Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 35
Filtrar
1.
Cardiovasc Intervent Radiol ; 45(9): 1304-1313, 2022 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-35922562

RESUMO

PURPOSE: The aim of this study was to identify positive predictors for survival in uveal melanoma (UM) patients treated with percutaneous hepatic perfusion with melphalan (M-PHP), by retrospectively pooling data from three centers. MATERIALS AND METHODS: Retrospective analysis including patients ([Formula: see text] 18 years) treated with M-PHP between February 2014 and December 2019 for unresectable liver-dominant or liver-only metastases from UM. Predictors for OS were assessed using uni- and multivariate analyses. Other study outcome measures were response rate, progression-free survival (PFS), liver progression-free survival (LPFS), overall survival (OS) and complications according to CTCAEv5.0. RESULTS: In total, 101 patients (47.5% males; median age 59.0 years) completed a minimum of one M-PHP. At a median follow-up time of 15.0 months, complete response (CR), partial response (PR), stable disease (SD) and progressive disease were seen in five (5.0%), 55 (54.5%), 30 (29.7%) and 11 (10.9%) patients, respectively, leading to a 89.1% disease control rate. Median PFS, LPFS and OS were 9.0, 11.0 and 20.0 months, respectively. Survival analyses stratified for radiological response demonstrated significant improved survival in patients with CR or PR and SD category. Treatment of the primary tumor with radiotherapy, ≥ 2 M-PHP and lactate dehydrogenase (LDH) < 248 U/L were correlated with improved OS. Thirty-day mortality was 1.1% (n = 2). Most common complication was hematological toxicity (self-limiting in most cases). CONCLUSION: M-PHP is safe and effective in patients with UM liver metastases. Achieving CR, PR or SD is associated with improved survival. Primary tumor treatment with radiotherapy, normal baseline LDH and > 1 M-PHP cycles are associated with improved OS.


Assuntos
Neoplasias Hepáticas , Neoplasias Uveais , Antineoplásicos Alquilantes/uso terapêutico , Quimioterapia do Câncer por Perfusão Regional , Feminino , Humanos , Neoplasias Hepáticas/tratamento farmacológico , Masculino , Melanoma , Melfalan/uso terapêutico , Pessoa de Meia-Idade , Perfusão , Estudos Retrospectivos , Neoplasias Uveais/tratamento farmacológico
2.
Cardiovasc Intervent Radiol ; 45(5): 696-702, 2022 May.
Artigo em Inglês | MEDLINE | ID: mdl-35018502

RESUMO

PURPOSE: To assess the feasibility, safety and effectiveness of portal vein recanalization (PVR)-transjugular portosystemic shunt (TIPS) placement via splenic access using a balloon puncture technique. MATERIALS AND METHODS: In a single-center retrospective study from March 2017 to February 2021, 14 consecutive patients with portal hypertension, chronic liver disease and portal vein occlusion or near-complete (> 95%) occlusion were referred for PVR-TIPS placement. Feasibility, safety and effectiveness including procedural characteristics such as technical success, complication profile and splenic access time (SAT), balloon positioning time (BPT), conventional portal vein entry time (CPVET), overall procedure time (OPT), fluoroscopy time (FT), dose-area product (DAP) and air kerma (AK) were evaluated. RESULTS: Transsplenic PVR-TIPS using balloon puncture technique was technically feasible in 12 of 14 patients (8 men, 49 ± 13 years). In two patients without detectable intrahepatic portal vein branches, TIPS placement was not feasible and both patients were referred for further treatment with nonselective beta blockers and endoscopic variceal ligation. No complications grade > 3 of the Cardiovascular and Interventional Radiological Society of Europe classification system occurred. The SAT was 25 ± 21 min, CPVET was 33 ± 26 min, the OPT was 158 ± 54 min, the FT was 42 ± 22 min, the DAP was 167.84 ± 129.23 Gy*cm2 and the AK was 1150.70 ± 910.73 mGy. CONCLUSIONS: Transsplenic PVR-TIPS using a balloon puncture technique is feasible and appears to be safe in our series of patients with obliteration of the portal vein. It expands the interventional options in patients with chronic PVT.


Assuntos
Hipertensão Portal , Derivação Portossistêmica Transjugular Intra-Hepática , Estudos de Viabilidade , Feminino , Humanos , Hipertensão Portal/etiologia , Hipertensão Portal/cirurgia , Masculino , Veia Porta/cirurgia , Derivação Portossistêmica Transjugular Intra-Hepática/métodos , Estudos Retrospectivos , Resultado do Tratamento
3.
Clin Exp Metastasis ; 37(6): 683-692, 2020 12.
Artigo em Inglês | MEDLINE | ID: mdl-33034815

