Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Diagnostics (Basel) ; 14(6)2024 Mar 15.
Artigo em Inglês | MEDLINE | ID: mdl-38535042

RESUMO

In patients with premature ventricular contractions (PVCs), non-invasive mapping could locate the PVCs' origin on a personalized 3-dimensional (3D) heart model and, thus, facilitate catheter ablation therapy planning. The aim of our report is to evaluate its accuracy compared to invasive mapping in terms of assessing the PVCs' early activation zone (EAZ). For this purpose, non-invasive electrocardiographic imaging (ECGI) was performed using the Amycard 01C system (EP Solutions SA, Switzerland) in three cases. In the first step, a multichannel ECG (up to 224 electrodes) was recorded, and the dominant PVCs were registered. Afterward, a cardiac computed tomography (in two cases) or magnetic resonance imaging (in one case) investigation was carried out acquiring non-contrast torso scans for 8-electrode strip visualization and contrast heart acquisition. For the reconstructed epi/endocardial meshes of the heart, non-invasive isochronal maps were generated for the selected multichannel ECG fragments. Then, the patients underwent an invasive electrophysiological study, and the PVCs' activation was evaluated by a 3D mapping system (EnSite NavX Precision, Abbott). Finally, using custom-written software, we performed 3D fusion of the non-invasive and invasive models and compared the resulting isochronal maps. A qualitative analysis in each case showed the same early localization of the dominant PVC on the endocardial surface when comparing the non-invasive and invasive isochronal maps. The distance from the EAZ to the mitral or tricuspid annulus was comparable in the invasive/non-invasive data (36/41 mm in case N1, 73/75 mm in case N2, 9/12 mm in case N3). The area of EAZ was also similar between the invasive/non-invasive maps (4.3/4.5 cm2 in case N1, 7.1/7.0 cm2 in case N2, 0.4/0.6 cm2 in case N3). The distances from the non-invasive to invasive earliest activation site were 4 mm in case N1, 7 mm in case N2, and 4 mm in case N3. Such results were appropriate to trust the clinical value of the preoperative data in these cases. In conclusion, the non-invasive identification of PVCs before an invasive electrophysiological study can guide clinical and interventional decisions, demonstrating appropriate accuracy in the estimation of focus origin.

2.
Sci Rep ; 12(1): 3606, 2022 03 04.
Artigo em Inglês | MEDLINE | ID: mdl-35246595

RESUMO

Pace mapping and visual comparison of the local pacing response with the intrinsic QRS morphology form the mainstay of His bundle pacing (HBP). We evaluated the performance of a surface lead morphology match algorithm for automated classification of the pacing response in patients with narrow intrinsic QRS undergoing electroanatomic mapping (EAM)-guided HBP. HBP was attempted in 43 patients. In 28 cases with narrow QRS, the EnSite AutoMap Module was used for automated assessment of the QRS morphology resulting from pace mapping in the His cloud area with either a diagnostic catheter or the His lead. An intrinsic morphology match score (IMS) was calculated for 1.546 QRS complexes and assessed regarding its accuracy and performance in classifying the individual pacing response as either selective HBP (S-HBP), nonselective HBP (NS-HBP) or right ventricular stimulation. Automated morphology comparison of 354 intrinsic beats with the individual reference determined a test accuracy of 99% (95% CI 98.96-99.04) and a precision of 97.99-99.5%. For His-lead stimulation, an IMS ≥ 89% identified S-HBP with a sensitivity, specificity and positive predictive value of 1.00 (0.99, 1.00) and a negative predictive value of 0.99 (0.98, 1.00). An IMS between 78 and < 89% indicated NS-HBP with a sensitivity and specificity of 1.00 (0.99, 1.00) and 0.99 (0.98, 1.00), respectively. IMS represents a new automated measure for standardized individual morphology classification in patients with normal QRS undergoing EAM-guided HBP.Clinical trial registration: NCT04416958.


Assuntos
Fascículo Atrioventricular , Estimulação Cardíaca Artificial , Estimulação Cardíaca Artificial/métodos , Eletrocardiografia , Ventrículos do Coração , Humanos , Valor Preditivo dos Testes , Sensibilidade e Especificidade , Resultado do Tratamento
3.
Sensors (Basel) ; 21(24)2021 Dec 14.
Artigo em Inglês | MEDLINE | ID: mdl-34960440

