1.
Dose Response ; 22(1): 15593258231225914, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38204760
2.
Strahlenther Onkol ; 198(9): 849-861, 2022 09.
Artigo em Inglês | MEDLINE | ID: mdl-35732919

RESUMO

BACKGROUND: The gamma index and dose-volume histogram (DVH)-based patient-specific quality assurance (QA) measures commonly applied in radiotherapy planning are unable to simultaneously deliver detailed locations and magnitudes of discrepancy between isodoses of planned and delivered dose distributions. By exploiting statistical classification performance measures such as sensitivity or specificity, compliance between a planned and delivered isodose may be evaluated locally, both for organs-at-risk (OAR) and the planning target volume (PTV), at any specified isodose level. Thus, a patient-specific QA tool may be developed to supplement those presently available in clinical radiotherapy. MATERIALS AND METHODS: A method was developed to locally establish and report dose delivery errors in three-dimensional (3D) isodoses of planned (reference) and delivered (evaluated) dose distributions simultaneously as a function the dose level and of spatial location. At any given isodose level, the total volume of delivered dose containing the reference and the evaluated isodoses is locally decomposed into four subregions: true positive-subregions within both reference and evaluated isodoses, true negative-outside of both of these isodoses, false positive-inside the evaluated isodose but not the reference isodose, and false negatives-inside the reference isodose but not the evaluated isodose. Such subregions may be established over the whole volume of delivered dose. This decomposition allows the construction of a confusion matrix and calculation of various indices to quantify the discrepancies between the selected planned and delivered isodose distributions, over the complete range of values of dose delivered. The 3D projection and visualization of the spatial distribution of these discrepancies facilitates the application of the developed method in clinical practice. RESULTS: Several clinical photon radiotherapy plans were analyzed using the developed method. In some plans at certain isodose levels, dose delivery errors were found at anatomically significant locations. These errors were not otherwise highlighted-neither by gamma analysis nor by DVH-based QA measures. A specially developed 3D projection tool to visualize the spatial distribution of such errors against anatomical features of the patient aids in the proposed analysis of therapy plans. CONCLUSIONS: The proposed method is able to spatially locate delivery errors at selected isodose levels and may supplement the presently applied gamma analysis and DVH-based QA measures in patient-specific radiotherapy planning.


Assuntos
Planejamento da Radioterapia Assistida por Computador , Radioterapia de Intensidade Modulada , Humanos , Órgãos em Risco , Dosagem Radioterapêutica , Planejamento da Radioterapia Assistida por Computador/métodos , Radioterapia de Intensidade Modulada/métodos
5.
Med Phys ; 48(9): 4743-4753, 2021 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-34342005

RESUMO

PURPOSE: The quality of a measured distribution of dose delivered against its corresponding radiotherapy plan is routinely assessed by gamma index (GI) and dose-volume histogram (DVH) metrics. Any correlation between error detection rates, as based on either of these approaches, while argued, has never been convincingly demonstrated. The dependence of the strength of correlation between the GI passing rate ( γ P ) and DVH quality assurance (QA) metrics on various elements of the therapy plan has not been systematically investigated. METHODS: A formal analysis of the relation between γ P and DVH metrics has been undertaken, leading to a relationship which may partly approximate γ P with respect to the DVH. This relationship was further validated by studying examples of simulated clinical radiotherapy plans and by studying the correlation between γ P and the derived relationship using a simple two-dimensional representations of the planning target volume (PTV) and organs at risk (OAR), where penumbra regions, distance-to-agreement tolerances and dose delivery errors were systematically varied. RESULTS: It is shown formally that there cannot be any correlation between γ P and other commonly applied DVH-derived QA measures. However, γ P may be partly approximated given the planned and measured DVH. The derived γ P approximation (the " γ -slope indicator") may be clinically useful in some practical cases of radiotherapy plan QA. CONCLUSIONS: In formal terms, there cannot be any correlation between γ P and any common DVH-calculated patient-specific measures, with respect to PTV or OAR. However, as demonstrated analytically and further confirmed in our simulation studies, the γ P approximation derived in this study (the " γ -slope indicator") may in some cases offer a degree of correlation between γ P and the PTV and OAR DVH QA metrics in measured and planned patient-specific dose distributions-which may be potentially useful in clinical practice.


