Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 1 de 1
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Z Med Phys ; 27(3): 218-231, 2017 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-27567405

RESUMO

Intraoperative electron radiation therapy (IOERT) involves irradiation of an unresected tumour or a post-resection tumour bed. The dose distribution is calculated from a preoperative computed tomography (CT) study acquired using a CT simulator. However, differences between the actual IOERT field and that calculated from the preoperative study arise as a result of patient position, surgical access, tumour resection and the IOERT set-up. Intraoperative CT imaging may then enable a more accurate estimation of dose distribution. In this study, we evaluated three kilovoltage (kV) CT scanners with the ability to acquire intraoperative images. Our findings indicate that current IOERT plans may be improved using data based on actual anatomical conditions during radiation. The systems studied were two portable systems ("O-arm", a cone-beam CT [CBCT] system, and "BodyTom", a multislice CT [MSCT] system) and one CBCT integrated in a conventional linear accelerator (LINAC) ("TrueBeam"). TrueBeam and BodyTom showed good results, as the gamma pass rates of their dose distributions compared to the gold standard (dose distributions calculated from images acquired with a CT simulator) were above 97% in most cases. The O-arm yielded a lower percentage of voxels fulfilling gamma criteria owing to its reduced field of view (which left it prone to truncation artefacts). Our results show that the images acquired using a portable CT or even a LINAC with on-board kV CBCT could be used to estimate the dose of IOERT and improve the possibility to evaluate and register the treatment administered to the patient.


Assuntos
Elétrons/uso terapêutico , Imageamento Tridimensional/métodos , Neoplasias/diagnóstico por imagem , Neoplasias/radioterapia , Tomografia Computadorizada por Raios X/métodos , Tomografia Computadorizada de Feixe Cônico/instrumentação , Tomografia Computadorizada de Feixe Cônico/métodos , Humanos , Imageamento Tridimensional/instrumentação , Período Intraoperatório , Tomografia Computadorizada Multidetectores/instrumentação , Tomografia Computadorizada Multidetectores/métodos , Neoplasias/cirurgia , Dosagem Radioterapêutica , Tomografia Computadorizada por Raios X/instrumentação
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...