Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 14 de 14
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Zhonghua Shao Shang Za Zhi ; 29(5): 454-8, 2013 Oct.
Artigo em Chinês | MEDLINE | ID: mdl-24360004

RESUMO

A 55-year-old male patient suffered from severe high-voltage electric burn with an area of 20%TBSA full-thickness injury. The injury involved the distal end of left upper limb, right trunk, and whole abdominal wall. Fracture of the 7th-10th ribs was found in the right side of chest, with perforation of abdominal cavity, and bilateral pleural effusion was found. Part of the small intestine was necrotic and exposed. At the early stage, xeno-acellular dermal matrix was grafted after debridement of abdominal wound; peritoneal lavage was performed; negative pressure drainage was performed in orificium fistula of intestine for promoting the adhesion between perforated intestine and abdominal scar. Two orificium fistulas formed after closure of abdominal granulation wound by autologous skin grafting. Eschar of chest wall and denatured ribs were retained. The risk of infection of thoracic cavity was decreased by promoting the adhesion between lung tissue and chest wall. During the treatment, the patient was diagnosed with Henoch-Schonlein purpura nephritis by renal biopsy, with the symptoms of purpura in the lower limbs, heavy proteinuria, severe hypoalbuminemia, edema, etc. After control of kidney damage by immunosuppressive treatment instead of glucocorticoid, alleviation of the levels of proteinuria and blood albumin, free latissimus dorsi myocutaneous flap was excised to repair chest wall, and free skin graft was excised to repair intestinal fistula. After all the wounds were successfully covered, the patient was treated with glucocorticoid combined with immunosuppressants for more than 1 year. The patient was followed up for 3 years, and his renal function was completely recovered with satisfactory clinical outcome.


Assuntos
Traumatismos Abdominais/cirurgia , Queimaduras por Corrente Elétrica/cirurgia , Vasculite por IgA/cirurgia , Nefrite/cirurgia , Traumatismos Torácicos/cirurgia , Cavidade Abdominal , Traumatismos Abdominais/complicações , Queimaduras por Corrente Elétrica/complicações , Humanos , Vasculite por IgA/complicações , Masculino , Pessoa de Meia-Idade , Nefrite/complicações , Cavidade Torácica , Traumatismos Torácicos/complicações
2.
J Spinal Disord Tech ; 25(2): 123-8, 2012 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-21430565

RESUMO

STUDY DESIGN: Low elastic modulus expandable pedicle screw (L-EPS) was inserted into osteoporotic sheep. Biomechanical tests, micro-CT analysis and histologic observation were performed. OBJECTIVE: To find out whether the L-EPS can further improve fixation strength compared to the expandable pedicle screws (EPS) in osteoporotic sheep spine. The screw-bone interface is also detected by micro-computed tomography (CT) and histologic techniques. SUMMARY OF BACKGROUND DATA: There are some studies on EPS in vivo; however, no earlier study has focused on the elastic modulus of EPS, especially in osteoporosis. METHODS: Twelve months after ovariectomy, bilateral pedicles of lumbar vertebrae (L1 to L5) of 4 female sheep were fixed with EPSs. The L-EPS and EPS were randomly placed into each pedicle and then were expanded. Six months later, the sheep were sacrificed and biomechanical tests, micro-CT analysis, and histologic observation were conducted on the isolated specimen vertebrae. RESULTS: Twelve months after ovariectomy, animal model of osteoporosis was established successfully. The axial pull-out strength in L-EPS group was significantly enhanced compared with that in the EPS group (P < 0.05). Micro-CT reconstruction and analysis showed that there was more bone around the L-EPS group compared with those in EPS group (P < 0.05), meanwhile the more homogeneous bone formation distribution around the screws was found in the L-EPS group. Histologic observation showed that newly formed bone extended along the expandable fissures and grew into the center of EPS; meanwhile, the more direct contact and the less fibrous tissue on the screw-bone interface were observed in the L-EPS group. CONCLUSIONS: The L-EPS can further improve the biomechanical fixation strength of EPS in the osteoporotic sheep. The screw elastic matching with surrounding bone is helpful to distribute stress uniformly, relieve the stress shielding effect, and strengthen the screw-bone interface. Although the experience with the L-EPS is very limited and preliminary, results to date indicate that it is of value in treating patients with osteoporosis and warrants further study.


