Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 9 de 9
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Water Res ; 229: 119384, 2023 Feb 01.
Artigo em Inglês | MEDLINE | ID: mdl-36442271

RESUMO

In this study non-invasive low field magnetic resonance imaging (MRI) technology was used to monitor fouling induced changes in fiber-by-fiber hydrodynamics inside a multi-fiber hollow fiber membrane module containing 401 fibers. Using structural and velocity images the fouling evolution of these membrane modules were shown to exhibit distinct trends in fiber-by-fiber volumetric flow, with increasing fouling causing a decrease in the number of flow active fibers. This study shows that the fouling rate is not evenly distributed over the parallel fibers, which results in a broadening of the fiber to fiber flowrate distribution. During cleaning, this distribution is initially broadened further, as relatively clean fibers are cleaned more rapidly compared to clogged fibers. By tracking the volumetric flow rate of individual fibers inside the modules during the fouling-cleaning cycle it was possible to observe a fouling memory-like effect with residual fouling occurring preferentially at the outer edge of the fiber bundle during repeated fouling-cleaning cycle. These results demonstrate the ability of MRI velocity imaging to quantitatively monitor these effects which are important when testing the effectiveness of cleaning protocols due to the long term effect that residual fouling and memory-like effect may have on the operation of membrane modules.


Assuntos
Membranas Artificiais , Purificação da Água , Reatores Biológicos , Imageamento por Ressonância Magnética , Hidrodinâmica , Purificação da Água/métodos , Ultrafiltração
2.
Water Res ; 196: 117006, 2021 May 15.
Artigo em Inglês | MEDLINE | ID: mdl-33744656

RESUMO

A novel magnetic resonance measurement (MRM) protocol for non-invasive monitoring of fouling in spiral wound reverse osmosis (SWRO) membrane modules is demonstrated. Sodium alginate was used to progressively foul a commercial SWRO membrane at industrially relevant operating conditions in a circulating flow loop. The MRM protocol showcased the following: (i) earlier, more sensitive detection and quantification of fouling in the membrane module compared to feed-channel pressure drop. This was achieved using appropriate detection of the total nuclear magnetic resonance (NMR) signal. (ii) 2D cross-sectional imaging of the location of the accumulated foulant material; this was preferentially located adjacent to the membrane spacer sheet nodes, which was subsequently confirmed by a module autopsy. This image contrast, which could also readily differentiate the membrane, feed spacer and permeate spacer regions, was realised based on differences in the NMR relaxation parameter, T2,eff. (iii) High frequency acquisition of 2D cross-sectional velocity images of the module revealing very localised flow channelling in response to gradual foulant accumulation which impacted significantly on the flow pattern within the central permeate tube. Collectively this NMR/MRI measurement protocol provides a powerful analysis tool for the evolution of fouling in such complex modules, thus ultimately enabling more informed module design.


Assuntos
Incrustação Biológica , Purificação da Água , Filtração , Espectroscopia de Ressonância Magnética , Membranas Artificiais , Osmose
3.
J Magn Reson ; 250: 7-16, 2015 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-25459882

RESUMO

Nuclear magnetic resonance (NMR) relaxometry is commonly used to provide lithology-independent porosity and pore-size estimates for petroleum resource evaluation based on fluid-phase signals. However in shales, substantial hydrogen content is associated with solid and fluid signals and both may be detected. Depending on the motional regime, the signal from the solids may be best described using either exponential or Gaussian decay functions. When the inverse Laplace transform, the standard method for analysis of NMR relaxometry results, is applied to data containing Gaussian decays, this can lead to physically unrealistic responses such as signal or porosity overcall and relaxation times that are too short to be determined using the applied instrument settings. We apply a new simultaneous Gaussian-Exponential (SGE) inversion method to simulated data and measured results obtained on a variety of oil shale samples. The SGE inversion produces more physically realistic results than the inverse Laplace transform and displays more consistent relaxation behavior at high magnetic field strengths. Residuals for the SGE inversion are consistently lower than for the inverse Laplace method and signal overcall at short T2 times is mitigated. Beyond geological samples, the method can also be applied in other fields where the sample relaxation consists of both Gaussian and exponential decays, for example in material, medical and food sciences.