Assuntos
Benchmarking , Radioterapia de Intensidade Modulada , Humanos , Órgãos em Risco , Dosagem Radioterapêutica , Planejamento da Radioterapia Assistida por Computador
6.
Radiat Oncol ; 16(1): 124, 2021 Jun 29.
Artigo em Inglês | MEDLINE | ID: mdl-34187495

RESUMO

BACKGROUND: Any Monte Carlo simulation of dose delivery using medical accelerator-generated megavolt photon beams begins by simulating electrons of the primary electron beam interacting with a target. Because the electron beam characteristics of any single accelerator are unique and generally unknown, an appropriate model of an electron beam must be assumed before MC simulations can be run. The purpose of the present study is to develop a flexible framework with suitable regression models for estimating parameters of the model of primary electron beam in simulators of medical linear accelerators using real reference dose profiles measured in a water phantom. METHODS: All simulations were run using PRIMO MC simulator. Two regression models for estimating the parameters of the simulated primary electron beam, both based on machine learning, were developed. The first model applies Principal Component Analysis to measured dose profiles in order to extract principal features of the shapes of the these profiles. The PCA-obtained features are then used by Support Vector Regressors to estimate the parameters of the model of the electron beam. The second model, based on deep learning, consists of a set of encoders processing measured dose profiles, followed by a sequence of fully connected layers acting together, which solve the regression problem of estimating values of the electron beam parameters directly from the measured dose profiles. Results of the regression are then used to reconstruct the dose profiles based on the PCA model. Agreement between the measured and reconstructed profiles can be further improved by an optimization procedure resulting in the final estimates of the parameters of the model of the primary electron beam. These final estimates are then used to determine dose profiles in MC simulations. RESULTS: Analysed were a set of actually measured (real) dose profiles of 6 MV beams from a real Varian 2300 C/D accelerator, a set of simulated training profiles, and a separate set of simulated testing profiles, both generated for a range of parameters of the primary electron beam of the Varian 2300 C/D PRIMO simulator. Application of the two-stage procedure based on regression followed by reconstruction-based minimization of the difference between measured (real) and reconstructed profiles resulted in achieving consistent estimates of electron beam parameters and in a very good agreement between the measured and simulated photon beam profiles. CONCLUSIONS: The proposed framework is a readily applicable and customizable tool which may be applied in tuning virtual primary electron beams of Monte Carlo simulators of linear accelerators. The codes, training and test data, together with readout procedures, are freely available at the site: https://github.com/taborzbislaw/DeepBeam .


Assuntos
Aprendizado de Máquina , Planejamento da Radioterapia Assistida por Computador/métodos , Software , Simulação por Computador , Elétrons , Humanos , Modelos Estatísticos , Método de Monte Carlo , Aceleradores de Partículas , Imagens de Fantasmas , Fótons , Análise de Componente Principal , Dosagem Radioterapêutica , Análise de Regressão
7.
Dose Response ; 19(2): 15593258211009337, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34035781

RESUMO

Three statistical methods: Bayesian, randomized data binning and Maximum Entropy Method (MEM) are described and applied in the analysis of US radon data taken from the US registry. Two confounding factors-elevation of inhabited dwellings, and UVB (ultra-violet B) radiation exposure-were considered to be most correlated with the frequency of lung cancer occurrence. MEM was found to be particularly useful in extracting meaningful results from epidemiology data containing such confounding factors. In model testing, MEM proved to be more effective than the least-squares method (even via Bayesian analysis) or multi-parameter analysis, routinely applied in epidemiology. Our analysis of the available residential radon epidemiology data consistently demonstrates that the relative number of lung cancers decreases with increasing radon concentrations up to about 200 Bq/m3, also decreasing with increasing altitude at which inhabitants live. Correlation between UVB intensity and lung cancer has also been demonstrated.

