1.
Ultrasound Med Biol ; 47(9): 2589-2597, 2021 09.
Artigo em Inglês | MEDLINE | ID: mdl-34172339

RESUMO

It is unknown whether and to what extent the penetration depth of lung ultrasound (LUS) influences the accuracy of LUS findings. The current study evaluated and compared the LUS aeration score and two frequently used B-line scores with focal lung aeration assessed by chest computed tomography (CT) at different levels of depth in invasively ventilated intensive care unit (ICU) patients. In this prospective observational study, patients with a clinical indication for chest CT underwent a 12-region LUS examination shortly before CT scanning. LUS images were compared with corresponding regions on the chest CT scan at different subpleural depths. For each LUS image, the LUS aeration score was calculated. LUS images with B-lines were scored as the number of separately spaced B-lines (B-line count score) and the percentage of the screen covered by B-lines divided by 10 (B-line percentage score). The fixed-effect correlation coefficient (ß) was presented per 100 Hounsfield units. A total of 40 patients were included, and 372 regions were analyzed. The best association between the LUS aeration score and CT was found at a subpleural depth of 5 cm for all LUS patterns (ß = 0.30, p < 0.001), 1 cm for A- and B1-patterns (ß = 0.10, p < 0.001), 6 cm for B1- and B2-patterns (ß = 0.11, p < 0.001) and 4 cm for B2- and C-patterns (ß = 0.07, p = 0.001). The B-line percentage score was associated with CT (ß = 0.46, p = 0.001), while the B-line count score was not (ß = 0.07, p = 0.305). In conclusion, the subpleural penetration depth of ultrasound increased with decreased aeration reflected by the LUS pattern. The LUS aeration score and the B-line percentage score accurately reflect lung aeration in ICU patients, but should be interpreted while accounting for the subpleural penetration depth of ultrasound.


Assuntos
Pulmão , Tomografia Computadorizada por Raios X , Cuidados Críticos , Humanos , Unidades de Terapia Intensiva , Pulmão/diagnóstico por imagem , Ultrassonografia
2.
PLoS One ; 13(12): e0204832, 2018.
Artigo em Inglês | MEDLINE | ID: mdl-30540757

RESUMO

INTRODUCTION: Patients with severe malaria or sepsis are at risk of developing life-threatening acute respiratory distress syndrome (ARDS). The objective of this study was to evaluate point-of-care lung ultrasound as a novel tool to determine the prevalence and early signs of ARDS in a resource-limited setting among patients with severe malaria or sepsis. MATERIALS AND METHODS: Serial point-of-care lung ultrasound studies were performed on four consecutive days in a planned sub study of an observational cohort of patients with malaria or sepsis in Bangladesh. We quantified aeration patterns across 12 lung regions. ARDS was defined according to the Kigali Modification of the Berlin Definition. RESULTS: Of 102 patients enrolled, 71 had sepsis and 31 had malaria. Normal lung ultrasound findings were observed in 44 patients on enrolment and associated with 7% case fatality. ARDS was detected in 10 patients on enrolment and associated with 90% case fatality. All patients with ARDS had sepsis, 4 had underlying pneumonia. Two patients developing ARDS during hospitalisation already had reduced aeration patterns on enrolment. The SpO2/FiO2 ratio combined with the number of regions with reduced aeration was a strong prognosticator for mortality in patients with sepsis (AUROC 91.5% (95% Confidence Interval: 84.6%-98.4%)). CONCLUSIONS: This study demonstrates the potential usefulness of point-of-care lung ultrasound to detect lung abnormalities in patients with malaria or sepsis in a resource-constrained hospital setting. LUS was highly feasible and allowed to accurately identify patients at risk of death in a resource limited setting.


Assuntos
Pulmão/diagnóstico por imagem , Malária/diagnóstico por imagem , Sistemas Automatizados de Assistência Junto ao Leito , Síndrome do Desconforto Respiratório/diagnóstico por imagem , Sepse/diagnóstico por imagem , Adulto , Bangladesh , Feminino , Humanos , Masculino , Estudos Prospectivos , Índice de Gravidade de Doença , Ultrassonografia
3.
Crit Care ; 18(4): R137, 2014 Jul 01.
Artigo em Inglês | MEDLINE | ID: mdl-24985156

