Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 38
Filtrar
1.
Diagnostics (Basel) ; 14(6)2024 Mar 15.
Artigo em Inglês | MEDLINE | ID: mdl-38535045

RESUMO

OBJECTIVES: The aim of this study was to analyze the extent of dental metal artifacts in virtual monoenergetic (VME) images, as they often compromise image quality by obscuring soft tissue affecting vascular attenuation reducing sensitivity in the detection of dissections. METHODS: Neck photon-counting CT datasets of 50 patients undergoing contrast-enhanced trauma CT were analyzed. Hyperattenuation and hypoattenuation artifacts, muscle with and without artifacts and vessels with and without artifacts were measured at energy levels from 40 keV to 190 keV. The corrected artifact burden, corrected image noise and artifact index were calculated. We also assessed subjective image quality on a Likert-scale. RESULTS: Our study showed a lower artifact burden and less noise in artifact-affected areas above the energy levels of 70 keV for hyperattenuation artifacts (conventional polychromatic CT images 1123 ± 625 HU vs. 70 keV VME 1089 ± 733 HU, p = 0.125) and above of 80 keV for hypoattenuation artifacts (conventional CT images -1166 ± 779 HU vs. 80 keV VME -1170 ± 851 HU, p = 0.927). Vascular structures were less hampered by metal artifacts than muscles (e.g., corrected artifact burden at 40 keV muscle 158 ± 125 HU vs. vessels -63 ± 158 HU p < 0.001), which was also reflected in the subjective image assessment, which showed better ratings at higher keV values and overall better ratings for vascular structures than for the overall artifact burden. CONCLUSIONS: Our research suggests 70 keV might be the best compromise for reducing metal artifacts affecting vascular structures and preventing vascular contrast if solely using VME reconstructions. VME imaging shows only significant effects on the general artifact burden. Vascular structures generally experience fewer metal artifacts than soft tissue due to their greater distance from the teeth, which are a common source of such artifacts.

2.
Diagnostics (Basel) ; 14(6)2024 Mar 15.
Artigo em Inglês | MEDLINE | ID: mdl-38535047

RESUMO

BACKGROUND: Photon-counting detector (PCD) computed tomography (CT) allows for the reconstruction of virtual monoenergetic images (VMI) at different thresholds. OBJECTIVE: The aim of our study was to evaluate the optimal arterial contrast in portal venous (pv) scans regarding objective parameters and subjective image quality for different virtual keV levels. METHODS: We identified 40 patients that underwent a CT scan with an arterial and pv phase on a PCD-CT (NAEOTOM alpha, Siemens Healthineers, Forchheim, Germany). The attenuation of abdominal arteries on pv phases was measured for different virtual keV levels in a monoenergetic+ application profile and for polychromatic (pc) arterial images. Two independent readers assessed subjective image quality, including vascular contrast in pv scans at different energy levels. Additionally, signal- and contrast-to-noise ratios (SNR and CNR) were measured. RESULTS: Our results showed increasing arterial attenuation levels with decreasing energy levels in virtual monoenergetic imaging on pv scans with the highest attenuation at 40 keV, significantly higher than in the pc arterial phase (439 ± 97 HU vs. 360 ± 97, p < 0.001). Noise, SNR, and CNR were worse at this energy level (p < 0.001). Pv VMI showed less noise at energy levels above 70 keV (all p < 0.001). Subjective image quality was rated best at 70 keV, vascular contrast was best at 40 keV. CONCLUSIONS: Our research suggests that virtual monoenergetic images at 40 keV in Mono+ mode derived from a PCD-CT can be a feasible alternative to a true arterial phase for assessment of vessels with worse CNR and SNR.

3.
Dentomaxillofac Radiol ; 53(2): 103-108, 2024 Feb 08.
Artigo em Inglês | MEDLINE | ID: mdl-38330501

RESUMO

PURPOSE: This study investigated the differences in subjective and objective image parameters as well as dose exposure of photon-counting CT (PCCT) compared to cone-beam CT (CBCT) in paranasal sinus imaging for the assessment of rhinosinusitis and sinonasal anatomy. METHODS: This single-centre retrospective study included 100 patients, who underwent either clinically indicated PCCT or CBCT of the paranasal sinus. Two blinded experienced ENT radiologists graded image quality and delineation of specific anatomical structures on a 5-point Likert scale. In addition, contrast-to-noise ratio (CNR) and applied radiation doses were compared among both techniques. RESULTS: Image quality and delineation of bone structures in paranasal sinus PCCT was subjectively rated superior by both readers compared to CBCT (P < .001). CNR was significantly higher for photon-counting CT (P < .001). Mean effective dose for PCCT examinations was significantly lower than for CBCT (0.038 mSv ± 0.009 vs. 0.14 mSv ± 0.011; P < .001). CONCLUSION: In a performance comparison of PCCT and a modern CBCT scanner in paranasal sinus imaging, we demonstrated that first-use PCCT in clinical routine provides higher subjective image quality accompanied by higher CNR at close to a quarter of the dose exposure compared to CBCT.


