Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 437
Filtrar
1.
Rev Sci Instrum ; 95(6)2024 Jun 01.
Artigo em Inglês | MEDLINE | ID: mdl-38832850

RESUMO

In this work, a concept for a neutron diffractometer for high-resolution macromolecular structures has been developed within the Jülich High Brilliance Neutron Source (HBS) project. The SELENE optics are adapted to the requirements of the instrument to achieve a tunable low background neutron beam at mm2 scale sample area. With the optimized guide geometry, a low background neutron beam can be achieved at the small sample area with tunable divergence and size. For the 1 × 1 mm2 sample, a flux of 1.10 × 107 n/s/cm2 for 0.38° divergence is calculated in the 2-4 Å wavelength range, which is about 84.6% of the flux at MaNDi of the high-power spallation source SNS at ORNL. Virtual neutron scattering experiments have been performed to demonstrate the instrument's capabilities for studies of mm scale samples with large unit cells. Results of Vitesse simulations indicate that unit cell sizes of up to 200 Å are possible to be resolved with the proposed instrument.

2.
Eur Phys J C Part Fields ; 84(1): 18, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38205101

RESUMO

High-precision searches for an electric dipole moment of the neutron (nEDM) require stable and uniform magnetic field environments. We present the recent achievements of degaussing and equilibrating the magnetically shielded room (MSR) for the n2EDM experiment at the Paul Scherrer Institute. We present the final degaussing configuration that will be used for n2EDM after numerous studies. The optimized procedure results in a residual magnetic field that has been reduced by a factor of two. The ultra-low field is achieved with the full magnetic-field-coil system, and a large vacuum vessel installed, both in the MSR. In the inner volume of ∼1.4m3, the field is now more uniform and below 300 pT. In addition, the procedure is faster and dissipates less heat into the magnetic environment, which in turn, reduces its thermal relaxation time from 12h down to 1.5h.

3.
Rev Sci Instrum ; 95(1)2024 Jan 01.
Artigo em Inglês | MEDLINE | ID: mdl-38180345

RESUMO

Various theories beyond the Standard Model predict new particles with masses in the sub-eV range with very weak couplings to ordinary matter. A new P-odd and T-odd interaction between polarized and unpolarized nucleons proportional to s⃗⋅r̂ is one such possibility, where r⃗=rr̂ is the spatial vector connecting the nucleons, and s⃗ is the spin of the polarized nucleon. Such an interaction involving a scalar coupling gsN at one vertex and a pseudoscalar coupling gpn at the polarized nucleon vertex can be induced by the exchange of spin-0 pseudoscalar bosons. We describe a new technique to search for interactions of this form and present the first measurements of this type. We show that future improvements to this technique can improve the laboratory upper bound on the product gsNgpn by two orders of magnitude for interaction ranges at the 100 micron scale.

4.
Acta Crystallogr B Struct Sci Cryst Eng Mater ; 79(Pt 5): 354-367, 2023 Oct 01.
Artigo em Inglês | MEDLINE | ID: mdl-37578185

RESUMO

Spin-crossover (SCO) compounds are promising materials for a wide variety of industrial applications. However, the fundamental understanding of their nature of transition and its effect on the physical properties are still being fervently explored; the microscopic knowledge of their transition is essential for tailoring their properties. Here an attempt is made to correlate the changes in macroscopic physical properties with microscopic structural changes in the orthorhombic and monoclinic polymorphs of the SCO compound Fe(PM-Bia)2(NCS)2 (PM = N-2'-pyridylmethylene and Bia = 4-aminobiphenyl) by employing single-crystal X-ray diffraction, magnetization and DSC measurements. The dependence of macroscopic properties on cooperativity, highlighting the role of hydrogen bonding, π-π and van der Waals interactions is discussed. Values of entropy, enthalpy and cooperativity are calculated numerically based on the Slichter-Drickamer model. The particle size dependence of the magnetic properties is probed along with the thermal exchange and the kinetic behavior of the two polymorphs based on the dependence of magnetization on temperature scan rate and a theoretical model is proposed for the calculation of the non-equilibrium spin-phase fraction. Also a scan-rate-dependent two-step behavior observed for the orthorhombic polymorph, which is absent for the monoclinic polymorph, is reported. Moreover, it is found that the radiation dose from synchrotron radiation affects the spin-crossover process and shifts the transition region to lower temperatures, implying that the spin crossover can be tuned with radiation damage.