RESUMO

INTRODUCTION: Neutrophil gelatinase-associated lipocalin (NGAL) has been demonstrated to be a useful early diagnostic biomarker of acute kidney injury (AKI) where the timing of the insult is certain. However, NGAL is not well validated in adult critical care practice because of indeterminate timing of injury. Therefore, we sought to establish the predictive ability of both urine and plasma NGAL to detect AKI in ICU patients. METHOD: This prospective observational study was performed in a busy large district general hospital mixed surgical-medical ICU in Reading, UK. Consecutive adult admissions to the ICU, with absence of chronic kidney disease, renal transplant or AKI as defined by RIFLE criteria were included. Blood and urine specimens were collected at admission and every 24 hours until 72 hours and tested for NGAL. The purpose of the study was to assess whether urinary NGAL (uNGAL) or plasma NGAL (pNGAL) can predict the occurrence of AKI at an earlier point of time than the conventional markers, that is creatinine and urine output as is used in RIFLE criteria. RESULTS: Over a 12-month period, 194 patients were enrolled. In total, 59 (30.4%) patients developed AKI. The admission pNGAL and uNGAL were significantly higher in the patients who developed AKI compared to the non-AKI patients (436 ng/mL (240, 797) versus 168 ng/mL (121.3, 274.3) P <0.001 and 342 ng/mL (61.5, 1,280) versus 34.5 ng/mL (11.5, 107.75) P <0.001 respectively). Hospital mortality was higher in the AKI group (17% versus 4%). Plasma NGAL performed fairly on admission (AUROC 0.77) and thereafter performance improved at 24 and 48 hours (AUROC 0.88 and 0.87) following ICU admission. Urine NGAL had a fair predictive value on admission (AUROC 0.79) and at 24 hours (AUROC 0.78) and was good at 48 hours (AUROC 0.82). CONCLUSIONS: In critically ill patients without pre-existing kidney disease, both pNGAL and uNGAL measured at admission can predict AKI (defined by RIFLE criteria) occurrence up to 72 hours post-ICU admission and their performance (AUROC) was fair. The accuracy of NGAL appeared to improve slightly as patients progressed through their ICU stay. Serial measurements of NGAL (both pNGAL and uNGAL) may be of added value in an ICU setting to predict the occurrence of AKI.


Assuntos
Injúria Renal Aguda/sangue , Injúria Renal Aguda/urina , Proteínas de Fase Aguda/urina , Estado Terminal , Lipocalinas/sangue , Lipocalinas/urina , Proteínas Proto-Oncogênicas/sangue , Proteínas Proto-Oncogênicas/urina , Injúria Renal Aguda/diagnóstico , Adulto , Idoso , Biomarcadores/sangue , Biomarcadores/urina , Feminino , Humanos , Unidades de Terapia Intensiva/tendências , Lipocalina-2 , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos
4.
Crit Care ; 18(2): R58, 2014 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-24690444

RESUMO

INTRODUCTION: Community acquired pneumonia (CAP) is the most common infectious reason for admission to the Intensive Care Unit (ICU). The GenOSept study was designed to determine genetic influences on sepsis outcome. Phenotypic data was recorded using a robust clinical database allowing a contemporary analysis of the clinical characteristics, microbiology, outcomes and independent risk factors in patients with severe CAP admitted to ICUs across Europe. METHODS: Kaplan-Meier analysis was used to determine mortality rates. A Cox Proportional Hazards (PH) model was used to identify variables independently associated with 28-day and six-month mortality. RESULTS: Data from 1166 patients admitted to 102 centres across 17 countries was extracted. Median age was 64 years, 62% were male. Mortality rate at 28 days was 17%, rising to 27% at six months. Streptococcus pneumoniae was the commonest organism isolated (28% of cases) with no organism identified in 36%. Independent risk factors associated with an increased risk of death at six months included APACHE II score (hazard ratio, HR, 1.03; confidence interval, CI, 1.01-1.05), bilateral pulmonary infiltrates (HR1.44; CI 1.11-1.87) and ventilator support (HR 3.04; CI 1.64-5.62). Haematocrit, pH and urine volume on day one were all associated with a worse outcome. CONCLUSIONS: The mortality rate in patients with severe CAP admitted to European ICUs was 27% at six months. Streptococcus pneumoniae was the commonest organism isolated. In many cases the infecting organism was not identified. Ventilator support, the presence of diffuse pulmonary infiltrates, lower haematocrit, urine volume and pH on admission were independent predictors of a worse outcome.