Assuntos
Seios Paranasais , Tomografia Computadorizada por Raios X , Humanos , Estudos Retrospectivos , Doses de Radiação , Tomografia Computadorizada por Raios X/métodos , Tomografia Computadorizada de Feixe Cônico/métodos , Seios Paranasais/diagnóstico por imagem , Imagens de Fantasmas
4.
Cochlear Implants Int ; : 1-13, 2023 Nov 03.
Artigo em Inglês | MEDLINE | ID: mdl-37922404

RESUMO

Objectives: To propose an automated fast cochlear segmentation, length, and volume estimation method from clinical 3D multimodal images which has a potential role in the choice of cochlear implant type, surgery planning, and robotic surgeries.Methods: Two datasets from different countries were used. These datasets include 219 clinical 3D images of cochlea from 3 modalities: CT, CBCT, and MR. The datasets include different ages, genders, and types of cochlear implants. We propose an atlas-model-based method for cochlear segmentation and measurement based on high-resolution µCT model and A-value. The method was evaluated using 3D landmarks located by two experts.Results: The average error was 0.61±0.22 mm and the average time required to process an image was 5.21±0.93 seconds (P<0.001). The volume of the cochlea ranged from 73.96 mm3 to 106.97 mm3, the cochlear length ranged from 36.69 to 45.91 mm at the lateral wall and from 29.12 to 39.05 mm at the organ of Corti.Discussion: We propose a method that produces nine different automated measurements of the cochlea: volume of scala tympani, volume of scala vestibuli, central lengths of the two scalae, the scala tympani lateral wall length, and the organ of Corti length in addition to three measurements related to A-value.Conclusion: This automatic cochlear image segmentation and analysis method can help clinician process multimodal cochlear images in approximately 5 seconds using a simple computer. The proposed method is publicly available for free download as an extension for 3D Slicer software.

5.
Diagnostics (Basel) ; 13(12)2023 Jun 19.
Artigo em Inglês | MEDLINE | ID: mdl-37371011

RESUMO

This article describes the technical principles and clinical applications of dual-energy computed tomography (DECT) in the context of cardiothoracic imaging with a focus on current developments and techniques. Since the introduction of DECT, different vendors developed distinct hard and software approaches for generating multi-energy datasets and multiple DECT applications that were developed and clinically investigated for different fields of interest. Benefits for various clinical settings, such as oncology, trauma and emergency radiology, as well as musculoskeletal and cardiovascular imaging, were recently reported in the literature. State-of-the-art applications, such as virtual monoenergetic imaging (VMI), material decomposition, perfused blood volume imaging, virtual non-contrast imaging (VNC), plaque removal, and virtual non-calcium (VNCa) imaging, can significantly improve cardiothoracic CT image workflows and have a high potential for improvement of diagnostic accuracy and patient safety.

6.
Diagnostics (Basel) ; 13(10)2023 May 18.
Artigo em Inglês | MEDLINE | ID: mdl-37238274

RESUMO

BACKGROUND: Type 2 diabetes mellitus (DM) is the most common metabolic disorder in the world and an important risk factor for peripheral arterial disease (PAD). CT angiography represents the method of choice for the diagnosis, pre-operative planning, and follow-up of vascular disease. Low-energy dual-energy CT (DECT) virtual mono-energetic imaging (VMI) has been shown to improve image contrast, iodine signal, and may also lead to a reduction in contrast medium dose. In recent years, VMI has been improved with the use of a new algorithm called VMI+, able to obtain the best image contrast with the least possible image noise in low-keV reconstructions. PURPOSE: To evaluate the impact of VMI+ DECT reconstructions on quantitative and qualitative image quality in the evaluation of the lower extremity runoff. MATERIALS AND METHODS: We evaluated DECT angiography of lower extremities in patients suffering from diabetes who had undergone clinically indicated DECT examinations between January 2018 and January 2023. Images were reconstructed with standard linear blending (F_0.5) and low VMI+ series were generated from 40 to 100 keV, in an interval of 15 keV. Vascular attenuation, image noise, signal-to-noise ratio (SNR), and contrast-to-noise ratio (CNR) were calculated for objective analysis. Subjective analysis was performed using five-point scales to evaluate image quality, image noise, and diagnostic assessability of vessel contrast. RESULTS: Our final study cohort consisted of 77 patients (41 males). Attenuation values, CNR, and SNR were higher in 40-keV VMI+ reconstructions compared to the remaining VMI+ and standard F_0.5 series (HU: 1180.41 ± 45.09; SNR: 29.91 ± 0.99; CNR: 28.60 ± 1.03 vs. HU 251.32 ± 7.13; SNR: 13.22 ± 0.44; CNR: 10.57 ± 0.39 in standard F_0.5 series) (p < 0.0001). Subjective image rating was significantly higher in 55-keV VMI+ images compared to the other VMI+ and standard F_0.5 series in terms of image quality (mean score: 4.77), image noise (mean score: 4.39), and assessability of vessel contrast (mean value: 4.57) (p < 0.001). CONCLUSIONS: DECT 40-keV and 55-keV VMI+ showed the highest objective and subjective parameters of image quality, respectively. These specific energy levels for VMI+ reconstructions could be recommended in clinical practice, providing high-quality images with greater diagnostic suitability for the evaluation of lower extremity runoff, and potentially needing a lower amount of contrast medium, which is particularly advantageous for diabetic patients.