5.
Int J Cardiol ; 331: 144-151, 2021 05 15.
Artigo em Inglês | MEDLINE | ID: mdl-33535079

RESUMO

Conflicting data exist about the relationship between cardiac resynchronization therapy (CRT) and diastolic function. Aims of the study are to assess diastolic patterns in patients undergoing CRT according to the 2016 recommendations of the American Society of Echocardiography/European Association of Cardiovascular Imaging and to evaluate the prognostic value of diastolic dysfunction (DD) in CRT candidates. METHODS AND RESULTS: One-hundred ninety-three patients (age: 67 ± 11 years, QRS width: 167 ± 21 ms) were included in this multicentre prospective study. Mitral filling pattern, mitral tissue Doppler velocity, tricuspid regurgitation velocity, and indexed left atrial volume were used to classify DD from grade I to III. CRT-response, defined as a reduction of left ventricular (LV) end-systolic volume > 15% at 6-month follow-up (FU), occurred in 132 (68%) patients. The primary endpoint was a composite of heart transplantation, LV assisted device implantation, or all-cause death during FU and occurred in 29 (15%) patients. CRT was associated with a degradation of DD in non-responders. At multivariable analysis corrected for clinical variables, QRS duration, mitral regurgitation, CRT-response and LV dyssynchrony, grade I DD was associated with a better outcome (HR 0.37, 95% CI: 0.14-0.96). Non-responders with grade II-III DD had the worse prognosis (HR 4.36, 95%CI: 2.10-9.06). CONCLUSIONS: The evaluation of DD in CRT candidates allows the prognostic stratification of patients, independently from CRT-response.


Assuntos
Terapia de Ressincronização Cardíaca , Insuficiência Cardíaca , Idoso , Insuficiência Cardíaca/terapia , Humanos , Pessoa de Meia-Idade , Prognóstico , Estudos Prospectivos , Resultado do Tratamento
6.
Herzschrittmacherther Elektrophysiol ; 31(2): 151-159, 2020 Jun.
Artigo em Alemão | MEDLINE | ID: mdl-32385572

RESUMO

INTRODUCTION: In patients with pacemaker (PM) therapy, His bundle stimulation (HBS) may lead to a more synchronous activation of the left ventricle (LV) than conventional right ventricular stimulation (RVS). In this study, we investigated to which extent this effect can be objectified by means of contemporary echocardiographic functional imaging. METHODS: In all, 15 RVS patients (6 women, mean age 76.6 ± 4.1 years) and 15 HBS patients (6 women, mean age 74.6 ± 3.7 years) underwent echocardiography with and without cardiac pacing. Besides LV end-diastolic volume (EDV), ejection fraction (EF), and global strain (GLS), we measured global and regional myocardial work and LV efficiency based on noninvasive pressure-strain loops. RESULTS: In all HBS patients, optimization of PM settings resulted in immediate changes in myocardial function parameters. With pacing, RVS patients showed a higher decrease in EF and GLS than HBS patients. Global LV work and LV work efficiency decreased significantly only in RVS patients. CONCLUSION: Changes in regional and global myocardial function can by proven and quantified by functional echocardiography. In patients under PM therapy, HBS shows functional advantages in comparison to conventional RVS.


Assuntos
Ventrículos do Coração , Idoso , Idoso de 80 Anos ou mais , Fascículo Atrioventricular , Ecocardiografia , Feminino , Humanos , Masculino , Volume Sistólico , Disfunção Ventricular Esquerda , Função Ventricular Esquerda
7.
J Phys Condens Matter ; 32(16): 165801, 2020 Apr 17.
Artigo em Inglês | MEDLINE | ID: mdl-31899900

RESUMO

The ability to create atomically perfect, epitaxial heterostructures of correlated complex perovskite oxides using state-of-art thin film deposition techniques has generated new physical phenomena at engineered interfaces. Here we report on the impact of growth kinetics on the magnetic structure and exchange coupling at the interface in heterostructures combining layers of antiferromagnetic La1/3Sr2/3FeO3 (LSFO) and ferromagnetic La2/3Sr1/3MnO3 (LSMO) on (0 0 1)-oriented SrTiO3 (STO) substrates. Two growth orders are investigated, (a) LSMO/LSFO/STO(0 0 1) and (b) LSFO/LSMO/STO(0 0 1), where the LSFO layer is grown by molecular beam epitaxy and the LSMO layer by high oxygen pressure sputtering. The interface has been investigated using electron microscopy and polarized neutron reflectometry. Interdiffusion over seven monolayers is observed in LSMO/LSFO (a) with an almost 50% reduction in magnetization at the interface and showing no exchange coupling. However, the exchange bias effect ([Formula: see text] mT at 10 K) could be realized when the interface is atomically sharp, as in LSFO/LSMO (b). Our study therefore reveals that, even for well ordered and lattice-matched structures, the kinetics involved in the growth processes drastically influences the interface quality with a strong correlation to the magnetic properties.

