Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 13 de 13
Filtrar
1.
BMJ Open ; 11(5): e046685, 2021 05 10.
Artigo em Inglês | MEDLINE | ID: mdl-33972342

RESUMO

OBJECTIVES: To assess an intervention for surgical antibiotic prophylaxis (SAP) improvement within surgical teams focused on addressing barriers and fostering enablers and ownership of guideline compliance. DESIGN: The Queensland Surgical Antibiotic Prophylaxis (QSAP) study was a multicentre, mixed methods study designed to address barriers and enablers to SAP compliance and facilitate engagement in self-directed audit/feedback and assess the efficacy of the intervention in improving compliance with SAP guidelines. The implementation was assessed using a 24-month interrupted time series design coupled with a qualitative evaluation. SETTING: The study was undertaken at three hospitals (one regional, two metropolitan) in Australia. PARTICIPANTS: SAP-prescribing decisions for 1757 patients undergoing general surgical procedures from three health services were included. Six bimonthly time points, pre-implementation and post implementation of the intervention, were measured. Qualitative interviews were performed with 29 clinical team members. SAP improvements varied across site and time periods. INTERVENTION: QSAP embedded ownership of quality improvement in SAP within surgical teams and used known social influences to address barriers to and enablers of optimal SAP prescribing. RESULTS: The site that reported senior surgeon engagement showed steady and consistent improvement in prescribing over 24 months (prestudy and poststudy). Multiple factors, including resource issues, influenced engagement and sites/time points where these were present had no improvement in guideline compliance. CONCLUSIONS: The barriers-enablers-ownership model shows promise in its ability to facilitate prescribing improvements and could be expanded into other areas of antimicrobial stewardship. Senior ownership was a predictor of success (or failure) of the intervention across sites and time periods. The key role of senior leaders in change leadership indicates the critical need to engage other specialties in the stewardship agenda. The influence of contextual factors in limiting engagement clearly identifies issues of resource distributions/inequalities within health systems as limiting antimicrobial optimisation potential.


Assuntos
Antibacterianos , Propriedade , Antibacterianos/uso terapêutico , Austrália , Fidelidade a Diretrizes , Hospitais , Humanos , Queensland
2.
Emerg Med J ; 37(11): 717-721, 2020 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-32075849

RESUMO

Refractory hypotension is one of the most common and difficult clinical problems faced by acute care clinicians, and it poses a particularly large problem to the emergency physician when a patient in undifferentiated shock arrives in the department. Angiotensin II (Ang-2) has been previously used as a vasopressor to combat shock; the feasibility of its clinical use has been reinvigorated after approval of a human synthetic formulation of the medication by the US Food and Drug Administration in 2017 and the European Medicines Agency in 2019. A thorough literature search was completed, and in this review, we discuss the discovery and development of Ang-2, its complex mechanisms of vasoconstriction, its potential adverse effects and its potential role in clinical practice for emergency physicians.


Assuntos
Angiotensina II/uso terapêutico , Cuidados Críticos , Serviço Hospitalar de Emergência , Hipotensão/tratamento farmacológico , Choque/tratamento farmacológico , Vasoconstritores/uso terapêutico , Humanos
3.
BMJ Open ; 9(12): e033053, 2019 12 02.
Artigo em Inglês | MEDLINE | ID: mdl-31796493

RESUMO

OBJECTIVES: The aim of this study was to develop and validate a scale to measure the coping strategies used by emergency staff in response to workplace stress. To achieve this aim, we developed a refined Jalowiec Coping Scale (JCS), termed the Jalowiec Coping Scale-Emergency Department (JCS-ED) and validated this scale on a sample of emergency clinicians. DESIGN: A cross-sectional survey incorporating the JCS, the working environment scale-10 and a measure of workplace stressors was administered between July 2016 and June 2017. The JCS-ED was developed in three stages: 1) item reduction through content matter experts, 2) exploratory factor analysis for further item reduction and to identify the factor structure of the revised scale and 3) confirmatory factor analyses to confirm the factors identified within the exploratory factor analysis. SETTING: Six Emergency Departments (EDs) in Australia and four in Sweden. There were three tertiary hospitals, five large urban hospitals and two small urban hospitals. PARTICIPANTS: Participants were eligible for inclusion if they worked full-time or part-time as medical or nursing staff in the study EDs. The median age of participants was 35 years (IQR: 28-45 years) and they had been working in the ED for a median of 5 years (IQR: 2-10 years). 79% were females and 76% were nurses. RESULTS: A total of 875 ED staff completed the survey (response rate 51%). The content matter experts reduced the 60-item scale to 32 items. Exploratory factor analyses then further reduced the scale to 18 items assessing three categories of coping: problem-focussed coping, positive emotion-focussed coping and negative emotion-focussed coping. Confirmatory factor analysis supported this three-factor structure. Negative coping strategies were associated with poor perceptions of the work environment and higher ratings of stress. CONCLUSIONS: The JCS-ED assesses maladaptive coping strategies along with problem-focussed and emotion-focussed coping styles. It is a short instrument that is likely to be useful in measuring the types of coping strategies employed by staff.


