RESUMO

The efficiency of solvent adsorption using Permea-Tec general solvent pads, used for the detection of chemical breakthrough of protective clothing, was determined for methanol, acetone, ethyl methyl ketone, trichloroethylene (TriCE), tetrachloroethylene (TetCE), toluene, m-xylene, and D-limonene. Known volumes of single or mixed solvents were added to pads in the range 0.2-5.0 microliters (0.16-8.13 micrograms). After microwave-solvent extraction (ME) into hexan-1-ol, the samples (0.5-3.0 microliters) of the filtered and extracted solutions were analyzed by gas chromatography. All solvents exhibited > 97% adsorption on the pads at spiking levels of 0.48-0.98 microgram for each solvent. The solvent recovery for the system was calculated for each solvent, with solvents with boiling points below 110 degrees C showing recoveries of > 90%, and with solvents with boiling points above 110 degrees C showing recoveries from 80 to 90%. The recovery precision was good (RSD < or = 4%) for all solvents over the range 1.0-2.5 microliters of applied solvents to pads for ME and 1.0 microliter of extracted solutions for GC analysis.


Assuntos
Poluentes Ocupacionais do Ar/análise , Roupa de Proteção , Solventes/análise , Cromatografia Gasosa , Humanos , Micro-Ondas
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...