Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 301
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Electrophoresis ; 45(13-14): 1182-1197, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38837242

RESUMO

Electric field-driven microfluidics, known as electrofluidics, is a novel attractive analytical tool when it is integrated with low-cost textile substrate. Textile-based electrofluidics, primarily explored on yarn substrates, is in its early stages, with few studies on 3D structures. Further, textile structures have rarely been used in cellular analysis as a low-cost alternative. Herein, we investigated novel 3D textile structures and develop optimal electrophoretic designs and conditions that are favourable for direct 3D cell culture integration, developing an integrated cell culture textile-based electrofluidic platform that was optimised to balance electrokinetic performance and cell viability requirements. Significantly, there were contrasting electrolyte compositional conditions that were required to satisfy cell viability and electrophoretic mobility requiring the development of and electrolyte that satisfied the minimum requirements of both these components within the one platform. Human dermal fibroblast cell cultures were successfully integrated with gelatine methacryloyl (GelMA) hydrogel-coated electrofluidic platform and studied under different electric fields using 5 mM TRIS/HEPES/300 mM glucose. Higher analyte mobility was observed on 2.5% GelMA-coated textile which also facilitated excellent cell attachment, viability and proliferation. Cell viability also increased by decreasing the magnitude and time duration of applied electric field with good cell viability at field of up to 20 V cm-1.


Assuntos
Técnicas de Cultura de Células , Sobrevivência Celular , Fibroblastos , Técnicas Analíticas Microfluídicas , Têxteis , Humanos , Técnicas Analíticas Microfluídicas/instrumentação , Técnicas Analíticas Microfluídicas/métodos , Fibroblastos/citologia , Técnicas de Cultura de Células/métodos , Desenho de Equipamento , Células Cultivadas
2.
Electrophoresis ; 45(13-14): 1171-1181, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38837441

RESUMO

The integration of microfluidics with electric field control, commonly referred to as electrofluidics, has led to new opportunities for biomedical analysis. The requirement for closed microcapillary channels in microfluidics, typically formed via complex microlithographic fabrication approaches, limits the direct accessibility to the separation processes during conventional electrofluidic devices. Textile structures provide an alternative and low-cost approach to overcome these limitations via providing open and surface-accessible capillary channels. Herein, we investigate the potential of different 3D textile structures for electrofluidics. In this study, 12 polyester yarns were braided around nylon monofilament cores of different diameters to produce functional 3D core-shell textile structures. Capillary electrophoresis performances of these 3D core-shell textile structures both before and after removing the nylon core were evaluated in terms of mobility and bandwidth of a fluorescence marker compound. It was shown that the fibre arrangement and density govern the inherent capillary formation within these textile structures which also impacts upon the solute analyte mobility and separation bandwidth during electrophoretic studies. Core-shell textile structures with a 0.47 mm nylon core exhibited the highest fluorescein mobility and presented a narrower separation bandwidth. This optimal textile structure was readily converted to different geometries via a simple heat-setting of the central nylon core. This approach can be used to fabricate an array of miniaturized devices that possess many of the basic functionalities required in electrofluidics while maintaining open surface access that is otherwise impractical in classical approaches.


Assuntos
Eletroforese Capilar , Têxteis , Têxteis/análise , Eletroforese Capilar/métodos , Eletroforese Capilar/instrumentação , Desenho de Equipamento , Técnicas Analíticas Microfluídicas/instrumentação , Nylons/química
3.
Phys Med Biol ; 69(14)2024 Jul 04.
Artigo em Inglês | MEDLINE | ID: mdl-38914107

