Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 63
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Rev Sci Instrum ; 92(12): 123510, 2021 Dec 01.
Artigo em Inglês | MEDLINE | ID: mdl-34972417

RESUMO

The target parameters of negative ion sources regarding the current of extracted negative ions, the current of co-extracted electrons, the pulse duration, the duty cycle, and the availability of the system can be rather strict. Knowledge of plasma parameters such as the electron temperature and the electron density and also properties of molecules or photon fluxes can provide essential insights into the ion source physics needed for reaching the target parameters. Emission spectroscopy is a non-invasive tool enabling access to line-of-sight averaged values of plasma parameters. This paper gives an overview of the application of emission spectroscopy in the visible range, extended for long wavelengths to the near-IR and for short wavelengths to the vacuum ultraviolet (VUV)/UV range. The amount of information to be gained from measured emission spectra is directly correlated with the effort invested for calibrating the system. Examples are given, ranging from simple monitoring to the complex evaluation of molecular spectra and the determination of highly energetic photon fluxes in the VUV/UV range. Additional emphasis is laid on the population models needed for the interpretation of measured spectra.

2.
Rev Sci Instrum ; 91(1): 013510, 2020 Jan 01.
Artigo em Inglês | MEDLINE | ID: mdl-32012532

RESUMO

The large RF negative hydrogen (deuterium) ion source at the ELISE test facility (half of the ITER-NBI source size) has been equipped with a Cavity Ring-Down Spectroscopy (CRDS) system, in order to measure the negative hydrogen (deuterium) ion density in the region in front of the plasma grid (first grid of the extraction system). The challenge of this diagnostic for ELISE relies on the large size of the source and therefore on the plasma length across which the measurements are performed as well as the long pulses at RF power, which can affect the cavity mirror reliability. A dedicated experiment on the mirror reliability was performed, ensuring the feasibility of measurements for long pulses (several hundred seconds) at high RF power. Two horizontal lines of sight were dedicated to CRDS: the measured density was in the range between 4 × 1016 and 1 × 1017 m-3, with a slightly higher density for the bottom lines of sight, for both the isotope hydrogen and deuterium. Different temporal evolution was observed for the two isotopes, showing a higher instability for the deuterium case: this is in correlation with the extracted negative ion current density and inversely correlated with the coextracted electron current density. The CRDS system allowed performing the first measurements of negative ion density for a long pulse (1000 s) in a large source: the temporal behavior and the effect of the beam extraction will also be discussed.

3.
Rev Sci Instrum ; 90(11): 113304, 2019 Nov 01.
Artigo em Inglês | MEDLINE | ID: mdl-31779429

RESUMO

Negative ion sources for neutral beam injection (NBI) in fusion experiments are based on the surface production of H- or D- on cesiated low work function surfaces. In the recent years, it was demonstrated at the large RF driven ion source of the ELISE (Extraction from a Large Ion Source Experiment) test facility that the requirements for the ITER NBI systems can be fulfilled by hydrogen. This is a big step toward the first operational period of ITER, planned for up to 2035. However, for the following operational period, neutral beam systems working in deuterium are needed. Operation of negative hydrogen ion sources in deuterium is significantly more demanding than in hydrogen: the amount of coextracted electrons is much higher and their increase during pulses is much more pronounced, limiting the achievable performance. This paper presents the results of investigations aimed to improve the insight into the physics related to this isotope effect. Due to the higher atomic mass of deuterium, cesium is removed much more effectively from reservoirs at the walls, resulting in a depletion of these reservoirs and a strongly increased cesium density in the plasma. Additionally, a correlation between the fluxes of charged particles toward the inner ion source surfaces and the coextracted electrons is identified.

4.
Rev Sci Instrum ; 89(10): 10I139, 2018 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-30399769

RESUMO

Along the route to the development of a neutral beam injector for ITER, the Padua based Source for Production of Ion of Deuterium Extracted from Rf plasma (SPIDER) and megavolt ITER injector and concept advancement facilities will make use of neutron diagnostics to quantify the homogeneity of the neutral beam profile by measuring the map of the neutron emission from the beam dump with the close-contact neutron emission surface mapping (CNESM) system. Neutrons are here produced from beam-target reactions between the deuterium beam and the deuterons previously adsorbed in the calorimeter. In order to aid the interpretation of the diagnostic data, a dedicated experiment on neutron emission from beam-target reactions with beam parameters approaching those expected at SPIDER has been performed at the Extraction from a Large Ion Source Experiment (ELISE) neutral beam test facility. The time trace of neutron emission has been measured using a calibrated liquid scintillator detector at increasing power densities on the target. Compared to calculations based on the local mixing model, a systematic discrepancy was observed exceeding the statistical accuracy of the measurements and increasing as a linear function of the power density. The data are used to derive an empirical temperature dependent correction for applications to neutron measurements at SPIDER.