RESUMO

To evaluate feasibility, frequency and severity of peri-procedural complications and post-procedural adverse events (AEs) in patients with advanced cholangiocarcinoma or liver metastasis of uveal melanoma and prior hemihepatectomy undergoing chemosaturation percutaneous hepatic perfusion (CS-PHP) and to analyze therapy response and overall survival compared to a matched group without prior surgery. CS-PHP performed between 10/2014 and 02/2018 were retrospectively assessed. To determine peri-procedural safety and post-procedural adverse events, hospital records and hematological, hepatic and biliary function were categorized using Common Terminology Criteria for Adverse Events (CTCAE) v5.0 (1-5; mild-death). Significance was tested using Wilcoxon signed-rank and Mann-Whitney U test. Kaplan-Meier estimation and log-rank test assessed survival. Overall 21 CS-PHP in seven patients (4/7 males; 52 ± 10 years) with hemihepatectomy (grouphemihep) and 22 CS-PHP in seven patients (3/7 males; 63 ± 12 years) without prior surgery (groupnoresection) were included. No complications occurred during the CS-PHP procedures. Transient changes (CTCAE grade 1-2) of liver enzymes and blood cells followed all procedures. In comparison, grouphemihep presented slightly more AEs grade 3-4 (e.g. thrombocytopenia in 57% (12/21) vs. 41% (9/22; p = 0.37)) 5-7 days after CS-PHP. These AEs were self-limiting or responsive to treatment (insignificant difference of pre-interventional to 21-45 days post-interventional values (p > 0.05)). One patient in grouphemihep with high tumor burden died eight days following CS-PHP. No deaths occurred in groupnoresection. In comparison, overall survival after first diagnosis was insignificantly shorter in groupnoresection (44.7(32-56.1) months) than in grouphemihep (48.3(34.6-72.8) months; p = 0.48). The severity of adverse events following CS-PHP in patients after hemihepatectomy was comparable to a matched group without prior liver surgery. Thus, the performance of CS-PHP is not substantially compromised by a prior hemihepatectomy.


Assuntos
Neoplasias dos Ductos Biliares/tratamento farmacológico , Quimioterapia do Câncer por Perfusão Regional/métodos , Colangiocarcinoma/tratamento farmacológico , Neoplasias Hepáticas/tratamento farmacológico , Neoplasias Hepáticas/cirurgia , Melanoma/tratamento farmacológico , Melfalan/administração & dosagem , Neoplasias Uveais/tratamento farmacológico , Antineoplásicos Alquilantes/administração & dosagem , Antineoplásicos Alquilantes/efeitos adversos , Neoplasias dos Ductos Biliares/secundário , Quimioterapia do Câncer por Perfusão Regional/efeitos adversos , Colangiocarcinoma/secundário , Terapia Combinada , Feminino , Hepatectomia/efeitos adversos , Hepatectomia/métodos , Humanos , Neoplasias Hepáticas/secundário , Masculino , Melanoma/patologia , Melfalan/efeitos adversos , Pessoa de Meia-Idade , Estudos Retrospectivos , Taxa de Sobrevida , Neoplasias Uveais/patologia
4.
Internist (Berl) ; 61(2): 158-163, 2020 Feb.
Artigo em Alemão | MEDLINE | ID: mdl-31919532

RESUMO

Interventional radiology offers a large variety of locoregional and local ablative treatment options for liver tumors. These can be applied as stand-alone minimally invasive procedures or in combination with other treatment options and with curative as well as palliative intent depending on the respective tumor stage. This review article presents the various locoregional and local ablative treatment techniques and describes the clinical value in the treatment of hepatocellular carcinoma and intrahepatic cholangiocarcinoma.


Assuntos
Neoplasias dos Ductos Biliares , Carcinoma Hepatocelular , Colangiocarcinoma , Neoplasias Hepáticas , Neoplasias dos Ductos Biliares/terapia , Ductos Biliares Intra-Hepáticos , Carcinoma Hepatocelular/terapia , Ablação por Cateter , Colangiocarcinoma/terapia , Humanos , Neoplasias Hepáticas/terapia
5.
Clin Radiol ; 74(6): 437-444, 2019 06.
Artigo em Inglês | MEDLINE | ID: mdl-30890260

RESUMO

AIM: To evaluate the feasibility of two-dimensional parametric parenchymal blood flow (2D-PPBF) to quantify perfusion changes in the lung parenchyma following balloon pulmonary angioplasty (BPA) for treatment of chronic thromboembolic pulmonary hypertension. MATERIALS AND METHODS: Overall, 35 consecutive interventions in 18 patients with 98 treated pulmonary arteries were included. To quantify changes in pulmonary blood flow using 2D-PPBF, the acquired digital subtraction angiography (DSA) series were post-processed using dedicated software. A reference region of interest (ROI; arterial inflow) in the treated pulmonary artery and a distal target ROI, including the whole lung parenchyma distal to the targeted stenosis, were placed in corresponding areas on DSA pre- and post-BPA. Half-peak density (HPD), wash-in rate (WIR), arrival to peak (AP), area under the curve (AUC), and mean transit time (MTT) were assessed. The ratios of the reference ROI to the target ROI (HPDparenchyma/HPDinflow, WIRparenchyma/WIRinflow; APparenchyma/APinflow, AUCparenchyma/AUCinflow, MTTparenchyma/MTTinflow) were calculated. The relative differences of the 2D-PPBF parameters were correlated to changes in the pulmonary flow grade score. RESULTS: The pulmonary flow grade score improved significantly after BPA (1 versus 3; p<0.0001). Likewise, the mean HPDparenchyma/HPDinflow (-10.2%; p<0.0001), APparenchyma/APinflow (-24.4%; p=0.0007), and MTTparenchyma/MTTinflow (-3.5%; p=0.0449) decreased significantly, whereas WIRparenchyma/WIRinflow (+82.4%) and AUCparenchyma/AUCinflow (+58.6%) showed a significant increase (p<0.0001). Furthermore, a significant correlation between changes of the pulmonary flow grade score and changes of HPDparenchyma/HPDinflow (ρ=-0.21, p=0.04), WIRparenchyma/WIRinflow (ρ=0.43, p<0.0001), APparenchyma/APinflow (ρ=-0.22, p=0.03), AUCparenchyma/AUCinflow (ρ=0.48, p<0.0001), and MTTparenchyma/MTTinflow (ρ=-0.39, p<0.0001) could be observed. CONCLUSION: The 2D-PPBF technique is feasible for the quantification of perfusion changes following BPA and has the potential to improve monitoring of BPA.


