Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Rheumatol Ther ; 8(1): 151-165, 2021 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-33245554

RESUMO

INTRODUCTION: Intra-articular (i.a.) hyaluronic acid is an accepted conservative therapy for knee osteoarthritis (OA). This study evaluated the safety and efficacy of a single i.a. injection of an innovative formulation of sodium hyaluronate 2.4% plus sodium chondroitin non-sulphated 1.6% of biotechnological origin (HA-SC) for the treatment of patients with radiographically confirmed symptomatic hip OA and moderate-to-severe pain. METHODS: In this prospective, multicenter, open-label, pilot study, HA-SC was administered using a standard ultrasound-guided procedure. Adverse events, global/local evaluation of tolerability, and use of rescue analgesics were recorded. Efficacy endpoints included visual analogue scale (VAS) measurement of hip pain, changes in Lequesne's algofunctional Index, and assessment of global status. RESULTS: Treatment was well tolerated; adverse device events of moderate-to-severe intensity, most commonly, injection site pain/localized arthralgia occurred in 20.8% of subjects. Global evaluation of tolerability was rated as excellent or good (75.0%), fair (16.7%), and poor (8.3%) by subjects and 77.1, 14.6, and 8.3%, respectively, by investigators. There was a rapid and significant decrease in hip pain after a single injection; VAS pain score decreased from a mean of 67.5 mm at baseline to 29.3 mm by day 7, with the effects sustained during 6 months of follow-up (P < 0.0001). There were significant improvements in Lequesne's Index for hip OA total scores at all time points during follow-up (P < 0.0001). The majority of subjects reported 'Very much improved' or 'Slightly improved' global improvement at any time point. Use of rescue paracetamol was generally low. CONCLUSIONS: A single i.a. injection of an innovative HA-SC formulation was well tolerated, safe, and effective in the treatment of symptomatic hip OA.

2.
Skeletal Radiol ; 38(2): 149-56, 2009 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-18846372

RESUMO

PURPOSE: The purpose of this study was to determine the diagnostic performance of magnetic resonance (MR) obtained with intra-articular contrast medium in the evaluation of recurrent meniscal tears using low-field extremity-only and high-field whole-body magnets. MATERIALS AND METHODS: Postoperative standard MR examinations and MR arthrographies of 95 knees were reviewed. Patients experiencing pain and disability after meniscal repair underwent standard MR and MR arthrography (Gadoterate meglumine 0.0025 mmol/ml) on both a 0.2-T and 1.5-T magnet. In 52 of 95 patients, second-look arthroscopy was performed; in the remaining 43 of 95 patients, clinical follow-up was used as the standard of reference. Sensitivity, specificity, positive and negative predictive values as well as accuracy of MRI/MR arthrographic signs as meniscal morphologic changes and the presence of contrast medium tracking into the tear at T1- and T2-weighted sequences in the detection of recurrent meniscal tears were determined. RESULTS: All MR and MR arthrograpic signs were sensitive in the detection of recurrent tears (range 80-91%). Abnormal meniscal morphology had low specificity [26% (13/50)] for both the 0.2-T and 1.5-T scanner, whereas accuracy was 55% (52/95) and 57% (54/95), respectively. The presence of contrast medium within the meniscus substance on T2-weighted images had higher value of specificity [84% (42/50)] and accuracy [84% (80/95)] by using low field strength magnet than by using high field strength magnet [74% (37/50) and 81% (77/95), respectively]. Whereas, the increased intrameniscal signal intensity extending to the meniscal surface at T1-weighted sequences after intra-articular contrast medium administration had lower specificity and accuracy on 0.2-T images [84% (42/50) and 82% (78/95), respectively] than on 1.5-T images [90% (45/50) and 88% (84/95), respectively]. CONCLUSION: A diagnosis of recurrent meniscal tear in a previously arthroscopically repaired meniscus can be made both on 0.2-T and 1.5-T magnets on the basis of increased signal on T2-weighted and T1-weighted images in the presence of intra-articular contrast material.


Assuntos
Traumatismos do Joelho/diagnóstico , Imageamento por Ressonância Magnética/métodos , Lesões do Menisco Tibial , Adulto , Distribuição de Qui-Quadrado , Meios de Contraste/administração & dosagem , Feminino , Humanos , Injeções Intra-Articulares , Traumatismos do Joelho/cirurgia , Imageamento por Ressonância Magnética/instrumentação , Masculino , Meglumina/administração & dosagem , Meniscos Tibiais/cirurgia , Pessoa de Meia-Idade , Compostos Organometálicos/administração & dosagem , Valor Preditivo dos Testes , Recidiva , Sensibilidade e Especificidade
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...