Assuntos
Parafusos Ósseos , Vértebras Lombares/cirurgia , Procedimentos Ortopédicos/instrumentação , Osteoporose/cirurgia , Animais , Fenômenos Biomecânicos , Feminino , Vértebras Lombares/diagnóstico por imagem , Osteoporose/diagnóstico por imagem , Radiografia , Ovinos
3.
J Surg Res ; 176(1): 95-101, 2012 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-21704325

RESUMO

BACKGROUND: Two- or three-vertebra fixation techniques are both used in the treatment of spondylolisthesis. However, the number of spinal segments that should be implanted in spondylolisthesis reduction and fixation is still controversial, and there are no published reports on stress distribution on the screws with 2- or 3-vertebra fixation techniques. Understanding stress distribution in screws would be of potential great clinical importance and supply more biomechanical evidence in surgery. The aim of this study was to compare and quantitatively analyze the stress distribution on the screws in 2- or 3-vertebra fixation techniques in cadaveric models of spondylolisthesis. MATERIALS AND METHODS: Sixteen fresh specimens of human lumbar spines were used in this study. The spondylolisthesis model was generated by Panjabi method and fixed with the SINO universal spine system by 2- (group A) or 3-vertebra (group B) fixation technique. Rectangular electrical resistance strain gauges were fixed at upper and lower surface of the root of screws bilaterally. The samples were tested under flexion/extension, left/right lateral bending, and axial compression loading. Stress on the screws was measured by strain gauge monitor, respectively. RESULTS: Under the five different loading conditions, the stress could be compressive stress or tensile stress. Under the compression, flexion, and bending loading condition, the stress in reduction screws in group A is higher than in group B (P < 0.01). However, under the extension loading condition, stress of lower surface in reduction screws in group A is 49% lower than in group B. With regard to the anchor screws, under flexion and lateral bending conditions, stress in group A is lower than in group B (P < 0.05). Under compression and extension loading conditions, stress in group A is slightly higher than in group B, but no significant difference is detected. CONCLUSIONS: In most loading conditions, stress in reduction screws in 2-vertebra fixation technique was higher than in 3-vertebra fixation technique. The 3-vertebra fixation technique might effectively reduce stress on the reduction screws, and decrease the probability of fatigue fractures of the screws.


Assuntos
Parafusos Ósseos , Vértebras Lombares/cirurgia , Fusão Vertebral/instrumentação , Fusão Vertebral/métodos , Espondilolistese/cirurgia , Estresse Mecânico , Adulto , Fenômenos Biomecânicos , Cadáver , Feminino , Fraturas de Estresse/epidemiologia , Humanos , Fixadores Internos/normas , Masculino , Teste de Materiais , Pessoa de Meia-Idade , Modelos Anatômicos , Fatores de Risco
4.
J Orthop Sci ; 16(1): 99-104, 2011 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-21293893

RESUMO

OBJECTIVE: The purpose of this study was to analyze the local treatment effects of rhBMP-2 combined with fibrin sealant (FS) on bone mineral density, microarchitectural and mechanical properties in osteoporotic ovine spine. MATERIALS AND METHODS: Postmenopausal osteoporosis was induced in eight sheep through ovariectomy (OVX) and a low-calcium diet for a period of 12 months. According to the Latin square design, L3-L6 vertebrae were randomly assigned to four treatment groups: A (rhBMP-2/FS), B (rhBMP-2), C (FS) and D (blank control). All materials were injected into the assigned vertebra transpedicularly. All animals were euthanized 3 months after treatment. Bone mineral density (BMD), microarchitectural and mechanical properties were assessed. ANOVA analysis of variance was used to determine effects of rhBMP-2/FS (α = 0.05). RESULTS: The BMD in group A (rhBMP-2/FS) was 18.8, 30.4 and 27.9% higher than that in group B, C and D, respectively. Analysis of bone structure by micro-CT revealed higher trabecular bone volume (BV/TV), trabecular thickness (Tb.Th) and trabecular number (Tb.N) in the rhBMP-2/FS group (P < 0.01). In addition, vertebrae treated with rhBMP-2/FS exhibited higher yield stress, ultimate stress, energy absorption and bone modulus compared to the control groups. CONCLUSIONS: Local administration of rhBMP-2/FS showed a positive trend in improving BMD, microarchitectural parameters and mechanical strength of osteoporotic vertebra. Slow release of rhBMP-2 using FS appeared to be an effective method of protein delivery. The local treatment of osteoporosis in the spine can increase bone strength and reduce fracture risk quickly.