8.
J Nucl Cardiol ; 27(1): 62-70, 2020 02.
Artigo em Inglês | MEDLINE | ID: mdl-28233192

RESUMO

BACKGROUND: The partial volume correction (PVC) of cardiac PET datasets using anatomical side information during reconstruction is appealing but not straightforward. Other techniques, which do not make use of additional anatomical information, could be equally effective in improving the reconstructed myocardial activity. METHODS: Resolution modeling in combination with different noise suppressing priors was evaluated as a means to perform PVC. Anatomical priors based on a high-resolution CT are compared to non-anatomical, edge-preserving priors (relative difference and total variation prior). The study is conducted on ex vivo datasets from ovine hearts. A simulation study additionally clarifies the relationship between prior effectiveness and myocardial wall thickness. RESULTS: Simple resolution modeling during data reconstruction resulted in over- and underestimation of activity, which hampers the absolute left ventricular quantification when compared to the ground truth. Both the edge-preserving and the anatomy-based PVC techniques improve the absolute quantification, with comparable results (Student t-test, P = .17). The relative tracer distribution was preserved with any reconstruction technique (repeated ANOVA, P = .98). CONCLUSIONS: The use of edge-preserving priors emerged as optimal choice for quantification of tracer uptake in the left ventricular wall of the available datasets. Anatomical priors visually outperformed edge-preserving priors when the thinnest structures were of interest.


Assuntos
Técnicas de Imagem Cardíaca , Coração/diagnóstico por imagem , Processamento de Imagem Assistida por Computador , Tomografia por Emissão de Pósitrons , Algoritmos , Animais , Simulação por Computador , Humanos , Modelos Animais , Ovinos
9.
Phys Rev Lett ; 123(14): 143003, 2019 Oct 04.
Artigo em Inglês | MEDLINE | ID: mdl-31702217

RESUMO

We report results of a new technique to measure the electric dipole moment of ^{129}Xe with ^{3}He comagnetometry. Both species are polarized using spin-exchange optical pumping, transferred to a measurement cell, and transported into a magnetically shielded room, where SQUID magnetometers detect free precession in applied electric and magnetic fields. The result from a one week measurement campaign in 2017 and a 2.5 week campaign in 2018, combined with detailed study of systematic effects, is d_{A}(^{129}Xe)=(1.4±6.6_{stat}±2.0_{syst})×10^{-28} e cm. This corresponds to an upper limit of |d_{A}(^{129}Xe)|<1.4×10^{-27} e cm (95% C.L.), a factor of 5 more sensitive than the limit set in 2001.

10.
Behav Brain Res ; 363: 191-198, 2019 05 02.
Artigo em Inglês | MEDLINE | ID: mdl-30735761

RESUMO

The prefrontal cortex (PFC) undergoes protracted postnatal development such that its structure and behavioural function may be profoundly altered by environmental factors. Here we investigate the effect of lactational dietary manipulations on novel object recognition (NOR) learning and PFC monoamine neurotransmitter metabolism in early adolescent rats. To this end, Wistar rat dams were fed a high caloric cafeteria diet (CD) during lactation and resultant 24-26 day old offspring exposed to NOR testing and simultaneous PFC dopamine and serotonin metabolism measurement. In the second NOR choice trial where one familiar and one novel object were presented controls explored the novel preferentially to the familiar object both after a 5 min (P < 0.001) or 30 min (P < 0.05) inter-trial intervals (ITI). By contrast, offspring from dams fed on lactational CD failed to show any significant preference for the novel object at either time point. Compared with chow fed controls, their average exploration ratio of the novel object was lower after the 5 min ITI (P < 0.05). Following a 60 min ITI, neither CD nor control offspring showed a preference for the novel object. PFC dopamine metabolism was significantly reduced in the CD group (P < 0.001), whereas serotonin metabolism was increased (P < 0.001). These results suggest that an obesogenic lactational diet can have a detrimental impact on cognition in adolescent offspring associated with aberrant PFC serotonin and dopamine metabolism.