5.
Rev Sci Instrum ; 89(5): 052102, 2018 May.
Artigo em Inglês | MEDLINE | ID: mdl-29864838

RESUMO

The ITER neutral beam system will be equipped with large radio frequency (RF) driven negative ion sources, with a cross section of 0.9 m × 1.9 m, which have to deliver extracted D- ion beams of 57 A at 1 MeV for 1 h. On the extraction from a large ion source experiment test facility, a source of half of this size is being operational since 2013. The goal of this experiment is to demonstrate a high operational reliability and to achieve the extracted current densities and beam properties required for ITER. Technical improvements of the source design and the RF system were necessary to provide reliable operation in steady state with an RF power of up to 300 kW. While in short pulses the required D- current density has almost been reached, the performance in long pulses is determined in particular in Deuterium by inhomogeneous and unstable currents of co-extracted electrons. By application of refined caesium evaporation and distribution procedures, and reduction and symmetrization of the electron currents, considerable progress has been made and up to 190 A/m2 D-, corresponding to 66% of the value required for ITER, have been extracted for 45 min.

6.
Rev Sci Instrum ; 89(5): 052001, 2018 May.
Artigo em Inglês | MEDLINE | ID: mdl-29864857

RESUMO

Particle-in-cell (PIC) codes are used since the early 1960s for calculating self-consistently the motion of charged particles in plasmas, taking into account external electric and magnetic fields as well as the fields created by the particles itself. Due to the used very small time steps (in the order of the inverse plasma frequency) and mesh size, the computational requirements can be very high and they drastically increase with increasing plasma density and size of the calculation domain. Thus, usually small computational domains and/or reduced dimensionality are used. In the last years, the available central processing unit (CPU) power strongly increased. Together with a massive parallelization of the codes, it is now possible to describe in 3D the extraction of charged particles from a plasma, using calculation domains with an edge length of several centimeters, consisting of one extraction aperture, the plasma in direct vicinity of the aperture, and a part of the extraction system. Large negative hydrogen or deuterium ion sources are essential parts of the neutral beam injection (NBI) system in future fusion devices like the international fusion experiment ITER and the demonstration reactor (DEMO). For ITER NBI RF driven sources with a source area of 0.9 × 1.9 m2 and 1280 extraction apertures will be used. The extraction of negative ions is accompanied by the co-extraction of electrons which are deflected onto an electron dump. Typically, the maximum negative extracted ion current is limited by the amount and the temporal instability of the co-extracted electrons, especially for operation in deuterium. Different PIC codes are available for the extraction region of large driven negative ion sources for fusion. Additionally, some effort is ongoing in developing codes that describe in a simplified manner (coarser mesh or reduced dimensionality) the plasma of the whole ion source. The presentation first gives a brief overview of the current status of the ion source development for ITER NBI and of the PIC method. Different PIC codes for the extraction region are introduced as well as the coupling to codes describing the whole source (PIC codes or fluid codes). Presented and discussed are different physical and numerical aspects of applying PIC codes to negative hydrogen ion sources for fusion as well as selected code results. The main focus of future calculations will be the meniscus formation and identifying measures for reducing the co-extracted electrons, in particular for deuterium operation. The recent results of the 3D PIC code ONIX (calculation domain: one extraction aperture and its vicinity) for the ITER prototype source (1/8 size of the ITER NBI source) are presented.

8.
Rev Sci Instrum ; 87(2): 02B113, 2016 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-26931995

RESUMO

A spectrally selective imaging system has been installed in the RF negative ion source in the International Thermonuclear Experimental Reactor-relevant negative ion beam test facility ELISE (Extraction from a Large Ion Source Experiment) to investigate distribution of hydrogen Balmer-α emission (Hα) close to the production surface of hydrogen negative ion. We selected a GigE vision camera coupled with an optical band-path filter, which can be controlled remotely using high speed network connection. A distribution of Hα emission near the bias plate has been clearly observed. The same time trend on Hα intensities measured by the imaging diagnostic and the optical emission spectroscopy is confirmed.

