Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 9 de 9
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
N Biotechnol ; 79: 60-70, 2024 Mar 25.
Artigo em Inglês | MEDLINE | ID: mdl-38145650

RESUMO

After the decline of the COVID-19 pandemic, health systems were challenged by the simultaneous prevalence of different respiratory viruses causing a wide overlap in symptoms. This increased the demand for multi-virus diagnostic tests which require suitable pre-analytical workflow solutions in order to receive valid diagnostic results. In this context, the effects of specimen storage duration and temperature on the RNA/DNA copy number stability of influenza A/B, RSV A/B, SARS-CoV-2 and adenovirus were examined for four commercially available transport swab systems and saliva collection devices. The respiratory viruses were more stable in the saliva collection devices than in the transport swab systems when stored at RT or 37 °C for up to 96 h. Moreover, no differences between viral nucleic acid stability of enveloped and non-enveloped viruses were observed. The infectivity of all enveloped viruses could be inactivated by the saliva collection device from PreAnalytiX. The Norgen saliva device completely inactivated influenza A/B, while RSV A/B were partially inactivated. The non-enveloped adenovirus was inactivated by a reduction factor of 10E+ 4 in both saliva collection devices. All respiratory viruses remained infectious in the transport swab systems. Two possible transport medium additives were tested which inactivated or strongly reduced viral replication of tested enveloped viruses but had no effect on the non-enveloped adenovirus. Finally the implementation of multi-target detection procedures involving a direct amplification approach was successfully tested by spike-in of all enveloped viruses simultaneously into transport swab systems. This fast and reproducible setup presents a valuable solution for future implementations in multi-virus testing strategies.


Assuntos
Influenza Humana , Vírus , Humanos , Influenza Humana/diagnóstico , Pandemias , Vírus/genética , Manejo de Espécimes/métodos , Reação em Cadeia da Polimerase
2.
PLoS One ; 16(7): e0253401, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34228726

RESUMO

The field of liquid biopsy has seen extensive growth in recent decades, making it one of the most promising areas in molecular diagnostics. Circulating cell-free DNA (ccfDNA) especially is used as an analyte in a growing number of diagnostic assays. These assays require specified preanalytical workflows delivering ccfDNA in qualities and quantities that facilitate correct and reliable results. As each step and component used in the preanalytical process has the potential to influence the assay sensitivity and other performance characteristics, it is key to find an unbiased experimental setup to test these factors in diagnostic or research laboratories. We defined one such setup by using blood from healthy subjects and commercially available products for blood collection, spike-in material, ccfDNA isolation, and qPCR assays. As the primary read-out, we calculated the probit model-based LOD95 (limit of detection of the 95th percentile) from the qPCR assay results. In a proof of principle study we tested two different but widely used blood ccfDNA profile stabilization technologies in blood collection tubes, the Cell-Free DNA BCT and the PAXgene Blood ccfDNA Tube. We tested assays for three different EGFR gene mutations and one BRAF gene mutation. The study design revealed differences in performance between the two tested technologies for all four mutations. In conclusion, we successfully established a blueprint for a test procedure capable of verifying and validating a liquid biopsy workflow from blood collection to the analytical result.


Assuntos
Sistema Livre de Células , DNA/metabolismo , Adolescente , Adulto , Idoso , Sistema Livre de Células/química , DNA/análise , DNA/sangue , DNA/genética , Feminino , Genes erbB-1/genética , Humanos , Masculino , Pessoa de Meia-Idade , Reação em Cadeia da Polimerase Multiplex , Mutação/genética , Proteínas Proto-Oncogênicas B-raf/genética , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Adulto Jovem
3.
Clin Chem ; 66(1): 149-160, 2020 01 01.
Artigo em Inglês | MEDLINE | ID: mdl-31628139

RESUMO

BACKGROUND: In cancer patients, circulating cell-free DNA (ccfDNA) can contain tumor-derived DNA (ctDNA), which enables noninvasive diagnosis, real-time monitoring, and treatment susceptibility testing. However, ctDNA fractions are highly variable, which challenges downstream applications. Therefore, established preanalytical work flows in combination with cost-efficient and reproducible reference materials for ccfDNA analyses are crucial for analytical validity and subsequently for clinical decision-making. METHODS: We describe the efforts of the Innovative Medicines Initiative consortium CANCER-ID (http://www.cancer-id.eu) for comparing different technologies for ccfDNA purification, quantification, and characterization in a multicenter setting. To this end, in-house generated mononucleosomal DNA (mnDNA) from lung cancer cell lines carrying known TP53 mutations was spiked in pools of plasma from healthy donors generated from 2 different blood collection tubes (BCTs). ccfDNA extraction was performed at 15 partner sites according to their respective routine practice. Downstream analysis of ccfDNA with respect to recovery, integrity, and mutation analysis was performed centralized at 4 different sites. RESULTS: We demonstrate suitability of mnDNA as a surrogate for ccfDNA as a process quality control from nucleic acid extraction to mutation detection. Although automated extraction protocols and quantitative PCR-based quantification methods yielded the most consistent and precise results, some kits preferentially recovered spiked mnDNA over endogenous ccfDNA. Mutated TP53 fragments derived from mnDNA were consistently detected using both next-generation sequencing-based deep sequencing and droplet digital PCR independently of BCT. CONCLUSIONS: This comprehensive multicenter comparison of ccfDNA preanalytical and analytical work flows is an important contribution to establishing evidence-based guidelines for clinically feasible (pre)analytical work flows.