Assuntos
Angiografia Digital/métodos , Angioplastia com Balão/métodos , Hipertensão Pulmonar/diagnóstico por imagem , Hipertensão Pulmonar/terapia , Interpretação de Imagem Assistida por Computador/métodos , Idoso , Algoritmos , Doença Crônica , Estudos de Viabilidade , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Artéria Pulmonar/diagnóstico por imagem , Estudos Retrospectivos
6.
Eur Radiol ; 29(6): 3233-3240, 2019 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-30552480

RESUMO

OBJECTIVES: The objective of this study was to compare the diagnostic performance of direct C-arm flat panel computed tomography arthrography (FPCT-A) with direct magnetic resonance arthrography (MR-A) of the wrist in patients with clinically suspected pathologies. METHODS: Forty-nine patients underwent tri-compartmental wrist arthrography. FPCT-A was acquired using a high-resolution acquisition mode, followed by a 3-T MR exam using a dedicated wrist coil. Image quality and artifacts of FPCT-A and MR-A were evaluated with regard to the depictability of anatomical structures. The time stamps for the different image acquisitions were recorded for workflow assessment. RESULTS: Image quality was rated significantly superior for all structures for FPCT-A (p < 0.001) as compared to MR-A including intrinsic ligaments, TFCC, cartilage, subchondral bone, and trabeculae. The differences in image quality were highest for cartilage (2.0) and lowest for TFCC (0.9). The artifacts were rated lower in MR-A than in FPCT-A (p < 0.001). The procedure was more time-efficient in FPCT-A than in MR-A. CONCLUSIONS: FPCT-A of the wrist provides superior image quality and optimized workflow as compared to MR-A. Therefore, FPCT-A should be considered in patients scheduled for dedicated imaging of the intrinsic structures of the wrist. KEY POINTS: • FPCT arthrography allows high-resolution imaging of the intrinsic wrist structures. • The image quality is superior as compared to MR arthrography. • The procedure is more time-efficient than MR arthrography.


Assuntos
Artrografia/métodos , Imageamento por Ressonância Magnética , Tomografia Computadorizada por Raios X , Punho/diagnóstico por imagem , Adolescente , Adulto , Idoso , Artralgia/diagnóstico por imagem , Artefatos , Cartilagem Articular/diagnóstico por imagem , Feminino , Ossos da Mão/diagnóstico por imagem , Humanos , Ligamentos/diagnóstico por imagem , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Sensibilidade e Especificidade , Traumatismos do Punho/diagnóstico , Adulto Jovem
7.
Eur J Radiol ; 101: 149-156, 2018 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-29571789

RESUMO

PURPOSE: Virtual single source computed tomography (VSS-CT) acquisition on a dual source CT (DSCT) has been demonstrated to allow for dose-neutral intra-individual comparison of three acquisition protocols at different radiation dose levels (RDL) within one acquisition in a phantom. The purpose of this study was twofold: first to evaluate the applicability of VSS-CT in patients and second to optimize the task-dependent trade-off between radiation dose and image quality of lower extremity CT angiography (run-off CTA). MATERIAL AND METHODS: In this IRB-approved prospective study 52 patients underwent run-off CTA between 06/2012 and 06/2013. VSS-CT acquisition was conducted using a first generation DSCT applying equal X-ray tube settings (120 kVp), collimation (2 × 32 × 0.6 mm), and slice thickness (1.0 mm) but different effective tube current-time products (tube A: 80 mAs, tube B: 40 mAs). Three different image datasets representing three different radiation dose levels (RDL40, RDL80, RDL120) were reconstructed using a soft kernel from the raw data of tube B, tube A or both tubes combined. Dose length products (DLP) of each raw data set were documented. Quantitative image quality (IQ) was assessed for five anatomical levels using image noise and contrast-to-noise ratio (CNR). To investigate dose efficiency of each acquisition, the dose-weighted CNR (CNRD) was determined. Qualitative IQ was evaluated by two blinded readers in consensus using a 5-point Likert scale and compared with a Friedman- and posthoc Wilcoxon test. RESULTS: Mean DLP was 200 ±â€¯40, 400 ±â€¯90 and 600 ±â€¯130 mGy·cm for the RDL40, RDL80 and RDL120, respectively. Image noise and CNR were best for RDL120 and decreased significantly for RDL80 and RDL40, independent of the anatomic level (p < 0.001). CNRD showed no significant differences at the abdominal and pelvic level between the investigated radiation dose levels. However, for thigh to foot level a significant increase of CNRD was noted between RDL120, RDL80 and RDL40. Significant differences of qualitative IQ were observed between RDL120 and RDL40 from the abdominal to the foot level, whereas no difference was seen for the other dose levels. CONCLUSION: Radiation dose splitting with VSS-CT can be applied to run-off CTA facilitating intra-individual comparison of different acquisition protocols without additional radiation exposure. Furthermore, a radiation dose reduction potential for run-off CTA of approximately 1/3 as compared to the acquisition protocol recommended by the manufacturer could be identified in this study.


