Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Radiol Cardiothorac Imaging ; 6(2): e230182, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38602469

RESUMO

Fetal cardiac MRI using Doppler US gating is an emerging technique to support prenatal diagnosis of congenital heart disease and other cardiovascular abnormalities. Analogous to postnatal electrocardiographically gated cardiac MRI, this technique enables directly gated MRI of the fetal heart throughout the cardiac cycle, allowing for immediate data reconstruction and review of image quality. This review outlines the technical principles and challenges of cardiac MRI with Doppler US gating, such as loss of gating signal due to fetal movement. A practical workflow of patient preparation for the use of Doppler US-gated fetal cardiac MRI in clinical routine is provided. Currently applied MRI sequences (ie, cine or four-dimensional flow imaging), with special consideration of technical adaptations to the fetal heart, are summarized. The authors provide a literature review on the clinical benefits of Doppler US-gated fetal cardiac MRI for gaining additional diagnostic information on cardiovascular malformations and fetal hemodynamics. Finally, future perspectives of Doppler US-gated fetal cardiac MRI and further technical developments to reduce acquisition times and eliminate sources of artifacts are discussed. Keywords: MR Fetal, Ultrasound Doppler, Cardiac, Heart, Congenital, Obstetrics, Fetus Supplemental material is available for this article. © RSNA, 2024.


Assuntos
Imageamento por Ressonância Magnética , Cuidado Pré-Natal , Feminino , Gravidez , Humanos , Radiografia , Coração Fetal/diagnóstico por imagem , Tecnologia
2.
Front Cardiovasc Med ; 11: 1323443, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38410246

RESUMO

Purpose: This study aims to evaluate deep learning (DL) denoising reconstructions for image quality improvement of Doppler ultrasound (DUS)-gated fetal cardiac MRI in congenital heart disease (CHD). Methods: Twenty-five fetuses with CHD (mean gestational age: 35 ± 1 weeks) underwent fetal cardiac MRI at 3T. Cine imaging was acquired using a balanced steady-state free precession (bSSFP) sequence with Doppler ultrasound gating. Images were reconstructed using both compressed sensing (bSSFP CS) and a pre-trained convolutional neural network trained for DL denoising (bSSFP DL). Images were compared qualitatively based on a 5-point Likert scale (from 1 = non-diagnostic to 5 = excellent) and quantitatively by calculating the apparent signal-to-noise ratio (aSNR) and contrast-to-noise ratio (aCNR). Diagnostic confidence was assessed for the atria, ventricles, foramen ovale, valves, great vessels, aortic arch, and pulmonary veins. Results: Fetal cardiac cine MRI was successful in 23 fetuses (92%), with two studies excluded due to extensive fetal motion. The image quality of bSSFP DL cine reconstructions was rated superior to standard bSSFP CS cine images in terms of contrast [3 (interquartile range: 2-4) vs. 5 (4-5), P < 0.001] and endocardial edge definition [3 (2-4) vs. 4 (4-5), P < 0.001], while the extent of artifacts was found to be comparable [4 (3-4.75) vs. 4 (3-4), P = 0.40]. bSSFP DL images had higher aSNR and aCNR compared with the bSSFP CS images (aSNR: 13.4 ± 6.9 vs. 8.3 ± 3.6, P < 0.001; aCNR: 26.6 ± 15.8 vs. 14.4 ± 6.8, P < 0.001). Diagnostic confidence of the bSSFP DL images was superior for the evaluation of cardiovascular structures (e.g., atria and ventricles: P = 0.003). Conclusion: DL image denoising provides superior quality for DUS-gated fetal cardiac cine imaging of CHD compared to standard CS image reconstruction.

4.
Radiol Cardiothorac Imaging ; 5(1): e220129, 2023 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-36860838

RESUMO

Purpose: To apply Doppler US (DUS)-gated fetal cardiac cine MRI in clinical routine and investigate diagnostic performance in complex congenital heart disease (CHD) compared with that of fetal echocardiography. Materials and Methods: In this prospective study (May 2021 to March 2022), women with fetuses with CHD underwent fetal echocardiography and DUS-gated fetal cardiac MRI on the same day. For MRI, balanced steady-state free precession cine images were acquired in the axial and optional sagittal and/or coronal orientations. Overall image quality was assessed on a four-point Likert scale (from 1 = nondiagnostic to 4 = good image quality). The presence of abnormalities in 20 fetal cardiovascular features was independently assessed by using both modalities. The reference standard was postnatal examination results. Differences in sensitivities and specificities were determined by using a random-effects model. Results: The study included 23 participants (mean age, 32 years ± 5 [SD]; mean gestational age, 36 weeks ± 1). Fetal cardiac MRI was completed in all participants. The median overall image quality of DUS-gated cine images was 3 (IQR, 2.5-4). In 21 of 23 participants (91%), underlying CHD was correctly assessed by using fetal cardiac MRI. In one case, the correct diagnosis was made by using MRI only (situs inversus and congenitally corrected transposition of the great arteries). Sensitivities (91.8% [95% CI: 85.7, 95.1] vs 93.6% [95% CI: 88.8, 96.2]; P = .53) and specificities (99.9% [95% CI: 99.2, 100] vs 99.9% [95% CI: 99.5, 100]; P > .99) for the detection of abnormal cardiovascular features were comparable between MRI and echocardiography, respectively. Conclusion: Using DUS-gated fetal cine cardiac MRI resulted in performance comparable with that of using fetal echocardiography for diagnosing complex fetal CHD.Keywords: Pediatrics, MR-Fetal (Fetal MRI), Cardiac, Heart, Congenital, Fetal Imaging, Cardiac MRI, Prenatal, Congenital Heart DiseaseClinical trial registration no. NCT05066399 Supplemental material is available for this article. © RSNA, 2023See also the commentary by Biko and Fogel in this issue.