RESUMO

Objective.This study aims to design, manufacture, and test 3D printed quality assurance (QA) dosimetry phantoms for synchrotron brain cancer radiation therapy at the Australian synchrotron.Approach.Fabricated 3D printed phantoms from simple slab phantoms, a preclinical rat phantom, and an anthropomorphic head phantom were fabricated and characterized. Attenuation measurements of various polymers, ceramics and metals were acquired using synchrotron monochromatic micro-computed tomography (CT) imaging. Polylactic acid plus, VeroClear, Durable resin, and tricalcium phosphate were used in constructing the phantoms. Furthermore, 3D printed bone equivalent materials were compared relative to ICRU bone and hemihydrate plaster. Homogeneous and heterogeneous rat phantoms were designed and fabricated using tissue-equivalent materials. Geometric accuracy, CT imaging, and consistency were considered. Moreover, synchrotron broad-beam x-rays were delivered using a 3 Tesla superconducting multipole wiggler field for four sets of synchrotron radiation beam qualities. Dose measurements were acquired using a PinPoint ionization chamber and compared relative to a water phantom and a RMI457 Solid Water phantom. Experimental depth doses were compared relative to calculated doses using a Geant4 Monte Carlo simulation.Main results.Polylactic acid (PLA+) shows to have a good match with the attenuation coefficient of ICRU water, while both tricalcium phosphate and hydroxyapatite have good attenuation similarity with ICRU bone cortical. PLA+ material can be used as substitute to RMI457 slabs for reference dosimetry with a maximum difference of 1.84%. Percent depth dose measurement also shows that PLA+ has the best match with water and RMI457 within ±2.2% and ±1.6%, respectively. Overall, PLA+ phantoms match with RMI457 phantoms within ±3%.Significance and conclusion.The fabricated phantoms are excellent tissue equivalent equipment for synchrotron radiation dosimetry QA measurement. Both the rat and the anthropomorphic head phantoms are useful in synchrotron brain cancer radiotherapy dosimetry, experiments, and future clinical translation of synchrotron radiotherapy and imaging.


Assuntos
Neoplasias Encefálicas , Imagens de Fantasmas , Impressão Tridimensional , Radiometria , Síncrotrons , Ratos , Animais , Radiometria/instrumentação , Neoplasias Encefálicas/radioterapia , Neoplasias Encefálicas/diagnóstico por imagem , Dosagem Radioterapêutica , Método de Monte Carlo , Garantia da Qualidade dos Cuidados de Saúde , Desenho de Equipamento
4.
3D Print Addit Manuf ; 11(2): 447-459, 2024 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-38689898

RESUMO

In the field of tissue engineering and regenerative medicine, developing cytocompatible 3D conductive scaffolds that mimic the native extracellular matrix is crucial for the engineering of excitable cells and tissues. In this study, a custom cryogenic extrusion 3D printer was developed, which afforded control over both the ink and printing surface temperatures. Using this approach, aqueous inks were printed into well-defined layers with high precision. A conductive hydrogel ink was developed from chitosan (CS) and edge-functionalised expanded graphene (EFXG). Different EFXG:CS ratios (between 60:40 and 80:20) were evaluated to determine both conductivity and printability. Using the novel customized cryogenic 3D printer, conductive structures of between 2 and 20 layers were produced, with feature sizes as small as 200 µm. The printed structures are mechanically robust and are electrically conducting. The highest Young's modulus and conductivity in a hydrated state were 2.6 MPa and ∼45 S/m, respectively. Cytocompatibility experiments reveal that the developed material supports NSC-34 mouse motor neuron-like cells in terms of viability, attachment, and proliferation. The distinctive mechanical and electrical properties of the 3D-printed structures would make them good candidates for the engineering of 3D-structured excitable cells. Moreover, this novel printing setup can be used to print other hydrogel-based inks with high precision and resolution.

5.
ChemSusChem ; : e202400209, 2024 Apr 30.
Artigo em Inglês | MEDLINE | ID: mdl-38688856

RESUMO

Polyaniline (PANI) provides an attractive organic platform for CO2 electrochemical reduction due to the ability to adsorb CO2 molecules and in providing means to interact with metal nanostructures. In this work, a novel PANI supported copper catalyst has been developed by coupling the interfacial polymerization of PANI and Cu. The hybrid catalyst demonstrates excellent activity towards production of hydrocarbon products including CH4 and C2H4, compared with the use of bare Cu. A Faradaic efficiency of 71.8 % and a current density of 16.9 mA/cm2 were achieved at -0.86 V vs. RHE, in contrast to only 22.2 % and 1.0 mA/cm2 from the counterpart Cu catalysts. The remarkably enhanced catalytic performance of the hybrid PANI/Cu catalyst can be attributed to the synergistic interaction between the PANI underlayer and copper. The PANI favours the adsorption and binding of CO2 molecules via its nitrogen sites to form *CO intermediates, while the Cu/PANI interfaces confine the diffusion or desorption of the *CO intermediates favouring their further hydrogenation or carbon-carbon coupling to form hydrocarbon products. This work provides insights into the formation of hydrocarbon products on PANI-modified Cu catalysts, which may guide the development of conducting polymer-metal catalysts for CO2 electroreduction.