Assuntos
Doses de Radiação , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Tomografia Computadorizada por Raios X/métodos , Idoso , Angiografia por Tomografia Computadorizada/métodos , Feminino , Humanos , Masculino , Estudos Prospectivos
8.
Rofo ; 187(4): 260-8, 2015 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-25816060

RESUMO

PURPOSE: To survey integrative teaching in radiology at German universities. MATERIALS AND METHODS: A questionnaire about radiological education was sent electronically to all 37 chairpersons of university radiology departments in Germany. The questions included the course type, teaching methods, concept, perception, and advantages and disadvantages of integrative teaching. Statistical analysis was performed with nonparametric statistics and chi-square test. RESULTS: The survey was considered representative with a return rate of 68 %. Integrative teaching is established at 4/5 of all departments. Integrative teaching is well accepted with an acceptance rate that is significantly higher in so-called "Modellstudiengängen" [model courses of study] (100 %) compared to conventional courses of study (72 %). The advantages of integrative teaching include linking of content (92 %) and preparation for interdisciplinary work (76 %). The disadvantages include high effort (75 %) and time (67 %) for organization. Furthermore, there is a risk that basic radiological facts and knowledge cannot be conveyed and that the visibility of radiology as an independent discipline is lost. Conventional radiological teaching has a similarly high acceptance (84 %) compared to integrative courses (76 %). CONCLUSION: Integrative teaching has a high acceptance among chairpersons in radiology in Germany despite the greater effort. A good interdisciplinary collaboration is essential for integrative teaching and at the same time this can be conveyed to the students. However, the visibility of radiology as a discipline and the possibility to cover basic radiological content must be ensured. Therefore, both conventional courses and integrative teaching seems reasonable, especially in cross-disciplinary subjects such as radiology. KEY POINTS: Both integrative teaching and conventional radiological teaching are highly accepted. The advantages include the linking of multidisciplinary content and the preparation for interdisciplinary cooperation. The disadvantages include more time and effort for organization and reduced visibility of cross-disciplinary subjects.


Assuntos
Atitude do Pessoal de Saúde , Comportamento Cooperativo , Educação Médica/tendências , Docentes de Medicina , Comunicação Interdisciplinar , Radiologia/educação , Instrução por Computador/tendências , Currículo/tendências , Coleta de Dados , Previsões , Alemanha , Humanos , Modelos Educacionais , Faculdades de Medicina/tendências , Inquéritos e Questionários
9.
Rofo ; 186(3): 247-52, 2014 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-23999779

RESUMO

PURPOSE: To assess the benefit of C-arm CT for classification and procedural guidance during interventional therapy of endoleaks (EL) after endovascular repair (EVAR) of abdominal aortic aneurysms (AAA). MATERIALS AND METHODS: 12 patients with EL diagnosed with CT but undetermined EL classification (ELC) underwent DSA and transarterial contrast-enhanced C-arm CT. ELC (based on DSA, C-arm CT and CT) assessed during the angiographic procedure served as the standard of reference (SOR). Subsequently, ELC was assessed by a blinded second reader based on DSA or C-arm CT and compared to the SOR. In the case of an interventional procedure (n = 6), the added value of C-arm CT for procedure guidance was assessed retrospectively (1: essential, 2: helpful, 3: additional information without impact, 4: no additional information). RESULTS: The blinded reader classified 9/12 EL using DSA alone and 11/12 EL using C-arm CT alone. In one patient, the temporal resolution provided by DSA was essential to establish the diagnosis. In 6 patients, a type 2 EL without need for therapy was diagnosed. The remaining 6 patients showed EL that were treated immediately (type 1 EL, n = 4: 3 stent graft extensions and one angioplasty; type 2 EL, n = 1: translumbar embolization; type 3 EL, n = 1: sealing of a fabric tear). The information provided by C-arm CT was assessed to be essential in three patients and helpful in two. CONCLUSION: C-arm CT is an ideal adjunct to DSA. In our pilot study, it helped to localize and classify endoleaks more reliably than DSA alone.