5.
Radiologie (Heidelb) ; 62(11): 933-940, 2022 Nov.
Artigo em Alemão | MEDLINE | ID: mdl-35976404

RESUMO

BACKGROUND: Cardiac magnetic resonance imaging (MRI) is an important diagnostic tool for initial diagnostic workup and follow-up of patients with congenital heart disease (CHD) of different age groups. OBJECTIVES: This review provides an overview of clinically applied MRI sequences for the assessment of CHD, highlights technical developments, and demonstrates key aspects of reporting in specific heart defects. MATERIALS AND METHODS: Presentation of epidemiologic data, summary of studies on MRI sequences and their clinical application, and demonstration of clinical examples. RESULTS: The broad spectrum of congenital heart defects requires the use of various sequences, which can be modified depending on patient age or treatment status. Cine imaging can be used to assess cardiac function and volumes, phase contrast flow measurements allow for the assessment of vessel hemodynamics, and various techniques of MR angiography allow visualization of the thoracic vessels with high spatiotemporal resolution. New developments allow high-resolution vascular imaging without the need for contrast agents, assessment of additional hemodynamic parameters, or fetal cardiac MRI. CONCLUSION: Cardiac MRI can be employed in children as well as in adults with CHD. By using different sequences and considering the treatment status and surgery-related complications, the vast majority of clinical questions can be answered.


Assuntos
Cardiopatias Congênitas , Criança , Adulto , Humanos , Cardiopatias Congênitas/diagnóstico por imagem , Imageamento por Ressonância Magnética , Feto , Meios de Contraste , Hemodinâmica
6.
J Cardiovasc Magn Reson ; 21(1): 54, 2019 08 29.
Artigo em Inglês | MEDLINE | ID: mdl-31462282

RESUMO

BACKGROUND: Myocardial T1 and T2 mapping are reliable diagnostic markers for the detection and follow up of acute myocarditis. The aim of this study was to compare the diagnostic performance of current mapping measurement approaches to differentiate between myocarditis patients and healthy individuals. METHODS: Fifty patients with clinically defined acute myocarditis and 30 healthy controls underwent cardiovascular magnetic resonance (CMR). Myocardial T1 relaxation times, T2 relaxation times, left ventricular (LV) function, T2 ratio, early gadolinium enhancement ratio, and presence of late gadolinium enhancement (LGE) were analysed. Native T1 and T2 relaxation times, as well as extracellular volume fraction (ECV) were measured for the entire LV myocardium (global), within the midventricular short axis slice (mSAX), within the midventricular septal wall (ConSept), and within the remote myocardium (remote). Receiver operating characteristics analysis was performed to compare diagnostic performance. RESULTS: All measurement approaches revealed significantly higher native T1 and T2 relaxation times as well as ECV values in patients compared to healthy controls (p < 0.05 for all parameters). The global measurement approach showed highest diagnostic performance regarding all mapping parameters (AUCs, native T1: 0.903, T2: 0.847, ECV: 0.731). Direct comparison of the different measurement approaches revealed significant differences in diagnostic performance between the global and the remote approach regarding T1 relaxation times and ECV (p = 0.001 and p = 0.002 respectively). Further, the global measurement approach revealed significantly higher T1 relaxation times compared to the ConSept approach (AUCs: 0.903 vs. 0.783; p = 0.003) and nearly significant differences compared to the mSAX approach (AUC: 0.850; p = 0.051). T2 relaxation times showed no significant differences between all measurement approaches (p > 0.050 for all parameters). CONCLUSIONS: Native T1 and T2 mapping allow for accurate detection of acute myocarditis irrespective of the measurement approach used. Even measurements performed exclusively within remote myocardium allow for reliable detection of acute myocarditis, demonstrating diffuse involvement of disease despite a mostly regional or patchy distribution pattern of visible pathologies. The global measurement approach provides the overall best diagnostic performance in acute myocarditis for both T1 and T2 mapping.


Assuntos
Imagem Cinética por Ressonância Magnética , Miocardite/diagnóstico por imagem , Miocárdio/patologia , Doença Aguda , Adulto , Estudos de Casos e Controles , Meios de Contraste/administração & dosagem , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Miocardite/patologia , Compostos Organometálicos/administração & dosagem , Valor Preditivo dos Testes , Estudos Prospectivos , Reprodutibilidade dos Testes , Adulto Jovem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...