Assuntos
Proteína Morfogenética Óssea 2/administração & dosagem , Vértebras Lombares/fisiopatologia , Osteoporose/tratamento farmacológico , Pós-Menopausa , Absorciometria de Fóton , Animais , Fenômenos Biomecânicos , Densidade Óssea , Preparações de Ação Retardada , Modelos Animais de Doenças , Feminino , Vértebras Lombares/diagnóstico por imagem , Osteoporose/metabolismo , Osteoporose/fisiopatologia , Proteínas Recombinantes , Carneiro Doméstico , Resultado do Tratamento
5.
J Spinal Disord Tech ; 24(4): 235-41, 2011 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-20844452

RESUMO

STUDY DESIGN: Augmentation of pedicle screws with calcium sulfate cement (CSC) was performed in osteoporotic sheep. Biomechanical tests, micro-computed tomography (CT) analysis, and histological observation were performed. OBJECTIVE: To investigate the long-term biomechanical performance of pedicle screws augmented with CSC in vivo and evaluated the screw-bone interfacial bonding with micro-CT and histological techniques. SUMMARY OF BACKGROUND DATA: There is little information on the long-term biomechanical performance and screw-bone interfacial bonding of pedicle screws augmented with CSC in osteoporosis in vivo. METHODS: Twelve months after ovariectomy, bilateral pedicles of lumbar vertebrae (L1 to L5) of 6 female sheep were fixed with pedicle screws. One pedicle of each vertebral body was treated with a screw augmented with CSC (CSC group) and the contralateral pedicle was treated with a screw without any augmentation (control group). Three months later, the sheep were killed and biomechanical tests, micro-CT analysis, and histological observation were conducted on the isolated specimen vertebrae. RESULTS: Twelve months after ovariectomy, animal model of osteoporosis was established successfully. Both the axial and vertical stabilities of the pedicle screws in CSC group were significantly enhanced compared with those in the control group (P<0.05). Micro-CT reconstruction and analysis showed that there were more bone trabeculae around the screws in CSC group compared with those in control group (P<0.05), and the bone trabeculae were significantly denser than those in control group (P<0.05). Histological observation showed that CSC was completely degradated and bone trabeculae around the screws in CSC group were more and denser than that in the control group. Bone trabeculae held the screws tightly without any interspaces between screw and bone, which formed strong bonding between bone and screw. CONCLUSIONS: CSC can significantly improve screw-bone interfacial bonding and strengthen the long-term stability of pedicle screws in osteoporotic sheep. Augmentation with CSC may be a potentially useful method to increase the stability of pedicle screws in patients with osteoporosis.


Assuntos
Cimentos Ósseos/uso terapêutico , Parafusos Ósseos , Sulfato de Cálcio/administração & dosagem , Vértebras Lombares/cirurgia , Osteoporose/cirurgia , Animais , Fenômenos Biomecânicos/fisiologia , Cimentos Ósseos/química , Parafusos Ósseos/normas , Modelos Animais de Doenças , Feminino , Vértebras Lombares/fisiologia , Osteoporose/fisiopatologia , Ovinos
6.
J Spinal Disord Tech ; 24(5): 313-7, 2011 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-20975595