6.
Angew Chem Int Ed Engl ; 62(49): e202315182, 2023 Dec 04.
Artigo em Inglês | MEDLINE | ID: mdl-37872352

RESUMO

The exploration of inexpensive and efficient catalysts for oxygen reduction reaction (ORR) is crucial for chemical and energy industries. Carbon materials have been proved promising with different catalysts enabling 2 and 4e- ORR. Nevertheless, their ORR activity and selectivity is still complex and under debate in many cases. Many structures of these active carbon materials are also chemically unstable for practical implementations. Unlike the well-discussed structures, this work presents a strategy to promote efficient and stable 2e- ORR of carbon materials through the synergistic effect of lattice distortion and H-passivation (on the distorted structure). We show how these structures can be formed on carbon cloth, and how the reproducible chemical adsorption can be realized on these structures for efficient and stable H2 O2 production. The work here gives not only new understandings on the 2e- ORR catalysis, but also the robust catalyst which can be directly used in industry.

7.
ACS Appl Mater Interfaces ; 15(32): 38833-38845, 2023 Aug 16.
Artigo em Inglês | MEDLINE | ID: mdl-37537952

RESUMO

The design of neural electrodes has changed in the past decade, driven mainly by the development of new materials that open the possibility of manufacturing electrodes with adaptable mechanical properties and promising electrical properties. In this paper, we report on the mechanical and electrochemical properties of a polydimethylsiloxane (PDMS) composite with edge-functionalized graphene (EFG) and demonstrate its potential for use in neural implants with the fabrication of a novel neural cuff electrode. We have shown that a 200 µm thick 1:1 EFG/PDMS composite film has a stretchability of up to 20%, a Young's modulus of 2.52 MPa, and a lifetime of more than 10000 mechanical cycles, making it highly suitable for interfacing with soft tissue. Electrochemical characterization of the EFG/PDMS composite film showed that the capacitance of the composite increased up to 35 times after electrochemical reduction, widening the electrochemical water window and remaining stable after soaking for 5 weeks in phosphate buffered saline. The electrochemically activated EFG/PDMS electrode had a 3 times increase in the charge injection capacity, which is more than double that of a commercial platinum-based neural cuff. Electrochemical and spectrochemical investigations supported the conclusion that this effect originated from the stable chemisorption of hydrogen on the graphene surface. The biocompatibility of the composite was confirmed with an in vitro cell culture study using mouse spinal cord cells. Finally, the potential of the EFG/PDMS composite was demonstrated with the fabrication of a novel neural cuff electrode, whose double-layered and open structured design increased the cuff stretchability up to 140%, well beyond that required for an operational neural cuff. In addition, the cuff design offers better integration with neural tissue and simpler nerve fiber installation and locking.


Assuntos
Grafite , Tecido Nervoso , Camundongos , Animais , Eletrodos , Dimetilpolisiloxanos/química
8.
Macromol Biosci ; 23(12): e2300220, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-37589999

RESUMO

The development of biomimetic structures with integrated extracellular matrix (ECM) components represents a promising approach to biomaterial fabrication. Here, an artificial ECM, comprising the structural protein collagen I and elastin (ELN), as well as the glycosaminoglycan hyaluronan (HA), is reported. Specifically, collagen and ELN are electrochemically aligned to mimic the compositional characteristics of the dermal matrix. HA is incorporated into the electro-compacted collagen-ELN matrices via adsorption and chemical immobilization, to give a final composition of collagen/ELN/HA of 7:2:1. This produces a final collagen/ELN/hyaluronic acid scaffold (CEH) that recapitulates the compositional feature of the native skin ECM. This study analyzes the effect of CEH composition on the cultivation of human dermal fibroblast cells (HDFs) and immortalized human keratinocytes (HaCaTs). It is shown that the CEH scaffold supports dermal regeneration by promoting HDFs proliferation, ECM deposition, and differentiation into myofibroblasts. The CEH scaffolds are also shown to support epidermis growth by supporting HaCaTs proliferation, differentiation, and stratification. A double-layered epidermal-dermal structure is constructed on the CEH scaffold, further demonstrating its ability in supporting skin cell function and skin regeneration.