Assuntos
Infecções Comunitárias Adquiridas/epidemiologia , Coleta de Dados , Unidades de Terapia Intensiva , Admissão do Paciente , Pneumonia Bacteriana/epidemiologia , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Estudos de Coortes , Infecções Comunitárias Adquiridas/diagnóstico , Infecções Comunitárias Adquiridas/mortalidade , Europa (Continente)/epidemiologia , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Pneumonia Bacteriana/diagnóstico , Pneumonia Bacteriana/mortalidade , Estudos Prospectivos , Adulto Jovem
5.
Crit Care ; 17(5): 237, 2013 Sep 13.
Artigo em Inglês | MEDLINE | ID: mdl-24041261

RESUMO

The estimation of extra-vascular lung water (EVLW) is an essential component in the assessment of critically ill patients. EVLW is independently associated with mortality and its manipulation has been shown to improve outcome. Accurate assessment of lung water is possible with CT and MR imaging but these are impractical for real-time measurement in sick patients and have been superseded by single thermal dilution techniques. While useful, single thermo-dilution requires repeated calibration and is prone to error, suggesting a need for other monitoring methods. Traditionally the lung was not thought amenable to ultrasound examination owing to the high acoustic impedance of air; however, the identification of artefacts in diseased lung has led to increased use of ultrasound as a point of care investigation for both diagnosis and to monitor response to interventions. Following the initial description of B-lines in association with increased lung water, accumulating evidence has shown that they are a useful and responsive measure of the presence and dynamic changes in EVLW. Animal models have confirmed a correlation with lung gravimetry and the utility of B-lines has been demonstrated in many clinical situations and correlated against other established measures of EVLW. With increasing availability and expertise the role of ultrasound in estimating EVLW should be embedded in clinical practice and incorporated into clinical algorithms to aid decision making. This review looks at the evidence for ultrasound as a valid, easy to use, non-invasive point of care investigation to assess EVLW.


Assuntos
Estado Terminal , Água Extravascular Pulmonar/diagnóstico por imagem , Animais , Estado Terminal/terapia , Humanos , Ultrassonografia
6.
Respirology ; 18(2): 246-54, 2013 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-23039264

RESUMO

Despite 50-60% of intensive care patients demonstrating evidence of pleural effusions, there has been little emphasis placed on the role of effusions in the aetiology of weaning failure. Critical illness and mechanical ventilation lead to multiple perturbations of the normal physiological processes regulating pleural fluid homeostasis, and consequently, failure of normal pleural function occurs. Effusions can lead to deleterious effects on respiratory mechanics and gas exchange, and when extensive, may lead to haemodynamic compromise. The widespread availability of bedside ultrasound has not only facilitated earlier detection of pleural effusions but also safer fluid sampling and drainage. In the majority of patients, pleural drainage leads to improvements in lung function, with data from spontaneously breathing individuals demonstrating a consistent symptomatic improvement, while a meta-analysis in critically ill patients shows an improvement in oxygenation. The effects on respiratory mechanics are less clear, possibly reflecting heterogeneity of underlying pathology. Limited data on clinical outcome from pleural fluid drainage exist; however, it appears to be a safe procedure with a low risk of major complications. The current level of evidence would support a clinical trial to determine whether the systematic detection and drainage of pleural effusions improve clinical outcomes.


Assuntos
Estado Terminal , Unidades de Terapia Intensiva , Derrame Pleural/diagnóstico , Derrame Pleural/terapia , Respiração Artificial , Drenagem/métodos , Humanos , Pulmão/diagnóstico por imagem , Pulmão/fisiopatologia , Mecânica Respiratória , Ultrassonografia , Desmame do Respirador
10.
Crit Care ; 14(4): 227, 2010.
Artigo em Inglês | MEDLINE | ID: mdl-20727227

RESUMO

Sepsis is the systemic inflammatory response to infection and can result in multiple organ dysfunction syndrome with associated high mortality, morbidity and health costs. Erythropoietin is a well-established treatment for the anaemia of renal failure due to its anti-apoptotic effects on red blood cells and their precursors. The extra-haemopoietic actions of erythropoietin include vasopressor, anti-apoptotic, cytoprotective and immunomodulating actions, all of which could prove beneficial in sepsis. Attenuation of organ dysfunction has been shown in several animal models and its vasopressor effects have been well characterised in laboratory and clinical settings. Clinical trials of erythropoietin in single organ disorders have suggested promising cytoprotective effects, and while no randomised trials have been performed in patients with sepsis, good quality data exist from studies on anaemia in critically ill patients, giving useful information of its pharmacokinetics and potential for harm. An observational cohort study examining the microvascular effects of erythropoietin is underway and the evidence would support further phase II and III clinical trials examining this molecule as an adjunctive treatment in sepsis.


