Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
J Clin Monit Comput ; 26(6): 483-6, 2012 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-22552876

RESUMO

To demonstrate the potential usefulness of radial arterial line monitoring in detection of brachial plexus injury in spinal surgery. Multiple neuromonitoring modalities including SEPs, MEPs and EMG were performed for a posterior thoracicolumbar surgery. Radial arterial line (A-line) was placed on the right wrist for arterial blood pressure monitoring. Reliable ulnar nerve SEPs, hand muscle MEPs and arterial blood pressure readings were obtained after patient was placed in a prone position. A-line malfunction was noted about 15 min after incision. Loss of ulnar nerve SEPs and hand muscle MEPs with a cold hand on the right was noticed when neuromonitoring resumed after spine exposure. SEPs, MEPs, A-line readings and hand temperature returned after modification of the right arm position. Radial arterial line monitoring may help detect positional brachial plexus injury in spinal surgery when continuous neuromonitoring is interrupted during spine exposure in prone position.


Assuntos
Plexo Braquial/lesões , Vértebras Lombares/cirurgia , Monitorização Intraoperatória , Posicionamento do Paciente/efeitos adversos , Artéria Radial , Vértebras Torácicas/cirurgia , Dispositivos de Acesso Vascular , Pressão Sanguínea , Eletromiografia , Potencial Evocado Motor , Potenciais Somatossensoriais Evocados , Feminino , Humanos , Pessoa de Meia-Idade
2.
Arch Sex Behav ; 34(4): 469-70, 2005 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-16010469

RESUMO

Strangulation of the penis by application of constricting devices may present a challenge for the treating physician. Depending on the type of constricting material, special equipment is essential for successful removal of the foreign bodies. We report a new form of constricting device, the neck of a Coca Cola bottle made of Pentaethylene-terephthalate (PET). Particular difficulties were encountered upon removal. Technical details of this case are described. Prior literature on the treatment of penile strangulation is discussed.


Assuntos
Corpos Estranhos/etiologia , Corpos Estranhos/cirurgia , Pênis , Polietilenotereftalatos/efeitos adversos , Idoso , Intoxicação Alcoólica/complicações , Constrição Patológica/etiologia , Constrição Patológica/cirurgia , Humanos , Masculino , Pênis/irrigação sanguínea , Pênis/lesões , Pênis/cirurgia , Comportamento Autodestrutivo/complicações
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...