1.
Clin Biochem ; 48(13-14): 881-5, 2015 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-26079315

RESUMO

OBJECTIVES: Our three academic institutions, Indiana University, Northwestern Memorial Hospital, and Wake Forest, were among the first in the United States to implement the Beckman Coulter AU5822 series chemistry analyzers. We undertook this post-hoc multi-center study by merging our data to determine performance characteristics and the impact of methodology changes on analyte measurement. DESIGN AND METHODS: We independently completed performance validation studies including precision, linearity/analytical measurement range, method comparison, and reference range verification. Complete data sets were available from at least one institution for 66 analytes with the following groups: 51 from all three institutions, and 15 from 1 or 2 institutions for a total sample size of 12,064. RESULTS: Precision was similar among institutions. Coefficients of variation (CV) were <10% for 97%. Analytes with CVs >10% included direct bilirubin and digoxin. All analytes exhibited linearity over the analytical measurement range. Method comparison data showed slopes between 0.900-1.100 for 87.9% of the analytes. Slopes for amylase, tobramycin and urine amylase were <0.8; the slope for lipase was >1.5, due to known methodology or standardization differences. Consequently, reference ranges of amylase, urine amylase and lipase required only minor or no modification. CONCLUSION: The four AU5822 analyzers independently evaluated at three sites showed consistent precision, linearity, and correlation results. Since installations, the test results had been well received by clinicians from all three institutions.


Assuntos
Química Clínica/instrumentação , Química Clínica/métodos , Bioensaio , Humanos , Valores de Referência , Estatística como Assunto
2.
J Chromatogr B Biomed Appl ; 685(2): 370-4, 1996 Oct 25.
Artigo em Inglês | MEDLINE | ID: mdl-8953182

RESUMO

A high-performance liquid chromatography procedure for detection and quantitation of ethylene glycol in serum is described. Ethylene glycol and internal standard are derivatized with benzoyl chloride under alkaline conditions, purified by solid-phase extraction and analyzed by HPLC with UV detection. Analytical recovery of ethylene glycol ranges between 96 and 103%. The calibration curve is linear from 20 to 2000 mg/l. The limits of detection and quantitation are 10 and 20 mg/l, respectively. Assay imprecision is 4.8% or less. The assay is free from common interferences and provides increased sensitivity, improved precision and extended linearity.


Assuntos
Cromatografia Líquida de Alta Pressão/métodos , Etilenoglicóis/sangue , Animais , Benzoatos/química , Calibragem , Bovinos , Etilenoglicóis/química , Modelos Lineares , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Espectrofotometria Ultravioleta