Assuntos
Adaptação Psicológica , Serviço Hospitalar de Emergência/estatística & dados numéricos , Estresse Ocupacional/psicologia , Adulto , Austrália , Estudos Transversais , Análise Fatorial , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Psicometria/instrumentação , Inquéritos e Questionários , Suécia
5.
BMJ Open ; 8(5): e019916, 2018 05 14.
Artigo em Inglês | MEDLINE | ID: mdl-29764876

RESUMO

INTRODUCTION: Peripheral intravenous catheters (PIVCs) are frequently used in hospitals. However, PIVC complications are common, with failures leading to treatment delays, additional procedures, patient pain and discomfort, increased clinician workload and substantially increased healthcare costs. Recent evidence suggests integrated PIVC systems may be more effective than traditional non-integrated PIVC systems in reducing phlebitis, infiltration and costs and increasing functional dwell time. The study aim is to determine the efficacy, cost-utility and acceptability to patients and professionals of an integrated PIVC system compared with a non-integrated PIVC system. METHODS AND ANALYSIS: Two-arm, multicentre, randomised controlled superiority trial of integrated versus non-integrated PIVC systems to compare effectiveness on clinical and economic outcomes. Recruitment of 1560 patients over 2 years, with randomisation by a centralised service ensuring allocation concealment. Primary outcomes: catheter failure (composite endpoint) for reasons of: occlusion, infiltration/extravasation, phlebitis/thrombophlebitis, dislodgement, localised or catheter-associated bloodstream infections. SECONDARY OUTCOMES: first time insertion success, types of PIVC failure, device colonisation, insertion pain, functional dwell time, adverse events, mortality, cost-utility and consumer acceptability. One PIVC per patient will be included, with intention-to-treat analysis. Baseline group comparisons will be made for potentially clinically important confounders. The proportional hazards assumption will be checked, and Cox regression will test the effect of group, patient, device and clinical variables on failure. An as-treated analysis will assess the effect of protocol violations. Kaplan-Meier survival curves with log-rank tests will compare failure by group over time. Secondary endpoints will be compared between groups using parametric/non-parametric techniques. ETHICS AND DISSEMINATION: Ethical approval from the Royal Brisbane and Women's Hospital Human Research Ethics Committee (HREC/16/QRBW/527), Griffith University Human Research Ethics Committee (Ref No. 2017/002) and the South Metropolitan Health Services Human Research Ethics Committee (Ref No. 2016-239). Results will be published in peer-reviewed journals. TRIAL REGISTRATION NUMBER: ACTRN12617000089336.


Assuntos
Infecções Relacionadas a Cateter/prevenção & controle , Cateterismo Periférico/métodos , Austrália , Infecções Relacionadas a Cateter/etiologia , Cateterismo Periférico/efeitos adversos , Cateterismo Periférico/economia , Remoção de Dispositivo , Falha de Equipamento , Custos de Cuidados de Saúde , Humanos , Estimativa de Kaplan-Meier , Estudos Multicêntricos como Assunto , Modelos de Riscos Proporcionais , Ensaios Clínicos Controlados Aleatórios como Assunto
6.
J Eval Clin Pract ; 21(5): 893-9, 2015 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-26183837