Assuntos
Angiografia Digital/métodos , Aneurisma da Aorta Abdominal/diagnóstico por imagem , Aneurisma da Aorta Abdominal/cirurgia , Endoleak/diagnóstico por imagem , Endoleak/etiologia , Procedimentos Endovasculares/efeitos adversos , Tomografia Computadorizada por Raios X/métodos , Aneurisma da Aorta Abdominal/complicações , Humanos , Imagem Multimodal/métodos , Variações Dependentes do Observador , Intensificação de Imagem Radiográfica/métodos , Radiografia Abdominal/métodos , Estudos Retrospectivos , Cirurgia Assistida por Computador/métodos , Resultado do Tratamento
10.
Rofo ; 185(11): 1063-9, 2013 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-23893749

RESUMO

PURPOSE: Evaluation of the potential usability of an iPad 3 with a high-resolution display in CT emergency diagnosis compared to a 3 D PACS workstation. MATERIALS AND METHODS: 3 readers used a 5-point Likert scale to evaluate 40 CCT scans and 40 CTPA scans to determine the detectability of early signs of infarction in CCT or segmental and subsegmental pulmonary embolisms in CT angiography of the pulmonary arteries (CTPA) on the iPad 3 (Apple Inc., USA) using an application for image viewing (Visage Ease, Visage Imaging GmbH, Berlin) and on a 3 D PACS workstation (Visage 7.1, Visage Imaging, Berlin) using a certified monitor for image viewing. The results were compared using the Wilcoxon rank sum test, Spearman's correlation coefficient, and a kappa statistic. RESULTS: There was no significant difference in the median evaluations for the readings of both the CCT scans and the CTPA scans on the iPad 3 and on the workstation (p > 0.05) for all three readers. The mean Spearman's correlation coefficient for CCT and CTPA was 0.46 (± 0.2) and 0.69 (± 0.16), respectively, for the comparison iPad/PACS, 0.41 (± 0.16) and 0.68 (± 0.06), respectively, for the interobserver agreement on the iPad, and 0.35 (± 0.05) and 0.68 (± 0.10), respectively, for the interobserver agreement on the PACS. Mean kappa values for CCT of 0.52 (± 0.17) for the comparison iPad/PACS and 0.33 (± 0.16) and 0.32 (± 0.16), respectively, for the interobserver agreement on the iPad and the PACS were achieved. For CTPA average kappa values of 0.67 (± 0.19) were calculated for the comparison iPad/PACS and 0.69 (± 0.08) and 0.60 (± 0.14), respectively, for the interobserver concordance on the iPad 3 and the PACS. All differences were not statistically significant (p > 0.05). CONCLUSION: The variability of the interpretation of typical emergency scans on an iPad 3 with a high-resolution display and on a 3 D PACS workstation does not differ from the interobserver variability.


Assuntos
Infarto Cerebral/diagnóstico por imagem , Computadores de Mão , Serviços Médicos de Emergência/métodos , Aplicativos Móveis , Embolia Pulmonar/diagnóstico por imagem , Interpretação de Imagem Radiográfica Assistida por Computador/instrumentação , Tomografia Computadorizada por Raios X/instrumentação , Adulto , Idoso , Idoso de 80 Anos ou mais , Terminais de Computador , Desenho de Equipamento , Análise de Falha de Equipamento , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Variações Dependentes do Observador , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Interface Usuário-Computador
11.
Rofo ; 185(9): 838-43, 2013 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-23888474

RESUMO

PURPOSE: Evaluation and analysis of the integrative course "Radiological Anatomy" established since 2007 at the Medical School Hannover (MHH) in comparison with conventional education. MATERIALS AND METHODS: Anatomy and radiology are usually taught separately with a considerable time lag. Interdisciplinary teaching of these associated subjects seems logical for several reasons. Therefore, the integrative course "Radiological Anatomy" was established in the second year of medical education, combining these two closely related subjects. This interdisciplinary course was retrospectively evaluated by consideration of a student questionnaire and staff observations. The advantages and disadvantages of integrative teaching in medical education are discussed. RESULTS: The course ratings were excellent (median 1; mean 1.3 on a scale of 1 to 6). This is significantly (p < 0.001) better than the average of all evaluated courses in the respective term (grade 2.8). The course improved the anatomical comprehension (90 %) and the students stated that the topics were relevant for their future medical education (90 %). Furthermore, interest in the subject's anatomy and radiology increased during the course (88 %). According to the students' suggestions the course was enhanced by a visitation in the Department of Radiology and the additional topic central nervous system. CONCLUSION: Integrative teaching of anatomy and radiology was well received by the students. Both, anatomical and radiological comprehension and the motivation to learn were improved. However, it should be considered, that the amount of work and time required by the teaching staff is considerably increased compared to traditional teaching.


