1.
Diabet Med ; 38(2): e14389, 2021 02.
Artigo em Inglês | MEDLINE | ID: mdl-32799407

RESUMO

AIMS: To evaluate the diagnostic relevance of autoantibodies against zinc transporter 8 (ZnT8) in schoolchildren from the general population as well as in people with autoimmune diabetes. METHODS: A total of 137 schoolchildren positive for at least one of the three major diabetes-associated autoantibodies, without diabetes heredity or preselection on HLA typing, from the Karlsburg Type 1 Diabetes Risk Study, as well as 102 people at type 1 diabetes onset, 88 people with latent autoimmune diabetes in adults and 119 people with type 2 diabetes, were analysed for different ZnT8 autoantibody variants. RESULTS: Zinc transporter 8 autoantibody positivity was found in 18% of autoantibody-positive schoolchildren, with a noticeable association with other autoantibodies associated with type 1 diabetes and disease progression. Furthermore, ZnT8 autoantibody positivity was associated with diabetes progression in schoolchildren positive for autoantibodies against insulinoma-associated antigen-2 (IA-2) and, importantly, in seven IA-2 autoantibody-negative schoolchildren. Additionally, ZnT8 autoantibodies were found in 56% of people with type 1 diabetes, predominantly directed against all three ZnT8 variants and comparable to schoolchildren with multiple autoantibodies. In contrast, ZnT8 autoantibodies were detected in 10% of people with latent autoimmune diabetes in adults, none of them with reactivity to all three isoforms. CONCLUSION: Zinc transporter 8 autoantibodies are useful markers for prediction of type 1 diabetes in a general population, further stratifying the risk of progression in autoantibody-positive children. ZnT8 autoantibodies are also important markers in adult-onset diabetes, with a completely different reaction pattern in type 1 diabetes in comparison to latent autoimmune diabetes in adults, and may therefore help to differentiate between the two forms.


Assuntos
Autoanticorpos/imunologia , Diabetes Mellitus Tipo 1/imunologia , Diabetes Mellitus Tipo 2/imunologia , Diabetes Autoimune Latente em Adultos/imunologia , Isoformas de Proteínas/imunologia , Transportador 8 de Zinco/imunologia , Adolescente , Adulto , Idoso , Criança , Diabetes Mellitus Tipo 1/epidemiologia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Medição de Risco
2.
Hernia ; 24(3): 661-668, 2020 06.
Artigo em Inglês | MEDLINE | ID: mdl-31745653

RESUMO

BACKGROUND: Three-dimensional (3D) laparoscopy improves the surgical skills of novice surgeons and positively affects the learning curve in experimental settings. This study aimed to investigate the effect of a 3D passive polarizing display (3DPPD) and a novel 3D head-mounted display (3DHMD; HMS-3000MT) on the performance of the first laparoscopic inguinal hernia repair by novices and compare both systems with standard high-definition 2D (HD2D) laparoscopy. METHODS: Patients with symptomatic inguinal hernia underwent transabdominal preperitoneal (TAPP) approach hernia repair using 3DHMD, 3DPPD, or a conventional HD2D laparoscopic system. All surgeries were performed for the first time by three laparoscopically novice surgeons. Operative performance was compared in terms of the time taken for mesh placement and peritoneal suturing under standardized conditions. Additionally, visual perception parameters and adverse effects were assessed. RESULTS: The use of both 3D techniques shortened the time required for mesh placement and peritoneal suturing compared with the conventional HD2D approach. Generally, 3D laparoscopy was superior to HD2D laparoscopy in terms of visual perception parameters such as depth perception, sharpness, ghosting, and contrast. However, compared with the use of HD2D laparoscopy, the use of 3DHMD significantly impaired a surgeon's comfort, with the greatest impairment caused by ear discomfort, headaches, and facial and physical discomforts. CONCLUSIONS: The 3DHMD and 3DPPD systems showed clear improvement in first hernia repair laparoscopy by novice surgeons in terms of surgical performance, as well as visual perception; however, the 3DHMD system was not superior to the 3DPPD system. The reduction in training time for new surgeons is obviously advantageous. In this respect, the 3D equipment may be a worthwhile investment.