RESUMO

RATIONALE, AIMS AND OBJECTIVES: Many peripheral intravenous catheter (PIVC) infusion phlebitis scales and definitions are used internationally, although no existing scale has demonstrated comprehensive reliability and validity. We examined inter-rater agreement between registered nurses on signs, symptoms and scales commonly used in phlebitis assessment. METHODS: Seven PIVC-associated phlebitis signs/symptoms (pain, tenderness, swelling, erythema, palpable venous cord, purulent discharge and warmth) were observed daily by two raters (a research nurse and registered nurse). These data were modelled into phlebitis scores using 10 different tools. Proportions of agreement (e.g. positive, negative), observed and expected agreements, Cohen's kappa, the maximum achievable kappa, prevalence- and bias-adjusted kappa were calculated. RESULTS: Two hundred ten patients were recruited across three hospitals, with 247 sets of paired observations undertaken. The second rater was blinded to the first's findings. The Catney and Rittenberg scales were the most sensitive (phlebitis in >20% of observations), whereas the Curran, Lanbeck and Rickard scales were the most restrictive (≤2% phlebitis). Only tenderness and the Catney (one of pain, tenderness, erythema or palpable cord) and Rittenberg scales (one of erythema, swelling, tenderness or pain) had acceptable (more than two-thirds, 66.7%) levels of inter-rater agreement. CONCLUSIONS: Inter-rater agreement for phlebitis assessment signs/symptoms and scales is low. This likely contributes to the high degree of variability in phlebitis rates in literature. We recommend further research into assessment of infrequent signs/symptoms and the Catney or Rittenberg scales. New approaches to evaluating vein irritation that are valid, reliable and based on their ability to predict complications need exploration.


Assuntos
Cateterismo Periférico/efeitos adversos , Enfermagem/métodos , Flebite/diagnóstico , Flebite/etiologia , Adulto , Idoso , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Variações Dependentes do Observador , Flebite/fisiopatologia , Prevalência , Reprodutibilidade dos Testes
7.
Nurs Res Pract ; 2015: 691934, 2015.
Artigo em Inglês | MEDLINE | ID: mdl-26075092

RESUMO

Objective. To document the incidence of postinfusion phlebitis and to investigate associated risk factors. Design. Analysis of existing data set from a large randomized controlled trial, the primary purpose of which was to compare routine peripheral intravascular catheter changes with changing catheters only on clinical indication. Participants and Setting. Patients admitted to a large, acute general hospital in Queensland, Australia, and who required a peripheral intravenous catheter. Results. 5,907 PIVCs from 3,283 patients were studied. Postinfusion phlebitis at 48 hours was diagnosed in 59 (1.8%) patients. Fifteen (25.4%) of these patients had phlebitis at removal and also at 48 hours after removal. When data were analyzed per catheter, the rate was lower, 62/5907 (1.1%). The only variable associated with postinfusion phlebitis was placement of the catheter in the emergency room (P = 0.03). Conclusion. Although not a common occurrence, postinfusion phlebitis may be problematic so it is important for health care staff to provide patients with information about what to look for after an intravascular device has been removed. This trial is registered with ACTRN12608000445370.

8.
BMJ Open ; 5(2): e007257, 2015 Feb 03.
Artigo em Inglês | MEDLINE | ID: mdl-25649214

RESUMO

INTRODUCTION: Vascular access devices (VADs), such as peripheral or central venous catheters, are vital across all medical and surgical specialties. To allow therapy or haemodynamic monitoring, VADs frequently require administration sets (AS) composed of infusion tubing, fluid containers, pressure-monitoring transducers and/or burettes. While VADs are replaced only when necessary, AS are routinely replaced every 3-4 days in the belief that this reduces infectious complications. Strong evidence supports AS use up to 4 days, but there is less evidence for AS use beyond 4 days. AS replacement twice weekly increases hospital costs and workload. METHODS AND ANALYSIS: This is a pragmatic, multicentre, randomised controlled trial (RCT) of equivalence design comparing AS replacement at 4 (control) versus 7 (experimental) days. Randomisation is stratified by site and device, centrally allocated and concealed until enrolment. 6554 adult/paediatric patients with a central venous catheter, peripherally inserted central catheter or peripheral arterial catheter will be enrolled over 4 years. The primary outcome is VAD-related bloodstream infection (BSI) and secondary outcomes are VAD colonisation, AS colonisation, all-cause BSI, all-cause mortality, number of AS per patient, VAD time in situ and costs. Relative incidence rates of VAD-BSI per 100 devices and hazard rates per 1000 device days (95% CIs) will summarise the impact of 7-day relative to 4-day AS use and test equivalence. Kaplan-Meier survival curves (with log rank Mantel-Cox test) will compare VAD-BSI over time. Appropriate parametric or non-parametric techniques will be used to compare secondary end points. p Values of <0.05 will be considered significant. ETHICS AND DISSEMINATION: Relevant ethical approvals have been received. CONSORT Statement recommendations will be used to guide preparation of any publication. Results will be presented at relevant conferences and sent to the major organisations with clinical practice guidelines for VAD care. TRIAL REGISTRATION NUMBER: Australian New Zealand Clinical Trial Registry (ACTRN 12610000505000).


