Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
J Chem Educ ; 100(11): 4279-4286, 2023 Nov 14.
Artigo em Inglês | MEDLINE | ID: mdl-38028751

RESUMO

All learners have a contribution to make to the development of the Chemical Sciences, be that in novel ways to teach, and their perspectives and contexts, but also in research, both in chemical education and the wider Chemical Sciences. Through four case studies, this paper explores interactions with diverse groups and how this has altered perspectives on both teaching and research. The case studies include work with visually impaired adults, a project bringing together First Peoples in Australia with academics to explore old ways (traditional science) and new ways (modern approaches), primary (elementary) school perspectives on teaching science, and a project in South Africa to connect university and township communities. Not only do these case studies demonstrate the immense value these diverse groups bring to our understanding about how to learn, but they also bring new perspectives on how to view and solve chemical problems.

2.
Sensors (Basel) ; 23(4)2023 Feb 20.
Artigo em Inglês | MEDLINE | ID: mdl-36850929

RESUMO

In this study, a solid-state modified pH sensor with RF magnetron sputtering technology was developed. The sensor consists of an active electrode consisting of a titanium nitride (TiN) film with a protective membrane of Nafion and a reference glass electrode of Ag/AgCl. The sensitivity of the pH sensor was investigated. Results show a sensor with excellent characteristics: sensitivity of 58.6 mV/pH for pH values from 2 to 12, very short response time of approximately 12 s in neutral pH solutions, and stability of less than 0.9 mV in 10 min duration. Further improvement in the performance of the TiN sensor was studied by application of a Nafion protective membrane. Nafion improves the sensor sensitivity close to Nernstian by maintaining a linear response. This paves the way to implement TiN with Nafion protection to block any interference species during real time applications in biosensing and medical diagnostic pH sensors.

3.
Sensors (Basel) ; 23(2)2023 Jan 07.
Artigo em Inglês | MEDLINE | ID: mdl-36679497

RESUMO

pH sensors are increasingly being utilized in the biomedical field and have been implicated in health applications that aim to improve the monitoring and treatment of patients. In this work, a previously developed Titanium Nitride (TiN) solid-state pH sensor is further enhanced, with the potential to be used for pH regulation inside the human body and for other biomedical, industrial, and environmental applications. One of the main limitations of existing solid-state pH sensors is their reduced performance in high redox mediums. The potential shift E0 value of the previously developed TiN pH electrode in the presence of oxidizing or reducing agents is 30 mV. To minimize this redox shift, a Nafion-modified TiN electrode was developed, tested, and evaluated in various mediums. The Nafion-modified electrode has been shown to shift the E0 value by only 2 mV, providing increased accuracy in highly redox samples while maintaining acceptable reaction times. Overcoming the redox interference for pH measurement enables several advantages of the Nafion-modified TiN electrode over the standard pH glass electrode, implicating its use in medical diagnosis, real-time health monitoring, and further development of miniaturized smart sensors.


Assuntos
Titânio , Humanos , Eletrodos , Concentração de Íons de Hidrogênio
4.
Artigo em Inglês | MEDLINE | ID: mdl-36141985

RESUMO

Lead levels at a new indoor target shooting range were assessed using both personal and environmental air monitoring methods. Surface swabs were collected from representative locations throughout the range prior to, and at the conclusion of, shooting. Personal samples were compared against the current Australian Workplace Exposure Standards with all results exceeding statutory limits. Static environmental samples exceeded the Air National Environmental Protection Measures (NEPM) air quality standard. Surface swabs showed significant increases from pre- to post-shooting with levels exceeding recommended limits. The performance of the mechanical ventilation system was also assessed and airflow levels were below the required rate at all test locations when compared against the values recommended by the National Institute for Occupational Safety and Health (NIOSH). Users of the indoor shooting range are at risk of potential exposure to hazardous levels of lead. It was recommended the ventilation system be reviewed by a suitably qualified ventilation engineer to ensure it is operating within the required parameters and able to transport generated lead contaminant away from the shooters breathing zone. A thorough cleaning regime should be implemented by the club to minimise surface lead loadings throughout the facility.


Assuntos
Poluição do Ar em Ambientes Fechados , Armas de Fogo , Exposição Ocupacional , Poluição do Ar em Ambientes Fechados/análise , Austrália , Monitoramento Ambiental/métodos , Chumbo , Exposição Ocupacional/análise , Ventilação
5.
Sensors (Basel) ; 21(1)2020 Dec 23.
Artigo em Inglês | MEDLINE | ID: mdl-33374837

RESUMO

In this work, a solid-state potentiometric pH sensor is designed by incorporating a thin film of Radio Frequency Magnetron Sputtered (RFMS) Titanium Nitride (TiN) working electrode and a commercial Ag|AgCl|KCl double junction reference electrode. The sensor shows a linear pH slope of -59.1 mV/pH, R2 = 0.9997, a hysteresis as low as 1.2 mV, and drift below 3.9 mV/hr. In addition, the redox interference performance of TiN electrodes is compared with that of Iridium Oxide (IrO2) counterparts. Experimental results show -32mV potential shift (E0 value) in 1 mM ascorbic acid (reducing agent) for TiN electrodes, and this is significantly lower than the -114 mV potential shift of IrO2 electrodes with sub-Nernstian sensitivity. These results are most encouraging and pave the way towards the development of miniaturized, cost-effective, and robust pH sensors for difficult matrices, such as wine and fresh orange juice.

6.
Sensors (Basel) ; 17(9)2017 Sep 06.
Artigo em Inglês | MEDLINE | ID: mdl-28878182

RESUMO

A pH-sensitive RuO₂ electrode coated in a commercial cyanoacrylate adhesive typically exhibits very low pH sensitivity, and could be paired with a RuO₂ working electrode as a differential type pH sensor. However, such sensors display poor performance in real sample matrices. A pH sensor employing a RuO₂ pH-sensitive working electrode and a SiO₂-PVB junction-modified RuO₂ reference electrode is developed as an alternative high-performance solution. This sensor exhibits a performance similar to that of a commercial glass pH sensor in some common sample matrices, particularly, an excellent pH sensitivity of 55.7 mV/pH, a hysteresis as low as 2.7 mV, and a drift below 2.2 mV/h. The developed sensor structure opens the way towards the development of a simple, cost effective, and robust pH sensor for pH analysis in various sample matrices.

7.
Artigo em Inglês | MEDLINE | ID: mdl-26027003

RESUMO

Neutron diffraction structures of water molecules in crystalline hydrates of metal salts have been collected from the literature up to December 2011. Statistical methods were used to investigate the influence on the water structures of the position and nature of hydrogen bond acceptors and cations coordinated to the water oxygen. For statistical modelling the data were pruned so that only structures with oxygen as hydrogen acceptors, single hydrogen bonds, and no more than two metals or hydrogens coordinated to the water oxygen were included. Multiple linear regression models were fitted with the water OH bond length and bond angle as response variables. Other variables describing the position and nature of the acceptors and ions coordinated to the waters were taken as explanatory variables. These variables were sufficient to give good models for the bond lengths and angles. There were sufficient structures involving coordinated Mg(2+) or Cu(2+) for a separate statistical modelling to be done for these cases.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...