Assuntos
Ácidos Nucleicos Livres/metabolismo , Sequenciamento de Nucleotídeos em Larga Escala/métodos , Reação em Cadeia da Polimerase em Tempo Real/métodos , Coleta de Amostras Sanguíneas , Linhagem Celular Tumoral , Ácidos Nucleicos Livres/química , Ácidos Nucleicos Livres/normas , DNA Tumoral Circulante/sangue , Análise Mutacional de DNA , Sequenciamento de Nucleotídeos em Larga Escala/normas , Humanos , Neoplasias/genética , Neoplasias/patologia , Nucleossomos/genética , Polimorfismo de Nucleotídeo Único , Fase Pré-Analítica , Reação em Cadeia da Polimerase em Tempo Real/normas , Padrões de Referência , Proteína Supressora de Tumor p53/genética
4.
Radiat Res ; 192(2): 208-218, 2019 08.
Artigo em Inglês | MEDLINE | ID: mdl-31211643

RESUMO

Radiological exposure scenarios involving large numbers of people require a rapid and high-throughput method to identify the unexposed, and those exposed to low- and high-dose radiation. Those with high-dose exposure, e.g., >2 Gy and depending on host characteristics, may develop severe hematological acute radiation syndrome (HARS), requiring hospitalization and treatment. Previously, we identified a set of genes that discriminated these clinically relevant groups. In the current work, we examined the utility of gene expression changes to classify 1,000 split blood samples into HARS severity scores of H0, H1 and H2-4, with the latter indicating likely hospitalization. In several previous radiation dose experiments, we determined that these HARS categories corresponded, respectively, to doses of 0 Gy (unexposed), 0.5 Gy and 5 Gy. The main purpose of this work was to assess the rapidity of blood sample processing using targeted next-generation sequencing (NGS). Peripheral blood samples from two healthy donors were X-ray irradiated in vitro and incubated at 37°C for 24 h. A total of 1,000 samples were evaluated by laboratory personnel blinded to the radiation dose. Changes in gene expression of FDXR, DDB2, POU2AF1 and WNT3 were examined with qRT-PCR as positive controls. Targeted NGS (TREX) was used on all samples for the same four genes. Agreement using both methods was almost 78%. Using NGS, all 1,000 samples were processed within 30 h. Classification of the HARS severity categories corresponding to radiation dose had an overall agreement ranging between 90-97%. Depending on the end point, either a combination of all genes or FDXR alone (H0 HARS or unexposed) provided the best classification. Using this optimized automated methodology, we assessed 100× more samples approximately three times faster compared to standard cytogenetic studies. We showed that a small set of genes, rather than a complex constellation of genes, provided robust positive (97%) and negative (97%) predictive values for HARS categories and radiation doses of 0, 0.5 and 5 Gy. The findings of this study support the potential utility of early radiation-induced gene expression changes for high-throughput biodosimetry and rapid identification of irradiated persons in need of hospitalization.


Assuntos
Síndrome Aguda da Radiação/diagnóstico , Síndrome Aguda da Radiação/genética , Perfilação da Expressão Gênica , Exposição à Radiação/efeitos adversos , Triagem/métodos , Síndrome Aguda da Radiação/sangue , Síndrome Aguda da Radiação/etiologia , Adulto , Reações Falso-Positivas , Feminino , Humanos , Masculino , Fatores de Tempo , Adulto Jovem
5.
Curr Pathobiol Rep ; 6(4): 275-286, 2018.
Artigo em Inglês | MEDLINE | ID: mdl-30595972

RESUMO

PURPOSE OF REVIEW: Liquid biopsy analyses based on circulating cell-free nucleic acids, circulating tumor cells or other diseased cells from organs, and exosomes or other microvesicles in blood offer new means for non-invasive diagnostic applications. The main goal of this review is to explain the importance of preserving whole blood specimens after blood draw for use as liquid biopsies, and to summarize preservation solutions that are currently available. RECENT FINDINGS: Despite the great potential of liquid biopsies for diagnostics and disease management, besides non-invasive prenatal testing (NIPT), only a few liquid biopsy applications are fully implemented for routine in vitro diagnostic testing. One major barrier is the lack of standardized pre-analytical workflows, including the collection of consistent quality blood specimens and the generation of good-quality plasma samples therefrom. Broader use of liquid biopsies in clinical routine applications therefore requires improved pre-analytical procedures to enable high-quality specimens to obtain unbiased analyte profiles (DNA, RNA, proteins, etc.) as they are in the patient's body. SUMMARY: A growing number of stabilizing reagents and dedicated blood collection tubes are available for the post-collection preservation of circulating cell-free DNA (ccfDNA) profiles in whole blood. In contrast, solutions for the preservation of circulating tumor cells (CTC) that enable both, enumeration and molecular analyses are rare. Solutions for extracellular vesicle (EV) populations, including exosomes, do not yet exist.

