Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Adv Radiat Oncol ; 8(6): 101283, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37492779

RESUMO

Purpose: Postmastectomy radiation therapy (PMRT) reduces disease recurrence in appropriately selected patients but may compromise implant-based reconstruction. We investigated whether near-surface dose correlates with radiation-related toxic effects in these patients. Methods and Materials: Patients receiving PMRT at a single institution from 2016 to 2019 were retrospectively reviewed. Patient demographics and treatment information were collected. Three near-surface structures were retrospectively generated, bound by the chest wall tangent beam as well as the skin surface and the skin-3 mm contour (SR3), skin surface and skin-5 mm contour (SR5), or skin-5 and skin-10 mm contours. Dosimetric analysis of these near-surface contours was performed in 2 Gy intervals. Univariate and multivariate analyses were used to identify predictors of moist desquamation, grade 2+ chest wall pain, use of opiate pain medication, unplanned reconstructive surgery, and implant failure. Logistic regression for each outcome and near-surface contour was performed for receiver-operator area under the curve (AUC) analysis and the Youden J Statistic was used to determine the optimal threshold for each dosimetric parameter. Results: Of 126 patients reviewed, 109 met the study's eligibility criteria. Median follow-up was 2.3 years. Twenty-five patients (23%) underwent unplanned reconstructive surgery, and 10 (9.2%) experienced implant failure. Among clinical variables, low body mass index and history of smoking predicted unplanned surgery on univariate and multivariate analyses, and moist desquamation predicted grade 2+ chest wall pain. The top dosimetric parameters by AUC for moist desquamation, grade 2+ chest wall pain, use of opiates, unplanned reconstructive surgery, and implant failure were SR5 D10 cc (AUC = 0.701, optimal threshold 57.8 Gy, P < .001), SR3 D10 cc (AUC = 0.600, optimal threshold 56.8 Gy, P = .079), SR5 D10 cc (AUC = 0.642, optimal threshold 57.3 Gy, P = .041), SR3 V44 Gy (AUC = 0.711, optimal threshold 81%, P = .001), and SR3 V44 Gy (AUC = 0.688, optimal threshold 82%, P = .052), respectively. Conclusions: Near-surface dose correlates with moist desquamation and unplanned reconstructive surgery after PMRT. Further evaluation of prospective optimization of dosimetric parameters related to SR3 and SR5 should be considered.

2.
Adv Radiat Oncol ; 8(3): 101160, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-36896212

RESUMO

Purpose: Quantification of integral radiation dose delivered during treatment for prostate cancer is lacking. We performed a comparative quantification of dose to nontarget body tissues delivered via 4 common radiation techniques: conventional volumetric modulated arc therapy, stereotactic body radiation therapy, pencil-beam scanning proton therapy, and high-dose-rate brachytherapy. Methods and Materials: Plans for each radiation technique were generated for 10 patients with typical anatomy. For brachytherapy plans, virtual needles were placed to achieve standard dosimetry. Standard planning target volume margins or robustness margins were applied as appropriate. A "normal tissue" structure (entire computed tomography simulation volume minus planning target volume) was generated for integral dose computation. Dose-volume histogram parameters for targets and normal structures were tabulated. Normal tissue integral dose was calculated by multiplying normal tissue volume by mean dose. Results: Normal tissue integral dose was lowest for brachytherapy. Pencil-beam scanning protons, stereotactic body radiation therapy, and brachytherapy resulted in 17%, 57%, and 91% absolute reductions compared with standard volumetric modulated arc therapy, respectively. Mean nontarget tissues receiving 25%, 50%, and 75% of the prescription dose were reduced by 85%, 76%, and 83% for brachytherapy relative to volumetric modulated arc therapy, by 79%, 64%, and 74% relative to stereotactic body radiation therapy, and 73%, 60%, and 81% relative to proton therapy. All reductions observed using brachytherapy were statistically significant. Conclusions: High-dose-rate brachytherapy is an effective technique for reducing dose to nontarget body tissues relative to volumetric modulated arc therapy, stereotactic body radiation therapy, and pencil-beam scanning proton therapy.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...