RESUMO

STUDY DESIGN: An in-vitro cadaver-based measurement using microcomputed tomography. OBJECTIVES: To evaluate the safety of removal of expandable pedicle screws (EPSs) in human vertebral bodies after a long (6 mo) insertion time. SUMMARY OF BACKGROUND DATA: Transpedicular fixation is commonly used for posterior fixation of the spine. Osteoporotic patients are in high risk of internal fixation failure. EPS is an available device for increasing transpedical fixation in the osteoporotic spine. However, it is unclear that how much the diameter of the expanding screw tip increases in the human vertebral body, and no reports have assessed the potential for fracture of the pedicle when the EPS is removed. Therefore, the safety of removal of EPS needs to be evaluated. METHODS: In this study, 6.50 mm EPSs were inserted into cadaveric lumbar vertebrae. The maximum diameters of expansion, the maximum diameters of the EPS trajectories, and the diameters of the EPS trajectories in the pedicles were measured using microcomputed tomography imaging and 3-dimensional reconstruction. Regions of interest of the same size adjacent to the EPS in the pedicle and in the vertebral body were reconstructed and analyzed using the same thresholds (1000). Bone volume divided by total volume (BV/TV) in these regions of interest was determined. RESULTS: The maximum diameter of expansion of the EPSs in the vertebral body was 7.63 mm, a 17.38% increase from the original diameter. The maximum diameter of the EPS trajectory and the diameter of the EPS trajectory in the pedicle were 7.56 mm and 7.09 mm, respectively, increases of 16.31% and 9.08%. The differences were statistically significant (P < 0.05). In the pedicle, there was a negative correlation between the diameter of the EPS trajectory and the BV/TV along the EPS trajectory (r = -0.88; P = 0.002). In the vertebral body, a negative correlation occurred between the maximum expansion diameter of the EPS and vertebral BV/TV (r = -0.85; P = 0.004). CONCLUSIONS: The EPS could be reliably removed after expansion without fracturing the pedicle. Furthermore, the BV/TV had an important influence on the degree of expansion of EPS and whether or not pedicle fracture occurs.


Assuntos
Parafusos Ósseos/normas , Fixadores Internos/normas , Vértebras Lombares/diagnóstico por imagem , Vértebras Lombares/cirurgia , Fusão Vertebral/instrumentação , Fusão Vertebral/métodos , Tomografia Computadorizada por Raios X/métodos , Idoso , Cadáver , Humanos , Masculino , Complicações Pós-Operatórias/etiologia , Complicações Pós-Operatórias/prevenção & controle
7.
J Spinal Disord Tech ; 24(7): 444-50, 2011 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-21150659

RESUMO

STUDY DESIGN: The application of rapid prototyping (RP) technique for improving accuracy of pedicle screw placement in congenital scoliosis is described in this study. OBJECTIVE: To compare the accuracy and safety of pedicle screw placement in congenital scoliosis using the RP technique versus the conventional fluoroscopy. SUMMARY OF BACKGROUND DATA: Maldeveloped vertebral components in congenital scoliosis leads to prolonged operation time and higher rate of screw misplacement. RP technique can enhance preoperative and perioperative planning. No data are available on the accuracy of pedicle screw fixation using the RP technique. METHODS: Sixty-two consecutive patients with hemivertebra had undergone posterior-only hemivertebra resection. Pedicle screws were implanted either by the conventional intraoperative fluoroscopy technique (C-arm group; n=28) or the RP technique (RP group; n=34). Accuracy of pedicle screw placement was compared by postoperative computed tomographic scan. RESULTS: Seventy of 677 inserted screws were found to be misplaced, showing an overall accuracy of 89.7% (90.8% in the thoracic spine and 87.4% in the lumbar spine). In the C-arm group, 86.1% (167 of 194) and 82.0% (82 of 100) of screws were accurately placed in the thoracic and lumbar spine, respectively. While in the RP group, the respective screw placement accuracies were 94.4% (238 of 252) and 91.6% (120 of 131). In the C-arm and the RP groups, 94.8% (279 of 294) and 97.9% (375 of 383) of the screws were within the safety zone, respectively. Compared with the fluoroscopy method, the RP-assisted technique showed a shorter operation time and higher scoliosis correction rate. No neurovascular-related complication was observed with this technique during the study. CONCLUSION: The application of RP technique in congenital scoliosis can reduce the operation time, the risk of screw misplacement and its consequent complications. The use of RP technique in congenital scoliosis is safe and efficacious.


Assuntos
Parafusos Ósseos/normas , Cuidados Pré-Operatórios/normas , Escoliose/cirurgia , Índice de Gravidade de Doença , Fusão Vertebral/normas , Adolescente , Criança , Pré-Escolar , Seguimentos , Humanos , Complicações Pós-Operatórias/diagnóstico por imagem , Cuidados Pré-Operatórios/métodos , Escoliose/congênito , Escoliose/diagnóstico por imagem , Fusão Vertebral/métodos , Tomografia Computadorizada por Raios X , Adulto Jovem
8.
J Spinal Disord Tech ; 24(5): 318-24, 2011 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-21150670

