Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
1.
Cathet Cardiovasc Diagn ; 32(2): 147-56, 1994 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-8062370

RESUMO

The purpose of this study was to determine acute recoil of the vessel wall immediately after Wiktor stent implantation in native coronary arteries of 77 consecutive patients and to assess whether there was compression or "late recoil" of the stent itself at long-term follow-up. Furthermore, the relationship between recoil and a number of clinical, angiographic, and procedural variables was studied in addition to the relation between acute recoil renarrowing or restenosis was assessed. All angiograms were analyzed with the Cardiovascular Angiography Analysis System using automated edge detection. Acute recoil was defined by the difference between the mean diameter of the fully expanded balloon on which the stent was mounted and the mean diameter of the stented segment. Late recoil was calculated by comparing the mean diameter of the stent itself immediately after implantation and at follow-up without opacification of the vessel. Acute recoil amounted to 0.25 +/- 0.32 mm or 8.2%. Multivariate analysis identified sex (coefficient = -0.20, p = 0.04) and stent/artery ratio (coefficient = 0.99, p = 0.0001) as the only independent predictors of acute recoil. "Late recoil" of the stent itself was not observed. The overall difference between the mean diameter of the stent itself immediately after implantation and at follow-up was -0.15 +/- 0.33 mm, suggesting an overall increase in diameter of 5.0%. There was no relation between acute recoil and late restenosis. On the contrary, there was a trend towards a greater degree of recoil in patients without restenosis. Moreover, linear regression analysis disclosed a weak but negative correlation between acute recoil and a loss in minimal luminal diameter (coefficient: -0.55, p = 0.04). The Wiktor stent effectively scaffolds the instrumented vessel. Only a minimal amount of acute recoil was noted, which did not contribute to late luminal renarrowing or restenosis. In addition, no late compression of the stent itself was observed. These data suggest that tissue ingrowth into the lumen of the stented segment is the main cause of late luminal renarrowing after stent implantation.


Assuntos
Doença das Coronárias/terapia , Stents , Idoso , Angiografia Coronária , Doença das Coronárias/patologia , Vasos Coronários/patologia , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade
2.
Am J Cardiol ; 72(2): 165-70, 1993 Jul 15.
Artigo em Inglês | MEDLINE | ID: mdl-8328378

RESUMO

Intracoronary stenting has been proposed as an adjunct to balloon angioplasty to improve the immediate and long-term results. However, late luminal narrowing has been reported following the implantation of a variety of stents. One of the studies conducted with the Wiktor stent is a prospective registry designed to evaluate the feasibility, safety and efficacy of elective stent implantation in patients with documented restenosis of a native coronary artery. To identify angiographic variables predicting recurrence of restenosis, the angiograms of the first 91 patients with successful stent implantation and without clinical evidence of (sub)acute thrombotic stent occlusion were analyzed with the Computer Assisted Angiographic Analysis System using automated edge detection. The incidence of restenosis was 44% by patient and 45% by stent according to the 0.72 mm criterion, and 30% by patient and 29% by stent according to the 50% diameter stenosis criterion. The risk for restenosis for several angiographic variables was determined using an univariate analysis and is expressed as odds ratio with corresponding confidence interval. The only statistically significant predictor of restenosis was the relative gain when it exceeded 0.48 using the 0.72 mm criterion (odds ratio 2.7, 95% confidence interval 1.1-6.4). Furthermore, the relation between the relative gain (increase in minimal luminal diameter normalized to vessel size) as angiographic index of vessel wall injury and relative loss (decrease in minimal luminal diameter normalized to vessel size) as index of neointimal thickening was analyzed using a linear regression analysis. When using the categorical approach to address restenosis, there is an increased risk for recurrent restenosis when the relative gain exceeds 0.48. The continuous approach underscores this concept by indicating a weak but positive relation between the relative gain and relative loss.


Assuntos
Angioplastia Coronária com Balão , Angiografia Coronária , Doença das Coronárias/diagnóstico por imagem , Stents , Idoso , Intervalos de Confiança , Doença das Coronárias/epidemiologia , Doença das Coronárias/terapia , Feminino , Seguimentos , Humanos , Incidência , Masculino , Pessoa de Meia-Idade , Prognóstico , Recidiva , Análise de Regressão , Risco
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA