Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
1.
Eur Urol ; 82(3): 318-326, 2022 09.
Artigo em Inglês | MEDLINE | ID: mdl-35341658

RESUMO

BACKGROUND: European Association of Urology guidelines recommend a risk-adjusted biopsy strategy for early detection of prostate cancer in biopsy-naïve men. It remains unclear which strategy is most effective. Therefore, we evaluated two risk assessment pathways commonly used in clinical practice. OBJECTIVE: To compare the diagnostic performance of a risk-based ultrasound (US)-directed pathway (Rotterdam Prostate Cancer Risk Calculator [RPCRC] #3; US volume assessment) and a magnetic resonance imaging (MRI)-directed pathway. DESIGN, SETTING, AND PARTICIPANTS: This was a prospective multicenter study (MR-PROPER) with 1:1 allocation among 21 centers (US arm in 11 centers, MRI arm in ten). Biopsy-naïve men with suspicion of prostate cancer (age ≥50 yr, prostate-specific antigen 3.0-50 ng/ml, ± abnormal digital rectal examination) were included. INTERVENTION: Biopsy-naïve men with elevated risk of prostate cancer, determined using RPCRC#3 in the US arm and Prostate Imaging Reporting and Data System scores of 3-5 in the MRI arm, underwent systematic biopsies (US arm) or targeted biopsies (MRI arm). OUTCOME MEASUREMENTS AND STATISTICAL ANALYSIS: The primary outcome was the proportion of men with grade group (GG) ≥2 cancer. Secondary outcomes were the proportions of biopsies avoided and GG 1 cancers detected. Categorical (nonparametric) data were assessed using the Mann-Whitney U test and χ2 tests. RESULTS AND LIMITATIONS: A total of 1965 men were included in the intention-to-treat population (US arm n = 950, MRI arm n = 1015). The US and MRI pathways detected GG ≥2 cancers equally well (235/950, 25% vs 239/1015, 24%; difference 1.2%, 95% confidence interval [CI] -2.6% to 5.0%; p = 0.5). The US pathway detected more GG 1 cancers than the MRI pathway (121/950, 13% vs 84/1015, 8.3%; difference 4.5%, 95% CI 1.8-7.2%; p < 0.01). The US pathway avoided fewer biopsies than the MRI pathway (403/950, 42% vs 559/1015, 55%; difference -13%, 95% CI -17% to -8.3%; p < 0.01). Among men with elevated risk, more GG ≥2 cancers were detected in the MRI group than in the US group (52% vs 43%; difference 9.2%, 95% CI 3.0-15%; p < 0.01). CONCLUSIONS: Risk-adapted US-directed and MRI-directed pathways detected GG ≥2 cancers equally well. The risk-adapted US-directed pathway performs well for prostate cancer diagnosis if prostate MRI capacity and expertise are not available. If prostate MRI availability is sufficient, risk assessment should preferably be performed using MRI, as this avoids more biopsies and detects fewer cases of GG 1 cancer. PATIENT SUMMARY: Among men with suspected prostate cancer, relevant cancers were equally well detected by risk-based pathways using either ultrasound or magnetic resonance imaging (MRI) to guide biopsy of the prostate. If prostate MRI availability is sufficient, risk assessment should be performed with MRI to reduce unnecessary biopsies and detect fewer irrelevant cancers.


Assuntos
Biópsia Guiada por Imagem , Neoplasias da Próstata , Humanos , Biópsia Guiada por Imagem/métodos , Imageamento por Ressonância Magnética/métodos , Masculino , Estudos Prospectivos , Próstata/diagnóstico por imagem , Próstata/patologia , Neoplasias da Próstata/patologia
2.
PLoS One ; 14(7): e0219291, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-31310623

RESUMO

OBJECTIVES: Autopsy rates worldwide have dropped significantly over the last decades and imaging-based autopsies are increasingly used as an alternative to conventional autopsy. Our aim was to evaluate the clinical performance and cost of minimally invasive autopsy. METHODS: This study was part of a prospective cohort study evaluating a newly implemented minimally invasive autopsy consisting of MRI, CT, and biopsies. We calculated diagnostic yield and clinical utility-defined as the percentage successfully answered clinical questions-of minimally invasive autopsy. We performed minimally invasive autopsy in 46 deceased (30 men, 16 women; mean age 62.9±17.5, min-max: 18-91). RESULTS: Ninety-six major diagnoses were found with the minimally invasive autopsy of which 47/96 (49.0%) were new diagnoses. CT found 65/96 (67.7%) major diagnoses and MRI found 82/96 (85.4%) major diagnoses. Eighty-four clinical questions were asked in all cases. Seventy-one (84.5%) of these questions could be answered with minimally invasive autopsy. CT successfully answered 34/84 (40.5%) clinical questions; in 23/84 (27.4%) without the need for biopsies, and in 11/84 (13.0%) a biopsy was required. MRI successfully answered 60/84 (71.4%) clinical questions, in 27/84 (32.1%) without the need for biopsies, and in 33/84 (39.8%) a biopsy was required. The mean cost of a minimally invasive autopsy was €1296 including brain biopsies and €1087 without brain biopsies. Mean cost of CT was €187 and of MRI €284. CONCLUSIONS: A minimally invasive autopsy, consisting of CT, MRI and CT-guided biopsies, performs well in answering clinical questions and detecting major diagnoses. However, the diagnostic yield and clinical utility were quite low for postmortem CT and MRI as standalone modalities.