Assuntos
Dieta Hiperlipídica/efeitos adversos , Comportamento Exploratório/efeitos dos fármacos , Fenômenos Fisiológicos da Nutrição Materna/fisiologia , Fatores Etários , Animais , Monoaminas Biogênicas/metabolismo , Cognição/efeitos dos fármacos , Cognição/fisiologia , Dieta , Dopamina/metabolismo , Comportamento Exploratório/fisiologia , Feminino , Lactação , Aprendizagem , Masculino , Córtex Pré-Frontal/efeitos dos fármacos , Córtex Pré-Frontal/metabolismo , Córtex Pré-Frontal/fisiologia , Gravidez , Efeitos Tardios da Exposição Pré-Natal/fisiopatologia , Ratos , Ratos Wistar
11.
J Nucl Cardiol ; 26(6): 2034-2044, 2019 12.
Artigo em Inglês | MEDLINE | ID: mdl-30644052

RESUMO

BACKGROUND: In a previous study on ex vivo, static cardiac datasets, we investigated the benefits of performing partial volume correction (PVC) in cardiac 18F-Fluorodeoxyglucose(FDG) PET datasets. In the present study, we extend the analysis to in vivo cardiac datasets, with the aim of defining which reconstruction technique maximizes quantitative accuracy and, ultimately, makes PET a better diagnostic tool for cardiac pathologies. METHODS: In vivo sheep datasets were acquired and reconstructed with/without motion correction and using several reconstruction algorithms (with/without resolution modeling, with/without non-anatomical priors). Corresponding ex vivo scans of the excised sheep hearts were performed on a small-animal PET scanner (Siemens Focus 220, microPET) to provide high-resolution reference data unaffected by respiratory and cardiac motion. A comparison between the in vivo cardiac reconstructions and the corresponding ex vivo ground truth was performed. RESULTS: The use of an edge-preserving prior (Total Variation (TV) prior in this work) in combination with motion correction reduces the bias in absolute quantification when compared to the standard clinical reconstructions (- 0.83 vs - 3.74 SUV units), when the end-systolic gate is considered. At end-diastole, motion correction improves absolute quantification but the PVC with priors does not improve the similarity to the ground truth more than a regular iterative reconstruction with motion correction and without priors. Relative quantification was not influenced much by the chosen reconstruction algorithm. CONCLUSIONS: The relative ranking of the algorithms suggests superiority of the PVC reconstructions with dual gating in terms of overall absolute quantification and noise properties. A well-tuned edge-preserving prior, such as TV, enhances the noise properties of the resulting images of the heart. The end-systolic gate yields the most accurate quantification of cardiac datasets.


Assuntos
Coração/diagnóstico por imagem , Movimento (Física) , Tomografia por Emissão de Pósitrons , Algoritmos , Animais , Feminino , Fluordesoxiglucose F18 , Ventrículos do Coração/diagnóstico por imagem , Processamento de Imagem Assistida por Computador/métodos , Imageamento Tridimensional/métodos , Ovinos , Software , Sístole
12.
Opt Express ; 26(13): 17350-17359, 2018 Jun 25.
Artigo em Inglês | MEDLINE | ID: mdl-30119547

RESUMO

We report on an optically pumped magnetometer that uses multiple laser beams to pump and probe spin-polarized Cs atoms. The selected sensor geometry allows for operation in finite magnetic fields as well as close to zero field. In finite fields the magnetometer employs free spin precession signals to determine the field modulus and direction as described in a separate publication. This publication focuses on the magnetometer operation close to zero field, which is based on a ground state Hanle resonance. The four laser beams permit the simultaneous measurement of two orthogonal magnetic field components in a differential detection scheme that greatly suppresses technical laser power noise. Sensitivities better than 54 fT/Hz1/2 could be demonstrated simultaneously for both measurement channels in a well shielded environment. A minimum Allan deviation, limited by residual field fluctuations, of better than 40 fT was observed for integration times of 2s. The magnetometer achieves high sensitivity and stability in offset fields as well as close to zero field and is, thus, a universal tool for low frequency magnetic field measurements.