8.
Radiat Prot Dosimetry ; 183(1-2): 251-254, 2019 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-30566667

RESUMO

Radiotherapy beams of protons or heavier ions generate secondary particles through nuclear interactions over different patient tissues. The resulting particle spectra depend on the tissue composition and on charge and energy of the primary beam ions. In proton radiotherapy, predictive radiobiological models usually apply dose-averaged linear energy transfer (LET). Microdosimetry-based models for proton or heavier ion primary beams also rely on dose-averaged quantities, the values of which depend on whether the produced secondaries are included or excluded in the calculation. In turn, this will affect the results of calculations of the relative biological effectiveness (RBE) of these beams. In this brief note, we study quantitatively the influence of the secondary radiation spectra on the averaged expectation values of LET and their impact on predictions of RBE. It is noted that for microdosimetry-based quantities and for corresponding LET-based parameters the trends are similar and that fluence-averaged quantities should be studied more closely.


Assuntos
Terapia com Prótons/métodos , Radiometria/métodos , Eficiência Biológica Relativa , Relação Dose-Resposta à Radiação , Íons Pesados , Humanos , Transferência Linear de Energia , Radiobiologia , Dosagem Radioterapêutica
9.
Med Phys ; 45(1): 391-401, 2018 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-29131351

RESUMO

PURPOSE: To evaluate the effect on charge collection in the ionization chamber (IC) in proton pencil beam scanning (PBS), where the local dose rate may exceed the dose rates encountered in conventional MV therapy by up to three orders of magnitude. METHODS: We measured values of the ion recombination (ks ) and polarity (kpol ) correction factors in water, for a plane-parallel Markus TM23343 IC, using the cyclotron-based Proteus-235 therapy system with an active proton PBS of energies 30-230 MeV. Values of ks were determined from extrapolation of the saturation curve and the Two-Voltage Method (TVM), for planar fields. We compared our experimental results with those obtained from theoretical calculations. The PBS dose rates were estimated by combining direct IC measurements with results of simulations performed using the FLUKA MC code. Values of ks were also determined by the TVM for uniformly irradiated volumes over different ranges and modulation depths of the proton PBS, with or without range shifter. RESULTS: By measuring charge collection efficiency versus applied IC voltage, we confirmed that, with respect to ion recombination, our proton PBS represents a continuous beam. For a given chamber parameter, e.g., nominal voltage, the value of ks depends on the energy and the dose rate of the proton PBS, reaching c. 0.5% for the TVM, at the dose rate of 13.4 Gy/s. For uniformly irradiated regular volumes, the ks value was significantly smaller, within 0.2% or 0.3% for irradiations with or without range shifter, respectively. Within measurement uncertainty, the average value of kpol , for the Markus TM23343 IC, was close to unity over the whole investigated range of clinical proton beam energies. CONCLUSION: While no polarity effect was observed for the Markus TM23343 IC in our pencil scanning proton beam system, the effect of volume recombination cannot be ignored.


Assuntos
Terapia com Prótons , Radiometria/métodos , Simulação por Computador , Ciclotrons , Método de Monte Carlo , Terapia com Prótons/métodos , Água
10.
Int J Hyperthermia ; 31(5): 568-73, 2015.
Artigo em Inglês | MEDLINE | ID: mdl-25885417