Assuntos
Infecções Relacionadas a Cateter/prevenção & controle , Cateterismo Periférico , Cateteres de Demora , Cateteres Venosos Centrais , Remoção de Dispositivo/normas , Flebite/etiologia , Dispositivos de Acesso Vascular , Cateterismo Periférico/efeitos adversos , Cateteres de Demora/efeitos adversos , Cateteres Venosos Centrais/efeitos adversos , Protocolos Clínicos , Hospitalização , Humanos , Estimativa de Kaplan-Meier , Projetos de Pesquisa , Dispositivos de Acesso Vascular/efeitos adversos
9.
Aust Health Rev ; 38(3): 278-87, 2014 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-24869756

RESUMO

OBJECTIVES: The aims of the present study were to identify predictors of admission and describe outcomes for patients who arrived via ambulance to three Australian public emergency departments (EDs), before and after the opening of 41 additional ED beds within the area. METHODS: The present study was a retrospective comparative cohort study using deterministically linked health data collected between 3 September 2006 and 2 September 2008. Data included ambulance offload delay, time to see doctor, ED length of stay (LOS), admission requirement, access block, hospital LOS and in-hospital mortality. Logistic regression analysis was undertaken to identify predictors of hospital admission. RESULTS: Almost one-third of all 286037 ED presentations were via ambulance (n=79196) and 40.3% required admission. After increasing emergency capacity, the only outcome measure to improve was in-hospital mortality. Ambulance offload delay, time to see doctor, ED LOS, admission requirement, access block and hospital LOS did not improve. Strong predictors of admission before and after increased capacity included age >65 years, Australian Triage Scale (ATS) Category 1-3, diagnoses of circulatory or respiratory conditions and ED LOS >4h. With additional capacity, the odds ratios for these predictors increased for age >65 years and ED LOS >4h, and decreased for ATS category and ED diagnoses. CONCLUSIONS: Expanding ED capacity from 81 to 122 beds within a health service area impacted favourably on mortality outcomes, but not on time-related service outcomes such as ambulance offload time, time to see doctor and ED LOS. To improve all service outcomes, when altering (increasing or decreasing) ED bed numbers, the whole healthcare system needs to be considered.


Assuntos
Fortalecimento Institucional/organização & administração , Serviço Hospitalar de Emergência , Adolescente , Adulto , Idoso , Criança , Pré-Escolar , Feminino , Humanos , Lactente , Estudos Longitudinais , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Adulto Jovem
10.
Infect Control Hosp Epidemiol ; 35(1): 63-8, 2014 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-24334800

RESUMO

OBJECTIVE: To assess the relative importance of independent risk factors for peripheral intravenous catheter (PIVC) failure. METHODS: Secondary data analysis from a randomized controlled trial of PIVC dwell time. The Prentice, Williams, and Peterson statistical model was used to identify and compare risk factors for phlebitis, occlusion, and accidental removal. SETTING: Three acute care hospitals in Queensland, Australia. PARTICIPANTS: The trial included 3,283 adult medical and surgical patients (5,907 catheters) with a PIVC with greater than 4 days of expected use. RESULTS: Modifiable risk factors for occlusion included hand, antecubital fossa, or upper arm insertion compared with forearm (hazard ratio [HR], 1.47 [95% confidence interval (CI), 1.28-1.68], 1.27 [95% CI, 1.08-1.49], and 1.25 [95% CI, 1.04-1.50], respectively); and for phlebitis, larger diameter PIVC (HR, 1.48 [95% CI, 1.08-2.03]). PIVCs inserted by the operating and radiology suite staff had lower occlusion risk than ward insertions (HR, 0.80 [95% CI, 0.67-0.94]). Modifiable risks for accidental removal included hand or antecubital fossa insertion compared with forearm (HR, 2.45 [95% CI, 1.93-3.10] and 1.65 [95% CI, 1.23-2.22], respectively), clinical staff insertion compared with intravenous service (HR, 1.69 [95% CI, 1.30-2.20]); and smaller PIVC diameter (HR, 1.29 [95% CI, 1.02-1.61]). Female sex was a nonmodifiable factor associated with an increased risk of both phlebitis (HR, 1.64 [95% CI, 1.28-2.09]) and occlusion (HR, 1.44 [95% CI, 1.30-1.61]). CONCLUSIONS: PIVC survival is improved by preferential forearm insertion, selection of appropriate PIVC diameter, and insertion by intravenous teams and other specialists. TRIAL REGISTRATION: The original randomized controlled trial on which this secondary analysis is based is registered with the Australian New Zealand Clinical Trials Registry (http://www.anzctr.org.au; ACTRN12608000445370).


