Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Med Sci Sports Exerc ; 56(4): 644-654, 2024 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-38079307

RESUMO

INTRODUCTION: Heat adaptation is protective against heat illness; however, its role in heat syncope, due to reflex mechanisms, has not been conclusively established. The aim of this study was to evaluate if heat acclimation (HA) was protective against heat syncope and to ascertain underlying physiological mechanisms. METHODS: Twenty (15 males, 5 females) endurance-trained athletes were randomized to either 8 d of mixed active and passive HA (HEAT) or climatically temperate exercise (CONTROL). Before, and after, the interventions participants underwent a head up tilt (HUT) with graded lower body negative pressure (LBNP), in a thermal chamber (32.0 ± 0.3°C), continued until presyncope with measurement of cardiovascular parameters. Heat stress tests (HST) were performed to determine physiological and perceptual measures of HA. RESULTS: There was a significant increase in orthostatic tolerance (OT), as measured by HUT/LBNP, in the HEAT group (preintervention; 28 ± 9 min, postintervention; 40 ± 7 min) compared with CONTROL (preintervention; 30 ± 8 mins, postintervention; 33 ± 5 min) ( P = 0.01). Heat acclimation resulted in a significantly reduced peak and mean rectal and skin temperature ( P < 0.01), peak heat rate ( P < 0.003), thermal comfort ( P < 0.04), and rating of perceived exertion ( P < 0.02) during HST. There was a significantly increased plasma volume (PV) in the HEAT group in comparison to CONTROL ( P = 0.03). CONCLUSIONS: Heat acclimation causes improvements in OT and is likely to be beneficial in patients with heat exacerbated reflex syncope. Heat acclimation-mediated PV expansion is a potential physiological mechanism underlying improved OT.


Assuntos
Transtornos de Estresse por Calor , Termotolerância , Masculino , Feminino , Humanos , Exercício Físico/fisiologia , Temperatura Cutânea , Síncope , Transtornos de Estresse por Calor/prevenção & controle , Aclimatação/fisiologia , Temperatura Alta , Temperatura Corporal , Frequência Cardíaca
2.
Int J Sports Med ; 44(3): 184-191, 2023 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-35777726

RESUMO

The purpose of this study was to assess the reliability of blood biomarkers that can signify exercise-induced heat stress in hot conditions. Fourteen males completed two heat stress tests separated by 5-7 days. Venous blood was drawn pre- and post- heat stress for the concentration of normetanephrine, metanephrine, serum osmolality, copeptin, kidney-injury molecule 1, and neutrophil gelatinase-associated lipocalin. No biomarker, except copeptin, displayed systematic trial order bias (p≥0.05). Normetanephrine, copeptin and neutrophil gelatinase-associated lipocalin presented acceptable reliability (CV range: 0.9-14.3%), while greater variability was present in metanephrine, osmolality and kidney-injury molecule 1 (CV range: 28.6-43.2%). Normetanephrine exhibited the largest increase (p<0.001) in response to heat stress (trial 1=1048±461 pmol. L-1; trial 2=1067±408 pmol. L-1), whilst kidney-injury molecule 1 presented trivial changes (trial 1=-4±20 ng. L-1; trial 2=2 ± 16 ng. L-1, p>0.05). Normetanephrine, copeptin, and neutrophil gelatinase-associated lipocalin demonstrated good reliability and sensitivity to an acute bout of heat stress. These biomarkers may be suitable for application in laboratory and field research to understand the efficacy of interventions that can attenuate the risk of thermal injury whilst exercising in the heat.