RESUMO

PURPOSE: In this prospective preliminary study we evaluated changes of prostate volume and changes of brachytherapy treatment plan parameters due to interstitial hyperthermia (IHT) applied prior to high-dose-rate brachytherapy (HDRBT), compared to our standard HDRBT procedure. MATERIAL AND METHODS: In a group of 60 consecutive patients with prostate adenocarcinoma, 30 were treated with HDRBT alone and 30 with IHT preceding HDRBT. Prior to catheter implantation, a 'virtual' treatment plan (VP) was complied, a 'live' plan (LP) was prepared before patient irradiation, and a 'post' plan (PP) was drawn up after completing the irradiation procedure. In each plan, based on transrectal ultrasound images, the contours of the prostate, urethra, and rectum were delineated and the respective volumes and dose-volume histogram parameters were evaluated. These parameters, established for the LP, were then compared with those of the PP. RESULTS: Changes in prostate volume and in parameters of the treatment plans were observed, but differences between the two patient groups were not statistically significant. For all 60 patients treated, the average prostate volume in the VP was 32 cm(3), in the LP 41 cm(3), and the PP 43 cm(3). Average values of relative changes in the therapy planning parameters between LP and PP were for the prostate D90 -5.7%, V100 -5.6%, V200 -13.2%, for the urethra D0, 1 cm(3) -1.6%, and for rectum D2 cm(3) 0%. CONCLUSION: Hyperthermia prior to HDRBT does not significantly change the volume of the prostate and there is no need to perform the new treatment plan after the hyperthermia session.


Assuntos
Próstata/patologia , Neoplasias da Próstata/radioterapia , Braquiterapia/métodos , Humanos , Masculino , Micro-Ondas , Estudos Prospectivos , Neoplasias da Próstata/patologia , Radiometria , Dosagem Radioterapêutica
11.
Radiother Oncol ; 103(1): 103-8, 2012 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-22444243

RESUMO

INTRODUCTION: In 2007 ESTRO proposed a revision and harmonisation of the core curricula for radiation oncologists, medical physicists and RTTs to encourage harmonised education programmes for the professional disciplines, to facilitate mobility between EU member states, to reflect the rapid development of the professions and to secure the best evidence-based education across Europe. MATERIAL AND METHODS: Working parties for each core curriculum were established and included a broad representation with geographic spread and different experience with education from the ESTRO Educational Committee, local representatives appointed by the National Societies and support from ESTRO staff. RESULTS: The revised curricula have been presented for the ESTRO community and endorsement is ongoing. All three curricula have been changed to competency based education and training, teaching methodology and assessment and include the recent introduction of the new dose planning and delivery techniques and the integration of drugs and radiation. The curricula can be downloaded at http://www.estro-education.org/europeantraining/Pages/EuropeanCurricula.aspx. CONCLUSION: The main objective of the ESTRO core curricula is to update and harmonise training of the radiation oncologists, medical physicists and RTTs in Europe. It is recommended that the authorities in charge of the respective training programmes throughout Europe harmonise their own curricula according to the common framework.


Assuntos
Currículo , Física , Radioterapia (Especialidade)/educação , Radioterapia , Europa (Continente) , Humanos , Neoplasias/radioterapia , Sociedades Médicas
13.
Int J Radiat Biol ; 85(12): 1101-13, 2009 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-19995236

RESUMO

PURPOSE: To study track structure effects in cells irradiated by heavy ions, we have performed a model analysis of an extensive recently published data set of over 40 survival curves of normal human skin fibroblast cells irradiated in vitro by energetic carbon, neon, silicon and iron ions measured in track-segment conditions. MATERIALS AND METHODS: Having derived the required track-segment descriptions of the ion bombardments from the published data, we fitted four parameters of the cellular track structure theory (Katz model) to the whole data set. RESULTS: Using track structure calculations with the best-fitted parameters, we demonstrate a systematic interpretation of this data set, highlighting effects specific to track structure. In particular, we model the dependence of relative biological effectiveness (RBE) and 'single-particle' and 'extrapolated' cross section on linear energy transfer (LET) or Z*(2)/beta(2) (where Z* is the effective charge and beta is the relative velocity of the ion) and demonstrate the predictive capability of the model. CONCLUSIONS: Our interpretation of the data differs from that of Tsuruoka et al. We suggest that the biological effects of charged secondary particles generated in this experiment by degrading the energy of the primary ion beams using polymethyl methacrylate (PMMA) absorbers cannot be ignored.