Assuntos
Cateterismo Periférico/instrumentação , Cateteres de Demora/efeitos adversos , Falha de Equipamento , Antibacterianos/administração & dosagem , Antipiréticos/administração & dosagem , Braço , Cateterismo Periférico/métodos , Remoção de Dispositivo , Análise de Falha de Equipamento , Feminino , Antebraço , Mãos , Humanos , Masculino , Pessoa de Meia-Idade , Análise Multivariada , Salas Cirúrgicas , Flebite/etiologia , Serviço Hospitalar de Radiologia , Fatores de Risco , Fatores Sexuais
11.
Lancet ; 380(9847): 1066-74, 2012 Sep 22.
Artigo em Inglês | MEDLINE | ID: mdl-22998716

RESUMO

BACKGROUND: The millions of peripheral intravenous catheters used each year are recommended for 72-96 h replacement in adults. This routine replacement increases health-care costs and staff workload and requires patients to undergo repeated invasive procedures. The effectiveness of the practice is not well established. Our hypothesis was that clinically indicated catheter replacement is of equal benefit to routine replacement. METHODS: This multicentre, randomised, non-blinded equivalence trial recruited adults (≥18 years) with an intravenous catheter of expected use longer than 4 days from three hospitals in Queensland, Australia, between May 20, 2008, and Sept 9, 2009. Computer-generated random assignment (1:1 ratio, no blocking, stratified by hospital, concealed before allocation) was to clinically indicated replacement, or third daily routine replacement. Patients, clinical staff, and research nurses could not be masked after treatment allocation because of the nature of the intervention. The primary outcome was phlebitis during catheterisation or within 48 h after removal. The equivalence margin was set at 3%. Primary analysis was by intention to treat. Secondary endpoints were catheter-related bloodstream and local infections, all bloodstream infections, catheter tip colonisation, infusion failure, catheter numbers used, therapy duration, mortality, and costs. This trial is registered with the Australian New Zealand Clinical Trials Registry, number ACTRN12608000445370. FINDINGS: All 3283 patients randomised (5907 catheters) were included in our analysis (1593 clinically indicated; 1690 routine replacement). Mean dwell time for catheters in situ on day 3 was 99 h (SD 54) when replaced as clinically indicated and 70 h (13) when routinely replaced. Phlebitis occurred in 114 of 1593 (7%) patients in the clinically indicated group and in 114 of 1690 (7%) patients in the routine replacement group, an absolute risk difference of 0·41% (95% CI -1·33 to 2·15%), which was within the prespecified 3% equivalence margin. No serious adverse events related to study interventions occurred. INTERPRETATION: Peripheral intravenous catheters can be removed as clinically indicated; this policy will avoid millions of catheter insertions, associated discomfort, and substantial costs in both equipment and staff workload. Ongoing close monitoring should continue with timely treatment cessation and prompt removal for complications. FUNDING: Australian National Health and Medical Research Council.