7.
Diagnostics (Basel) ; 13(5)2023 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-36900082

RESUMO

PURPOSE: The novel photon-counting detector (PCD) technique acquires spectral data for virtual monoenergetic imaging (VMI) in every examination. The aim of this study was the evaluation of the impact of VMI of abdominal arterial vessels on quantitative and qualitative subjective image parameters. METHODS: A total of 20 patients that underwent an arterial phase computed tomography (CT) scan of the abdomen with a novel PCD CT (Siemens NAEOTOM alpha) were analyzed regarding attenuation at different energy levels in virtual monoenergetic imaging. Contrast-to-noise ratio (CNR) and signal-to-noise ratio (SNR) were calculated and compared between the different virtual monoenergetic (VME) levels with correlation to vessel diameter. In addition, subjective image parameters (overall subjective image quality, subjective image noise and vessel contrast) were evaluated. RESULTS: Our research showed decreasing attenuation levels with increasing energy levels in virtual monoenergetic imaging regardless of vessel diameter. CNR showed best overall results at 60 keV, and SNR at 70 keV with no significant difference to 60 keV (p = 0.294). Subjective image quality was rated best at 70 keV for overall image quality, vessel contrast and noise. CONCLUSIONS: Our data suggest that VMI at 60-70 keV provides the best objective and subjective image quality concerning vessel contrast irrespective of vessel size.

8.
Herz ; 48(1): 55-63, 2023 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-35006290

RESUMO

BACKGROUND: We investigated the feasibility of evaluating coronary arteries with a contrast-enhanced (CE) self-navigated sparse isotropic 3D whole heart T1-weighted magnetic resonance imaging (MRI) study sequence. METHODS: A total of 22 consecutive patients underwent coronary angiography and/or cardiac computed tomography (CT) including cardiac MRI. The image quality was evaluated on a 3-point Likert scale. Inter-reader variability for image quality was analyzed with Cohen's kappa for the main coronary segments (left circumflex [LCX], left anterior descending [LAD], right coronary artery [RCA]) and the left main trunk (LMT). RESULTS: Inter-reader agreement for image quality of the coronary tree ranged from substantial to perfect, with a Cohen's kappa of 0.722 (RCAmid) to 1 (LCXprox). The LMT had the best image quality. Image quality of the proximal vessel segments differed significantly from the mid- and distal segments (RCAprox vs. RCAdist, p < 0.05). The LCX segments showed no significant difference in image quality along the vessel length (LCXprox vs. LCXdist, p = n.s.). The mean acquisition time for the study sequence was 553 s (±46 s). CONCLUSION: Coronary imaging with a sparse 3D whole-heart sequence is feasible in a reasonable amount of time producing good-quality imaging. Image quality was poorer in distal coronary segments and along the entire course of the LCX.


Assuntos
Vasos Coronários , Coração , Humanos , Vasos Coronários/diagnóstico por imagem , Angiografia Coronária , Imageamento por Ressonância Magnética , Imageamento Tridimensional
9.
J Endovasc Ther ; 30(5): 739-745, 2023 10.
Artigo em Inglês | MEDLINE | ID: mdl-35582987

