Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
BMJ Open ; 13(8): e072655, 2023 08 18.
Artigo em Inglês | MEDLINE | ID: mdl-37597862

RESUMO

OBJECTIVES: To investigate the underprescription of oral anticoagulation (OAC) in individual atrial fibrillation (AF) patients in primary care. SETTING: Screening of patient records in 39 participating general practitioners (GPs) across the Netherlands. PARTICIPANTS: We screened 101 207 patient records identifying 2375 non-valvular AF patients. METHODS: Using electronic patient files, we were able to screen the entire GP population for AF, CHA2DS2-VASc stroke risk scores, and the use of guidelines recommended OAC prescription. In case of a deviation from guidelines recommended OAC prescription, we checked the electronic patient file for any documented reason. Additionally, 6 weeks following the screening, we asked all GPs to provide information on any actions taken for the underprescribed patients. RESULTS: We found a mean CHA2DS2-VASc score of 3.2. OAC prescription consisted of direct OAC in 1342/1984 (68%) and vitamin K-antagonists in the remainder of patients. OAC underprescription was present in 93/944 (9.9%) females and 101/1374 (9.7%) in males, respectively. In 111/146 (76.0%) of the underprescribed AF patients, no reason to withhold OAC was reported. Reported reasons to withhold OAC were patient refusal (n=10), cardiologist advice (n=7) and high risk of bleeding (n=7). Data regarding actions following the identification of OAC underprescription were available for 92/194 (47%) of the OAC underprescribed cases. After consultation OAC was initiated in 9/92 (10%) only. CONCLUSIONS: In this large Dutch study among GPs, we observed 9.8% underprescription of OAC in AF patients. In 76% of the AF patients lacking a prescription for OAC, no documentation for deviating from the guidelines was found. Only in a minority of cases detection of OAC underprescription lead to OAC initiation.


Assuntos
Fibrilação Atrial , Medicina Geral , Feminino , Masculino , Humanos , Fibrilação Atrial/complicações , Fibrilação Atrial/tratamento farmacológico , Estudos Transversais , Países Baixos , Anticoagulantes/uso terapêutico
2.
Eur J Cardiovasc Nurs ; 22(4): 412-424, 2023 05 25.
Artigo em Inglês | MEDLINE | ID: mdl-35932189

RESUMO

AIMS: The aim of this TeleCheck-AF sub-analysis was to evaluate motivation and adherence to on-demand heart rate/rhythm monitoring app in patients with atrial fibrillation (AF). METHODS AND RESULTS: Patients were instructed to perform 60 s app-based heart rate/rhythm recordings 3 times daily and in case of symptoms for 7 consecutive days prior to teleconsultation. Motivation was defined as number of days in which the expected number of measurements (≥3/day) were performed per number of days over the entire prescription period. Adherence was defined as number of performed measurements per number of expected measurements over the entire prescription period.Data from 990 consecutive patients with diagnosed AF [median age 64 (57-71) years, 39% female] from 10 centres were analyzed. Patients with both optimal motivation (100%) and adherence (≥100%) constituted 28% of the study population and had a lower percentage of recordings in sinus rhythm [90 (53-100%) vs. 100 (64-100%), P < 0.001] compared with others. Older age and absence of diabetes were predictors of both optimal motivation and adherence [odds ratio (OR) 1.02, 95% coincidence interval (95% CI): 1.01-1.04, P < 0.001 and OR: 0.49, 95% CI: 0.28-0.86, P = 0.013, respectively]. Patients with 100% motivation also had ≥100% adherence. Independent predictors for optimal adherence alone were older age (OR: 1.02, 95% CI: 1.00-1.04, P = 0.014), female sex (OR: 1.70, 95% CI: 1.29-2.23, P < 0.001), previous AF ablation (OR: 1.35, 95% CI: 1.03-1.07, P = 0.028). CONCLUSION: In the TeleCheck-AF project, more than one-fourth of patients had optimal motivation and adherence to app-based heart rate/rhythm monitoring. Older age and absence of diabetes were predictors of optimal motivation/adherence.


Assuntos
Fibrilação Atrial , Diabetes Mellitus , Aplicativos Móveis , Humanos , Feminino , Pessoa de Meia-Idade , Masculino , Fibrilação Atrial/diagnóstico , Frequência Cardíaca , Motivação
3.
Front Cardiovasc Med ; 8: 757587, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-35127847

RESUMO

INTRODUCTION: The TeleCheck-AF approach is an on-demand mobile health (mHealth) infrastructure incorporating mobile app-based heart rate and rhythm monitoring through teleconsultation. We evaluated feasibility and accuracy of self-reported mHealth-based AF risk factors and CHA2DS2-VASc-score in atrial fibrillation (AF) patients managed within this approach. MATERIALS AND METHODS: Consecutive patients from eight international TeleCheck-AF centers were asked to complete an app-based 10-item questionnaire related to risk factors, associated conditions and CHA2DS2-VASc-score components. Patient's medical history was retrieved from electronic health records (EHR). RESULTS: Among 994 patients, 954 (96%) patients (38% female, median age 65 years) completed the questionnaire and were included in this analysis. The accuracy of self-reported assessment was highest for pacemaker and anticoagulation treatment and lowest for heart failure and arrhythmias. Patients who knew that AF increases the stroke risk, more often had a 100% or ≥80% correlation between EHR- and app-based results compared to those who did not know (27 vs. 14% or 84 vs. 77%, P = 0.001). Thromboembolic events were more often reported in app (vs. EHR) in all countries, whereas higher self-reported hypertension and anticoagulant treatment were observed in Germany and heart failure in the Netherlands. If the app-based questionnaire alone was used for clinical decision-making on anticoagulation initiation, 26% of patients would have been undertreated and 6.1%-overtreated. CONCLUSION: Self-reported mHealth-based assessment of AF risk factors is feasible. It shows high accuracy of pacemaker and anticoagulation treatment, nevertheless, displays limited accuracy for some of the CHA2DS2-VASc-score components. Direct health care professional assessment of risk factors remains indispensable to ensure high quality clinical-decision making.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...