Assuntos
Ácido Hialurônico , Pele , Humanos , Ácido Hialurônico/farmacologia , Ácido Hialurônico/química , Pele/metabolismo , Matriz Extracelular/química , Colágeno/química , Elastina/farmacologia , Fibroblastos
9.
Regen Med ; 18(8): 659-674, 2023 08.
Artigo em Inglês | MEDLINE | ID: mdl-37403962

RESUMO

New developments in additive manufacturing and regenerative medicine have the potential to radically disrupt the traditional pipelines of therapy development and medical device manufacture. These technologies present a challenge for regulators because traditional regulatory frameworks are designed for mass manufactured therapies, rather than bespoke solutions. 3D bioprinting technologies present another dimension of complexity through the inclusion of living cells in the fabrication process. Herein we overview the challenge of regulating 3D bioprinting in comparison to existing cell therapy products as well as custom-made 3D printed medical devices. We consider a range of specific challenges pertaining to 3D bioprinting in regenerative medicine, including classification, risk, standardization and quality control, as well as technical issues related to the manufacturing process and the incorporated materials and cells.


Assuntos
Bioimpressão , Engenharia Tecidual , Engenharia Tecidual/métodos , Bioimpressão/métodos , Impressão Tridimensional , Medicina Regenerativa/métodos , Terapia Baseada em Transplante de Células e Tecidos , Alicerces Teciduais
10.
Mol Pharm ; 20(7): 3403-3411, 2023 07 03.
Artigo em Inglês | MEDLINE | ID: mdl-37226701

RESUMO

Effective control of post-operative inflammation after tissue repair remains a clinical challenge. A tissue repair patch that could appropriately integrate into the surrounding tissue and control inflammatory responses would improve tissue healing. A collagen-based hybrid tissue repair patch has been developed in this work for the local delivery of an anti-inflammatory drug. Dexamethasone (DEX) was encapsulated into PLGA microspheres and then co-electrocompacted into a collagen membrane. Using a simple process, multiple drugs can be loaded into and released from this hybrid composite material simultaneously, and the ratio between each drug is controllable. Anti-inflammatory DEX and the anti-epileptic phenytoin (PHT) were co-encapsulated and released to validate the dual drug delivery ability of this versatile composite material. Furthermore, the Young's modulus of this drug-loaded collagen patch was increased to 20 KPa using a biocompatible riboflavin (vitamin B2)-induced UV light cross-linking strategy. This versatile composite material has a wide range of potential applications which deserve exploration in further research.


Assuntos
Anti-Inflamatórios , Dexametasona , Humanos , Preparações Farmacêuticas , Colágeno , Inflamação , Riboflavina , Microesferas
11.
Adv Sci (Weinh) ; 10(12): e2207603, 2023 04.
Artigo em Inglês | MEDLINE | ID: mdl-36782094

RESUMO

The deployment of structures that enable localized release of bioactive molecules can result in more efficacious treatment of disease and better integration of implantable bionic devices. The strategic design of a biopolymeric coating can be used to engineer the optimal release profile depending on the task at hand. As illustrative examples, here advances in delivery of drugs from bone, brain, ocular, and cardiovascular implants are reviewed. These areas are focused to highlight that both hard and soft tissue implants can benefit from controlled localized delivery. The composition of biopolymers used to achieve appropriate delivery to the selected tissue types, and their corresponding outcomes are brought to the fore. To conclude, key factors in designing drug-loaded biopolymeric coatings for biomedical implants are highlighted.