RESUMO

PURPOSE: Endoleaks are a common complication after endovascular aortic repair (EVAR) and thoracic endovascular aortic repair (TEVAR). The detection and correct classification of endoleaks is essential for the further treatment of affected patients. However, standard computed tomography angiography (CTA) provides no hemodynamic information on endoleaks, which can result in misclassification in complex cases. The aim of this study was to compare standard CTA (sCTA) with dynamic, dual-energy CTA (dCTA) for detection and classification of endoleaks following EVAR or TEVAR. MATERIALS AND METHODS: This retrospective evaluation compared 69 sCTA diagnostic examinations performed on 50 different patients with 89 dCTA diagnostic examinations performed on 69 different patients. RESULTS: In total, 15.9% of sCTA examinations and 49.4% of dCTA examinations led to the detection of endoleaks. With sCTA, 20.0% of patients were diagnosed with endoleaks, while with dCTA, 37.7% of patients were diagnosed with endoleaks. With sCTA, mainly Type 1 endoleaks were detected, whereas, with dCTA, the types of detected endoleaks were more evenly distributed. In comparison with the literature, the frequencies of endoleak types detected with dCTA better reflect the natural distribution than the frequencies detected with standard CTA. CONCLUSION: Based on the retrospective comparative evaluation, dCTA could pose a valuable supplementary diagnostic tool resulting in a more accurate and realistic detection and classification of suspected endoleaks.


Assuntos
Aneurisma da Aorta Abdominal , Procedimentos Endovasculares , Humanos , Angiografia por Tomografia Computadorizada/efeitos adversos , Endoleak/diagnóstico por imagem , Endoleak/etiologia , Correção Endovascular de Aneurisma , Meios de Contraste , Estudos Retrospectivos , Aneurisma da Aorta Abdominal/diagnóstico por imagem , Aneurisma da Aorta Abdominal/cirurgia , Aneurisma da Aorta Abdominal/complicações , Resultado do Tratamento , Procedimentos Endovasculares/efeitos adversos , Procedimentos Endovasculares/métodos , Aortografia/métodos
10.
Eur Radiol ; 33(4): 2461-2468, 2023 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-36477938

RESUMO

OBJECTIVES: Photon-counting computed tomography has lately found its way into clinical routine. The new technique could offer substantial improvements regarding general image quality, image noise, and radiation dose reduction. This study evaluated the first abdominal examinations in clinical routine and compared the results to conventional computed tomography. METHODS: In this single-center retrospective study, 66 patients underwent photon-counting and conventional abdominal CT. Four radiologists assessed general image quality, image noise, and image artifacts. Signal-to-noise ratio and dose properties of both techniques within the clinical application were compared. An ex vivo phantom study revealed the radiobiological impact by means of DNA double-strand break foci in peripheral blood cells by enumerating γ-H2AX+53BP1 foci. RESULTS: General image quality in accordance with the Likert scale was found superior for photon-counting CT (4.74 ± 0.46 vs. 4.25 ± 0.54; p < 0.001). Signal-to-noise ratio (p < 0.001) and also dose exposure were higher for photon-counting CT (DLP: 419.2 ± 162.2 vs. 372.3 ± 236.6 mGy*cm; p = 0.0435). CT exposure resulted in significantly increased DNA damage in comparison to sham control (p < 0.001). Investigation of the average foci per cell and radiation-induced foci numbers revealed significantly elevated numbers (p = 0.004 and p < 0.0001, respectively) after photon-counting CT. CONCLUSION: Photon-counting CT in abdominal examinations showed superior results regarding general image quality and signal-to-noise ratio in clinical routine. However, this seems to be traded for a significantly higher dose exposure and corresponding double-strand break frequency. Optimization of standard protocols in further clinical applications is required to find a compromise regarding picture quality and dose exposure. KEY POINTS: • Photon-counting computed tomography promises to enhance the diagnostic potential of medical imaging in clinical routine. • Retrospective single-center study showed superior general image quality accompanied by higher dose exposure in initial abdominal PCCT protocols compared to state-of-the-art conventional CT. • A simultaneous ex vivo phantom study revealed correspondingly increased frequencies of DNA double-strand breaks after PCCT.


Assuntos
DNA , Tomografia Computadorizada por Raios X , Humanos , Estudos Retrospectivos , Doses de Radiação , Tomografia Computadorizada por Raios X/métodos , Razão Sinal-Ruído , Imagens de Fantasmas
11.
Clin Neuroradiol ; 33(2): 427-433, 2023 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-36269346