Assuntos
Transtornos de Estresse por Calor , Normetanefrina , Masculino , Humanos , Lipocalina-2 , Metanefrina , Reprodutibilidade dos Testes , Biomarcadores , Estresse Fisiológico
3.
Scand J Med Sci Sports ; 32(1): 83-93, 2022 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-34606650

RESUMO

Measurements of muscle-tendon unit passive mechanical properties are often used to illustrate acute and chronic responses to a training stimulus. The purpose of this study was to quantify the inter-session repeatability of triceps surae passive stiffness measurements in athletic and non-athletic populations, with the view to discussing its usefulness both as a muscle-tendon profiling tool and a control measure for studies with multiple data collection sessions. The study also aimed to observe the effects of quiet standing on passive stiffness parameters. Twenty-nine men (10 cyclists, nine triathletes, 10 controls) visited the laboratory on three separate occasions, where passive stiffness tests were carried out using an isokinetic dynamometer and B-mode ultrasound. Participants were fully rested on two of the sessions and subjected to 20 min of quiet standing in the other. The passive stiffness assessment generally showed only moderate inter-session repeatability but was still able to detect inter-group differences, with triathletes showing higher passive stiffness than cyclists (p < 0.05). Furthermore, quiet standing impacted passive stiffness by causing a reduction in ankle joint range of motion, although mechanical resistance to stretch in the muscle-tendon unit at a given joint angle was relatively unaffected. These findings show that passive stiffness assessment is appropriate for detecting inter-group differences in the triceps surae and even the effects of a low-intensity task such as quiet standing, despite showing some inter-session variation. However, the inter-session variation suggests that passive stiffness testing might not be suitable as a control measure when testing participants on multiple sessions.


Assuntos
Tendão do Calcâneo , Articulação do Tornozelo , Eletromiografia , Humanos , Masculino , Músculo Esquelético , Amplitude de Movimento Articular
4.
J Sports Sci ; 39(21): 2485-2492, 2021 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-34134607

RESUMO

Key areas of sports science research investigate the functional role of muscle activations within human movement. Even within relatively constrained movements like cycling, significant variability is observed in muscle activation strategies. Particular attention has been given to particular muscles, despite Soleus and Tibialis anterior muscles presenting a potentially functionally relevant split between monomodal and bimodal activation strategies. The current study (N = 54) investigated the prevalence and functional implications of these different strategies and identified, in addition to monomodal [Soleus: N = 24, Tibialis anterior: N = 7] and bimodal [Soleus: N = 12, Tibialis anterior: N = 31] strategies, a third group switching between strategies [Soleus: N = 16, Tibialis anterior: N = 13]. The combined Soleus group showed significantly higher Index of Force Effectiveness, lower negative work and lower radial forces than the bimodal group. Furthermore, bimodal Soleus strategies produced a period of significantly greater plantar flexion during the upstroke. No differences were found between the Tibialis anterior groups. These data show an identifiable group of cyclists utilising a combination of monomodal and bimodal strategies potentially benefiting mechanical effectiveness. Awareness of such functional implications can aid researchers and practitioners when interpreting cycling biomechanics data or intervention responses. Further research should investigate the factors that mediate transitions between activation strategies within the combined groups.


Assuntos
Ciclismo/fisiologia , Perna (Membro)/fisiologia , Músculo Esquelético/fisiologia , Adulto , Articulação do Tornozelo/fisiologia , Fenômenos Biomecânicos , Eletromiografia , Articulação do Quadril/fisiologia , Humanos , Articulação do Joelho/fisiologia , Pessoa de Meia-Idade , Amplitude de Movimento Articular , Estudos de Tempo e Movimento
5.
J Therm Biol ; 93: 102705, 2020 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-33077126

RESUMO

Heat adaption through acclimatisation or acclimation improves cardiovascular stability by maintaining cardiac output due to compensatory increases in stroke volume. The main aim of this study was to assess whether 2D transthoracic echocardiography (TTE) could be used to confirm differences in resting echocardiographic parameters, before and after active heat acclimation (HA). Thirteen male endurance trained cyclists underwent a resting blinded TTE before and after randomisation to either 5 consecutive daily exertional heat exposures of controlled hyperthermia at 32°C with 70% relative humidity (RH) (HOT) or 5-days of exercise in temperate (21°C with 36% RH) environmental conditions (TEMP). Measures of HA included heart rate, gastrointestinal temperature, skin temperature, sweat loss, total non-urinary fluid loss (TNUFL), plasma volume and participant's ratings of perceived exertion (RPE). Following HA, the HOT group demonstrated increased sweat loss (p = 0.01) and TNUFL (p = 0.01) in comparison to the TEMP group with a significantly decreased RPE (p = 0.01). On TTE, post exposure, there was a significant comparative increase in the HOT group in left ventricular end diastolic volume (p = 0.029), SV (p = 0.009), left atrial volume (p = 0.005), inferior vena cava diameter (p = 0.041), and a significant difference in mean peak diastolic mitral annular velocity (e') (p = 0.044). Cardiovascular adaptations to HA appear to be predominantly mediated by improvements in increased preload and ventricular compliance. TTE is a useful tool to demonstrate and quantify cardiac HA.