Assuntos
Próteses e Implantes , Biopolímeros
12.
J Biomed Mater Res B Appl Biomater ; 111(3): 526-537, 2023 03.
Artigo em Inglês | MEDLINE | ID: mdl-36269163

RESUMO

Hydrogel materials are promising candidates in cartilage tissue engineering as they provide a 3D porous environment for cell proliferation and the development of new cartilage tissue. Both the mechanical and transport properties of hydrogel scaffolds influence the ability of encapsulated cells to produce neocartilage. In photocrosslinkable hydrogels, both of these material properties can be tuned by changing the crosslinking density. However, the interdependent nature of the structural, physical and biological properties of photocrosslinkable hydrogels means that optimizing composition is typically a complicated process, involving sequential and/or iterative steps of physiochemical and biological characterization. The combinational nature of the variables indicates that an exhaustive analysis of all reasonable concentration ranges would be impractical. Herein, response surface methodology (RSM) was used to efficiently optimize the composition of a hybrid of gelatin-methacryloyl (GelMA) and hyaluronic acid methacryloyl (HAMA) with respect to both mechanical and transport properties. RSM was employed to investigate the effect of GelMA, HAMA, and photoinitiator concentration on the shear modulus and diffusion coefficient of the hydrogel membrane. Two mathematical models were fitted to the experimental data and used to predict the optimum hydrogel composition. Finally, the optimal composition was tested and compared with the predicted values.


Assuntos
Gelatina , Hidrogéis , Hidrogéis/química , Gelatina/química , Ácido Hialurônico , Metacrilatos/química , Engenharia Tecidual/métodos , Alicerces Teciduais/química
13.
Front Bioeng Biotechnol ; 10: 994776, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-36394046

RESUMO

Tissue engineered constructs can serve as in vitro models for research and replacement of diseased or damaged tissue. As an emerging technology, 3D bioprinting enables tissue engineering through the ability to arrange biomaterials and cells in pre-ordered structures. Hydrogels, such as alginate (Alg), can be formulated as inks for 3D bioprinting. However, Alg has limited cell affinity and lacks the functional groups needed to promote cell growth. In contrast, graphene oxide (GO) can support numerous cell types and has been purported for use in regeneration of bone, neural and cardiac tissues. Here, GO was incorporated with 2% (w/w) Alg and 3% (w/w) gelatin (Gel) to improve 3D printability for extrusion-based 3D bioprinting at room temperature (RT; 25°C) and provide a 3D cellular support platform. GO was more uniformly distributed in the ink with our developed method over a wide concentration range (0.05%-0.5%, w/w) compared to previously reported GO containing bioink. Cell support was confirmed using adipose tissue derived stem cells (ADSCs) either seeded onto 3D printed GO scaffolds or encapsulated within the GO containing ink before direct 3D printing. Added GO was shown to improve cell-affinity of bioinert biomaterials by providing more bioactive moieties on the scaffold surface. 3D cell-laden or cell-seeded constructs showed improved cell viability compared to pristine (without GO) bio-ink-based scaffolds. Our findings support the application of GO for novel bio-ink formulation, with the potential to incorporate other natural and synthetic materials such as chitosan and cellulose for advanced in situ biosensing, drug-loading and release, and with the potential for electrical stimulation of cells to further augment cell function.

14.
ACS Appl Bio Mater ; 5(11): 5041-5056, 2022 11 21.
Artigo em Inglês | MEDLINE | ID: mdl-36260917

RESUMO

Electrochemistry has become a powerful strategy to modulate cellular behavior and biological activity by manipulating electrical signals. Subsequent electrical stimulus-responsive conducting polymers (CPs) have advanced traditional wired electrochemical stimulation (ES) systems and developed wireless cell stimulation systems due to their electroconductivity, biocompatibility, stability, and flexibility. Bipolar electrochemistry (BPE), i.e., wireless electrochemistry, offers an effective pathway to modify wired ES systems into a desirable contactless mode, turning out a potential technique to offer fundamental insights into neural cell stimulation and neural network formation. This review commences with a brief discussion of the BPE technique and also the advantages of a bipolar electrochemical stimulation (BPES) system compared to traditional wired ES systems and other wireless ES systems. Then, the BPES system is elucidated through four aspects: the benefits of BPES, the key factors to establish BPES platforms for cell stimulation, the limits/barriers to overcome for current rigid materials in particular metals-based systems, and a brief overview of the concept proved by CPs-based systems. Furthermore, how to refine the existing BPES system from materials/devices modification that combine CP compositions with 3D fabrication/bioprinting technologies is elaborately discussed as well. Finally, the review ends together with future research directions, picturing the potential of BPES system in biomedical applications.