RESUMO

PURPOSE: Tirofiban has been approved for the treatment of acute coronary syndrome. Meanwhile, tirofiban is frequently applied in emergency situations in interventional neuroradiology (INR). The objective of this study was to analyze the risk profile for the off-label use of tirofiban in INR patients. METHODS: Data of 86 patients, who underwent neurointerventional therapy and were treated with tirofiban at 2 neuroendovascular centers between January 2016 and July 2017 were retrospectively analyzed. Despite off-label use, recent stroke (< 30 days), recent hemorrhage, thrombocytopenia (< 150,000/µl), activated partial thromboplastin time (aPTT) > 1.3-fold, internation normalised ratio (INR) < 1.5, severe liver insufficiency (Child-Pugh C), and preceding intravenous thrombolysis were considered as contraindications. RESULTS: Median patient age was 62 years (range 26-88 years). Patients received tirofiban for extracranial (n = 35) or intracranial stenting (n = 35), coiling of ruptured cerebral aneurysms (n = 6), continuous intra-arterial nimodipine infusion via microcatheters for subarachnoid hemorrhage (SAH)-related vasospasm (n = 5), or thrombotic complications during neuroendovascular procedures (n = 5). The desired effect of preventing thrombotic complications when applying tirofiban off-label was achieved in 81 of 86 patients (94.2%). Relevant tirofiban-associated complications occurred in 14 patients (16.3%), of which 9 patients received i.v. thrombolysis for treatment of acute ischemic stroke shortly before starting therapy with tirofiban. Of the 86 patients 12 died, while the overall tirofiban-related mortality was 2.3% (2 patients died due to ICH). Logistic regression analysis revealed age to be the only parameter significantly associated with development of tirofiban-associated complications (p = 0.026). CONCLUSION: Whereas the safety profile of tirofiban when applied off-label in INR is acceptable, the highest risk for relevant tirofiban-associated complications is observed in older patients treated by emergency stenting for acute stroke.


Assuntos
AVC Isquêmico , Acidente Vascular Cerebral , Humanos , Idoso , Adulto , Pessoa de Meia-Idade , Idoso de 80 Anos ou mais , Tirofibana/efeitos adversos , Uso Off-Label , AVC Isquêmico/tratamento farmacológico , Estudos Retrospectivos , Tirosina , Acidente Vascular Cerebral/diagnóstico por imagem , Acidente Vascular Cerebral/tratamento farmacológico , Resultado do Tratamento , Inibidores da Agregação Plaquetária/efeitos adversos , Fibrinolíticos
12.
Unfallchirurgie (Heidelb) ; 126(10): 779-787, 2023 Oct.
Artigo em Alemão | MEDLINE | ID: mdl-36018349

RESUMO

BACKGROUND: Impaired posttraumatic bone healing is a relevant complication of fractures. Usually, the standard treatment is surgical revision. For about 30 years extracorporeal shockwave therapy (ESWT) has emerged as an alternative treatment option with similar consolidation rates but less complications. OBJECTIVE: This article aims to present our data in context to the current literature MATERIAL AND METHODS: From 2007 to 2016 a total of 97 patients diagnosed with impaired posttraumatic bone healing were treated with ESWT. Clinical and demographic data of this population were retrieved and analyzed retrospectively. RESULTS: The general consolidation rate was 60.8%. Multiple variables were analyzed. A preinterventional bone gap ≥ 5 mm, initial dislocation > ½ of the bone shaft, nicotine consumption and a long time span from fracture to ESWT (> 6 months) were found as factors which significantly impair bone healing after ESWT. CONCLUSION: ESWT is a safe and promising alternative treatment option for delayed unions. Regarding risk factors of a poor outcome may be identified before and increase the rate of success.


Assuntos
Tratamento por Ondas de Choque Extracorpóreas , Fraturas Ósseas , Fraturas não Consolidadas , Humanos , Fraturas não Consolidadas/cirurgia , Resultado do Tratamento , Estudos Retrospectivos , Consolidação da Fratura , Fraturas Ósseas/terapia
13.
Int J Comput Assist Radiol Surg ; 17(10): 1837-1843, 2022 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-35816271

RESUMO

PURPOSE: Cochlea implant surgery with proper positioning of the cochlear electrode can be challenging. Intraoperative real-time hybrid laser-fluoroscopic-guided navigation based on a multiplanar cone beam computed tomography (CBCT) dataset opens up the opportunity to immediate radiological control of primary electrode misalignments and offering new insights into the cochlea electrode insertion routes and favorable cochlear implant-insertion angle. METHODS: In this retrospective study, 50 cases (29 males, 18 females) of conventional electrode implantation (without intraoperative image control; group A) and nine cases (7 males, 2 females) of CBCT-laser-fluoroscopic-guided surgery (group B) were included in the present study. CBCT-laser-guided surgery under real-time fluoroscopic control was conducted using an intraoperative C-arm CBCT. All patients received preoperative cross-sectional imaging (CT and MRI), in which cochlear malformation could be excluded. Postoperatively, we looked for electrode misplacements. RESULTS: In group A, electrode misalignment was detected postoperatively in 14 of 50 cases (28.0%). In group B, primary electrode misalignment was detected intraoperatively in two patients (22.2%). In both patients, the misalignments were corrected in the same session. The comparison of cochlear insertion angles showed significant differences. Group A: 47.5 ± 2.6° (actual conventional surgery) vs 17.6 ± 2.8° (theoretical CBCT-laser-fluoroscopic-guided surgery) P < 0.001. Group A vs group B: 47.5 ± 2.6° (actual conventional surgery; Group A) vs 17.9 ± 2.5° (actual CBCT-laser-fluoroscopic-guided surgery; Group B) P < 0.001. CONCLUSION: We consider that an intraoperative hybrid CBCT-laser-fluoroscopic-controlled approach in cochlear implant surgery using a C-arm CT can be beneficial, because electrode misalignments can be reduced and if it does occur, remedied in the same surgical session.