Assuntos
Hérnia Inguinal/cirurgia , Herniorrafia/educação , Herniorrafia/instrumentação , Laparoscopia/educação , Laparoscopia/instrumentação , Competência Clínica , Feminino , Herniorrafia/métodos , Humanos , Imageamento Tridimensional , Laparoscopia/métodos , Curva de Aprendizado , Masculino , Pessoa de Meia-Idade
3.
Langenbecks Arch Surg ; 404(6): 711-716, 2019 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-31446471

RESUMO

PURPOSE: The aim of this long-term study was the comparison of appendiceal stump closure with polymeric clips or staplers with respect to perioperative costs and surgical outcome under routine conditions in a university centre. METHODS: For this retrospective chart review, a total of 618 patients undergoing laparoscopic appendectomy for suspected acute appendicitis between 2010 and 2017 were reviewed: 410 patients in the stapler group and 208 patients in the clip group. The database contained demographic data, operation time, inflammation parameters, closure method of the stump, surgeon status, length of hospital stay, and complications as well as histology reports. The costs were also compared. RESULTS: Clip application was more likely among younger patients (mean age 33.6 years vs. 41.7 years). Histopathological evidence for appendiceal pathology was found in 96.6% of patients in the clip group and 99.5% of patients in the stapler group. Laparoscopic appendectomy in the clip group was more frequently performed by resident physicians (69.2%) than in the stapler group (57.8%). The mean postoperative stay was 2.9 days in the clip group and 3.7 days in the stapler group. The use of the polymeric clip resulted in considerable cost savings (19.94€ vs. 348.70€). CONCLUSIONS: The use of polymeric clips for appendiceal stump closure during appendectomy is safe and effective. The base of the appendix is amenable to clipping in 32% of appendectomies in adult patients. This study supports the use of polymeric clips over staplers to decrease cost and environmental impact.


Assuntos
Apendicectomia/métodos , Apendicite/cirurgia , Laparoscopia/métodos , Instrumentos Cirúrgicos , Suturas , Técnicas de Fechamento de Ferimentos/instrumentação , Adulto , Feminino , Humanos , Tempo de Internação/estatística & dados numéricos , Masculino , Complicações Pós-Operatórias , Estudos Retrospectivos
4.
Diabet Med ; 32(8): 1008-16, 2015 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-25523979

RESUMO

AIMS: To investigate the occurrence of diabetes-associated autoantibodies and cumulative Type 1 diabetes risk over 18 years in a general population of schoolchildren. METHODS: In the Karlsburg Type 1 Diabetes Risk Study, 11 986 schoolchildren from north-eastern Germany without a family history of diabetes were screened for glutamic acid decarboxylase antibodies, insulinoma-associated antigen-2 antibodies and insulin autoantibodies by radioligand binding assay. Those children found to be autoantibody-positive were invited to follow-up examinations and HLA-DQB1 genotyping, and were followed for progression to Type 1 diabetes. RESULTS: At first follow-up, 119 children had single and 36 children had multiple autoantibodies. Of the multiple autoantibody-positive children, 33 had at least one diabetes-associated HLA-DQB1 allele (*02 and/or *0302). A total of 26 children progressed to Type 1 diabetes, of whom 22 had multiple autoantibodies. The male-to-female ratio of those who progressed to Type 1 diabetes was 1.6. The positive predictive value of multiple autoantibodies was 61.1% compared with only 23.7% for diabetes-associated HLA-DQB1 genotypes among all those who were autoantibody-positive. The cumulative risk was 59.7% after 10 years and 75.1% after 18 years for children with multiple autoantibodies compared with 1.2 and 22.6%, respectively, for children with single autoantibodies (P<0.001). Among the three examined autoantibodies, insulinoma-associated antigen-2 antibodies conferred the highest risk. CONCLUSIONS: The diabetes risk in schoolchildren with multiple autoantibodies was similar to the risk reported in other studies for genetically preselected probands; thus, a combined autoantibody-based screening could effectively identify at-risk individuals from the general population for future intervention trials.