13.
J Phys Condens Matter ; 28(47): 476001, 2016 11 30.
Artigo em Inglês | MEDLINE | ID: mdl-27633731

RESUMO

We report a comprehensive specific heat and inelastic neutron scattering study to explore the possible origin of multiferroicity in HoCrO3. We have performed specific heat measurements in the temperature range 100 mK-290 K and inelastic neutron scattering measurements were performed in the temperature range 1.5-200 K. From the specific heat data we determined hyperfine splitting at 22.5(2) µeV and crystal field transitions at 1.379(5) meV, 10.37(4) meV, 15.49(9) meV and 23.44(9) meV, indicating the existence of strong hyperfine and crystal field interactions in HoCrO3. Further, an effective hyperfine field is determined to be 600(3) T. The quasielastic scattering observed in the inelastic scattering data and a large linear term [Formula: see text] mJ mol(-1) K(-2) in the specific heat is attributed to the presence of short range exchange interactions, which is understood to be contributing to the observed ferroelectricity. Further the nuclear and magnetic entropies were computed to be, ∼17.2 Jmol(-1) K(-1) and ∼34 Jmol(-1) K(-1), respectively. The entropy values are in excellent agreement with the limiting theoretical values. An anomaly is observed in the peak position of the temperature dependent crystal field spectra around 60 K, at the same temperature an anomaly in the pyroelectric current is reported. From this we could elucidate a direct correlation between the crystal electric field excitations of Ho(3+) and ferroelectricity in HoCrO3. Our present study, along with recent reports, confirm that HoCrO3, and RCrO3 (R = rare earth) in general, possess more than one driving force for the ferroelectricity and multiferroicity.

14.
Rofo ; 188(5): 488-93, 2016 May.
Artigo em Inglês | MEDLINE | ID: mdl-26981913

RESUMO

PURPOSE: Comparison of radiation dose of cone beam computed tomography (CBCT) and multidetector computed tomography (MDCT) in examinations of the hand. MATERIALS AND METHODS: Dose calculations were carried out by means of Monte Carlo simulations in MDCT and CBCT. A corpse hand was examined in a 320-row MDCT scanner and a dedicated extremities CBCT scanner with standard protocols and multiple low-dose protocols. The image quality of the examinations was evaluated by 5 investigators using a Likert scale from 1 (very good) to 5 (very poor) regarding depiction of cortical bone, cancellous bone, joint surfaces, soft tissues and artifacts. For a sum of ratings of all structures < 50 a good overall image quality was expected. The studies with at least good overall image quality were compared with respect to the dose. RESULTS: The dose of the standard examination was 13.21 (12.96 to 13.46 CI) mGy in MDCT and 7.15 (6.99 to 7.30 CI) mGy in CBCT. The lowest dose in a study with good overall image quality was 4.54 (4.43 to 4.64 CI) mGy in MDCT and 5.72 (5.59 to 5.85 CI) mGy in CBCT. CONCLUSION: Although the dose of the standard protocols in the CBCT is lower than in the MDCT, the MDCT can realize a good overall image quality at a lower dose than the CBCT. Dose optimization of CT examination protocols for the hand is useful in both modalities, the MDCT has an even greater potential for optimization. KEY POINTS: • Low dose examinations of the hand are feasible in CBCT and MDCT.• In default settings CBCT has a lower dose than MDCT.• MDCT enables a good image quality at a lower dose than CBCT. Citation Format: • Neubauer J, Neubauer C, Gerstmair A et al. Comparison of the Radiation Dose from Cone Beam Computed Tomography and Multidetector Computed Tomography in Examinations of the Hand. Fortschr Röntgenstr 2016; 188: 488 - 493.


Assuntos
Tomografia Computadorizada de Feixe Cônico , Mãos/diagnóstico por imagem , Tomografia Computadorizada Multidetectores , Doses de Radiação , Humanos , Imagens de Fantasmas
15.
J Nutr Sci ; 4: e3, 2015.
Artigo em Inglês | MEDLINE | ID: mdl-26090100