Assuntos
Implante Coclear , Implantes Cocleares , Cóclea/cirurgia , Implante Coclear/métodos , Tomografia Computadorizada de Feixe Cônico/métodos , Feminino , Humanos , Lasers , Masculino , Estudos Retrospectivos
14.
Tomography ; 8(4): 1642-1648, 2022 06 21.
Artigo em Inglês | MEDLINE | ID: mdl-35894001

RESUMO

Cochlear implants (CIs) are the primary treatment method in patients with profound sensorineural hearing loss. Interpretation of postoperative imaging with conventional energy-integrating detector computed tomography (EID-CT) following CI surgery remains challenging due to metal artifacts. Still, the photon-counting detector (PCD-CT) is a new emerging technology with the potential to eliminate these problems. This study evaluated the performance of virtual monoenergetic (VME) EID-CT images versus PCD-CT in CI imaging. In this cadaveric study, two temporal bone specimens with implanted CIs were scanned with EID-CT and PCD-CT. The images were assessed according to the visibility of interelectrode wire, size of electrode contact, and diameter of halo artifacts. The visibility of interelectrode wire sections was significantly higher when reviewing PCD-CT images. The difference in diameter measurements for electrode contacts between the two CT scanner modalities showed that the PCD-CT technology generally led to significantly larger diameter readings. The larger measurements were closer to the manufacturer's specifications for the CI electrode. The size of halo artifacts surrounding the electrode contacts did not differ significantly between the two imaging modalities. PCT-CT imaging is a promising technology for CI imaging with improved spatial resolution and better visibility of small structures than conventional EID-CT.


Assuntos
Implantes Cocleares , Humanos , Imagens de Fantasmas , Fótons , Tomógrafos Computadorizados , Tomografia Computadorizada por Raios X/métodos
15.
Aerosp Med Hum Perform ; 93(5): 450-457, 2022 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-35551731

RESUMO

INTRODUCTION: With improved imaging technology, the number of incidental findings detected in cerebral MRI is increasing. This is a challenge that the German Air Force has to deal with in the context of standardized MRI examinations of young pilot candidates and pilots.METHODS: The German Air Force Centre of Aerospace Medicine hosted a 2-d conference to develop recommendations and procedures for the handling of some of the most frequently encountered cerebral incidental findings.RESULTS: Radiological MRI findings from a total of 2724 routine examinations of the skull of pilots and pilot applicants (26.8 ± 10.6 yr old; range from 16 to 62; over 80% range from 17 to 33; 96% men) revealed that in 28.1% of the examinations, one or more incidental findings were discovered. For seven of the following categories of incidental findings, decision guidelines could be established: white matter hyperintensities (N = 393; prevalence 14.4%; 95% CI 13.11-15.75), pinealis cysts (317; 11.6%; 10.43-12.84), developmental venous anomalies (64; 2.3%; 1.78-2.92), cavernomas (15; 0.6%; 0.27-0.83), aneurysms (14; 0.5%; 0.25-0.78), cholesterol granulomas (22; 0.8%; 0.47-1.14), and heterotopias of the gray matter (6; 0.2%; 0.04-0.4).CONCLUSION: Considering pilots health and aviation safety, a waiver decision is often possible after thorough discussion, depending on the specific criteria of the incidental finding and of the type of license.Kühn S, Sönksen S-E, Noble H-J, Knopf H, Frischmuth J, Waldeck S, Müller-Forell W, Weber F, Bressem L. Incidental findings in head and brain MRI of military pilots and applicants: consequences for medical flight fitness. Aerosp Med Hum Perform. 2022; 93(5):450-457.