Assuntos
Autoanticorpos/imunologia , Diabetes Mellitus Tipo 1/imunologia , Glutamato Descarboxilase/imunologia , Anticorpos Anti-Insulina/imunologia , Proteínas Repressoras/imunologia , Adolescente , Alelos , Criança , Diabetes Mellitus Tipo 1/epidemiologia , Diabetes Mellitus Tipo 1/genética , Feminino , Predisposição Genética para Doença , Genótipo , Alemanha/epidemiologia , Cadeias beta de HLA-DQ/genética , Humanos , Estudos Longitudinais , Masculino , Valor Preditivo dos Testes , Estudos Prospectivos , Fatores de Risco , Estudos Soroepidemiológicos , Distribuição por Sexo , Adulto Jovem
5.
J Microsc ; 242(1): 94-9, 2011 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-21118237

RESUMO

Examining the biocompatibility of implant materials includes the in vivo investigation of the local tissue response following implantation in experimental animals. By contrast to qualitative and semi-quantitative approaches often used in this field, a quantitative technique would facilitate a more accurate determination and better comparability of different studies. Therefore, this study aimed at evaluating the applicability of the free image analysis software ImageJ for fast, easy and reproducible quantification of the tissue response following implantation of titanium samples in rats with subsequent immunohistochemical examination of peri-implant tissue samples for monocytes and macrophages (ED1) and MHC class II positive antigen presenting cells (OX6). The quantification of positively stained cells in the vicinity of the implant pockets was based on a grid-supported manual count carried out using two ImageJ plugins (CellCounter, Grid) and resulted in a mean coefficient of variation of 13.8% (ED1) and 19.6% (OX6) between different investigators and 10.0% (ED1) and 13.8% (OX6) for repeated counting by the same investigator. In conclusion, ImageJ was found to be suitable for morphometric evaluation of the tissue response following implantation, particularly the analysis of discrete cellular events at the tissue-biomaterial interface. The procedure which was used is described in detail, and its advantages and disadvantages are discussed.


Assuntos
Materiais Biocompatíveis/normas , Processamento de Imagem Assistida por Computador/normas , Imuno-Histoquímica , Animais , Células Apresentadoras de Antígenos/imunologia , Materiais Biocompatíveis/efeitos adversos , Ectodisplasinas/metabolismo , Antígenos de Histocompatibilidade Classe II/metabolismo , Macrófagos/imunologia , Masculino , Teste de Materiais/métodos , Monócitos/imunologia , Próteses e Implantes/efeitos adversos , Ratos
6.
Acta Biomater ; 6(2): 676-83, 2010 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-19751851

RESUMO

Titanium (Ti) is an established biomaterial for bone replacement. However, facilitation of osteoblast attachment by surface modification with chemical groups could improve the implant performance. Therefore, this study aimed to evaluate the effect of a plasma polymerized allylamine (PPAAm) layer on the local inflammation in a rat model. Three series (RM76AB, RM78AB, RM77AB) of PPAAm-treated Ti plates were prepared using different plasma conditions. Twelve male LEW.1A rats received one plate of each series and one uncoated control plate implanted into the back musculature. After 7, 14 and 56 days, four rats were euthanized to remove the implants with surrounding tissue. Total monocytes/macrophages, tissue macrophages, T-cells and MHC-class-II-positive cells were morphometrically counted. On day 14, the macrophage/monocyte number was significantly higher for the controls than for the PPAAm samples. On day 56, the RM76AB and RM78AB samples had significantly lower numbers than RM77AB and the controls. The same was found for the tissue macrophages. No change over time and no differences between the implants were found for the T-cells. For the number of MHC-class-II-positive cells, a significant decrease was found only for the RM78AB implants between day 14 and day 56. Physico-chemical analysis of the PPAAm implants revealed that the RM77AB implants had the lowest water absorption, the highest nitrogen loss and the lowest oxygen uptake after sonication. These results demonstrate that the PPAAm samples and the controls were comparable regarding local inflammation, and that different plasma conditions lead to variations in the material properties which influence the tissue reaction.


Assuntos
Alilamina/toxicidade , Substitutos Ósseos , Inflamação/etiologia , Modelos Animais , Polímeros/toxicidade , Titânio/toxicidade , Animais , Antígenos de Histocompatibilidade Classe II/imunologia , Imuno-Histoquímica , Macrófagos/citologia , Masculino , Ratos , Ratos Endogâmicos Lew , Espectroscopia de Infravermelho com Transformada de Fourier , Análise Espectral/métodos , Linfócitos T/citologia , Raios X
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...