9.
Rev Sci Instrum ; 87(2): 02B307, 2016 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-26932035

RESUMO

The large-scale RF-driven ion source of the test facility extraction from a large ion source experiment is aimed to deliver an accelerated ion current of 20 A D(-) (23 A H(-)) with an extracted electron-to-ion ratio below one for up to 1 h. Since the first plasma pulses for 20 s in volume operation in early 2013, followed by caesiation of the ion source, substantial progress has been achieved in extending the pulse length and the RF power. The record pulses in hydrogen are stable 400 s pulses with an extracted ion current of 18.3 A at 180 kW total RF power and 9.3 A at 80 kW stable for 1 h. For deuterium pulse, length and RF power are limited by the amount of co-extracted electrons.

10.
Rev Sci Instrum ; 87(2): 02B315, 2016 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-26932043

RESUMO

The performance of large negative ion sources used in neutral beam injection systems is in long pulses mainly determined by the increase of the currents of co-extracted electrons. This is in particular a problem in deuterium and limits the ion currents which are for long pulses below the requirements for the ITER source. In the source of the ELISE test facility, the magnetic field in front of the first grid, which is essential to reduce the electron current, is generated by a current of several kA flowing through the plasma facing grid. Weakening of this field by the addition of permanent magnets placed close to the lateral walls has led to a reduction of the electron current by a factor three without loss of ion current when source was operated in volume production. If this effect can be validated for the cesiated source, it would be a large step towards achieving the ITER parameter in long pulses.

11.
Rev Sci Instrum ; 87(2): 02B319, 2016 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-26932047

RESUMO

NIO1 (Negative Ion Optimization 1) is a compact and flexible radio frequency H(-) ion source, developed by Consorzio RFX and INFN-LNL. The aim of the experimentation on NIO1 is the optimization of both the production of negative ions and their extraction and beam optics. In the initial phase of its commissioning, NIO1 was operated with nitrogen, but now the source is regularly operated also with hydrogen. To evaluate the source performances, an optical emission spectroscopy diagnostic was installed. The system includes a low resolution spectrometer in the spectral range of 300-850 nm and a high resolution (50 pm) one, to study, respectively, the atomic and the molecular emissions in the visible range. The spectroscopic data have been interpreted also by means of a collisional-radiative model developed at IPP Garching. Besides the diagnostic hardware and the data analysis methods, the paper presents the first plasma measurements across a transition to the full H mode, in a hydrogen discharge. The characteristic signatures of this transition in the plasma parameters are described, in particular, the sudden increase of the light emitted from the plasma above a certain power threshold.

12.
Rev Sci Instrum ; 85(2): 02B301, 2014 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-24593578

RESUMO

Decreasing the co-extracted electron current while simultaneously keeping negative ion (NI) current sufficiently high is a crucial issue on the development plasma source system for ITER Neutral Beam Injector. To support finding the best extraction conditions the 3D Particle-in-Cell Monte Carlo Collision electrostatic code ONIX (Orsay Negative Ion eXtraction) has been developed. Close collaboration with experiments and other numerical models allows performing realistic simulations with relevant input parameters: plasma properties, geometry of the extraction aperture, full 3D magnetic field map, etc. For the first time ONIX has been benchmarked with commercial positive ions tracing code KOBRA3D. A very good agreement in terms of the meniscus position and depth has been found. Simulation of NI extraction with different e/NI ratio in bulk plasma shows high relevance of the direct negative ion extraction from the surface produced NI in order to obtain extracted NI current as in the experimental results from BATMAN testbed.

13.
Rev Sci Instrum ; 85(2): 02B305, 2014 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-24593582

RESUMO

An important step in the European R&D roadmap towards the neutral beam heating systems of ITER is the new test facility ELISE (Extraction from a Large Ion Source Experiment) for large-scale extraction from a half-size ITER RF source. The test facility was constructed in the last years at Max-Planck-Institut für Plasmaphysik Garching and is now operational. ELISE is gaining early experience of the performance and operation of large RF-driven negative hydrogen ion sources with plasma illumination of a source area of 1 × 0.9 m(2) and an extraction area of 0.1 m(2) using 640 apertures. First results in volume operation, i.e., without caesium seeding, are presented.