Assuntos
Autopsia/economia , Autopsia/métodos , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Causas de Morte , Feminino , Hospitais , Humanos , Biópsia Guiada por Imagem/economia , Imageamento por Ressonância Magnética/economia , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Reprodutibilidade dos Testes , Tomografia Computadorizada por Raios X/economia , Adulto Jovem
3.
Radiology ; 289(3): 658-667, 2018 12.
Artigo em Inglês | MEDLINE | ID: mdl-30251930

RESUMO

Purpose To compare the diagnostic performance of minimally invasive autopsy with that of conventional autopsy. Materials and Methods For this prospective, single-center, cross-sectional study in an academic hospital, 295 of 2197 adult cadavers (mean age: 65 years [range, 18-99 years]; age range of male cadavers: 18-99 years; age range of female cadavers: 18-98 years) who died from 2012 through 2014 underwent conventional autopsy. Family consent for minimally invasive autopsy was obtained for 139 of the 295 cadavers; 99 of those 139 cadavers were included in this study. Those involved in minimally invasive autopsy and conventional autopsy were blinded to each other's findings. The minimally invasive autopsy procedure combined postmortem MRI, CT, and CT-guided biopsy of main organs and pathologic lesions. The primary outcome measure was performance of minimally invasive autopsy and conventional autopsy in establishing immediate cause of death, as compared with consensus cause of death. The secondary outcome measures were diagnostic yield of minimally invasive autopsy and conventional autopsy for all, major, and grouped major diagnoses; frequency of clinically unsuspected findings; and percentage of answered clinical questions. Results Cause of death determined with minimally invasive autopsy and conventional autopsy agreed in 91 of the 99 cadavers (92%). Agreement with consensus cause of death occurred in 96 of 99 cadavers (97%) with minimally invasive autopsy and in 94 of 99 cadavers (95%) with conventional autopsy (P = .73). All 288 grouped major diagnoses were related to consensus cause of death. Minimally invasive autopsy enabled diagnosis of 259 of them (90%) and conventional autopsy 224 (78%); 200 (69%) were found with both methods. At clinical examination, the cause of death was not suspected in 17 of the 99 cadavers (17%), and 124 of 288 grouped major diagnoses (43%) were not established. There were 219 additional clinical questions; 189 (86%) were answered with minimally invasive autopsy and 182 (83%) were answered with conventional autopsy (P = .35). Conclusion The performance of minimally invasive autopsy in the detection of cause of death was similar to that of conventional autopsy; however, minimally invasive autopsy has a higher yield of diagnoses. © RSNA, 2018 Online supplemental material is available for this article. See also the editorial by Krombach in this issue.


Assuntos
Autopsia/métodos , Causas de Morte , Imageamento por Ressonância Magnética/métodos , Radiografia Intervencionista/métodos , Tomografia Computadorizada por Raios X/métodos , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Cadáver , Estudos Transversais , Feminino , Humanos , Biópsia Guiada por Imagem/métodos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Reprodutibilidade dos Testes , Adulto Jovem
4.
Eur Heart J Cardiovasc Imaging ; 19(7): 739-748, 2018 07 01.
Artigo em Inglês | MEDLINE | ID: mdl-29474537

RESUMO

Aims: The autopsy rate worldwide is alarmingly low (0-15%). Mortality statistics are important, and it is, therefore, essential to perform autopsies in a sufficient proportion of deaths. The imaging autopsy, non-invasive, or minimally invasive autopsy (MIA) can be used as an alternative to the conventional autopsy in an attempt to improve postmortem diagnostics by increasing the number of postmortem procedures. The aim of this study was to determine the diagnostic accuracy of postmortem magnetic resonance imaging (MRI), computed tomography (CT), and CT-guided biopsy for the detection of acute and chronic myocardial ischaemia. Methods and results: We included 100 consecutive adult patients who died in hospital, and for whom next-of-kin gave permission to perform both conventional autopsy and MIA. The MIA consists of unenhanced total-body MRI and CT followed by CT-guided biopsies. Conventional autopsy was used as reference standard. We calculated sensitivity and specificity and receiver operating characteristics curves for CT and MRI as the stand-alone test or combined with biopsy for detection of acute and chronic myocardial infarction (MI). Sensitivity and specificity of MRI with biopsies for acute MI was 0.97 and 0.95, respectively and 0.90 and 0.75, respectively for chronic MI. MRI without biopsies showed a high specificity (acute: 0.92; chronic: 1.00), but low sensitivity (acute: 0.50; chronic: 0.35). CT (total Agatston calcium score) had a good diagnostic value for chronic MI [area under curve (AUC) 0.74, 95% confidence interval (CI) 0.64-0.84], but not for acute MI (AUC 0.60, 95% CI 0.48-0.72). Conclusion: We found that the combination of MRI with biopsies had high sensitivity and specificity for the detection of acute and chronic myocardial ischaemia.


