Hemodial Int ; 23(4): E106-E110, 2019 10.
Artigo em Inglês | MEDLINE | ID: mdl-31115142

RESUMO

As maintenance hemodialysis patients are exposed to large quantities of dialysis water, any contamination of it might be reflected in plasma levels. We present a series of cases due to such a contamination. Six maintenance hemodialysis patients dialyzing at the same peripheral hemodialysis facility presented to us over a short period of time with symptoms mimicking inadequate dialysis. Their blood urea and creatinine levels were not very high, but all the patients had hypermagnesemia [serum Mg levels = 1.8 (±0.3) mmol/L]. Except for one patient who had cardiac arrest at presentation, all patients improved after undergoing hemodialysis at our center [serum Mg at discharge = 0.86 (±0.01) mmol/L]. The origin of hypermagnesemia was traced to dialysis water contamination with magnesium due to inadequate maintenance of the water treatment system. Corrective measures improved the quality of water, and no further cases were reported from that center. Proper maintenance and periodic checks of the quality of water are central to the outcomes of maintenance hemodialysis patients.


Assuntos
Soluções para Diálise/efeitos adversos , Falência Renal Crônica/complicações , Falência Renal Crônica/terapia , Magnésio/efeitos adversos , Debilidade Muscular/induzido quimicamente , Náusea/induzido quimicamente , Diálise Renal/efeitos adversos , Humanos , Magnésio/sangue , Masculino , Pessoa de Meia-Idade , Diálise Renal/métodos