14.
Rev Sci Instrum ; 84(11): 113502, 2013 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-24295435

RESUMO

A novel fast-ion D-alpha (FIDA) diagnostic that is based on charge exchange spectroscopy has been installed at ASDEX Upgrade. The diagnostic uses a newly developed high-photon-throughput spectrometer together with a low-noise EM-CCD camera that allow measurements with 2 ms exposure time. Absolute intensities are obtained by calibrating the system with an integrating sphere and the wavelength dependence is determined to high accuracy using a neon lamp. Additional perturbative contributions to the spectra, such as D2-molecular lines, the Stark broadened edge D-alpha emission, and passive FIDA radiation have been identified and can be subtracted or avoided experimentally. The FIDA radiation from fast deuterium ions after charge exchange reactions can therefore be analyzed continuously without superimposed line emissions at large Doppler shifts. Radial information on the fast ions is obtained from radially distributed lines of sight. The investigation of the fast-ion velocity distribution is possible due to three different viewing geometries. The independent viewing geometries access distinct parts of the fast-ion velocity space and make tomographic reconstructions possible.

15.
Rev Sci Instrum ; 84(9): 093102, 2013 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-24089811

RESUMO

One of the main topics to be investigated at the recently launched large (A(source) = 1.0 × 0.9 m(2)) ITER relevant RF driven negative ion test facility ELISE (Extraction from a Large Ion Source Experiment) is the connection between the homogeneity of the plasma parameters close to the extraction system and the homogeneity of the extracted negative hydrogen ion beam. While several diagnostics techniques are available for measuring the beam homogeneity, the plasma parameters are determined by optical emission spectroscopy (OES) solely. First OES measurements close to the extraction system show that without magnetic filter field the vertical profile of the plasma emission is more or less symmetric, with maxima of the emission representing the projection of the plasma generation volumes, and a distinct minimum in between. The profile changes with the strength of the magnetic filter field but under all circumstances the plasma emission in ELISE is much more homogeneous compared to the smaller IPP prototype sources. Planned after this successful demonstration of the ELISE OES system is to combine OES with tomography in order to determine locally resolved values for the plasma parameters.

16.
Rev Sci Instrum ; 83(2): 02A729, 2012 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-22380238

RESUMO

CERN's superconducting proton Linac (SPL) study investigates a 50 Hz high-energy, high-power Linac for H(-) ions. The SPL plasma generator is an evolution of the DESY ion source plasma generator currently operated at CERN's Linac4 test stand. The plasma generator is a step towards a particle source for the SPL, it is designed to handle 100 kW peak RF-power at a 6% duty factor. While the acquisition of an integrated hydrogen plasma optical spectrum is straightforward, the measurement of a time-resolved spectrum requires dedicated amplification schemes. The experimental setup for visible light based on photomultipliers and narrow bandwidth filters and the UV spectrometer setup are described. The H(α), H(ß), and H(γ) Balmer line intensities, the Lyman band and alpha transition were measured. A parametric study of the optical emission from the Linac4 ion source and the SPL plasma generator as a function of RF-power and gas pressure is presented. The potential of optical emission spectrometry coupled to RF-power coupling measurements for on-line monitoring of short RF heated hydrogen plasma pulses is discussed.

17.
Rev Sci Instrum ; 83(2): 02B104, 2012 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-22380261

RESUMO

Large and powerful negative hydrogen ion sources are required for the neutral beam injection (NBI) systems of future fusion devices. Simplicity and maintenance-free operation favors RF sources, which are developed intensively at the Max-Planck-Institut für Plasmaphysik (IPP) since many years. The negative hydrogen ions are generated by caesium-enhanced surface conversion of atoms and positive ions on the plasma grid surface. With a small scale prototype the required high ion current density and the low fraction of co-extracted electrons at low pressure as well as stable pulses up to 1 h could be demonstrated. The modular design allows extension to large source dimensions. This has led to the decision to choose RF sources for the NBI of the international fusion reactor, ITER. As an intermediate step towards the full size ITER source at IPP, the development will be continued with a half-size source on the new ELISE testbed. This will enable to gain experience for the first time with negative hydrogen ion beams from RF sources of these dimensions.