Assuntos
Polímeros , Polímeros/química , Eletroquímica
15.
Polymers (Basel) ; 14(20)2022 Oct 12.
Artigo em Inglês | MEDLINE | ID: mdl-36297848

RESUMO

As the most prevalent structural protein in the extracellular matrix, collagen has been extensively investigated for biofabrication-based applications. However, its utilisation has been impeded due to a lack of sufficient mechanical toughness and the inability of the scaffold to mimic complex natural tissues. The anisotropic alignment of collagen fibres has been proven to be an effective method to enhance its overall mechanical properties and produce biomimetic scaffolds. This review introduces the complicated scenario of collagen structure, fibril arrangement, type, function, and in addition, distribution within the body for the enhancement of collagen-based scaffolds. We describe and compare existing approaches for the alignment of collagen with a sharper focus on electro-compaction. Additionally, various effective processes to further enhance electro-compacted collagen, such as crosslinking, the addition of filler materials, and post-alignment fabrication techniques, are discussed. Finally, current challenges and future directions for the electro-compaction of collagen are presented, providing guidance for the further development of collagenous scaffolds for bioengineering and nanotechnology.

16.
ACS Appl Mater Interfaces ; 14(40): 45149-45155, 2022 Oct 12.
Artigo em Inglês | MEDLINE | ID: mdl-36169191

RESUMO

A surface electromyogram (sEMG) electrode collects electrical currents generated by neuromuscular activity by a noninvasive technique on the skin. It is particularly attractive for wearable systems for various human activities and health care monitoring. However, it remains challenging to discriminate EMG signals from isotonic (concentric/eccentric) and isometric movements. By applying nanotechnology, we provide a coiled carbon nanotube (CNT) yarn-integrated sEMG device to overcome sEMG-based motion recognition. When the arm was contracted at different angles, the sEMG-derived root mean square amplitude signals were constant regardless of the angle of the moving arm. However, the coiled CNT yarn-derived open circuit voltage (OCV) signals proportionally increased when the arm's angle increased, and presented negative and positive values depending on the moving direction of the arm. Moreover, isometric contraction is characterized by the onset of EMG signals without an OCV signal, and isotonic contraction is determined by both EMG signals and OCV signals. Taken together, the integration of EMG and coiled CNT yarn electrodes provides complementary information, including the strength, direction, and degree of muscle movement. Therefore, we suggest that our system has high potential as a wearable system to monitor human motions in industrial and human system applications.


Assuntos
Nanotubos de Carbono , Eletromiografia , Humanos , Contração Isométrica/fisiologia , Movimento , Músculo Esquelético/fisiologia
17.
Data Brief ; 43: 108393, 2022 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-35781980

RESUMO

Data in this article is associated with our research article "Enhanced wireless cell stimulation using soft and improved bipolar electroactive conducting polymer templates" Qin et al. (2022). Primarily, the present article shows the data of PPy-PMAS/FTO, PPy-PMAS-collagen/FTO and PPy-PMAS-DS-collagen/FTO in conventional electrochemical process and bipolar electrochemical process along with in situ spectrometry for comprehensive supplement and comparison to help with better developing modified conducting polymers based bipolar electrochemistry. Secondly, the presented the complete dataset useful for modelling the soft and improved bipolar electroactive conducting polymers focusing on wireless cell (animal and human) stimulation, which are reported in the main article. All data reported were analysed using Origin 2019b 64Bit.

