Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
1.
J Diabetes Sci Technol ; 8(5): 1042-7, 2014 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-24876453

RESUMO

Glycemic variability (GV) is correlated with oxidative stress which may lead to increased cardiovascular risk and poor clinical outcomes in people with prediabetes and diabetes. We sought to understand whether morbidly obese persons without diabetes by standard criteria have dysglycemia as measured by GV. We performed an observational study of GV metrics and carotid intima media thickness (CIMT) in 21 morbidly obese normoglycemic and 15 morbidly obese prediabetic applicants to The Biggest Loser television show. The results were compared to previously published studies in normoglycemic nonobese and obese individuals. Glucose was measured with a masked continuous glucose monitor (CGM) over 3 to 8 days and carotid intima media thickness (CIMT) was determined by ultrasound. CGM-derived GV metrics for GV were coefficient of variation (CV), standard deviation (SD), mean amplitude of glycemic excursions (MAGE), continuous overall net glycemic action-1 hour (CONGA1), and mean of daily differences (MODD). We found that morbidly obese subjects (n = 21) who were normoglycemic by standard criteria had higher GV (CV = 22%, SD = 24.2 mg/dl and MAGE = 48.6 mg/dl) than previous reports of normoglycemic, nonobese individuals (CV = 12-18%, SD = 11.5-15.0 mg/dl, and MAGE = 26.3-28.3 mg/dl). Morbidly obese prediabetic subjects (n = 15) had GV metrics indistinguishable from those morbidly obese subjects who were normoglycemic. CIMT was higher in both morbidly obese groups compared with historical age- and sex-matched controls. Normoglycemic and prediabetic morbidly obese individuals have higher GV compared with normal weight, nondiabetic individuals. We speculate that this may increase the risk for macrovascular disease through excessive oxidative stress.


Assuntos
Glicemia/análise , Obesidade Mórbida/sangue , Adulto , Automonitorização da Glicemia , Espessura Intima-Media Carotídea , Feminino , Humanos , Masculino , Obesidade Mórbida/patologia
2.
Diabetes Care ; 36(4): 786-92, 2013 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-23172975

RESUMO

OBJECTIVE: To characterize glucose response patterns of people who wore a real-time continuous glucose monitor (RT-CGM) as an intervention to improve glycemic control. Participants had type 2 diabetes, were not taking prandial insulin, and interpreted the RT-CGM data independently. RESEARCH DESIGN AND METHODS: Data were from the first 12 weeks of a 52-week, prospective, randomized trial comparing RT-CGM (n = 50) with self-monitoring of blood glucose (n = 50). RT-CGM was used in 8 of the first 12 weeks. A1C was collected at baseline and quarterly. This analysis included 45 participants who wore the RT-CGM ≥4 weeks. Analyses examined the RT-CGM data for common response patterns-a novel approach in this area of research. It then used multilevel models for longitudinal data, regression, and nonparametric methods to compare the patterns of A1C, mean glucose, glycemic variability, and views per day of the RT-CGM device. RESULTS: There were five patterns. For four patterns, mean glucose was lower than expected as of the first RT-CGM cycle of use given participants' baseline A1C. We named them favorable response but with high and variable glucose (n = 7); tight control (n = 14); worsening glycemia (n = 6); and incremental improvement (n = 11). The fifth was no response (n = 7). A1C, mean glucose, glycemic variability, and views per day differed across patterns at baseline and longitudinally. CONCLUSIONS: The patterns identified suggest that targeting people with higher starting A1Cs, using it short-term (e.g., 2 weeks), and monitoring for worsening glycemia that might be the result of burnout may be the best approach to using RT-CGM in people with type 2 diabetes not taking prandial insulin.


Assuntos
Automonitorização da Glicemia/métodos , Diabetes Mellitus Tipo 2/sangue , Idoso , Glicemia/metabolismo , Feminino , Hemoglobinas Glicadas/metabolismo , Humanos , Masculino , Pessoa de Meia-Idade
3.
J Diabetes Sci Technol ; 6(2): 310-9, 2012 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-22538140

RESUMO

BACKGROUND: This study examined whether mobile phone-based, one-way video messages about diabetes self-care improve hemoglobin A1c (A1C) and self-monitoring of blood glucose (SMBG). METHODS: This was a 1-year prospective randomized trial with two groups. The active intervention lasted 6 months. The study enrolled 65 people with A1C >8.0% who were established (>6 months) patients in the endocrinology clinics of the Walter Reed Health Care System. Participants were randomized to receive "usual care" or self-care video messages from their diabetes nurse practitioner. Video messages were sent daily to cell phones of study participants. Hemoglobin A1c and SMBG data were collected at 0, 3, 6, 9, and 12 months. RESULTS: Participants who received the messages had a larger rate of decline in A1C than people who received usual care (0.2% difference over 12 months, adjusting for covariates; p = .002 and p = .004 for the interaction between time and group and for the quadratic effect of time by group, respectively). Hemoglobin A1c decline was greatest among participants who received video messages and viewed >10 a month (0.6% difference over 12 months, adjusting for covariates; p < .001 for the interaction between time and group and the quadratic effect). Self-monitoring of blood glucose metrics were not related to the intervention. CONCLUSIONS: A one-way intervention using mobile phone-based video messages about diabetes self-care can improve A1C. Engagement with the technology is an important predictor of its success. This intervention is simple to implement and sustain.