Assuntos
Eritropoetina/uso terapêutico , Sepse/tratamento farmacológico , Animais , Apoptose/efeitos dos fármacos , Apoptose/fisiologia , Vasos Sanguíneos/efeitos dos fármacos , Vasos Sanguíneos/fisiopatologia , Eritropoetina/efeitos adversos , Eritropoetina/fisiologia , Humanos , Sepse/complicações , Sepse/fisiopatologia , Síndrome de Resposta Inflamatória Sistêmica/tratamento farmacológico , Síndrome de Resposta Inflamatória Sistêmica/fisiopatologia
11.
Respirology ; 15(6): 986-92, 2010 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-20646244

RESUMO

BACKGROUND AND OBJECTIVE: No consensus exists as to the benefit of pleural drainage in mechanically ventilated patients with conflicting data concerning the effects on gas exchange. We determined the effects on gas exchange over a 48-hour period of draining, by thoracocentesis, large volume pleural effusions. METHODS: A total of 15 thoracocenteses were performed in 10 mechanically ventilated patients with ultrasound evidence of pleural effusions predicted to be greater than 800 mL in volume. Gas exchange, mixed expired CO2, dynamic lung compliance, ventilator settings before procedure and at 30 min, 4, 8, 24 and 48 h were determined. Data were analysed using paired t-tests and repeated-measure anova. RESULTS: Following thoracocentesis there was a 40% increase in the PaO(2) from 82.0 +/- 10.6 mm Hg to 115.2 +/- 31.1 mm Hg (P < 0.05) with a 34% increase in the P:F ratio from 168.9 +/- 55.9 mm Hg to 237.8 +/- 72.6 mm Hg (P < 0.05). These effects were maintained for a period of 48 h. There was a correlation between the amount of fluid drained and the effects on oxygenation with an increase in the PaO(2) of 4 mm Hg for each 100 mL of pleural fluid drained. A-a gradients continued to improve over the course of the study together with a reduction in the dead space fraction and improved dynamic compliance. CONCLUSIONS: Drainage of large pleural effusions in mechanically ventilated patients leads to a significant improvement in gas exchange, and these effects are sustained for 48 h after the procedure supporting a role in the discontinuation of mechanical ventilation.


Assuntos
Oxigênio/sangue , Paracentese , Derrame Pleural/fisiopatologia , Derrame Pleural/terapia , Troca Gasosa Pulmonar , Respiração Artificial , Idoso , Drenagem , Humanos , Pulmão/fisiopatologia , Complacência Pulmonar , Pessoa de Meia-Idade , Derrame Pleural/diagnóstico por imagem , Espaço Morto Respiratório , Ultrassonografia
12.
Circulation ; 109(11): 1434-9, 2004 Mar 23.
Artigo em Inglês | MEDLINE | ID: mdl-15023893

RESUMO

BACKGROUND: Episodes of atrial fibrillation (AF) are known to cause both a rapid reduction in atrial refractoriness (atrial electrical remodeling) and a more delayed increase in AF stability thought to be due to a so-called "second factor." The aim of this study was to quantify the effects and time course of such a factor on AF stability in the chronic goat model. METHODS AND RESULTS: AF was maintained in 6 goats by burst atrial pacing for 3 consecutive 4-week periods separated a mean of 6+/-2.1 days of sinus rhythm. Six days of sinus rhythm was just sufficient for refractoriness changes to reverse fully in all goats. Atrial effective refractory period, AF inducibility, and duration of individual episodes of AF were assessed at regular intervals. There was a progressive reduction from month 1 to 2 to 3 in the mean duration of burst pacing required to induce individual episodes of AF of 60 seconds (178+/-251, 110+/-102, and 21+/-30 hours), 1 hour (229+/-224, 136+/-104, and 68+/-51 hours), and 24 hours (277+/-218, 192+/-190, and 102+/-75 hours; P<0.03). The frequency with which AF was induced during extrastimulus pacing increased progressively from 16.7% in month 1 to 31.7% in month 2 and 46.9% in month 3 (P<0.001). CONCLUSIONS: Sequential 4-week periods of atrial fibrillation result in a progressive increase in AF stability independent of baseline atrial refractory period. This finding suggests the presence of a second factor in the self-perpetuation of AF with a time course comparable to that of AF-induced ultrastructural changes in the atria.


Assuntos
Fibrilação Atrial/fisiopatologia , Animais , Fibrilação Atrial/patologia , Estimulação Cardíaca Artificial , Progressão da Doença , Feminino , Cabras , Átrios do Coração/fisiopatologia , Átrios do Coração/ultraestrutura , Sistema de Condução Cardíaco/fisiopatologia , Modelos Animais , Modelos Cardiovasculares , Periodicidade , Recidiva , Especificidade da Espécie
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...