Assuntos
Medicina Aeroespacial , Militares , Pilotos , Encéfalo/diagnóstico por imagem , Feminino , Humanos , Achados Incidentais , Imageamento por Ressonância Magnética , Masculino
16.
Eur J Radiol ; 151: 110283, 2022 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-35390602

RESUMO

PURPOSE: Postoperative imaging following cochlear implant (CI) placement is currently the only means of diagnosing proper electrode position. Manual multiplanar reconstruction (MPR) analysis of CT and CBCT is time-consuming and requires extensive training. This study aims to evaluate the rate of CI misalignment and to determine the amount of time necessary to reach a diagnosis of correct versus incorrect CI placement for readers of different experience levels, using a novel algorithm for image analysis (ACIR) compared to MPR analysis. METHOD: The retrospective single centre study included 333 patients with cochlear implant surgery between May 2002 and May 2021. Postoperative CT and CBCT images were evaluated in three subgroups and the time to diagnosis was documented. Group 1: image evaluation using conventional MPR analysis; group 2: image evaluation by an experienced neuroradiologist via a novel ultra-fast algorithm; group 3: image evaluation by a young specialist via novel ultra-fast algorithm. T-test and Pearson's chi-squared test were used for inter-group comparisons. RESULTS: 333 patients (63.3 ± 15.9 years; 188 men) with 335 CIs were evaluated. The rate of CI misalignment diagnosed from 3D imaging was 14.3% (n = 48). MPR analysis required 255.7 ± 70.4 s per temporal bone, whereas Slicer plugin reduced analysis time to 83.3 ± 7.7 s (p < 0.001) for the experienced reader and 89.6 ± 8.7 s for the young specialist (p < 0.001). CONCLUSION: 3D postoperative imaging reveals high incidences of CI misalignment. Application of a novel ultra-fast algorithm significantly reduces the time for diagnosis compared to MPR analysis for readers of varying experience levels.


Assuntos
Implante Coclear , Implantes Cocleares , Algoritmos , Cóclea , Implante Coclear/métodos , Humanos , Masculino , Estudos Retrospectivos
17.
PLoS One ; 17(3): e0264449, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35235600

RESUMO

BACKGROUND: The postoperative imaging assessment of Cochlear Implant (CI) patients is imperative. The main obstacle is that Magnetic Resonance imaging (MR) is contraindicated or hindered by significant artefacts in most cases with CIs. This study describes an automatic cochlear image registration and fusion method that aims to help radiologists and surgeons to process pre-and postoperative 3D multimodal imaging studies in cochlear implant (CI) patients. METHODS AND FINDINGS: We propose a new registration method, Automatic Cochlea Image Registration (ACIR-v3), which uses a stochastic quasi-Newton optimiser with a mutual information metric to find 3D rigid transform parameters for registration of preoperative and postoperative CI imaging. The method was tested against a clinical cochlear imaging dataset that contains 131 multimodal 3D imaging studies of 41 CI patients with preoperative and postoperative images. The preoperative images were MR, Multidetector Computed Tomography (MDCT) or Cone Beam Computed Tomography (CBCT) while the postoperative were CBCT. The average root mean squared error of ACIR-v3 method was 0.41 mm with a standard deviation of 0.39 mm. The results were evaluated quantitatively using the mean squared error of two 3D landmarks located manually by two neuroradiology experts in each image and compared to other previously known registration methods, e.g. Fast Preconditioner Stochastic Gradient Descent, in terms of accuracy and speed. CONCLUSIONS: Our method, ACIR-v3, produces high resolution images in the postoperative stage and allows for visualisation of the accurate anatomical details of the MRI with the absence of significant metallic artefacts. The method is implemented as an open-source plugin for 3D Slicer tool.


Assuntos
Implante Coclear , Imageamento Tridimensional , Algoritmos , Cóclea/diagnóstico por imagem , Cóclea/cirurgia , Tomografia Computadorizada de Feixe Cônico/métodos , Humanos , Imageamento Tridimensional/métodos , Imageamento por Ressonância Magnética/métodos
18.
J Clin Med ; 11(3)2022 Jan 28.
Artigo em Inglês | MEDLINE | ID: mdl-35160124