18.
Acta Biomater ; 147: 129-146, 2022 07 15.
Artigo em Inglês | MEDLINE | ID: mdl-35643197

RESUMO

In this work we present a standardised quantitative ultrasound imaging (SQUI) approach for the non-destructive three-dimensional imaging and quantification of cartilage formation in hydrogel based bioscaffolds. The standardised concept involves the processing of ultrasound backscatter data with respect to an acellular phantom in combination with the compensation of sound speed mismatch diffraction effects between the bioscaffold and the phantom. As a proof-of-concept, the SQUI approach was tested on a variety of bioscaffolds with varying degree of neocartilage formation. These were composed of Gelatine Methacryloyl (GelMA) hydrogels laden with human adipose-derived stem cells (hADSCs). These were cultured under chondrogenic stimulation following a previously established protocol, where the degree of the neocartilage formation was modulated using different GelMA network densities (6, 8, 10 % w/v) and culture time (0, 14, 28 days). Using the SQUI approach we were able to detect marked acoustic and morphological changes occurring in the bioscaffolds a result of their different chondrogenic outcome. We defined an acoustic neocartilage indicator, the sonomarker, for the selective imaging and quantification of neocartilage formation. The sonomarker, of backscatter intensity logIBC -2.4, was found to correlate with data obtained via standard destructive bioassays. The ultrasonic evaluation of human specimens confirmed the sonomarker as a relevant intensity, although it was found to shift to higher intensity values in proportion to the cartilage condition as inferred from sound speed measurements. This study demonstrates the potential of the SQUI approach for the realization of non-destructive analysis of cartilage regeneration over-time. STATEMENT OF SIGNIFICANCE: As tissue engineering strategies for neocartilage regeneration evolve towards clinical implementation, alternative characterisation approaches that allow the non-destructive monitoring of extracellular matrix formation in implantable hydrogel based bioscaffolds are needed. In this work we present an innovative standardized quantitative ultrasound imaging (SQUI) approach that allows the non-destructive, volumetric, and quantitative evaluation of neocartilage formation in hydrogel based bioscaffolds. The standardised concept aims to provide a robust approach that accounts for the dynamic changes occurring during the conversion from a cellular bioscaffold towards the formation of a neocartilage construct. We believe that the SQUI approach will be of great benefit for the evaluation of constructs developing neocartilage, not only for in-vitro applications but also potentially applicable to in-vivo applications.


Assuntos
Condrogênese , Hidrogéis , Cartilagem/diagnóstico por imagem , Cartilagem/fisiologia , Humanos , Hidrogéis/farmacologia , Engenharia Tecidual/métodos , Ultrassonografia
19.
Small Methods ; 6(7): e2200344, 2022 07.
Artigo em Inglês | MEDLINE | ID: mdl-35689331

RESUMO

Iron is a promising material for cardiovascular stent applications, however, the low biodegradation rate presents a challenge. Here, a dynamic method to improve the degradation rate of iron and simultaneously deliver electrical energy that could potentially inhibit cell proliferation on the device is reported. It is realized by pairing iron with a biocompatible hydrogel cathode in a cell culture media-based electrolyte forming an iron-air battery. This system does not show cytotoxicity to human adipose-stem cells over a period of 21 days but inhibits cell proliferation. The combination of enhanced iron degradation and inhibited cell proliferation by this dynamic method suggests it might be an approach for restenosis inhibition of biodegradable stents.


Assuntos
Ferro , Stents , Humanos , Ferro/farmacologia
20.
Polymers (Basel) ; 14(12)2022 Jun 09.
Artigo em Inglês | MEDLINE | ID: mdl-35745911

RESUMO

The adoption of additive manufacturing (AM) techniques into the medical space has revolutionised tissue engineering. Depending upon the tissue type, specific AM approaches are capable of closely matching the physical and biological tissue attributes, to guide tissue regeneration. For hard tissue such as bone, powder bed fusion (PBF) techniques have significant potential, as they are capable of fabricating materials that can match the mechanical requirements necessary to maintain bone functionality and support regeneration. This review focuses on the PBF techniques that utilize laser sintering for creating scaffolds for bone tissue engineering (BTE) applications. Optimal scaffold requirements are explained, ranging from material biocompatibility and bioactivity, to generating specific architectures to recapitulate the porosity, interconnectivity, and mechanical properties of native human bone. The main objective of the review is to outline the most common materials processed using PBF in the context of BTE; initially outlining the most common polymers, including polyamide, polycaprolactone, polyethylene, and polyetheretherketone. Subsequent sections investigate the use of metals and ceramics in similar systems for BTE applications. The last section explores how composite materials can be used. Within each material section, the benefits and shortcomings are outlined, including their mechanical and biological performance, as well as associated printing parameters. The framework provided can be applied to the development of new, novel materials or laser-based approaches to ultimately generate bone tissue analogues or for guiding bone regeneration.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...