Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
J Invasive Cardiol ; 22(4): 175-8, 2010 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-20351388

RESUMO

UNLABELLED: We investigated the prevalence of vascular complications after PCI following hemostasis in 190 patients (67% men and 33% women, mean age 64 years) treated with the AngioSeal vascular closure device (St. Jude Medical, Austin, Texas) versus 238 patients (67% men and 33% women, mean age 64 years) treated with the Mynx vascular closure device (AccessClosure, Mountain View, California). RESULTS: Death, myocardial infarction or stroke occurred in none of the 190 patients (0%) treated with the AngioSeal versus none of 238 patients (0%) treated with the Mynx. Major vascular complications occurred in 4 of 190 patients (2.1%) treated with the AngioSeal versus 5 of 238 patients (2.1%) treated with the Mynx (p not significant). Major vascular complications in patients treated with the AngioSeal included removal of a malfunctioning device (1.1%), hemorrhage requiring intervention (0.5%) and hemorrhage with a loss of > 3g Hgb (0.5%). The major vascular complications in patients treated with the Mynx included retroperitoneal bleeding requiring surgical intervention (0.8%), pseudoaneurysm with surgical repair (0.8%) and hemorrhage with a loss of > 3g Hgb (0.4%). These complications were not significantly different between the two vascular closure devices (p = 0.77). Minor complications included hematoma > 5 cm (0.5%, n = 1) within the AngioSeal group, as well as procedure failure requiring > 30 minutes of manual compression after device deployment, which occurred in 7 out of 190 patients (3.7%) treated with the AngioSeal versus 22 of 238 patients with the Mynx (9.2%) (p = 0.033). CONCLUSIONS: Major vascular complications after PCI following hemostasis with vascular closure devices occurred in 2.1% of 190 patients treated with the AngioSeal vascular closure device versus 2.1% of 238 patients treated with the Mynx vascular closure device (p not significant). The Mynx vascular closure device appears to have a higher rate of device failure.


Assuntos
Falso Aneurisma/epidemiologia , Falso Aneurisma/etiologia , Angioplastia Coronária com Balão/efeitos adversos , Angioplastia Coronária com Balão/instrumentação , Cateterismo Cardíaco/instrumentação , Hemostasia Cirúrgica/efeitos adversos , Hemostasia Cirúrgica/instrumentação , Complicações Pós-Operatórias/epidemiologia , Complicações Pós-Operatórias/etiologia , Hemorragia Pós-Operatória/epidemiologia , Hemorragia Pós-Operatória/etiologia , Idoso , Falso Aneurisma/cirurgia , Estudos Transversais , Desenho de Equipamento , Análise de Falha de Equipamento , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Complicações Pós-Operatórias/cirurgia , Hemorragia Pós-Operatória/cirurgia , Reoperação , Espaço Retroperitoneal/cirurgia
2.
J Org Chem ; 67(5): 1703-4, 2002 Mar 08.
Artigo em Inglês | MEDLINE | ID: mdl-11871909

RESUMO

A novel, unique way to cleave the carbon-carbon bond in aryl alkyl ketones under mild, neutral conditions is described. Treatment of aryl alkyl ketones in a refluxing mixture of N,N-dimethylformamide dimethyl acetal and methanol for 16 h provided aryl carboxylic esters. The scope and limitations of the reaction are discussed. Useful yields of the reaction can be obtained with electron-deficient aryl groups, and the yields are higher when the alkyl group is larger than a methyl group. Studies toward elucidation of the reaction mechanism led to a proposed mechanism that is consistent with all the observations.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...