1.
Can J Urol ; 30(5): 11703-11707, 2023 10.
Artigo em Inglês | MEDLINE | ID: mdl-37838999

RESUMO

INTRODUCTION: Liposomal bupivacaine (LB) is a depot formulation of bupivacaine, which releases the drug over 72 hours to prolong local pain control. This retrospective study compares the effect of using LB versus plain bupivacaine on postoperative pain control, length of hospital stay and cost among patients undergoing vaginal reconstructive surgery. MATERIALS AND METHODS: Patients who underwent vaginal reconstructive surgery with levatorplasty and received an injection of 20 cc of either plain bupivacaine or LB for pudendal nerve block were included. The primary outcomes included postoperative narcotic use and subjective pain score. The secondary outcome was postoperative length of stay. Comparisons between groups were performed using the T test, Mann Whitney U and Chi-square tests with p < 0.05 considered significant. RESULTS: Between June 2016 and December 2021, 25 patients had received LB as a pudendal nerve block and 25 had received plain bupivacaine. Demographics between groups were similar. There was no difference between postoperative morphine equivalent dose (MED) for plain bupivacaine versus LB (25.3 ± 65.8 vs. 24.9 ± 31.7 MED; p = 0.159) or length of hospital stay (15.8 ± 12.0 hours vs. 23.8 ± 20.0; p = 0.094). Furthermore, subjective pain was also similar between groups (0 vs. 1.6 ± 2.6, p = 0.68), (4.6 ± 2.3 vs. 4.9 ± 2.0 average POD 1 pain, p = 0.534) and (4.3 ± 2.1 for vs. 4.9 ± 2.1 average POD 2 pain, p = 0.373). CONCLUSION: LB is not superior to plain bupivacaine for controlling pain following vaginal reconstructive surgery, and justification for the exponentially greater cost of LB is not supported. Prospective investigations with larger sample sizes are needed to determine the optimal pain management for levatorplasty in vaginal reconstructive surgery.


Assuntos
Bupivacaína , Manejo da Dor , Feminino , Humanos , Anestésicos Locais , Dor Pós-Operatória/tratamento farmacológico , Dor Pós-Operatória/etiologia , Dor Pós-Operatória/prevenção & controle , Estudos Retrospectivos , Estudos Prospectivos , Lipossomos , Analgésicos Opioides
2.
J Endourol ; 26(11): 1489-93, 2012 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-22712538

RESUMO

BACKGROUND AND PURPOSE: Automatic brightness control (ABC), a function of modern fluoroscopy machines, adjusts radiation intensity in real time to enhance image quality. While shielding reduces radiation exposure to protected areas, it is unknown how much radiation adjacent unshielded areas receive when using ABC settings. Our purpose was to assess radiation dosage to shielded and unshielded tissue when using fluoroscopic ABC mode compared with fixed exposure settings. MATERIALS AND METHODS: In a simulated ureteroscopy, thermoluminescent dosimeters (TLDs) were placed at three sites in a female human cadaver, including the right renal hilum, right distal ureter adjacent to the uterus, and directly over the uterus. The cadaver received 60 seconds of radiation exposure using a C-arm fluoroscopy system under ABC and fixed settings (1.38 mAs, 66 kVp) with and without uterine shielding. Radiation dosage absorbed by the TLDs was compared using two-way analysis of variance and least-squares confidence intervals. RESULTS: Shielding significantly reduced radiation dose to the uterus by 62% and 82% (P<0.05 for both) in ABC and fixed settings, respectively. Shielding of the uterus in ABC, however, resulted in an approximately twofold increase in radiation dosage to the ureter and ipsilateral kidney (P<0.05 for both) and a decrease in image quality. Using fixed settings, shielding of the uterus did not increase radiation dose to the ipsilateral ureter and kidney. CONCLUSION: There is a significant increase in radiation dosage to surrounding tissues when shielding is used with ABC mode during fluoroscopy. Radiation can be reduced and image quality improved by using fixed settings when shielding is indicated.


Assuntos
Fluoroscopia , Doses de Radiação , Proteção Radiológica , Automação , Intervalos de Confiança , Feminino , Humanos , Análise dos Mínimos Quadrados , Cálculos Ureterais/diagnóstico por imagem