Assuntos
Espectroscopia de Ressonância Magnética/métodos , Algoritmos , Simulação por Computador , Hidrogênio/química , Distribuição Normal , Petróleo/análise , Porosidade
4.
Environ Sci Technol ; 47(2): 987-92, 2013 Jan 15.
Artigo em Inglês | MEDLINE | ID: mdl-23256613

RESUMO

The extent to which T(2) relaxation measurements can be used to determine biofouling in several natural geological sand media using a low-field (275 kHz, 6.5 mT) NMR system has been demonstrated. It has been previously shown that, at high laboratory strength fields (300 MHz, 7 T), T(2) techniques can be used as a bioassay to confirm the growth of biofilm inside opaque porous media with low magnetic susceptibilities such as borosilicate or soda lime glass beads. Additionally decreases in T(2) can be associated with intact biofilm as opposed to degraded biofilm material. However, in natural geological media, the strong susceptibility gradients generated at high fields dominated the T(2) relaxation time distributions and biofilm growth could not be reliably detected. Samples studied included Bacillus mojavensis biofilm in several sand types, as well as alginate solution and alginate gel in several sand types. One of the sand types was highly magnetic. Data was collected with a low-field (275 kHz, 6.5 mT) benchtop NMR system using a CPMG sequence with an echo time of 1.25 ms providing the ability to detect signals with T(2) greater than 1 ms. Data presented here clearly demonstrate that biofilm can be reliably detected and monitored in highly magnetically susceptible geological samples using a low-field NMR spectrometer indicating that low-field NMR could be viable as a biofilm sensor at bioremedation sites.


Assuntos
Bacillus/fisiologia , Biofilmes , Incrustação Biológica , Espectroscopia de Ressonância Magnética/métodos , Alginatos/química , Biofilmes/crescimento & desenvolvimento , Reatores Biológicos/microbiologia , Desenho de Equipamento , Ácido Glucurônico/química , Ácidos Hexurônicos/química , Porosidade , Dióxido de Silício/química
5.
Biotechnol Bioeng ; 110(5): 1366-75, 2013 May.
Artigo em Inglês | MEDLINE | ID: mdl-23239390

RESUMO

Biofilm growth in porous media is difficult to study non-invasively due to the opaqueness and heterogeneity of the systems. Magnetic resonance is utilized to non-invasively study water dynamics within porous media. Displacement-relaxation correlation experiments were performed on fluid flow during biofilm growth in a model porous media of mono-dispersed polystyrene beads. The spin-spin T2 magnetic relaxation distinguishes between the biofilm phase and bulk fluid phase due to water-biopolymer interactions present in the biofilm, and the flow dynamics are measured using PGSE NMR experiments. By correlating these two measurements, the effects of biofilm growth on the fluid dynamics can be separated into a detailed analysis of both the biofilm phase and the fluid phase simultaneously within the same experiment. Within the displacement resolution of these experiments, no convective flow was measured through the biomass. An increased amount of longitudinal hydrodynamic dispersion indicates increased hydrodynamic mixing due to fluid channeling caused by biofilm growth. The effect of different biofilm growth conditions was measured by varying the strength of the bacterial growth medium.


Assuntos
Biofilmes/crescimento & desenvolvimento , Modelos Teóricos , Ressonância Magnética Nuclear Biomolecular/métodos , Biomassa , Meios de Cultura , Permeabilidade , Porosidade
6.
J Magn Reson ; 225: 17-24, 2012 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-23099629

RESUMO

Polycrystalline ice, as found in glaciers and the ice sheets of Antarctica, is a low porosity porous media consisting of a complicated and dynamic pore structure of liquid-filled intercrystalline veins within a solid ice matrix. In this work, Nuclear Magnetic Resonance measurements of relaxation rates and molecular diffusion, useful for probing pore structure and transport dynamics in porous systems, were used to physically characterize the unfrozen vein network structure in ice and its response to the presence of metabolic products produced by V3519-10, a cold tolerant microorganism isolated from the Vostok ice core. Recent research has found microorganisms that can remain viable and even metabolically active within icy environments at sub-zero temperatures. One potential mechanism of survival for V3519-10 is secretion of an extracellular ice binding protein that binds to the prism face of ice crystals and inhibits ice recrystallization, a coarsening process resulting in crystal growth with ice aging. Understanding the impact of ice binding activity on the bulk vein network structure in ice is important to modeling of frozen geophysical systems and in development of ice interacting proteins for biotechnology applications, such as cryopreservation of cell lines, and manufacturing processes in food sciences. Here, we present the first observations of recrystallization inhibition in low porosity ice containing V3519-10 extracellular protein extract as measured with Nuclear Magnetic Resonance and Magnetic Resonance Imaging.