RESUMO

Fetal exposure to maternal undernutrition has lifelong consequences for physiological and metabolic function. Maternal low-protein diet is associated with an age-related phenotype in rats, characterised by a period of resistance to development of obesity in early adulthood, giving way to an obesity-prone, insulin-resistant state in later adulthood. Offspring of rats fed a control (18 % casein) or low-protein (9 % casein; LP) diet in pregnancy were challenged with a high-fat diet at 9 months of age. To assess whether other maternal factors modulated the programming effects of nutrition, offspring were studied from young (2-4 months old) and older (6-9 months old) mothers. Weight gain with a high-fat diet was attenuated in male offspring of older mothers fed LP (interaction of maternal age and diet; P = 0·011) and adipose tissue deposition was lower with LP feeding in both males and females (P < 0·05). Although the resistance to weight gain and adiposity was partially explained by lower energy intake in offspring of LP mothers (P < 0·001 males only), it was apparent that energy expenditure must be influenced by maternal diet and age. Assessment of locomotor activity indicated that energy expenditure associated with physical activity was unlikely to explain resistance to weight gain, but showed that offspring of older mothers were more anxious than those of younger mothers, with more rearing observed in a novel environment and on the elevated plus-maze. The data showed that in addition to maternal undernutrition, greater maternal age may influence development and long-term body composition in the rat.

16.
Rev Sci Instrum ; 86(5): 055109, 2015 May.
Artigo em Inglês | MEDLINE | ID: mdl-26026560

RESUMO

Several experiments in fundamental physics demand an environment of very low, homogeneous, and stable magnetic fields. For the magnetic characterization of such environments, we present a portable SQUID system that measures the absolute magnetic flux density vector and the gradient tensor. This vector-tensor system contains 13 integrated low-critical temperature (LTc) superconducting quantum interference devices (SQUIDs) inside a small cylindrical liquid helium Dewar with a height of 31 cm and 37 cm in diameter. The achievable resolution depends on the flux density of the field under investigation and its temporal drift. Inside a seven-layer mu-metal shield, an accuracy better than ±23 pT for the components of the static magnetic field vector and ±2 pT/cm for each of the nine components of the gradient tensor is reached by using the shifting method.


Assuntos
Ambiente Controlado , Campos Magnéticos , Desenho de Equipamento , Hélio , Impressão Tridimensional , Temperatura
17.
Lupus ; 24(4-5): 516-29, 2015 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-25801895

RESUMO

Antinuclear autoantibodies (ANA) are highly informative biomarkers in autoimmune diagnostics. The increasing demand for effective test systems, however, has led to the development of a confusingly large variety of different platforms. One of them, the indirect immunofluorescence (IIF), is regarded as the common gold standard for ANA screening, as described in a position statement by the American College of Rheumatology in 2009. Technological solutions have been developed aimed at standardization and automation of IIF to overcome methodological limitations and subjective bias in IIF interpretation. In this review, we present the EUROPattern Suite, a system for computer-aided immunofluorescence microscopy (CAIFM) including automated acquisition of digital images and evaluation of IIF results. The system was originally designed for ANA diagnostics on human epithelial cells, but its applications have been extended with the latest system update version 1.5 to the analysis of antineutrophil cytoplasmic antibodies (ANCA) and anti-dsDNA antibodies.


Assuntos
Anticorpos Antinucleares/análise , Sistemas Computacionais , Técnica Indireta de Fluorescência para Anticorpo/métodos , Interpretação de Imagem Assistida por Computador/instrumentação , Microscopia de Fluorescência/métodos , Automação , Biomarcadores , Humanos , Armazenamento e Recuperação da Informação , Padrões de Referência , Reprodutibilidade dos Testes , Software
18.
Psychopharmacology (Berl) ; 232(14): 2619-29, 2015 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-25743759

RESUMO

RATIONALE: Dopamine D1-like receptor signalling is involved in contextual fear conditioning, but the brain regions involved and its role in other contextual fear memory processes remain unclear. OBJECTIVES: The objective of this study was to investigate (1) the effects of SCH 23390, a dopamine D1/D5 receptor antagonist, on contextual fear memory encoding, retrieval and reconsolidation, and (2) if the effects of SCH 23390 on conditioning involve the dorsal hippocampus (DH) and/or basolateral amygdala (BLA). METHODS: Rats were used to examine the effects of systemically administering SCH 23390 on the acquisition, consolidation, retrieval and reconsolidation of contextual fear memory, and on locomotor activity and shock sensitivity. We also determined the effects of MK-801, an NMDA receptor antagonist, on contextual fear memory reconsolidation. The effects of infusing SCH 23390 locally into DH or BLA on contextual fear conditioning and locomotor activity were also examined. RESULTS: Systemic administration of SCH 23390 impaired contextual fear conditioning but had no effects on fear memory consolidation, retrieval or reconsolidation. MK-801 was found to impair reconsolidation, suggesting that the behavioural parameters used allowed for the pharmacological disruption of memory reconsolidation. The effects of SCH 23390 on conditioning were unlikely the result of any lasting drug effects on locomotor activity at memory test or any acute drug effects on shock sensitivity during conditioning. SCH 23390 infused into either DH or BLA impaired contextual fear conditioning and decreased locomotor activity. CONCLUSIONS: These findings suggest that dopamine D1-like receptor signalling in DH and BLA contributes to the acquisition of contextual fear memory.


