1.
Europace ; 25(2): 536-545, 2023 02 16.
Artigo em Inglês | MEDLINE | ID: mdl-36480445

RESUMO

AIMS: Cardiac resynchronization therapy programmed to dynamically fuse pacing with intrinsic conduction using atrioventricular (AV) timing algorithms (e.g. SyncAV) has shown promise; however, mechanistic data are lacking. This study assessed the impact of SyncAV on electrical dyssynchrony across various pacing modalities using non-invasive epicardial electrocardiographic imaging (ECGi). METHODS AND RESULTS: Twenty-five patients with left bundle-branch block (median QRS duration (QRSd) 162.7 ms) and intact AV conduction (PR interval 174.0 ms) were prospectively enrolled. ECGi was performed acutely during biventricular pacing with fixed nominal AV delays (BiV) and using SyncAV (optimized for the narrowest QRSd) during: BiV + SyncAV, LV-only single-site (LVSS + SyncAV), MultiPoint pacing (MPP + SyncAV), and LV-only MPP (LVMPP + SyncAV). Dyssynchrony was quantified via ECGi (LV activation time, LVAT; RV activation time, RVAT; LV electrical dispersion index, LVEDi; ventricular electrical uncoupling index, VEU; and biventricular total activation time, VVtat). Intrinsic conduction LVAT (124 ms) was significantly reduced by BiV pacing (109 ms) (P = 0.001) and further reduced by LVSS + SyncAV (103 ms), BiV + SyncAV (103 ms), LVMPP + SyncAV (95 ms), and MPP + SyncAV (90 ms). Intrinsic RVAT (93 ms), VVtat (130 ms), LVEDi (36 ms), VEU (50 ms), and QRSd (163 ms) were reduced by SyncAV across all pacing modes. More patients exhibited minimal LVAT, VVtat, LVEDi, and QRSd with MPP + SyncAV than any other modality. CONCLUSION: Dynamic AV delay programming targeting fusion with intrinsic conduction significantly reduced dyssynchrony, as quantified by ECGi and QRSd for all evaluated pacing modes. MPP + SyncAV achieved the greatest synchrony overall but not for all patients, highlighting the value of pacing mode individualization during fusion optimization.


Assuntos
Terapia de Ressincronização Cardíaca , Insuficiência Cardíaca , Humanos , Bloqueio de Ramo/diagnóstico por imagem , Bloqueio de Ramo/terapia , Insuficiência Cardíaca/terapia , Terapia de Ressincronização Cardíaca/métodos , Eletrocardiografia , Dispositivos de Terapia de Ressincronização Cardíaca , Resultado do Tratamento
2.
Europace ; 24(11): 1824-1833, 2022 11 22.
Artigo em Inglês | MEDLINE | ID: mdl-35894862

RESUMO

AIMS: To determine the incidence, clinical features, management, and outcomes of pacemaker (PM) and implantable cardioverter-defibrillator (ICD) lead cardiac perforation. Cardiac perforations due to PM and ICD leads are rare but serious complications. Clinical features vary widely and may cause diagnostic delay. Management strategies are non-guideline based due to paucity of data. METHODS AND RESULTS: A multicentre retrospective series including 3 UK cardiac tertiary centres from 2016 to 2020. Patient, device, and lead characteristics were obtained including 6-month outcomes. Seventy cases of perforation were identified from 10 631 procedures; perforation rate was 0.50% for local implants. Thirty-nine (56%) patients were female, mean ( ± standard deviation) age 74 ( ± 13.8) years. Left ventricular ejection fraction 51 ( ± 13.2) %. Median time to diagnosis was 9 (range: 0-989) days. Computed tomography (CT) diagnosed perforation with 97% sensitivity. Lead parameter abnormalities were present in 86% (whole cohort) and 98.6% for perforations diagnosed >24 h. Chest pain was the commonest symptom, present in 46%. The management strategy was percutaneous in 98.6% with complete procedural success in 98.6%. Pericardial effusion with tamponade was present in 17% and was associated with significantly increased mortality and major complications. Anticoagulation status was associated with tamponade by multivariate analysis (odds ratio 21.7, 95% confidence interval: 1.7-275.5, P = 0.018). CONCLUSIONS: Perforation was rare (0.50%) and managed successfully by a percutaneous strategy with good outcomes. Tamponade was associated with increased mortality and major complications. Anticoagulation status was an independent predictor of tamponade. Case complexity is highly variable and requires skilled operators with a multi-disciplinary approach to achieve good outcomes.


