1.
Nihon Hoshasen Gijutsu Gakkai Zasshi ; 62(11): 1566-74, 2006 Nov 20.
Artigo em Japonês | MEDLINE | ID: mdl-17139238

RESUMO

Although the cleanliness of the angiography room and that of the operating room have long been equally attended to, the concept of Standard Precautions (including the basic measures and procedures to prevent infection) of the Centers for Disease Control and Prevention (CDC), 1996, as well as the introduction of transmission-based precautions, have been changing to preventive measures that are based on concrete measures. Therefore, a questionnaire was introduced in order to determine the actual status of countermeasures against infection used in the angiography room. The questionnaire was sent to 530 institutions, and 286 responded, a response rate of 54.0%. Its results significantly revealed the following: 1) unexpectedly low recognition of the need and importance for the CDC preventive measures against infection, 2) a considerable number of institutions continuing to perform the conventional preventive measures, 3) problems with education systems on preventive measures, and 4) handwashing, the most important measure against infection, failing to be adequately carried out noticeably among radiological technologists.


Assuntos
Angiografia , Controle de Infecções , Salas Cirúrgicas , Inquéritos e Questionários , Tecnologia Radiológica , Ambiente Controlado , Desinfecção das Mãos , Humanos , Infecções/transmissão , Japão , Roupa de Proteção
2.
Nihon Hoshasen Gijutsu Gakkai Zasshi ; 61(1): 71-8, 2005 Jan 20.
Artigo em Japonês | MEDLINE | ID: mdl-15682034

RESUMO

We evaluated the effect of changes in the direction of the coronary artery in terms of the accuracy and precision of vessel diameter measurement in a quantitative coronary angiography system (QCA system). Vessel phantoms sized 0.3, 0.5, 1.0, 1.5, 2.0, and 2.5 mm in diameter were evaluated. The phantoms were aligned on an acrylic plate, and the angle to the television (TV) camera was altered. The deployed angles were 0 (perpendicular), 45, 90, and 135 degrees in clockwise order. The phantoms were imaged with matrices of 1024 x 1024 (1024(2)), 512 x 512 (512(2)), and 512 x 1024. Image size was 7 inches, and the frame rate was 15 frames per second. Minimal lumen diameters were measured on the ACA system. The results revealed that, in the 1024(2) matrix, overall accuracy for the 90-degree angle was significantly underestimated compared with the 0-degree angle (-0.14 vs. -0.014 mm; p=0.007). Accuracy for the 90-degree angle was better than that for the 0-degree angle when the vessel diameter was 1 mm or smaller (-0.02+/-0.16 vs. 0.10+/-0.22 mm). In addition, precision was better at the 90-degree angle than with the other angles in the 1024(2) matrix (overall precision=0.002 mm). In the 512(2) matrix, overall accuracy for the 90-degree angle was significantly underestimated compared with the 45-degree angle (-0.077 vs. 0.096 mm; p=0.02). In addition, accuracy for the 90-degree angle was better than that for the 45-degree angle below 1 mm (0.05+/-0.24 mm vs. 0.26+/-0.47 mm). In terms of overall accuracy, the 45-degree angle in the 512(2) matrix showed significant overestimation compared with that in the 1024(2) matrix (0.096 vs. -0.069 mm; p=0.015). There was no difference in accuracy in the 512 x 1024 matrix. Our results suggest that the direction of the vessel against the TV image affects accuracy of measurement in the QCA system.


Assuntos
Angiografia Coronária/métodos , Humanos , Imagens de Fantasmas
3.
Nihon Hoshasen Gijutsu Gakkai Zasshi ; 59(3): 401-9, 2003 Mar.
Artigo em Japonês | MEDLINE | ID: mdl-12740563

RESUMO

Among several techniques for contrast-enhanced MRA, the elliptical centric view ordering method, originally developed at the Mayo Clinic, is a promising one. It has been difficult to apply a fat-suppression prepulse, mainly because the conventional fat suppression method requires a longer acquisition time during sampling of the low-frequency domain in k-space, and it causes severe image distortion due to the great change in longitudinal magnetization derived from fat tissue. We developed a novel method to append fat saturation to the elliptical centric view ordering technique, and assessed the feasibility of its use. Our method is to apply fat-saturation pulses only at selected sampling points when any gradient is applied in the slice-encoding direction. In this way, we achieved efficient suppression of fat-derived signal within a relatively short time, comparable to that of the conventional fat-saturation method, and succeeded in minimizing artifacts.


Assuntos
Angiografia por Ressonância Magnética/métodos , Artefatos , Coleta de Dados , Humanos , Angiografia por Ressonância Magnética/instrumentação
SELEÇÃO DE REFERÊNCIAS