Assuntos
Tonsila do Cerebelo/efeitos dos fármacos , Condicionamento Operante/efeitos dos fármacos , Medo/efeitos dos fármacos , Hipocampo/efeitos dos fármacos , Receptores de Dopamina D1/antagonistas & inibidores , Transdução de Sinais/efeitos dos fármacos , Animais , Benzazepinas/farmacologia , Maleato de Dizocilpina/farmacologia , Antagonistas de Dopamina/farmacologia , Eletrochoque , Masculino , Memória/efeitos dos fármacos , Atividade Motora/efeitos dos fármacos , Ratos
19.
Rev Sci Instrum ; 85(7): 075106, 2014 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-25085172

RESUMO

A versatile and portable magnetically shielded room with a field of (700 ± 200) pT within a central volume of 1 m × 1 m × 1 m and a field gradient less than 300 pT/m, achieved without any external field stabilization or compensation, is described. This performance represents more than a hundredfold improvement of the state of the art for a two-layer magnetic shield and provides an environment suitable for a next generation of precision experiments in fundamental physics at low energies; in particular, searches for electric dipole moments of fundamental systems and tests of Lorentz-invariance based on spin-precession experiments. Studies of the residual fields and their sources enable improved design of future ultra-low gradient environments and experimental apparatus. This has implications for developments of magnetometry beyond the femto-Tesla scale in, for example, biomagnetism, geosciences, and security applications and in general low-field nuclear magnetic resonance (NMR) measurements.

20.
J Pharmacol Toxicol Methods ; 68(2): 240-249, 2013.
Artigo em Inglês | MEDLINE | ID: mdl-23313807

RESUMO

INTRODUCTION: The free exploratory paradigm is regarded as a reliable test for trait anxiety in mice but it may also be useful in rats. Previously, we showed that rat strains differ in their free exploration of novel areas, i.e. the surroundings of their familiar home cage when the lid was removed. AIM: Therefore, the purpose of the present study was to further examine strain, sex, and age differences in animals from different breeders in combination with pharmacological treatment designed to modify anxiety. METHODS: In the present study free exploratory behaviour test was evaluated in Sprague Dawley and Wistar rats from different breeders. We assessed seasonal variation, habituation to the test, and the impact of gender and age on exploration. Furthermore, we monitored exploration following intraperitoneal diazepam, 8-OH-DPAT and caffeine administration. Parameters measured were latency to start exploring the outside of the cage, the percentage of rats that explored the outside, as well as the number of visits. RESULTS: There was no seasonal variability in free exploratory behaviour. However, strains and sexes differed in the test results, though age-related differences had less impact. Diazepam (2mg/kg) and 8-OH-DPAT (30, 100 and 300µg/kg) decreased neophobia while caffeine (50mg/kg) increased the latency to explore the outside the next day. DISCUSSION: The free exploratory behaviour test can be used as a simple and complementary test to study trait anxiety-related behaviour in rats.


Assuntos
Ansiedade/psicologia , Comportamento Animal/efeitos dos fármacos , Comportamento de Escolha/fisiologia , Comportamento Exploratório/fisiologia , 8-Hidroxi-2-(di-n-propilamino)tetralina/administração & dosagem , 8-Hidroxi-2-(di-n-propilamino)tetralina/farmacologia , Fatores Etários , Animais , Ansiedade/tratamento farmacológico , Cafeína/farmacologia , Comportamento de Escolha/efeitos dos fármacos , Diazepam/farmacologia , Modelos Animais de Doenças , Relação Dose-Resposta a Droga , Comportamento Exploratório/efeitos dos fármacos , Feminino , Humanos , Masculino , Ratos , Ratos Sprague-Dawley , Ratos Wistar , Estações do Ano , Fatores Sexuais , Especificidade da Espécie
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...