RESUMO

BACKGROUND: ICDs and pacemakers for cardiac resynchronization therapy (CRT) are complex devices with different sensors and automatic algorithms implanted in patients with advanced cardiac diseases. Data on the perioperative management and outcome of CRT carriers undergoing surgery unrelated to the device are scarce. METHODS: Data from 198 CRT device carriers (100 with active rate responsive sensor) were evaluated regarding perioperative adverse (device-related) events (A(D)E) and lead parameter changes. RESULTS: Thirty-nine adverse observations were documented in 180 patients during preoperative interrogation, which were most often related to the left-ventricular lead and requiring intervention/reprogramming in 22 cases (12%). Anesthesia-related events occurred in 69 patients. There was no ADE for non-cardiac surgery and in pacemaker-dependent patients not programmed to an asynchronous pacing mode. Post-operative device interrogation showed significant lead parameter changes in 64/179 patients (36%) requiring reprogramming in 29 cases (16%). CONCLUSION: The left-ventricular pacing lead represents the most vulnerable system component. Comprehensive pre and post-interventional device interrogation is mandatory to ensure proper system function. The type of ICD function suspension has no impact on each patient's outcome. Precautionary activity sensor deactivation is not required for non-cardiac interventions. Routine prophylactic device reprogramming to asynchronous pacing appears inessential. Most of the CRT pacemakers do not require surgery-related reprogramming.


Assuntos
Terapia de Ressincronização Cardíaca , Desfibriladores Implantáveis , Insuficiência Cardíaca , Marca-Passo Artificial , Algoritmos , Insuficiência Cardíaca/terapia , Humanos , Resultado do Tratamento
4.
Heart Rhythm O2 ; 2(3): 262-270, 2021 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-34337577

RESUMO

BACKGROUND: MicroFidelity catheter technology may facilitate voltage-guided ablation by high-resolution electroanatomic mapping (HR-EAM) and precisely targeted energy application. OBJECTIVE: To evaluate the performance of minielectrode (ME) technology for zero-fluoroscopy substrate-guided cavotricuspid isthmus (CTI) ablation. METHODS: Eighty-two patients underwent near zero-fluoroscopy substrate-guided CTI ablation using a nonirrigated large-tip catheter with 3 MEs. The CTI was subdivided into 15 electroanatomic segments. Bipolar voltage maps were compared with ME signals. The outcome was compared with a historic cohort of 92 patients who underwent linear ablation. RESULTS: Compared with linear ablation, the substrate-guided approach was associated with an almost halved ablation duration (336 ± 228 vs 649 ± 409 seconds, P < .001), halved radiofrequency energy applied (14.2 ± 10.6 vs 28.6 ± 19.6 kJ, P < .001), and shorter procedure duration (60.8 ± 33.8 vs 76.3 ± 40.9 minutes, P = .008) limiting the extent of energy delivery to 22.7% of the CTI area. HR-EAM visualized 2.03 ± 0.88 conductive pathways with a diameter of 5.35 ± 1.98 mm. A higher number of ME-detected bundles and a larger channel diameter correlated with increased ablation requirements. In 97.6% of the voltage-guided and 88.0% of the linear procedures, fluoroscopy was not used. CONCLUSION: HR-EAM-based substrate-guided CTI ablation may improve procedural outcome compared with the linear approach. Enhanced identification of discrete conductive pathways correlates with ablation efficacy. The electroanatomic subdivision of the CTI into 15 segments was feasible and may improve the understanding and comparability of anatomic variants and ablation results. Independent of the ablation strategy, modern EAM technology enables safe zero-fluoroscopy procedures in the majority of cases.

5.
Pacing Clin Electrophysiol ; 43(7): 763-767, 2020 07.
Artigo em Inglês | MEDLINE | ID: mdl-32359082

RESUMO

In patients with persistent left superior vena cava (PLSVC), transvenous device implantation for cardiac resynchronization therapy (CRT) may be challenging. We present a complex case with successful, high-density electroanatomic mapping (EAM) guided corrective His bundle pacing (CHBP) following failed CRT upgrade in a patient with PLSVC, congenital heart disease, and pacing-associated heart failure. CHBP restored physiological conduction in left bundle branch block with complete conduction block leading to clinical improvement and cardiac remodeling. The presented case supports the growing evidence that EAM-guided CHBP may be considered a feasible alternative to conventional CRT when venous anatomy is not favorable for left ventricular lead implantation.


Assuntos
Fascículo Atrioventricular/fisiopatologia , Bloqueio de Ramo/terapia , Terapia de Ressincronização Cardíaca/métodos , Mapeamento Epicárdico/métodos , Cardiopatias Congênitas/terapia , Insuficiência Cardíaca/terapia , Veia Cava Superior Esquerda Persistente/terapia , Idoso , Bloqueio de Ramo/fisiopatologia , Feminino , Cardiopatias Congênitas/fisiopatologia , Insuficiência Cardíaca/etiologia , Humanos , Veia Cava Superior Esquerda Persistente/fisiopatologia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...