Assuntos
Desfibriladores Implantáveis , Traumatismos Cardíacos , Marca-Passo Artificial , Humanos , Feminino , Idoso , Masculino , Estudos Retrospectivos , Volume Sistólico , Diagnóstico Tardio/efeitos adversos , Função Ventricular Esquerda , Marca-Passo Artificial/efeitos adversos , Traumatismos Cardíacos/diagnóstico por imagem , Traumatismos Cardíacos/etiologia , Traumatismos Cardíacos/terapia , Desfibriladores Implantáveis/efeitos adversos , Doença Iatrogênica , Anticoagulantes
3.
Europace ; 24(9): 1420-1429, 2022 10 13.
Artigo em Inglês | MEDLINE | ID: mdl-35737685

RESUMO

AIM: Evaluate the novel PolarX Cryoballoon in atrial fibrillation (AF) catheter ablation through a propensity-matched comparison with the Arctic Front Advance (AFA). The aim was also to identify cryoablation metrics that are predictive of successful pulmonary vein isolation (PVI) with the PolarX Cryoballoon. METHODS AND RESULTS: This prospective multi-centre study included patients that underwent cryoablation for AF. All patients underwent PVI with reconnection assessed after a 30-min waiting period and adenosine. Safety, efficacy, and cryoablation metrics were compared between PolarX and a propensity-matched AFA cohort. Seventy patients were included with 278 veins treated. In total, 359 cryoablations were performed (1.3 ± 0.6 per vein) to achieve initial PVI with 205 (73.7%) veins isolating with a single cryoablation. Independent predictors for achieving initial PVI included temperature at 30 s [odds ratio (OR) 1.26; P = 0.003] and time to reach -40°C (OR 1.88; P < 0.001) with an optimal cut-off of ≤-38.5°C at 30 s [area under the curve (AUC) 0.79; P < 0.001] and ≤-40°C at ≤32.5 s (AUC 0.77; P < 0.001), respectively. Of the 278 veins, 46 (16.5%) veins showed acute reconnection. Temperature at 30 s (≤-39.5°C, OR 1.24; P = 0.002), nadir temperature (≤-53.5°C, OR 1.35; P = 0.003), and time to isolation (≤38.0 s, OR 1.18; P = 0.009) were independent predictors of sustained PVI. Combining two of these three targets was associated with reconnection in only 2-5% of PVs. Efficacy and safety of the PolarX Cryoballoon were comparable to AFA Cryoballoon, however, cryoablation metrics were significantly different. CONCLUSIONS: The PolarX Cryoballoon has a different cryoablation profile to AFA Cryoballoon. Prospective testing of these proposed targets in large outcomes studies is required.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Criocirurgia , Veias Pulmonares , Adenosina , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Benchmarking , Ablação por Cateter/efeitos adversos , Ablação por Cateter/métodos , Criocirurgia/efeitos adversos , Criocirurgia/métodos , Humanos , Estudos Prospectivos , Veias Pulmonares/cirurgia , Recidiva , Fatores de Tempo , Resultado do Tratamento
4.
Heart Rhythm ; 19(6): 875-884, 2022 06.
Artigo em Inglês | MEDLINE | ID: mdl-35134548