RESUMO

BACKGROUND AND PURPOSE: Intracranial aneurysms are commonly treated with balloon-assisted endovascular coiling because the balloon allows for the control und modulation of wide-necked aneurysms and the coil basket. However, this approach might be associated with a higher complication rate. This retrospective study compared the multimodal results between balloon-assisted coiling of aneurysms (group 1) and coiling without balloon assistance (group 2). MATERIALS AND METHODS: We included 67 patients with unruptured intracranial aneurysms in this retrospective analysis; acutely ruptured aneurysms were excluded from the analysis. We divided these patients into two groups and evaluated them for symptomatic thromboembolic complications in the course of intracranial aneurysm treatment. All patients had an intrainterventional neurophysiological monitoring (IINM) and a pre- and postinterventional NIH Stoke Scale (NIHSS) survey and MR imaging. Multiple logistic regression was used to assess whether balloon-assisted coiling increased the rate of thromboembolic complications. Periprocedural aneurysm hemorrhage did not occur in any of the cases. RESULTS: We detected no statistically significant difference in rates of neurophysiological disturbances (19.5% (group 1) versus 34.6% (group 2); p = 0.249). There was no association with age, gender, or aneurysm location. The occurrence of new diffusion-weighted defects was not statistically significantly different (19.5% (group 1) versus 35.0% (group 2); p = 0.166). The difference in NIHSS before and after the intervention showed also no statistical significance in both groups (p = 0.426). CONCLUSION: The use of balloon-assisted coiling did not increase the rate of neurological disturbances during endovascular coiling. MR imaging and NIHSS survey also showed no increased risk of embolization from balloon-assisted aneurysm coiling. IINM is a central aspect of care during endovascular coiling as it can substantially decrease morbidity.

19.
PLoS One ; 17(1): e0262758, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35051221

RESUMO

BACKGROUND AND PURPOSE: The complex anatomy of the temporal bone is difficult to understand and constitutes a challenge in the daily diagnostic routine even for experienced neuroradiologists. In the context of otoneurological (oVEMP) and preoperative diagnostics, the diagnosis of superior semicircular canal dehiscence (SSCD) is of great importance for Ear, Nose, and Throat (ENT) specialists. The gold standard for this diagnosis is a high-resolution CT (HRCT) of the temporal bone. In order to correctly diagnose SSCD, special oblique reconstructions are necessary in addition to standard (axial, coronal, sagittal) reconstructions. We evaluated the frequency of diagnosis and its location in HRCT in correlation with otoneurological examination. From this analysis, we present a new SSCD classification. This classification yields the potential of a differentiated analysis of the patient's clinical symptoms with correlation to the cross-sectional anatomy and may lead to a differentiated therapy approach. STUDY DESIGN AND SETTING: We evaluated 1370 temporal bone scans of patients with residual hearing and verified 343 superior semicircular canal dehiscence (SSCD). We conducted a subgroup analysis of these 343 HRCT scans displaying a SSCD and used them as a basis to create a classification. RESULTS: Three location types of SSCD were identified. These were anterior type 1, superior type 2 and posterior type 3. Type 2 were significantly more frequent in both sexes. SSCD at this location can be overlooked if diagnosis is performed only in the standard axial plane, since it can only be visualized by means of double oblique reconstruction. We present a standardized reconstruction algorithm. CONCLUSION: In total, three types of SSCD with differing incidences can be extrapolated from the locations. Superior type 2 is the most frequent one. Both sexes are affected with roughly equal incidence. The use of standardized double oblique reconstruction algorithm ensures that all three types are diagnosed in the HRCT.


Assuntos
Deiscência do Canal Semicircular/diagnóstico por imagem , Osso Temporal/diagnóstico por imagem , Tomografia Computadorizada por Raios X/métodos , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Criança , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Adulto Jovem
20.
Int J Radiat Biol ; 98(5): 865-872, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-34982640

RESUMO

PURPOSE: Advanced angiographic procedures in interventional radiology are becoming more important and are more frequently used, especially in the treatment of several acute life-threatening diseases like stroke or aortic injury. In recent years, technical advancement has led to a broader spectrum of interventions and complex procedures with longer fluoroscopy times. This involves the risk of higher dose exposures, which, in rare cases, may cause deterministic radiation effects, e.g. erythema in patients undergoing angiographic procedures. Against this background, these procedures recently also became subject to national and international regulations regarding radiation protection. At the same time, individual risk assessment of possible stochastic radiation effects for each patient must be weighed up against the anticipated benefits of the therapy itself. Harmful effects of the administered dose are not limited to the patient but can also affect the radiologist and the medical staff. In particular, the development of cataracts in interventionalists is a rising matter of concern. Furthermore, long-term effects of repeated and prolonged x-ray exposure have long been neglected by radiologists but have come into focus in the past years. CONCLUSIONS: With all this in mind, this review discusses different efforts to reduce radiation exposition levels for patients and medical staff by means of technical, personal as well as organizational measures.


Assuntos
Exposição Ocupacional , Exposição à Radiação , Lesões por Radiação , Proteção Radiológica , Fluoroscopia/efeitos adversos , Fluoroscopia/métodos , Humanos , Exposição Ocupacional/efeitos adversos , Doses de Radiação , Exposição à Radiação/efeitos adversos , Lesões por Radiação/etiologia , Lesões por Radiação/prevenção & controle , Proteção Radiológica/métodos , Radiologia Intervencionista
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...