Assuntos
Automonitorização da Glicemia , Glicemia/metabolismo , Telefone Celular , Diabetes Mellitus/terapia , Hemoglobinas Glicadas/metabolismo , Conhecimentos, Atitudes e Prática em Saúde , Educação de Pacientes como Assunto , Gravação em Vídeo , Idoso , Biomarcadores/sangue , Automonitorização da Glicemia/enfermagem , Distribuição de Qui-Quadrado , Diabetes Mellitus/sangue , Diabetes Mellitus/diagnóstico , Feminino , Humanos , Masculino , Maryland , Pessoa de Meia-Idade , Profissionais de Enfermagem , Estudos Prospectivos , Comportamento de Redução do Risco , Fatores de Tempo , Resultado do Tratamento
4.
Diabetes Care ; 35(1): 32-8, 2012 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-22100963

RESUMO

OBJECTIVE: To determine whether short-time, real-time continuous glucose monitoring (RT-CGM) has long-term salutary glycemic effects in patients with type 2 diabetes who are not on prandial insulin. RESEARCH DESIGN AND METHODS: This was a randomized controlled trial of 100 adults with type 2 diabetes who were not on prandial insulin. This study compared the effects of 12 weeks of intermittent RT-CGM with self-monitoring of blood glucose (SMBG) on glycemic control over a 40-week follow-up period. Subjects received diabetes care from their regular provider without therapeutic intervention from the study team. RESULTS: There was a significant difference in A1C at the end of the 3-month active intervention that was sustained during the follow-up period. The mean, unadjusted A1C decreased by 1.0, 1.2, 0.8, and 0.8% in the RT-CGM group vs. 0.5, 0.5, 0.5, and 0.2% in the SMBG group at 12, 24, 38, and 52 weeks, respectively (P = 0.04). There was a significantly greater decline in A1C over the course of the study for the RT-CGM group than for the SMBG group, after adjusting for covariates (P < 0.0001). The subjects who used RT-CGM per protocol (≥48 days) improved the most (P < 0.0001). The improvement in the RT-CGM group occurred without a greater intensification of medication compared with those in the SMBG group. CONCLUSIONS: Subjects with type 2 diabetes not on prandial insulin who used RT-CGM intermittently for 12 weeks significantly improved glycemic control at 12 weeks and sustained the improvement without RT-CGM during the 40-week follow-up period, compared with those who used only SMBG.


Assuntos
Automonitorização da Glicemia/métodos , Glicemia/metabolismo , Diabetes Mellitus Tipo 2/sangue , Hemoglobinas Glicadas/metabolismo , Monitorização Fisiológica/métodos , Adulto , Idoso , Idoso de 80 Anos ou mais , Sistemas Computacionais , Diabetes Mellitus Tipo 2/fisiopatologia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Redução de Peso
5.
Artigo em Chinês | WPRIM (Pacífico Ocidental) | ID: wpr-789552

RESUMO

BACKGROUND: Numerous medical conditions require timely medication administration in the emergency department (ED). Automated dispensing systems (ADSs) store premixed common doses at the point-of-care to minimize time to administration, but the use of such automation to improved time to medication administration has not been studied. Since vancomycin is a commonly used empiric antimicrobial, we sought to quantify the effect of using an ADS on time to drug delivery in patients presenting to the ED. The study aimed to determine the efficacy of utilizing an ADS to improve time to administration of vancomycin and determine any negative effects on dosing appropriateness.METHODS: The institional review board approved the retrospective quality improvement study took place in a single, urban academic tertiary care ED with an annual census of 80000. Study subjects were all patients receiving vancomycin for the management of sepsis between March 1 to September 30, 2008 and the same time period in 2009. The primary outcome was the proportion of patients who received vancomycin within one hour of bed placement and the secondary outcome was dosing appropriateness.RESULTS: Sixty-three patients had weight and dosing information available (29 before and 34 after intervention) and were included in the study. Before intervention, no patient received vancomycin in less than 60 minutes, while after intervention 14.7% of the patients received it in less than 60 minutes (difference in proportions 14.7%, 95% CI 0.39%-30.0%, P=0.04). A similar proportion of the patients received correct dosing before and after intervention (44.8% vs. 41.2%, difference in proportions 3.7%, 95% CI -20.0%-26.7%, P=0.770).CONCLUSION: The use of an ADS may improve the timing of medication administration in patients presenting to the ED without affecting dosing appropriateness.