Assuntos
Fibroblastos/citologia , Fibroblastos/efeitos da radiação , Íons Pesados , Pele/citologia , Morte Celular/efeitos da radiação , Linhagem Celular , Sobrevivência Celular/efeitos da radiação , Relação Dose-Resposta à Radiação , Humanos , Transferência Linear de Energia , Modelos Biológicos , Polimetil Metacrilato/química , Eficiência Biológica Relativa
14.
Radiother Oncol ; 73 Suppl 2: S173-5, 2004 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-15971337

RESUMO

Sets of four parameters (m, E0, sigma0 and kappa) of the cellular track structure model of Katz have been fitted to recently published data concerning human melanoma (AA) and mammalian (V79) cells exposed to a variety of lighter ions and to mixed ion-Co60 and ion-ion irradiation. Using these parameters, model predictions of V79 survival were verified against experimental data. RBE-LET dependences were calculated and compared with experimental data obtained for V79 cells after exposure to 3He, 12C and 20Ne ion beams. The presented track-segment approach used in track structure calculations, while satisfactory for heavier ions, may be of limited value for predicting the RBE-LET dependence of proton and helium radiotherapy beams in regions close to the distal range of these particles. We discuss the predictive capability of this model and propose standards in reporting cellular radiobiology data for application in modelling heavy ion beam radiotherapy.


Assuntos
Radioterapia com Íons Pesados , Transferência Linear de Energia , Eficiência Biológica Relativa , Humanos , Modelos Teóricos
15.
J Radiol Prot ; 22(3A): A159-61, 2002 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-12400966

RESUMO

In 1967 Subcommittee M-4 of the National Commission on Radiation Protection proposed a system for evaluating, summing and reporting occupational exposures. It appears that some 30 years later these concepts could be implemented in a system of radiation protection based on Katz's cellular track structure model, which is able to quantify and predict the response of systems relevant to radiation protection, such as survival or oncogenic transformations in cell cultures, enzymes, bacteria or whole organisms. As a consequence of this approach, an m-power-law (with m ranging between 2 and 3.5) dependence of effect, or radiation risk, after doses of standard Co-60 radiation, would follow.


Assuntos
Exposição Ocupacional/normas , Proteção Radiológica/normas , Poluentes Radioativos , Modificador do Efeito Epidemiológico , Humanos , Modelos Teóricos , Modelos de Riscos Proporcionais , Doses de Radiação , Risco
16.
J Radiat Res ; 43 Suppl: S59-62, 2002 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-12793731

RESUMO

Lithium fluoride thermoluminescence (TL) detectors, with different Li composition (Li-6 and Li-7) and various activators (LiF:Mg,Ti, LiF:Mg,Cu,P), are widely used for dosimetry in space. The primary radiation field in space is composed of fast electrons, protons and heavy charged particles (HCP). By its interaction with the structures of the spacecraft, this field may be modified inside the crew cabin. Therefore, calibration of TL detectors against a dose of gamma-rays is not sufficient for relating the TL readout to absorbed dose or to quantities relevant in radiation protection, without suitable correction. We introduce and calculate the detection efficiency, eta, relative to gamma-ray dose, of lithium fluoride detectors after proton and heavy charged particle (HCP) irradiation. We calculate eta for MCP-N (LiF:Mg,Cu,P) and for MTS-N (LiF:Mg,Ti) using microdosimetric models. The microdosimetric distributions used in these models (for HCP of charges between Z=1 to Z=8 and in the energy range between 0.3 MeV/amu and 20 MeV/amu) are calculated using an analytical model, based on the results of Monte Carlo simulated charged particle tracks using the MOCA-14 code. The ratio etaMCP-N/etaMTS-N for protons of stopping power (in water) below 10 keV/microm lies in the range between 0.65 and 1.0 and for HCP with Z>1--between 0.3 and 0.6. The stopping power of the particle is found not to be a unique parameter to scale the response of TL detectors. The combination of response of LiF:Mg,Cu,P and LiF:Mg,Cu,P detectors can be more suitable for a dose correction in space radiation fields.


Assuntos
Radiação Cósmica , Transferência Linear de Energia , Modelos Teóricos , Dosimetria Termoluminescente , Simulação por Computador , Meio Ambiente Extraterreno , Método de Monte Carlo , Dosimetria Termoluminescente/instrumentação