Assuntos
Anatomia/educação , Educação Médica/métodos , Radiologia/educação , Atitude do Pessoal de Saúde , Competência Clínica , Currículo , Avaliação Educacional , Humanos , Radiografia , Radiografia Torácica , Inquéritos e Questionários , Tomografia Computadorizada por Raios X
12.
Rofo ; 185(6): 558-62, 2013 Jun.
Artigo em Alemão | MEDLINE | ID: mdl-23695984

RESUMO

PURPOSE: Smartphone apps for measuring ionizing radiation use the capability of (CMOS) camera chips to detect not only perceivable light but also electromagnetic wave radiation. The present study evaluates the accuracy of hardware and software and defines possible applications for the detection of X-ray radiation fields. MATERIALS AND METHODS: 2 apps and 2 different devices were tested in comparison with a calibrated ionization chamber and a personal electronic dosimeter. A calibration curve was determined for dose rates between 12 700 µSv/h and 5.7 µSv/h generated by a C-arm system. RESULTS: The measured scattered radiation produced by an Alderson-Rando phantom ranged from 117 µSv/h (at a distance of 2 m) to 5910 µSv/h (at a distance of 0.3 m) and was 1.4 times less than the values of the ionization chamber. The exposure rate for the operator's thyroid was within 4200 - 4400 µSv/h. We found a strong dependence of the measurements on the angulation of the Smartphone, especially for short distances from the phantom (at a distance of 0.3 m, a 45° rotation downwards in a vertical direction caused a decrease from 3000 µSv/h to 972 µSv/h, while an upwards rotation resulted in an increase to 5000 µSv/h). For a distance of 1 m, this effect was remarkably smaller. CONCLUSION: Smartphones can be used to detect ionizing radiation but showed limited accuracy and are heavily dependent on the angulation of the device. Qualitative measurements and utilization for dose alerts are possible.


Assuntos
Algoritmos , Telefone Celular , Computadores de Mão , Monitoramento de Radiação/instrumentação , Proteção Radiológica/instrumentação , Desenho de Equipamento , Análise de Falha de Equipamento , Doses de Radiação , Reprodutibilidade dos Testes , Gestão da Segurança/métodos , Sensibilidade e Especificidade
13.
Eur Radiol ; 23(9): 2482-91, 2013 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-23686291

RESUMO

OBJECTIVES: To assess the influence of different table feeds (TFs) on vascular enhancement and image quality in patients with an abdominal aortic aneurysm (AAA) undergoing computed tomography (CT) angiography of the lower extremities (run-off CTA). METHODS: Seventy-nine patients (71 ± 8 years) with an AAA (>30 mm) who underwent run-off CTA between January 2004 and August 2011 were included in this retrospective institutional review board-approved study. Run-off CTA was conducted using 16- and 64-row CT. The range of TFs was 30-86 mm/s and was categorised in quartiles TF1 (32.6 ± 1.9 mm/s), TF2 (38.9 ± 0.9 mm/s), TF3 (43.9 ± 3.1 mm/s) and TF4 (57.4 ± 10.5 mm/s). Image quality was rated independently by two radiologists and vessel enhancement was assessed. RESULTS: Image quality was diagnostic at all aortic, pelvic and almost all thigh levels. Below the knee, the number of diagnostic levels was highest for TF1 and decreased to TF4. Arterial enhancement between the aorta and fibular trunk was not different in all TF groups, P > 0.05. At the calf and foot strongest arterial enhancement was noted for TF1 and TF2 and decreased to TF4, P < 0.01. CONCLUSION: Results indicate that the highest image quality of run-off CTA in patients with an AAA may be obtained using table feeds measuring 30-35 mm/s. KEY POINTS: • CTA has become a key investigation for peripheral vascular disease. • Run-off CTA is more complex in patients with an abdominal aortic aneurysm. • Run-off CTA is feasible with a short bolus of intravenous contrast medium. • A constant 30-35 mm/s table feed provides the highest likelihood of diagnostic images.


Assuntos
Angiografia/métodos , Aneurisma da Aorta Abdominal/diagnóstico por imagem , Tomografia Computadorizada por Raios X/métodos , Idoso , Idoso de 80 Anos ou mais , Algoritmos , Aorta Abdominal/diagnóstico por imagem , Meios de Contraste/farmacologia , Feminino , Humanos , Processamento de Imagem Assistida por Computador/métodos , Perna (Membro)/irrigação sanguínea , Perna (Membro)/diagnóstico por imagem , Masculino , Pessoa de Meia-Idade , Doenças Vasculares Periféricas/diagnóstico , Doenças Vasculares Periféricas/diagnóstico por imagem , Estudos Retrospectivos , Fatores de Tempo
14.
Rofo ; 184(12): 1110-7, 2012 Dec.
Artigo em Alemão | MEDLINE | ID: mdl-22893490

RESUMO

Radiology departments at hospitals are closely watched for their economy. The introduction of fast scanner technology usually triggers questions about simultaneously reducing final report times. The aim of the present study was first to examine, if the multi-moment analysis (MMH) is an appropriate method for structural and quantitative analysis of complex work flows in Radiology, and second, if factors negatively influencing the core processes can be quantitatively evaluated. The study was performed in the Departments of Radiology and Neuroradiology at a major University Hospital in Northern Germany. Randomized monitoring of the workflow of more than 80 doctors and radiology technicians assistants resulted in 800 observations per workplace. The high observation rate yielded a high accuracy (95% confidence interval width of less than +3,5%) to determine the proportion of different work patterns. MMH proved to be an appropriate means to analyze and quantify complex work flows at a university radiology centre. Different workplaces could be compared and total daily labor time could be derived from the observations. Circadian variabilities could be differentiated. The potential of the MMH to guide workflow optimization was identified. On the basis of data collected, MMH restructuring and control systems can be planned.