RESUMO

BACKGROUND: Mechanisms sustaining persistent atrial fibrillation (AF) remain uncertain. OBJECTIVES: The purpose of this study was to use electrocardiographic imaging (ECGI) mapping to guide localized driver ablation in patients with persistent AF. METHODS: Patients undergoing catheter ablation for persistent AF <2 years were included. Patients were enrolled consecutively between 2018 and 2020. ECGI mapping was used to identify focal and rotational potential drivers (PDs). PDs were ablated after pulmonary vein isolation (PVI). The ablation response and freedom from AF/atrial tachycardia (AT) at 1 year were assessed. RESULTS: Forty patients were enrolled. AF terminated with PVI in 8 patients, and 32 underwent ECGI-guided driver ablation. Average procedural duration was 228.8 ± 66.7 minutes, with a total radiofrequency delivery time of 38.9 ± 14.1 minutes. During 1 year of follow-up, the primary endpoint of freedom from AF/AT was achieved in 26 patients (65%). The secondary endpoint of freedom from AF was achieved in 30 patients (75%). AF termination was achieved in 20 of 40 patients (50%). The composite endpoint of an ablation response (AF termination or cycle length slowing ≥10%) occurred in 37 of 40 patients (92.5%). In total, 181 drivers (48 focal and 133 rotational) were ablated, with an ablation response achieved in 59 (32.6%). Focal drivers and drivers with a higher recurrence rate and greater temporal stability were more likely to be associated with an ablation response including AF termination (P <.001). CONCLUSION: ECGI-guided ablation plus PVI results in high freedom from AF during follow-up and an ablation response in a large proportion of patients. Using driver type and characteristics may facilitate a hierarchical ablation approach.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Veias Pulmonares , Taquicardia Supraventricular , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Ablação por Cateter/métodos , Frequência Cardíaca/fisiologia , Humanos , Veias Pulmonares/cirurgia , Recidiva , Fatores de Tempo , Resultado do Tratamento
5.
Arrhythm Electrophysiol Rev ; 10(2): 91-100, 2021 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-34401181

RESUMO

Despite advances in the field of cardiac resynchronisation therapy (CRT), response rates and durability of therapy remain relatively static. Optimising device timing intervals may be the most common modifiable factor influencing CRT efficacy after implantation. This review addresses the concept of fusion pacing as a method for improving patient outcomes with CRT. Fusion pacing describes the delivery of CRT pacing with a programming strategy to preserve intrinsic atrioventricular (AV) conduction and ventricular activation via the right bundle branch. Several methods have been assessed to achieve fusion pacing. QRS complex duration (QRSd) shortening with CRT is associated with improved clinical response. Dynamic algorithm-based optimisation targeting narrowest QRSd in patients with intact AV conduction has shown promise in people with heart failure with left bundle branch block. Individualised dynamic programming achieving fusion may achieve the greatest magnitude of electrical synchrony, measured by QRSd narrowing.

8.
Echo Res Pract ; 5(1): 1-9, 2018 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-29258998

RESUMO

OBJECTIVE: Patients with non-ischaemic systolic heart failure (HF) and idiopathic dilated cardiomyopathy (DCM) are a heterogenous group with varied morbidity and mortality. Prognostication in this group is challenging. We performed a systematic review and meta-analysis to examine the significance of the presence of contractile reserve as assessed via stress imaging on mortality and hospitalisation. METHODS: A search for studies that non-invasively assessed contractile reserve in patients with DCM or non-ischaemic HF with reduced ejection fraction, stress imaging with follow-up data comparing outcomes. A range of imaging modalities and stressors were included. We examined primary endpoints of mortality and secondary endpoints of combined cardiovascular events including HF progression or hospitalisation. Our analysis compared endpoints in patients with contractile reserve and those without it. RESULTS: Nine prospective cohort studies were identified describing a total of 787 patients. These studies are methodologically but not statistically heterogenous (I2 = 31%). Using a random effect model, the presence of contractile reserve was associated with a significantly lower risk of mortality and cardiovascular events odds ratios of 0.20 (CI 0.11, 0.39) (P < 0.00001) and 0.13 (CI 0.04, 0.40) (P = 0.0004), respectively. CONCLUSION: Regardless of stressor and imaging modality and despite the significant methodological heterogeneity within the current data (imaging techniques and parameters), patients with non-ischaemic cardiomyopathy and reduced EF who demonstrate contractile reserve have a lower mortality, and lower events/hospitalisations. The presence of contractile reserve therefore offers a potential positive prognostic indicator when managing these patients.