6.
Stud Health Technol Inform ; 238: 92-95, 2017.
Artigo em Inglês | MEDLINE | ID: mdl-28679895

RESUMO

The "research apartment Halberstadtstraße" (HSS) in Braunschweig, Germany, is the attempt to realize a personal living environment as a room for diagnostics and therapy with the support of health-enabling and ambient assistive technologies (HEAAT). As a research tool, the HSS will enable the efficient implementation of new HEAAT and help in evaluating these under controlled real-life conditions. This new research tool will therefore be the missing link between artificial laboratory and complete real-life conditions. For a defined period, selected subjects can live in the HSS and experience the benefit of such a "Smart Home". The academic support in a real-life controlled living-environment enables continuous monitoring of behavior patterns and habits of healthy and ill persons, evaluation of new HEAAT, and conduction of requirements analysis and acceptance studies.


Assuntos
Tecnologia Biomédica , Pesquisa , Tecnologia Assistiva , Meio Ambiente , Alemanha , Comportamentos Relacionados com a Saúde , Humanos
7.
Methods Mol Biol ; 822: 307-38, 2012.
Artigo em Inglês | MEDLINE | ID: mdl-22144209

RESUMO

This chapter describes several methods for the isolation of miRNAs from peripheral whole blood samples or constituent fractions thereof, such as peripheral blood mononuclear cells, plasma, and serum. The methods described here are recently introduced protocols dedicated to the isolation of total RNAs including small RNAs, e.g., miRNeasy Kit and PAXgene Blood miRNA Kit, or alternatively for the enrichment of low-molecular-weight RNA (LMW RNA) fractions including small RNAs, e.g., using the miRNeasy Kit. Furthermore, modifications of classical RNA purification protocols to facilitate the recovery of small RNAs are highlighted.


Assuntos
MicroRNAs/isolamento & purificação , Biomarcadores/sangue , Humanos , Leucócitos Mononucleares/metabolismo , MicroRNAs/análise , MicroRNAs/sangue , Controle de Qualidade , RNA/análise , RNA/sangue , RNA/isolamento & purificação
8.
J Mol Diagn ; 12(3): 335-44, 2010 May.
Artigo em Inglês | MEDLINE | ID: mdl-20228267

RESUMO

Blood-based mRNA expression profiling has already become an important issue in clinical applications. More recently, the characterization of the small RNA transcriptome offers additional avenues for diagnostic approaches. However, when applying miRNA expression profiling in routine clinical settings, the method of RNA preservation and the manner of RNA extraction as well as the reliability of the miRNA profiling procedure have to be carefully considered. Here we evaluate a recently introduced bead array-based technology as a robust method for the generation of blood-based human miRNA expression profiles. Importantly the comparison of different RNA extraction strategies resulted in dissimilar profiles depending on the RNA extraction method as well as on the underlying source. Expression profiles obtained from peripheral mononuclear cells (PBMCs) substantially differed from those of whole blood samples, whereby both sources per se yielded reproducible and reliable results. Expression profiles were also distinct when using either fresh or frozen PBMCs. Moreover RNA size fractioning resulted in discriminative miRNA expression profiles compared with total RNA based profiles. This study outlines important steps toward the establishment of a robust strategy for blood-based miRNA profiling and provides a reliable strategy for its implementation in routine handling for diagnostic purposes.


Assuntos
MicroRNAs/sangue , Perfilação da Expressão Gênica/métodos , Humanos , Leucócitos Mononucleares/metabolismo , Análise de Sequência com Séries de Oligonucleotídeos , Reação em Cadeia da Polimerase
9.
J Mol Diagn ; 9(4): 452-8, 2007 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-17690207

RESUMO

We have developed a procedure for isolation of microRNA and genomic DNA in addition to total RNA from whole blood stabilized in PAXgene Blood RNA tubes. The procedure is based on automatic extraction on a BioRobot MDx and includes isolation of DNA from a fraction of the stabilized blood and recovery of small RNA species that are otherwise lost. The procedure presented here is suitable for large-scale experiments and is amenable to further automation. Procured total RNA and DNA was tested using Affymetrix Expression and single-nucleotide polymorphism GeneChips, respectively, and isolated microRNA was tested using spotted locked nucleic acid-based microarrays. We conclude that the yield and quality of total RNA, microRNA, and DNA from a single PAXgene blood RNA tube is sufficient for downstream microarray analysis.


Assuntos
Coleta de Amostras Sanguíneas/métodos , DNA/isolamento & purificação , MicroRNAs/isolamento & purificação , Análise de Sequência com Séries de Oligonucleotídeos , Genoma Humano/genética , Humanos , Polimorfismo de Nucleotídeo Único/genética , Fatores de Tempo
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...