6.
J Diabetes Sci Technol ; 5(3): 668-75, 2011 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-21722581

RESUMO

BACKGROUND: Real-time continuous glucose monitoring (RT-CGM) improves hemoglobin A1c (A1C) and hypoglycemia in people with type 1 diabetes mellitus and those with type 2 diabetes mellitus (T2DM) on prandial insulin; however, it has not been tested in people with T2DM not taking prandial insulin. We evaluated the utility of RT-CGM in people with T2DM on a variety of treatment modalities except prandial insulin. METHODS: We conducted a prospective, 52-week, two-arm, randomized trial comparing RT-CGM (n = 50) versus self-monitoring of blood glucose (SMBG) (n = 50) in people with T2DM not taking prandial insulin. Real-time continuous glucose monitoring was used for four 2-week cycles (2 weeks on/1 week off). All patients were managed by their usual provider. This article reports on changes in A1C 0-12 weeks. RESULTS: Mean (± standard deviation) decline in A1C at 12 weeks was 1.0% (± 1.1%) in the RT-CGM group and 0.5% (± 0.8%) in the SMBG group (p = .006). There were no group differences in the net change in number or dosage of hypoglycemic medications. Those who used the RT-CGM for ≥ 48 days (per protocol) reduced their A1C by 1.2% (± 1.1%) versus 0.6% (± 1.1%) in those who used it <48 days (p = .003). Multiple regression analyses statistically adjusting for baseline A1C, an indicator for usage, and known confounders confirmed the observed differences between treatment groups were robust (p = .009). There was no improvement in weight or blood pressure. CONCLUSIONS: Real-time continuous glucose monitoring significantly improves A1C compared with SMBG in patients with T2DM not taking prandial insulin. This technology might benefit a wider population of people with diabetes than previously thought.


Assuntos
Automonitorização da Glicemia/métodos , Diabetes Mellitus Tipo 1/sangue , Diabetes Mellitus Tipo 1/terapia , Diabetes Mellitus Tipo 2/sangue , Diabetes Mellitus Tipo 2/terapia , Adulto , Idoso , Glicemia/química , Feminino , Hemoglobinas Glicadas/análise , Humanos , Hipoglicemia/tratamento farmacológico , Insulina/metabolismo , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Análise de Regressão , Resultado do Tratamento
7.
Transfusion ; 45(3): 433-9, 2005 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-15752163

RESUMO

INTRODUCTION: Monocytes or mononuclear cells have been investigated for the treatment of chronic wounds and spinal cord injuries, as well as serve as a source for dendritic or endothelial cell culture. Because these cells may have clinical benefit yet no rapid and inexpensive closed system for monocyte purification is commercially available, a method was investigated to enrich monocytes from mononuclear apheresis units using a cord blood filter. METHODS: A 4-step method for monocyte enrichment was developed which involved 1) filtering a mononuclear apheresis unit through a cord blood filter, 2) chasing with medium to remove non-adherent residual cells and plasma, 3) back-flushing under low shear conditions to remove loosely adherent lymphocytes, and 4) back-flushing under high shear conditions to collect a fraction enriched in monocytes. Apheresis units and enriched monocyte preparations were characterized by cell count and differential, filter-isolated preparations were cryopreserved, and thawed preparations were assayed for viability, and phagocytosis. Enriched monocyte preparations were also assayed for inflammatory cytokines secretion and secretion of prostaglandin E2 during short-term culture. RESULTS: Monocytes were viable, capable of phagocytosis, and enriched using the multistep filter elution technique to represent 42 +/- 13-percent of white cells in the final preparation. Fifty-three-percent of monocytes were recovered in the final preparation, while total cell counts of red cells, platelets, neutrophils and lymphocytes were reduced to 3.0, 3.0, 4.5 and 16-percent, respectively, from levels present in mononuclear apheresis units. Filter enriched monocyte preparations secreted IL-8, IL-6, MCP-1, and MIP-1alpha, during short term culture. CONCLUSION: The use of a multi-step back flush procedure with a cord blood filter resulted in rapid enrichment of viable and functional monocytes from mononuclear apheresis units with significant reduction of contaminating platelets and red cells.


Assuntos
Remoção de Componentes Sanguíneos/métodos , Separação Celular/métodos , Sangue Fetal/citologia , Monócitos/citologia , Células Cultivadas , Quimiocinas/metabolismo , Citocinas/metabolismo , Dinoprostona/metabolismo , Ensaio de Imunoadsorção Enzimática , Humanos , Linfócitos , Monócitos/metabolismo , Fagocitose/imunologia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...