Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Anaesthesia ; 65(1): 36-43, 2010 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-19891671

RESUMO

We compared the classic laryngeal mask airway and i-gel as adjuncts to fibrescope guided intubation in a manikin. Two methods of intubation were compared with each device: the tracheal tube directly over the fibrescope; and the tracheal tube over an Aintree Intubation Catheter. Thirty-two anaesthetists took part in this randomised crossover study. Each anaesthetist performed two intubations with each method via each device. The mean (SD) time for the first intubation using the tracheal tube over the fibrescope was 43 (24) s with the classic laryngeal mask airway and 22 (9) s with the i-gel (95% CI for the difference 12-30 s, p < 0.0001). The mean (SD) times for the first intubation when using the Aintree Intubation Catheter was 46 (24) s with the classic laryngeal mask airway and 37 (9) s with the i-gel (95% CI for the difference 5-12 s, p < 0.0001). We recorded five (5/64, 8%) oesophageal intubations when using the classic laryngeal mask airway and none when using the i-gel. The participants rated the ease of railroading of the tracheal tube and railroading the Aintree Intubation Catheter over the fibrescope to be significantly easier (p < 0.0001 and p = 0.002 respectively) when using the i-gel than when using the classic laryngeal mask airway. Furthermore, 30/32 (94%) of anaesthetists reported preference for the i-gel over the classic laryngeal mask airway for fibrescope guided tracheal intubation when managing a difficult airway. We conclude that the i-gel is likely to be a more appropriate conduit than the classic laryngeal mask airway for fibrescope guided intubation irrespective of the intubation method used.


Assuntos
Tecnologia de Fibra Óptica/instrumentação , Intubação Intratraqueal/instrumentação , Competência Clínica , Estudos Cross-Over , Tecnologia de Fibra Óptica/métodos , Humanos , Intubação Intratraqueal/métodos , Máscaras Laríngeas , Manequins , Fatores de Tempo
2.
Emerg Med J ; 21(4): 457-60, 2004 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-15208230

RESUMO

OBJECTIVES: Although mnemonics are commonly used in medical education there are few data on their effectiveness. A RCT was undertaken to test the hypothesis that a new aide memoire, "EMD-aide", would be superior to the conventional "4Hs+4Ts" mnemonic in facilitating recall of causes of electromechanical dissociation (EMD) among house officers. METHOD: "EMD-aide", organises causes of EMD by frequency of occurrence and ease of reversibility: four groups organised by shape, colour, position, numbering, clockwise sequence, and use of arrows. Eight hospitals were randomised in a controlled trial and 149 house officers were then recruited by telephone. Baseline ability to recall causes of EMD was recorded at one minute and overall. House officers were then sent a copy of either "4Hs+4Ts" or "EMD-aide" according to randomisation group. Recall ability was retested at one month. RESULTS: 68 of 80 and 51 of 69 house officers completed the study in the "4Hs+4Ts" and "EMD-aide" groups respectively (NS) with similar baseline recall. After intervention median number of recalled causes was greater in the "EMD-aide" group, eight compared with seven at one minute (p = 0.034) and eight compared with seven overall, p = 0.067. Recall of all eight causes was more common in "EMD-aide" group, 54% compared with 35%, p = 0.054, and these house officers spent longer examining their aide memoire, p<0.001. CONCLUSIONS: "EMD-aide" may be superior to "4Hs+4Ts" in facilitating the recall of the causes of electromechanical dissociation. Educational psychology of medical learning and the use of aide memoires in general are worthy of further study.


Assuntos
Educação de Pós-Graduação em Medicina/métodos , Medicina de Emergência/educação , Parada Cardíaca/etiologia , Rememoração Mental , Psicologia Educacional , Abreviaturas como Assunto , Sistema de Condução Cardíaco , Humanos , Hipovolemia/complicações , Hipóxia/complicações , Corpo Clínico Hospitalar , Retenção Psicológica , Fatores de Risco
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...