Assuntos
Diagnóstico por Imagem/normas , Eficiência Organizacional/normas , Serviço Hospitalar de Radiologia/organização & administração , Fluxo de Trabalho , Alemanha , Hospitais Universitários/organização & administração , Humanos , Sistemas de Informação em Radiologia/organização & administração , Estudos de Tempo e Movimento
15.
Rofo ; 184(6): 527-34, 2012 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-22473508

RESUMO

PURPOSE: To prospectively compare a compact bolus (CB) injection protocol using high-iodine concentration contrast medium with a standard bolus (SB) injection protocol at equi-iodine doses for run-off computed tomographic angiography (CTA). MATERIALS AND METHODS: 64 patients with suspected peripheral arterial disease who underwent 40 or 64-slice run-off CTA were included in this IRB-approved study. Patients were randomized to undergo the CB protocol (32 patients, iomeprol 400mgI/mL, 100 mL, 4 mL/sec) or the SB protocol (32 patients, iomeprol 300mgI/mL, 134 mL, 4 mL/sec). Luminal contrast density (CD) values were measured and arterial opacification (AO) was scored (5-point scale). Cases of venous overlay or bolus overriding were documented. RESULTS: Overall arterial CD was significantly higher with the compact bolus (CB: 279 ± 57HU, SB: 234 ± 32HU, p = 0.0017). Segmental CD was significantly higher (p< 0.05) in 7 of 16 evaluated segments. Patency-based comparison revealed superior AO in vessels with relevant (50 - 99 %) stenoses (CB: 4.54 vs. SB: 4.18, p = 0.04). Contrast bolus overriding without pathological reasons, i. e., acute occlusions, was noted in one patient in each group. Venous overlay was observed less frequently in the CB group (CB vs. SB: 12 vs. 19 patients, n. s.; 29 of 64 legs [45 %] vs. 44 of 64 legs [69 %], p = 0.01). CONCLUSION: At equi-iodine doses, the CB protocol led to a quantitatively and qualitatively higher arterial opacification compared to the SB protocol. Therefore, a CB protocol should be favored for run-off CTA.


Assuntos
Meios de Contraste/administração & dosagem , Iopamidol/análogos & derivados , Perna (Membro)/irrigação sanguínea , Tomografia Computadorizada Multidetectores/métodos , Doença Arterial Periférica/diagnóstico por imagem , Idoso , Relação Dose-Resposta a Droga , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Grau de Desobstrução Vascular/fisiologia
16.
Rofo ; 184(1): 37-41, 2012 Jan.
Artigo em Alemão | MEDLINE | ID: mdl-22161235

RESUMO

PURPOSE: To assess patient movement on a vacuum mattress compared to a standard viscoelastic mattress during interventional procedures using an electromagnetic tracking device. MATERIALS AND METHODS: In 17 consecutive patients who underwent a diagnostic or interventional procedure, the patient was positioned using a vacuum mattress (VL, n = 9) or a standard viscoelastic mattress (SL, n = 8). The patient position was recorded continuously after the start of the procedure (S) using an electromagnetic navigation device. After the intervention (E), patients were asked to lift up the upper part of the body and to lie down again (repositioning maneuver, P). Based on the recorded patient positions, the patient movement (PM) at rest ΔP(SE), PM due to the repositioning maneuver ΔP(EP), total PM ΔP(SP) and maximum PM during the intervention ΔPMax(SE) were calculated. RESULTS: Using VL, PM at rest (ΔP[SE]: VL: 4.3 ± 2.8 mm, SL: 17.1 ± 15.7 mm; p = 0.036) and total PM (ΔP[SP]: VL: 4.6 mm ± 2.5 ± mm, SL: 27.8 ± 19.6 mm; p = 0.002) were significantly smaller. In contrast, the maximum PM as a parameter for the mobility of the patient (ΔPMax(SE): VL: 14.2 ± 15.1 mm, SL: 17.6 ± 13.4 mm; p = 0.48) and the PM due to the repositioning maneuver (ΔP[EP]: VL: 4.4 ± 2.5 mm, SL: 15.7 mm ± 15.9 mm, p = 0.32) were similar. CONCLUSION: Patient positioning on a vacuum mattress is fast, easy, comfortable for the patient and reduces relevant patient movements. Therefore, vacuum mattress positioning can be used for image-guided interventions relying on preprocedural imaging data, where minimal patient movement is a prerequisite.


Assuntos
Angiografia Digital/instrumentação , Angioplastia/instrumentação , Artefatos , Leitos , Quimioembolização Terapêutica/instrumentação , Processamento de Imagem Assistida por Computador/instrumentação , Imageamento Tridimensional/instrumentação , Imobilização/instrumentação , Atividade Motora , Posicionamento do Paciente/instrumentação , Radiologia Intervencionista/instrumentação , Tomografia Computadorizada por Raios X/instrumentação , Idoso , Fenômenos Eletromagnéticos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Imagens de Fantasmas , Punções/instrumentação , Estudos de Tempo e Movimento
17.
Radiologe ; 49(9): 856-61, 2009 Sep.
Artigo em Alemão | MEDLINE | ID: mdl-19730807

RESUMO

Flat-detector CT coupled to an angiography device provides an imaging technique for interventions which can be used for electromagnetically navigated percutaneous punctures. This report explains the functionality of an electromagnetic navigation system and describes the course of an electromagnetically navigated puncture and the capabilities of such a system in the clinical routine.