Assuntos
Autopsia/métodos , Biópsia Guiada por Imagem/métodos , Imageamento por Ressonância Magnética/métodos , Infarto do Miocárdio/diagnóstico por imagem , Tomografia Computadorizada por Raios X/métodos , Centros Médicos Acadêmicos , Doença Aguda , Adulto , Idoso , Idoso de 80 Anos ou mais , Área Sob a Curva , Doença Crônica , Estudos Transversais , Feminino , Mortalidade Hospitalar , Humanos , Masculino , Pessoa de Meia-Idade , Infarto do Miocárdio/patologia , Isquemia Miocárdica/diagnóstico por imagem , Isquemia Miocárdica/patologia , Variações Dependentes do Observador , Estudos Prospectivos , Curva ROC , Sensibilidade e Especificidade
5.
PLoS One ; 12(9): e0185115, 2017.
Artigo em Inglês | MEDLINE | ID: mdl-28953923

RESUMO

OBJECTIVES: To evaluate the frequency of total-body CT and MR features of postmortem change in in-hospital deaths. MATERIALS AND METHODS: In this prospective blinded cross-sectional study, in-hospital deceased adult patients underwent total-body postmortem CT and MR followed by image-guided biopsies. The presence of PMCT and PMMR features related to postmortem change was scored retrospectively and correlated with postmortem time interval, post-resuscitation status and intensive care unit (ICU) admittance. RESULTS: Intravascular air, pleural effusion, periportal edema, and distended intestines occurred more frequently in patients who were resuscitated compared to those who were not. Postmortem clotting was seen less often in resuscitated patients (p = 0.002). Distended intestines and loss of grey-white matter differentiation in the brain showed a significant correlation with postmortem time interval (p = 0.001, p<0.001). Hyperdense cerebral vessels, intravenous clotting, subcutaneous edema, fluid in the abdomen and internal livores of the liver were seen more in ICU patients. Longer postmortem time interval led to a significant increase in decomposition related changes (p = 0.026). CONCLUSIONS: There is a wide variety of imaging features of postmortem change in in-hospital deaths. These imaging features vary among clinical conditions, increase with longer postmortem time interval and must be distinguished from pathologic changes.


Assuntos
Mortalidade Hospitalar , Imageamento por Ressonância Magnética , Mudanças Depois da Morte , Tomografia Computadorizada por Raios X , Adulto , Idoso , Idoso de 80 Anos ou mais , Estudos Transversais , Feminino , Humanos , Unidades de Terapia Intensiva/estatística & dados numéricos , Masculino , Pessoa de Meia-Idade , Ressuscitação
6.
Eur Radiol ; 26(4): 1159-79, 2016 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-26210206

RESUMO

OBJECTIVES: Autopsies are used for healthcare quality control and improving medical knowledge. Because autopsy rates are declining worldwide, various non-invasive or minimally invasive autopsy methods are now being developed. To investigate whether these might replace the invasive autopsies conventionally performed in naturally deceased adults, we systematically reviewed original prospective validation studies. MATERIALS AND METHODS: We searched six databases. Two reviewers independently selected articles and extracted data. Methods and patient groups were too heterogeneous for meaningful meta-analysis of outcomes. RESULTS: Sixteen of 1538 articles met our inclusion criteria. Eight studies used a blinded comparison; ten included less than 30 appropriate cases. Thirteen studies used radiological imaging (seven dealt solely with non-invasive procedures), two thoracoscopy and laparoscopy, and one sampling without imaging. Combining CT and MR was the best non-invasive method (agreement for cause of death: 70 %, 95%CI: 62.6; 76.4), but minimally invasive methods surpassed non-invasive methods. The highest sensitivity for cause of death (90.9 %, 95%CI: 74.5; 97.6, suspected duplicates excluded) was achieved in recent studies combining CT, CT-angiography and biopsies. CONCLUSION: Minimally invasive autopsies including biopsies performed best. To establish a feasible alternative to conventional autopsy and to increase consent to post-mortem investigations, further research in larger study groups is needed. KEY POINTS: • Health care quality control benefits from clinical feedback provided by (alternative) autopsies. • So far, sixteen studies investigated alternative autopsy methods for naturally deceased adults. • Thirteen studies used radiological imaging modalities, eight tissue biopsies, and three CT-angiography. • Combined CT, CT-angiography and biopsies were most sensitive diagnosing cause of death.


Assuntos
Autopsia/métodos , Adulto , Angiografia , Biópsia/métodos , Causas de Morte , Humanos , Estudos Prospectivos , Tomografia Computadorizada por Raios X
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...