Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
J Appl Toxicol ; 2024 May 10.
Artigo em Inglês | MEDLINE | ID: mdl-38730557

RESUMO

In a chemical mass casualty incident requiring skin decontamination, dry removal using absorbent materials may be beneficial to enable immediate decontamination. The efficacy of absorbent materials has therefore been evaluated, alone or procedures including both dry and wet decontamination, following skin exposure to two low volatile toxic chemicals using an in vitro human skin penetration model. Additionally, removal using active carbon wipes was evaluated with or without the Dahlgren Decon solution. All dry decontamination procedures resulted in a significantly decreased skin penetration rate of the industrial chemical 2-butoxyethanol compared to the control without decontamination. Wet decontamination following dry absorption significantly improved the efficacy compared to dry removal alone. Dry decontamination post-exposure to the chemical warfare nerve agent VX showed no decontamination efficacy. However, dry and wet decontamination resulted in a decreased agent skin penetration rate during the last hour of the experiment. At -15°C, significantly reduced VX skin penetration rates were demonstrated for both dry decontamination alone and the dry and wet decontamination procedure. The Dahlgren Decon solution significantly reduced the amount of VX penetrating the skin, but the active carbon wipe alone did not impact the skin penetration rate. In conclusion, absorbent materials are beneficial for the removal of low-volatile chemicals from the skin, but the degree of efficacy varies between chemicals. Despite the variability, immediate dry decontamination using available absorbent materials prior to wet decontamination is recommended as a general procedure for skin decontamination. The procedure should also be prioritized in cold-weather conditions to prevent patient hypothermia.

2.
J Appl Toxicol ; 42(6): 961-969, 2022 06.
Artigo em Inglês | MEDLINE | ID: mdl-34850419

RESUMO

Skin decontamination in cold weather temperatures might be challenging due to the aggravating circumstances. However, no information is available on the efficacy of commonly used procedures in winter conditions. Therefore, the efficacy of the reactive skin decontamination lotion (RSDL) and soapy water decontamination following skin exposure to the nerve agent VX was evaluated at three ambient air temperatures (-5°C, -15°C and room temperature). Experiments were performed in vitro using human dermatomed skin. The ability of RSDL to degrade VX at the three different air temperatures was separately evaluated. The ambient air temperature in experiments without decontamination did not influence the penetration rate of VX through skin. RSDL decontamination was highly efficient in removing VX from skin when performed in all three ambient temperatures, despite the slower agent degradation rate of VX at the lower temperatures. Decontamination with soapy water at RT resulted in an increased skin penetration of VX compared with the control without decontamination; however, in colder temperatures the VX skin penetration was similar to the corresponding control without decontamination. At RT, dry removal prior to washing with soapy water did not improve decontamination of VX compared with washing solely with soapy water. This study demonstrated high efficacy of RSDL decontamination following skin exposure to VX also at cold temperatures. The previously reported 'wash-in' effect of soapy water on VX skin penetration was reduced at cold temperatures. Altogether, this study found a scientific basis to establish guidelines for skin decontamination of chemical casualties at cold weather temperatures.


Assuntos
Substâncias para a Guerra Química , Compostos Organotiofosforados , Temperatura Baixa , Descontaminação/métodos , Humanos , Pele , Sabões , Temperatura , Água/metabolismo , Tempo (Meteorologia)
3.
Aerobiologia (Bologna) ; 31(3): 271-281, 2015.
Artigo em Inglês | MEDLINE | ID: mdl-32214629

RESUMO

The aim of this study was to collect and identify airborne bacteria in Norway, Sweden and Finland and to compare three different technologies for identifying collected airborne bacterial isolates: the "gold standard" method 16S rDNA sequencing, MALDI-TOF MS using the MALDI Biotyper 2.0 and the MIDI Sherlock® Microbial Identification System (MIDI MIS system). Airborne bacteria were collected during three different periods from May to October 2009 using air sampling directly on agar plates. A total of 140 isolates were collected during three sampling campaigns, and 74 % (103) of these isolates were analyzed by all three methods. The dominant genera in Norway and Finland were the gram-positive bacteria Bacillus and Staphylococcus, whereas the gram-negative bacterium Acinetobacter was the dominant genus in Sweden. Using 16S rDNA sequencing, MALDI-TOF MS and MIDI MIS analysis, 83, 79 and 75 %, respectively, of the isolates were identified and assigned to order or higher taxonomic levels. In this study, the MALDI-TOF MS combining with the MALDI Biotyper 2.0 classification tool was demonstrated to be a fast and reliable alternative for identifying the airborne bacterial isolates. These studies have increased knowledge about the airborne bacterial background in outdoor air, which can be useful for evaluating and improving the operational performance of biological detectors in various environments. To our knowledge, this is the first time that 16S rDNA sequencing, MALDI-TOF MS and MIDI MIS analysis technologies have been compared for their efficiency in identifying airborne bacteria.

4.
J Am Chem Soc ; 136(11): 4125-8, 2014 Mar 19.
Artigo em Inglês | MEDLINE | ID: mdl-24597942

RESUMO

An array of fluorogenic probes is able to discriminate between nerve agents, sarin, soman, tabun, VX and their mimics, in water or organic solvent, by qualitative fluorescence patterns and quantitative multivariate analysis, thus making the system suitable for the in-the-field detection of traces of chemical warfare agents as well as to differentiate between the real nerve agents and other related compounds.


Assuntos
Substâncias para a Guerra Química/química , Fluorescência , Corantes Fluorescentes/química , Substâncias para a Guerra Química/síntese química , Corantes Fluorescentes/síntese química , Estrutura Molecular
5.
J Magn Reson ; 157(1): 156-9, 2002 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-12202145

RESUMO

The anisotropy, D(parallel)/D( perpendicular ), of water diffusion in fully hydrated bilayers of dimyristoylphosphatidylcholine at 29 degrees C has been measured by pulsed magnetic field gradient (pfg) NMR. By using NMR imaging hardware to produce magnetic field gradients in an arbitrary direction with respect to a stack of macroscopically aligned lipid bilayers, translational diffusion of water was measured as a function of the angle between the direction of the magnetic field gradient and the normal of the lipid membrane. The observed diffusion coefficient is found to depend strongly on this angle. The anisotropy cannot be accurately determined due to the very small value of D( perpendicular ), but a lower limit of about 70 can be estimated from the observed diffusion coefficients. The results are discussed in terms of the relatively low permeability of water across the lipid bilayer, instrumental limitations, and/or possible defects in the lamellae.


Assuntos
Dimiristoilfosfatidilcolina/química , Bicamadas Lipídicas/química , Espectroscopia de Ressonância Magnética/métodos , Anisotropia , Difusão
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...