Assuntos
Infecções Relacionadas a Cateter/etiologia , Cateterismo Periférico/instrumentação , Adolescente , Adulto , Idoso , Infecções Relacionadas a Cateter/economia , Infecções Relacionadas a Cateter/epidemiologia , Infecções Relacionadas a Cateter/prevenção & controle , Cateterismo Periférico/efeitos adversos , Cateterismo Periférico/economia , Cateterismo Periférico/métodos , Remoção de Dispositivo/economia , Contaminação de Equipamentos/economia , Feminino , Custos de Cuidados de Saúde/estatística & dados numéricos , Humanos , Estimativa de Kaplan-Meier , Masculino , Pessoa de Meia-Idade , Flebite/economia , Flebite/epidemiologia , Flebite/etiologia , Flebite/prevenção & controle , Queensland/epidemiologia , Fatores de Tempo , Resultado do Tratamento , Adulto Jovem
12.
Clin Med Res ; 10(1): 7-14, 2012 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-21817123

RESUMO

OBJECTIVES: To determine the efficacy of non-invasive static magnetic stimulation (SMS) of the pelvic floor compared to placebo in the treatment of women aged 60 years and over with urinary incontinence for 6 months or more. SUBJECTS AND METHODS: A single-blinded randomized, placebo-controlled, parallel-group trial. Subjects were excluded if they had an implanted electronic device, had experienced a symptomatic urinary tract infection, or had commenced pharmacotherapy for the same in the previous 4 weeks, or if they were booked for pelvic floor or gynecological surgery within the next 3 months. Once written consent was obtained, subjects were randomly assigned to the active SMS group (n=50) or the placebo group (n=51). Treatment was an undergarment incorporating 15 static magnets of 800-1200 Gauss anterior, posterior, and inferior to the pelvis for at least 12 hours a day for 3 months. Placebo was the same protocol with inert metal disks replacing the magnets. Primary outcome measure was cessation of incontinence as measured by a 24-hour pad test. Secondary outcomes were frequency and severity of symptoms as measured by the Bristol Female Lower Urinary Tract Symptoms questionnaire (BFLUTS-SF), the Incontinence Severity Index, a Bothersomeness Visual Analog scale, and a 24-hour bladder diary. Data were collected at baseline and 12 weeks later. RESULTS: There were no statistically significant differences between groups in any of the outcome measures from baseline to 12 weeks. Initial evidence of subjective improvement in the treatment group compared to the placebo group was not sustained with sensitivity analysis. CONCLUSION: This study found no evidence that static magnets cure or decrease the symptoms of urinary incontinence. Additional work into the basic physics of the product and garment design is recommended prior to further clinical trials research.


Assuntos
Magnetoterapia/instrumentação , Magnetoterapia/métodos , Incontinência Urinária/terapia , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Pessoa de Meia-Idade , Diafragma da Pelve , Fatores de Tempo , Incontinência Urinária/fisiopatologia
13.
Med J Aust ; 194(4): S34-7, 2011 Feb 21.
Artigo em Inglês | MEDLINE | ID: mdl-21401486

RESUMO

OBJECTIVE: To assess the accuracy of data linkage across the spectrum of emergency care in the absence of a unique patient identifier, and to use the linked data to examine service delivery outcomes in an emergency department (ED) setting. DESIGN: Automated data linkage and manual data linkage were compared to determine their relative accuracy. Data were extracted from three separate health information systems: ambulance, ED and hospital inpatients, then linked to provide information about the emergency journey of each patient. The linking was done manually through physical review of records and automatically using a data linking tool (Health Data Integration) developed by the CSIRO (Commonwealth Scientific and Industrial Research Organisation). Match rate and quality of the linking were compared. SETTING: 10,835 patient presentations to a large, regional teaching hospital ED over a 2-month period (August - September 2007). RESULTS: Comparison of the manual and automated linkage outcomes for each pair of linked datasets demonstrated a sensitivity of between 95% and 99%; a specificity of between 75% and 99%; and a positive predictive value of between 88% and 95%. CONCLUSIONS: Our results indicate that automated linking provides a sound basis for health service analysis, even in the absence of a unique patient identifier. The use of an automated linking tool yields accurate data suitable for planning and service delivery purposes and enables the data to be linked regularly to examine service delivery outcomes.


Assuntos
Ambulâncias/estatística & dados numéricos , Serviço Hospitalar de Emergência/estatística & dados numéricos , Hospitalização/estatística & dados numéricos , Coleta de Dados , Serviços Médicos de Emergência/estatística & dados numéricos , Hospitais de Ensino/estatística & dados numéricos , Humanos , Avaliação de Resultados em Cuidados de Saúde/métodos , Avaliação de Resultados em Cuidados de Saúde/estatística & dados numéricos , Sistemas de Identificação de Pacientes , Queensland
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...