Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Abdom Imaging ; 25(3): 317-21, 2000.
Artigo em Inglês | MEDLINE | ID: mdl-10823459

RESUMO

BACKGROUND: To evaluate the performance of delayed contrast enhanced computed tomography (DCT) in characterizing renal masses. METHODS: Twenty-four patients with suspected renal masses or indeterminate renal masses on previous imaging studies were prospectively evaluated with preintravenous contrast imaging, conventional contrast-enhanced computed tomography (imaging initiated 2 min after intravenous contrast injection), and DCT (imaging initiated 13 min after injection of intravenous contrast). Only lesions larger than 1.0 cm were evaluated, with scanning parameters kept constant across the three scans. RESULTS: All pathologically confirmed renal cell carcinomas (n = 6) were detected on DCT using a threshold attenuation decrease of 10 Hounsfield units (HU). A significant decrease (p = 0.031) in attenuation occurred in renal cell carcinomas (mean = 29.6 +/- 23.6 HU) compared with the attenuation change (mean decrease = 1.1 +/- 7.1 HU), which occurred in non-neoplastic renal cysts (n = 34). Non-neoplastic renal cysts were correctly classified by DCT 32 of 34 times (94%). CONCLUSIONS: In this study, DCT distinguished renal cell carcinomas from non-neoplastic cysts in a vast majority of cases and may aid in characterizing incidentally discovered renal lesions on postcontrast CT.


Assuntos
Adenoma/diagnóstico por imagem , Carcinoma de Células Renais/diagnóstico por imagem , Doenças Renais Císticas/diagnóstico por imagem , Neoplasias Renais/diagnóstico por imagem , Tomografia Computadorizada por Raios X , Adenoma/patologia , Adulto , Idoso , Idoso de 80 Anos ou mais , Carcinoma de Células Renais/patologia , Diagnóstico Diferencial , Feminino , Humanos , Doenças Renais Císticas/patologia , Neoplasias Renais/patologia , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos
2.
Clin Imaging ; 23(3): 172-6, 1999.
Artigo em Inglês | MEDLINE | ID: mdl-10506911

RESUMO

An appropriate Doppler response to valsalva in the common femoral veins has been described previously as excluding a more proximal venous obstruction. We describe our experience in three patients in whom an appropriate response to valsalva did not exclude a more proximal pelvic venous obstruction. Dampening of the Doppler waveforms on the affected side when compared with the opposite limb led to the diagnosis of proximal venous obstruction.


Assuntos
Veia Femoral/diagnóstico por imagem , Ultrassonografia Doppler , Adulto , Constrição Patológica/diagnóstico por imagem , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Pelve/irrigação sanguínea , Manobra de Valsalva , Doenças Vasculares/diagnóstico por imagem , Trombose Venosa/diagnóstico por imagem
3.
J Clin Ultrasound ; 27(8): 415-20, 1999 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-10477882

RESUMO

PURPOSE: We determined the accuracy of sonography in the detection of isolated calf deep venous thrombosis (DVT) and the rate of indeterminate ultrasound examinations in patients with physical signs or symptoms suggestive of DVT. METHODS: We reviewed the medical literature (MEDLINE) to determine the accuracy of sonography and the frequency of indeterminate studies in detecting isolated calf DVT in patients with physical signs or symptoms suggestive of DVT. A meta-analysis was used to derive summary measures of sensitivity, specificity, and accuracy from studies in which 5 or more isolated calf DVT were identified. Frequencies of indeterminate examinations were recorded for studies in which these data were provided, and we pooled these results with our own data for 196 patients. RESULTS: The meta-analysis revealed that sonography correctly identified isolated calf DVT in 49 of 53 extremities (sensitivity, 92.5%; 95% confidence interval, 81.8-97.9%) and correctly identified the absence of calf DVT in 157 of 159 extremities (specificity, 98.7%; 95% confidence interval, 95.5-99. 9%), yielding an accuracy of 97.2% (95% confidence interval, 93.9-99. 0%) for ultrasound examinations considered diagnostic. However, when evaluating our patient population and the literature, we found a substantial number of indeterminate studies (overall rate of 54.6% in 463 extremities), with a wide variation in the reported frequency of indeterminate studies (9.3-82.7%). CONCLUSIONS: Sonography is highly accurate in detecting isolated calf DVT in symptomatic patients, but indeterminate studies occur frequently, with a wide range of reported rates. Each ultrasound laboratory should evaluate its own rate of indeterminate studies.