Assuntos
Bactérias/metabolismo , Gelo , Espectroscopia de Ressonância Magnética/métodos , Água/química , Bactérias/química , Proteínas de Bactérias/química , Proteínas de Bactérias/metabolismo , Cristalização , Congelamento , Peso Molecular , Ligação Proteica
7.
Phys Rev E Stat Nonlin Soft Matter Phys ; 85(4 Pt 2): 045301, 2012 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-22680531

RESUMO

We interpret a generalized short-time expansion of stochastic hydrodynamic dispersion dynamics in the case of small Reynolds number flow through macroscopically homogenous permeable porous media to directly determine hydrodynamic permeability. The approach allows determination of hydrodynamic permeability from pulsed field gradient spin-echo nuclear magnetic resonance measurement of the short-time effective hydrodynamic dispersion coefficient. The analytical expansion of asymptotic dynamics agrees with experimental NMR data and lattice Boltzmann simulation of hydrodynamic dispersion in consolidated random sphere pack media.


Assuntos
Biofísica/métodos , Hidrodinâmica , Espectroscopia de Ressonância Magnética/métodos , Permeabilidade , Difusão , Eletroquímica/métodos , Modelos Lineares , Modelos Estatísticos , Porosidade , Processos Estocásticos , Fatores de Tempo , Viscosidade
8.
J Biotechnol ; 161(3): 320-7, 2012 Oct 31.
Artigo em Inglês | MEDLINE | ID: mdl-22728394

RESUMO

Advanced magnetic resonance (MR) relaxation and diffusion correlation measurements and imaging provide a means to non-invasively monitor gelation for biotechnology applications. In this study, MR is used to characterize physical gelation of three alginates with distinct chemical structures; an algal alginate, which is not O-acetylated but contains poly guluronate (G) blocks, bacterial alginate from Pseudomonas aeruginosa, which does not have poly-G blocks, but is O-acetylated at the C2 and/or C3 of the mannuronate residues, and alginate from a P. aeruginosa mutant that lacks O-acetyl groups. The MR data indicate that diffusion-reaction front gelation with Ca(2+) ions generates gels of different bulk homogeneities dependent on the alginate structure. Shorter spin-spin T(2) magnetic relaxation times in the alginate gels that lack O-acetyl groups indicate stronger molecular interaction between the water and biopolymer. The data characterize gel differences over a hierarchy of scales from molecular to system size.


Assuntos
Alginatos/química , Géis/química , Espectroscopia de Ressonância Magnética/métodos , Pseudomonas aeruginosa/química , Biopolímeros/química , Difusão
9.
Biotechnol Bioeng ; 109(4): 877-83, 2012 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-22095467

RESUMO

The conversion of soluble uranyl ions (UO2²âº) by bacterial reduction to sparingly soluble uraninite (UO2(s)) is being studied as a way of immobilizing subsurface uranium contamination. Under anaerobic conditions, several known types of bacteria including iron and sulfate reducing bacteria have been shown to reduce U (VI) to U (IV). Experiments using a suspension of uraninite (UO2(s)) particles produced by Shewanella putrefaciens CN32 bacteria show a dependence of both longitudinal (T1) and transverse (T2) magnetic resonance (MR) relaxation times on the oxidation state and solubility of the uranium. Gradient echo and spin echo MR images were compared to quantify the effect caused by the magnetic field fluctuations (T*2) of the uraninite particles and soluble uranyl ions. Since the precipitate studied was suspended in liquid water, the effects of concentration and particle aggregation were explored. A suspension of uraninite particles was injected into a polysaccharide gel, which simulates the precipitation environment of uraninite in the extracellular biofilm matrix. A reduction in the T2 of the gel surrounding the particles was observed. Tests done in situ using three bioreactors under different mixing conditions, continuously stirred, intermittently stirred, and not stirred, showed a quantifiable T2 magnetic relaxation effect over the extent of the reaction.


Assuntos
Biodegradação Ambiental , Espectroscopia de Ressonância Magnética/métodos , Shewanella putrefaciens/metabolismo , Poluentes Radioativos do Solo/metabolismo , Compostos de Urânio/análise , Urânio/metabolismo , Anaerobiose , Biofilmes , Reatores Biológicos , Cátions , Precipitação Química , Coloides , Hidrogéis , Nanopartículas Metálicas , Concentração Osmolar , Oxirredução , Solubilidade , Suspensões
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...