Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Nippon Ganka Gakkai Zasshi ; 108(4): 219-25, 2004 Apr.
Artigo em Japonês | MEDLINE | ID: mdl-15148738

RESUMO

BACKGROUND: We report a patient with acute angle-closure glaucoma secondary to annular ciliochoroidal detachment after unsutured cataract surgery. CASE: An 82-year-old man was diagnosed with bilateral shallow central anterior chamber depth, flat peripheral anterior chamber, and elevated intraocular pressure. One day previously he had undergone uncomplicated unsutured cataract surgery in the right eye and eight days previously, in the left eye. Ultrasound biomicroscopy revealed annular ciliochoroidal detachment in both eyes. Treatment with intravenous methyl prednisolone deepened the anterior chamber and reduced intraocular pressure. CONCLUSION: Annular ciliochoroidal detachment may lead to anterior rotation of the ciliary body and angle-closure. This clinical entity is indistinguishable from malignant glaucoma when the fundus cannot be visualized.


Assuntos
Extração de Catarata , Doenças da Coroide , Corpo Ciliar/patologia , Glaucoma de Ângulo Fechado/etiologia , Complicações Pós-Operatórias , Doença Aguda , Idoso , Idoso de 80 Anos ou mais , Extração de Catarata/métodos , Doenças da Coroide/terapia , Diagnóstico Diferencial , Glaucoma de Ângulo Fechado/diagnóstico , Glaucoma de Ângulo Fechado/terapia , Humanos , Masculino , Resultado do Tratamento
2.
Neurol Med Chir (Tokyo) ; 42(3): 143-6, 2002 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-11936059

RESUMO

A 56-year-old female presented with transorbital penetrating injury caused by bamboo fragments, which resulted in brain abscess 2 weeks after the injury. Initial computed tomography (CT) of the head did not reveal the foreign bodies. However, follow-up CT demonstrated a well-defined hyperdense abnormality of 1.0 cm length in the left orbit and brain abscess in the left temporal lobe. The lesion corresponding to the hyperdense abnormality on CT appeared isointense on T1-weighted magnetic resonance (MR) imaging and hypointense on T2-weighted MR imaging. The bamboo fragments were surgically removed, and aspiration and continuous drainage were performed for the brain abscess. The postoperative course was uneventful and the patient was transferred to a local hospital with minor neurological deficits. Bamboo foreign bodies may show changes in properties on CT and MR imaging in the subacute stage. Careful radiological examination and follow-up monitoring are required for the correct diagnosis and treatment of such injuries.


Assuntos
Abscesso Encefálico/cirurgia , Corpos Estranhos/cirurgia , Órbita/lesões , Caules de Planta , Ferimentos Penetrantes/cirurgia , Abscesso Encefálico/diagnóstico , Abscesso Encefálico/etiologia , Diagnóstico Diferencial , Feminino , Corpos Estranhos/diagnóstico , Humanos , Imageamento por Ressonância Magnética , Pessoa de Meia-Idade , Órbita/diagnóstico por imagem , Órbita/cirurgia , Lobo Temporal/patologia , Lobo Temporal/cirurgia , Tomografia Computadorizada por Raios X , Ferimentos Penetrantes/diagnóstico
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...