Assuntos
Trombose Venosa/diagnóstico por imagem , Feminino , Humanos , Perna (Membro)/irrigação sanguínea , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Estudos Retrospectivos , Sensibilidade e Especificidade , Ultrassonografia
4.
J Clin Ultrasound ; 27(6): 325-33, 1999.
Artigo em Inglês | MEDLINE | ID: mdl-10395128

RESUMO

PURPOSE: The purpose of this study was to evaluate the utility of sonography in distinguishing between mechanical and nonmechanical causes for renal transplant dysfunction. METHODS: We reviewed all ultrasound examination reports (n = 286) for 63 consecutive patients who received 64 renal transplants. We assessed the sensitivity and specificity of different degrees of hydronephrosis (mild, moderate, or severe) in detecting urinary tract obstruction; different volumes of new or increasing peritransplant fluid in detecting urine leaks; different total volumes of peritransplant fluid in predicting significant compression of the transplant; and Doppler vascular criteria for predicting arterial and venous occlusion. RESULTS: All mechanical complications were detected (100% sensitivity) with specificities of 91.9% for ureteral obstruction (criterion, moderate hydronephrosis), 83.4% for urine leaks (criterion, any new fluid or any increase), 91.4% for fluid collections that compressed the transplant (criterion, > 100 ml), and 100% for vascular occlusion (criteria, no flow for arterial occlusion; no venous flow and reversal of arterial flow during diastole for venous occlusion). CONCLUSIONS: Sonography is very useful in distinguishing between mechanical and nonmechanical causes for renal transplant dysfunction. It has high sensitivity and acceptable specificity in this setting.


Assuntos
Rejeição de Enxerto/diagnóstico por imagem , Transplante de Rim/efeitos adversos , Ultrassonografia/normas , Obstrução Ureteral/diagnóstico por imagem , Adolescente , Adulto , Idoso , Feminino , Humanos , Hidronefrose/diagnóstico por imagem , Rim/irrigação sanguínea , Rim/diagnóstico por imagem , Rim/patologia , Transplante de Rim/diagnóstico por imagem , Masculino , Pessoa de Meia-Idade , Complicações Pós-Operatórias/diagnóstico por imagem , Fluxo Sanguíneo Regional , Sensibilidade e Especificidade , Ultrassonografia/métodos
5.
J Ultrasound Med ; 18(7): 481-7, 1999 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-10400051

RESUMO

Our objective was to investigate whether the angiotensin converting enzyme inhibitor enalaprilat improves detection of hemodynamically significant renal artery stenoses in dogs. Renal artery stenoses of 50 to 99% were surgically created unilaterally in five dogs. Doppler ultrasonographic evaluation was performed at baseline (no stenosis), after creation of the stenosis, and after the administration of enalaprilat. The resistive index increased in the nonstenotic kidney (P < 0.01) but not in the stenotic kidney after administration of enalaprilat. The difference in resistive indices between nonstenotic and stenotic kidneys increased significantly (P < 0.05) after administration of enalaprilat. Measurement of the resistive index after administration of an angiotensin converting enzyme inhibitor in humans may improve the performance of Doppler ultrasonography in detecting hemodynamically significant renal artery stenoses.


Assuntos
Inibidores da Enzima Conversora de Angiotensina , Enalaprilato , Obstrução da Artéria Renal/diagnóstico por imagem , Ultrassonografia Doppler/efeitos dos fármacos , Animais , Cães , Obstrução da Artéria Renal/fisiopatologia , Resistência Vascular/efeitos dos fármacos
6.
Clin Imaging ; 23(1): 35-9, 1999.
Artigo em Inglês | MEDLINE | ID: mdl-10332597

RESUMO

We evaluated the utility of sonography and nuclear medicine renography in the detection of urine leaks in 57 renal transplant patients. Sonography and renography were equally sensitive in detecting leaks. But renography was more specific and therefore accurate (p < 0.0001) in detecting leaks. Urine leaks should be considered on sonography, which is often the first imaging study ordered in evaluating renal transplants, with new or increasing peritransplant fluid collections. Leaks should be confirmed by renography before performing additional invasive radiologic or surgical procedures.


Assuntos
Hidronefrose/diagnóstico por imagem , Transplante de Rim/efeitos adversos , Renografia por Radioisótopo , Adolescente , Adulto , Idoso , Feminino , Seguimentos , Humanos , Hidronefrose/etiologia , Rim/diagnóstico por imagem , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Sensibilidade e Especificidade , Ultrassonografia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...