Assuntos
Imageamento Tridimensional/instrumentação , Magnetismo/instrumentação , Punções/instrumentação , Radiografia Intervencionista/instrumentação , Cirurgia Assistida por Computador/métodos , Tomografia Computadorizada por Raios X/métodos , Transdutores , Desenho de Equipamento , Análise de Falha de Equipamento , Avaliação da Tecnologia Biomédica
18.
Radiologe ; 49(9): 848-51, 2009 Sep.
Artigo em Alemão | MEDLINE | ID: mdl-19697002

RESUMO

Primary hyperaldosteronism is the most common curable cause of hypertension with a prevalence of up to 12% among patients with hypertension. Selective blood sampling from adrenal veins is considered the diagnostic gold standard. However, it is underutilized due to the high technical failure rate. The use of C-arm CT during the sampling procedure can reduce or even eliminate this failure rate. If adrenal vein sampling is augmented by native C-arm CT to check for the correct catheter position, the technical success rate increases substantially. General use of this technique will result in correct diagnosis and treatment for patients with primary hyperaldosteronism.


Assuntos
Glândulas Suprarrenais/irrigação sanguínea , Glândulas Suprarrenais/diagnóstico por imagem , Aldosterona/sangue , Hiperaldosteronismo/sangue , Hiperaldosteronismo/diagnóstico por imagem , Flebografia/métodos , Punções/métodos , Tomografia Computadorizada por Raios X/métodos , Análise Química do Sangue/métodos , Feminino , Humanos , Hiperaldosteronismo/diagnóstico , Masculino , Pessoa de Meia-Idade , Radiografia Intervencionista/métodos
19.
Radiologe ; 49(9): 842-7, 2009 Sep.
Artigo em Alemão | MEDLINE | ID: mdl-19697003

RESUMO

Interventional radiological vascular embolizations are complex procedures that require exact imaging of the target region to facilitate safe and effective treatment. The purpose of this paper is to present the technique and feasibility of flat detector C-arm computed tomography (C-arm CT) for control and guidance of extrahepatic abdominal embolization procedures. C-arm CT images can provide important information on both vascular and cross-sectional anatomy of the target region, help in determining therapy endpoints and provide follow-up during and immediately after the abdominal interventions.The cases presented demonstrate that C-arm CT images are beneficial for abdominal embolization procedures and facilitate precise treatment.


Assuntos
Neoplasias Abdominais/diagnóstico por imagem , Neoplasias Abdominais/terapia , Antineoplásicos/administração & dosagem , Quimioembolização Terapêutica/métodos , Radiografia Abdominal/métodos , Radiografia Intervencionista/métodos , Tomografia Computadorizada por Raios X/métodos , Idoso , Idoso de 80 Anos ou mais , Humanos , Masculino , Resultado do Tratamento
20.
Eur Radiol ; 19(9): 2302-9, 2009 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-19424701

RESUMO

The purpose of the study was to prospectively evaluate intrahepatic vessel depiction on C-arm CT (CACT) and the influence of the additional combined tissue and three-dimensional vessel visualisation on the positioning of the TACE catheter in comparison to DSA alone. Thirty consecutive patients scheduled for their first transarterial chemoembolisation underwent biphasic CACT and DSA of the liver. After assessing the DSA images for procedure planning, the CACT images were reviewed. The number and origin of the tumour-feeding arteries and the ideal position of the catheter for TACE on both DSA and CACT were assessed and correlated. The number of vessels identified as tumour feeders in each patient was significantly higher using additional CACT than on DSA alone (CACT: 4.0 +/- 1.7; DSA: 3.3 +/- 1.4; P = 0.003, t-test). After considering CACT, in 50% of the patients the catheter position was changed for TACE. Segmental portal vein thrombosis was seen in three patients on CACT, but in only one on DSA. As CACT depicts soft tissue and small vessels with high spatial resolution, tumour vessel allocation is facilitated, and ideal catheter position for TACE can be more accurately identified. The high impact of CACT on the TACE procedure suggests the benefits of its routine use for all patients undergoing their first TACE.


Assuntos
Protocolos de Quimioterapia Combinada Antineoplásica/administração & dosagem , Quimioembolização Terapêutica/métodos , Artéria Hepática/diagnóstico por imagem , Imageamento Tridimensional/métodos , Neoplasias Hepáticas/diagnóstico por imagem , Veia Porta/diagnóstico por imagem , Tomografia Computadorizada por Raios X/métodos , Adulto , Idoso , Feminino , Humanos , Neoplasias Hepáticas/irrigação sanguínea , Masculino , Pessoa de Meia-Idade , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Resultado do Tratamento , Adulto Jovem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...