Can J Cardiol ; 7(9): 407-9, 1991 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-1756420

RESUMO

OBJECTIVE: Propafenone, a class IC antiarrhythmic drug, has been successful in the treatment of ventricular and supraventricular arrhythmias. This study retrospectively evaluated the efficacy of propafenone in the prevention of recurrent atrial fibrillation. DESIGN: Propafenone was given to 81 patients (49 males and 32 females, mean age 61 +/- 16 years) with recurrent atrial fibrillation. The mean dose of propafenone was 701 +/- 235 mg. Patients were monitored for recurrent arrhythmias. MAIN RESULTS: Long term follow-up over 30 +/- 1.7 months showed 31 patients (38%) remained on propafenone with complete or partial control of atrial fibrillation. The drug was stopped in 35 due to inefficacy, in 12 due to adverse effects, and in three due to desire for ablation therapy. CONCLUSION: Propafenone may be effective in some patients for long term prevention of atrial fibrillation, although efficacy may decrease over time.


Assuntos
Fibrilação Atrial/prevenção & controle , Propafenona/uso terapêutico , Fibrilação Atrial/epidemiologia , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Propafenona/administração & dosagem , Recidiva , Estudos Retrospectivos , Fatores de Tempo
3.
Pacing Clin Electrophysiol ; 12(7 Pt 1): 1049-54, 1989 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-2476740

RESUMO

Atrial pacing has the advantages of simplicity, maintenance of AV synchrony, and economy. The major detraction has been the potential for deterioration of atrioventricular conduction. In this study, we followed 43 patients with sick sinus syndrome treated with atrial (AAI) pacing. Excellent initial implant parameters were obtained in all. Three early lead repositionings were required. Minor sensing and pacing problems could all otherwise be handled by reprogramming. Follow-up for a mean of 25 +/- 20 months demonstrated excellent performance of the pacing systems. Pacing and sensing thresholds and lead impedance indicated excellent lead performance. There were no late lead failures. Nine patients have had mild deterioration in atrioventricular conduction and one of these had a change to DDD pacing at the time of elective battery change. All patients are asymptomatic. Thus, chronic atrial pacing in selected patients is safe and reliable with good chronic lead performance and low risk of subsequent conduction system disease.


Assuntos
Estimulação Cardíaca Artificial/métodos , Síndrome do Nó Sinusal/terapia , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Função Atrial , Nó Atrioventricular/fisiopatologia , Criança , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Marca-Passo Artificial , Segurança
4.
Pacing Clin Electrophysiol ; 12(6): 930-5, 1989 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-2472620

RESUMO

Transesophageal stimulation is an expeditious method of atrial pacing. Using pulse widths of 10 msec results in reduction of current requirement to values that are usually less than 15 mA. An unknown variable in transesophageal atrial pacing has been impedance. In this study, we investigated the impedance to transesophageal atrial pacing in ten patients using a stimulator with a 63 V power source capable of delivering constant current to 20 mA against an impedance of 2,000 ohms. A bipolar electrode was used to deliver stimuli with a current of 15 mA. Voltage across a known resistance and current were measured on an oscilloscope and the impedance was calculated. Pacing thresholds were also performed and ranged from 6.2 to 16.5 mA (mean 9.4 +/- 2.9 mA, SD). Impedance varied between 720 and 2,670 ohms (mean 1,750 +/- 540 ohms). The stimulator used to measure impedance in man and two other commercially available stimulators were bench tested against known resistances of 500 to 2,000 ohms. The other stimulators with power sources of 12.5 and 15 V had attenuation of the delivered current at resistances of between 1,000 and 2,000 ohms. Thus, this study has demonstrated that transesophageal atrial pacing incurs impedances two to five times greater than incurred with intracardiac pacing leads. Therefore stimulators with high power sources are required to deliver the programmed current against these impedances.


Assuntos
Estimulação Cardíaca Artificial/métodos , Fontes de Energia Elétrica , Marca-Passo Artificial , Função Atrial , Condutividade Elétrica , Eletrodos , Desenho de Equipamento , Esôfago , Humanos