18.
Rev Sci Instrum ; 81(2): 02A706, 2010 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-20192376

RESUMO

Cesium seeded sources for surface generated negative hydrogen ions are major components of neutral beam injection systems in future large-scale fusion experiments such as ITER. Stability and delivered current density depend highly on the cesium conditions during plasma-on and plasma-off phases of the ion source. The Monte Carlo code CSFLOW3D was used to study the transport of neutral and ionic cesium in both phases. Homogeneous and intense flows were obtained from two cesium sources in the expansion region of the ion source and from a dispenser array, which is located 10 cm in front of the converter surface.

19.
Rev Sci Instrum ; 79(2 Pt 2): 02A511, 2008 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-18315132

RESUMO

The international fusion experiment ITER requires for the plasma heating and current drive a neutral beam injection system based on negative hydrogen ion sources at 0.3 Pa. The ion source must deliver a current of 40 A D(-) for up to 1 h with an accelerated current density of 200 Am/(2) and a ratio of coextracted electrons to ions below 1. The extraction area is 0.2 m(2) from an aperture array with an envelope of 1.5 x 0.6 m(2). A high power rf-driven negative ion source has been successfully developed at the Max-Planck Institute for Plasma Physics (IPP) at three test facilities in parallel. Current densities of 330 and 230 Am/(2) have been achieved for hydrogen and deuterium, respectively, at a pressure of 0.3 Pa and an electron/ion ratio below 1 for a small extraction area (0.007 m(2)) and short pulses (<4 s). In the long pulse experiment, equipped with an extraction area of 0.02 m(2), the pulse length has been extended to 3600 s. A large rf source, with the width and half the height of the ITER source but without extraction system, is intended to demonstrate the size scaling and plasma homogeneity of rf ion sources. The source operates routinely now. First results on plasma homogeneity obtained from optical emission spectroscopy and Langmuir probes are very promising. Based on the success of the IPP development program, the high power rf-driven negative ion source has been chosen recently for the ITER beam systems in the ITER design review process.

20.
J Biol Chem ; 276(51): 47914-21, 2001 Dec 21.
Artigo em Inglês | MEDLINE | ID: mdl-11598106

RESUMO

The reversible inhibition of calcineurin (CaN), which is the only Ca(2+)/calmodulin-dependent protein Ser/Thr phosphatase, is thought to be a key functional event for most cyclosporin A (CsA)- and tacrolimus (FK506)-mediated biological effects. In addition to CaN inhibition, however, CsA and FK506 have multiple biochemical effects because of their action in a gain-of-function model that requires prior binding to immunophilic proteins. We screened a small molecule library for direct inhibitors of CaN using CaN-mediated dephosphorylation of (33)P-labeled 19-residue phosphopeptide substrate (RII phosphopeptide) as an assay and found the polyphenolic aldehyde gossypol to be a novel CaN inhibitor. Unlike CsA and FK506, gossypol does not require a matchmaker protein for reversible CaN inhibition with an IC(50) value of 15 microm. Gossypolone, a gossypol analog, showed improved inhibition of both RII phosphopeptide and p-nitrophenyl phosphate dephosphorylation with an IC(50) of 9 and 6 microm, respectively. In contrast, apogossypol hexaacetate was inactive. Gossypol acts noncompetitively, interfering with the binding site for the cyclophilin 18.CsA complex in CaN. In contrast to CsA and FK506, gossypol does not inactivate the peptidyl-prolyl-cis/trans-isomerase activity of immunophilins. Similar to CsA and FK506, T cell receptor signaling induced by phorbol 12-myristate 13-acetate/ionomycin is inhibited by gossypol in a dose-dependent manner, demonstrated by the inhibition of nuclear factor of activated T cell (NFAT) c1 translocation from the cytosol into the nucleus and suppression of NFAT-luciferase reporter gene activity.


Assuntos
Inibidores de Calcineurina , Inibidores Enzimáticos/farmacologia , Gossipol/farmacologia , Proteínas Nucleares , Sequência de Aminoácidos , Animais , Linfócitos T CD4-Positivos/metabolismo , Linfócitos T CD8-Positivos/metabolismo , Bovinos , Células Cultivadas , Proteínas Quinases Dependentes de AMP Cíclico/química , Proteínas de Ligação a DNA/metabolismo , Genes Reporter , Humanos , Luciferases/genética , Ativação Linfocitária , Dados de Sequência Molecular , Fatores de Transcrição NFATC , Fosforilação , Transporte Proteico , Especificidade por Substrato , Fatores de Transcrição/metabolismo
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...