Assuntos
Exercício Físico , Coração/fisiologia , Sudorese , Termotolerância , Adulto , Ecocardiografia , Coração/diagnóstico por imagem , Frequência Cardíaca , Humanos , Masculino , Volume Plasmático , Distribuição Aleatória , Vasodilatação
6.
J Strength Cond Res ; 34(3): 828-837, 2020 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-29939897

RESUMO

Robertson, C, Lodin-Sundström, A, O'Hara, J, King, R, Wainwright, B, and Barlow, M. Effects of pre-race apneas on 400-m freestyle swimming performance. J Strength Cond Res 34(3): 828-837, 2020-This study aimed to establish whether a series of 3 apneas before a 400-m freestyle time-trial affected swimming performance when compared with and combined with a warm-up. Nine (6 males and 3 females) regional to national standard swimmers completed four 400-m freestyle time-trials in 4 randomized conditions: without warm-up or apneas (CON), warm-up only (WU), apneas only (AP), and warm-up and apneas (WUAP). Time-trial performance was significantly improved after WUAP (275.79 ± 12.88 seconds) compared with CON (278.66 ± 13.31 seconds, p = 0.035) and AP (278.64 ± 4.10 seconds, p = 0.015). However, there were no significant differences between the WU (276.01 ± 13.52 seconds, p > 0.05) and other interventions. Spleen volume compared with baseline was significantly reduced after the apneas by a maximum of ∼45% in the WUAP and by ∼20% in WU. This study showed that the combination of a warm-up with apneas could significantly improve 400-m freestyle swim performance compared with a control and apnea intervention. Further investigation into whether long-term apnea training can enhance this response is justified.


Assuntos
Apneia/fisiopatologia , Desempenho Atlético/fisiologia , Natação/fisiologia , Exercício de Aquecimento/fisiologia , Adolescente , Estudos Cross-Over , Feminino , Humanos , Masculino , Adulto Jovem
7.
J Sports Sci ; 35(14): 1451-1458, 2017 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-27552233

RESUMO

The purpose of the study was to assess the validity and inter-bike reliability of 10 Wattbike cycle ergometers, and to assess the test-retest reliability of one Wattbike. Power outputs from 100 to 1000 W were applied using a motorised calibration rig (LODE) at cadences of 70, 90, 110 and 130 rev · min-1, which created nineteen different intensities for comparison. Significant relationships (P < 0.01, r2 = 0.99) were found between each of the Wattbikes and the LODE. Each Wattbike was found to be valid and reliable and had good inter-bike agreement. Within-bike mean differences ranged from 0.0 W to 8.1 W at 300 W and 3.3 W to 19.3 W at 600 W. When taking into account the manufacturers stated measurement error for the LODE (2%), the mean differences were less than 2%. Comparisons between Wattbikes at each of the nineteen intensities gave differences from 0.6 to 25.5 W at intensities of 152 W and 983 W, respectively. There was no significant difference (P > 0.05) between the measures of power recorded in the test-retest condition. The data suggest that the Wattbike is an accurate and reliable tool for training and performance assessments, with data between Wattbikes being able to be used interchangeably.


Assuntos
Ciclismo/fisiologia , Ergometria/instrumentação , Desempenho Atlético/fisiologia , Calibragem , Ergometria/normas , Humanos , Reprodutibilidade dos Testes
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...