RESUMO

STUDY DESIGN: Partial screw augmentation was carried out by the injection of polymethylmethacrylate (PMMA) through the novel tap into the bone tissue in sheep vertebrae in vitro. Biomechanical tests and microcomputerized tomography analysis were done. OBJECTIVE: To evaluate the stability of the screw and the interface between the bone and the screw in partial screw augmentation. SUMMARY OF BACKGROUND DATA: Augmentation of the pedicle screw with PMMA improves screw stability significantly. However, it results in the full envelopment of the screw by PMMA and the formation of a full "screw-PMMA-bone" interface, which may increase the difficulties in screw removal. Therefore, it is urgent to develop a novel method to augment screw fixation, which avoids full wrapping of PMMA around the screw and facilitates screw removal. We designed a novel tap with an inner hollow and the multiple lateral apertures. METHODS: A total of 78 fresh adult sheep lumbar vertebrae were randomly divided into 3 groups. No screw augmentation was performed in the control group. The pilot hole was filled with PMMA in the full screw augmentation group, whereas PMMA was injected through the tap into the bone tissue in the partial screw augmentation group. Pedicle screws were ultimately inserted into all the holes. Axial pullout tests, cyclic bending tests, and microcomputerized tomography analysis were carried out 24 hours after screw fixation. RESULTS: Both partial screw augmentation and full screw augmentation caused significant increase in pedicle screw stability compared with the control group in both the axial pullout tests and the cyclic bending resistance tests. Partial screw augmentation resulted in the formation of a partial "screw-bone" interface and a partial screw-PMMA-bone interface, which seems like 3 anchors or roots extending and fixing in the bone tissue in a cross section of the interface. It was obviously different from the complete screw-PMMA-bone interface with a complete PMMA mantle around the screw in the full screw augmentation group. CONCLUSIONS: Our proof-of-concept study showed that partial screw augmentation could enhance pedicle screw fixation strength, avoided the full surrounding of the PMMA around the screw, and generated a partial screw-PMMA-bone and a partial screw-bone interface. Partial screw augmentation may be a potential method to augment pedicle screw stability.


Assuntos
Cimentos Ósseos/uso terapêutico , Fixadores Internos/normas , Polimetil Metacrilato/uso terapêutico , Falha de Prótese/efeitos adversos , Fusão Vertebral/instrumentação , Coluna Vertebral/cirurgia , Animais , Fenômenos Biomecânicos/fisiologia , Técnicas In Vitro , Modelos Animais , Ovinos , Fusão Vertebral/métodos
9.
Clin Invest Med ; 33(6): E368-74, 2010 Dec 01.
Artigo em Inglês | MEDLINE | ID: mdl-21134338

RESUMO

PURPOSE: To investigate the clinical abstract and radiographic outcome of multi-axial expandable pedicle screws (MEPS) in patients with osteoporosis. METHODS: One hundred and twenty-five consecutive patients received MEPS from the UPASS spinal fixation system to obtain thoracolumbar or lumbosacral stabilization. All patients underwent bone mineral density (BMD) scans. The indications for use of the MEPS were spinal diseases with severe osteoporosis (degenerative diseases 46 cases, compression fractures 28 cases, lumbar tuberculosis 27 cases and revision spine surgery 24 cases). The pre-operative and three months post-operative functional evaluations were graded with JOA and VAS scoring system. One week, six months and 12 months after surgery, plain film and three-dimensional CT scans were obtained to evaluate the spinal fusion and fixation effectiveness of MEPS. RESULTS: The mean follow-up period was 18 months (ranged from 6 to 33 months). All patients suffered from severely osteoporosis with a decrease of 25.3% in BMD. The pre-operative JOA and VAS scores were 11.3±3.0 and 6.7±1.8 mm, respectively. Three months after operation, the JOA and VAS scores were 25.2±2.0 and 2.3±1.7 mm. The recovery rate was 78.1±11.5% and the clinical results were satisfying. There were no instances of screw loosening or pullout of the MEPS and the screw-bone interface was excellent. The radiographic results showed that bone healing, both around the screws and inter-vertebral, was achieved. CONCLUSION: In osteoporosis spine surgery, excellent bone-screw interface and fixation strength can be achieved by using MEPS. MEPS are a novel approach to increase the pedicle screw fixation in osteoporotic and revision spine surgeries.


Assuntos
Parafusos Ósseos , Osteoporose/diagnóstico por imagem , Osteoporose/cirurgia , Coluna Vertebral/diagnóstico por imagem , Coluna Vertebral/cirurgia , Adulto , Idoso , Densidade Óssea , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Osteoporose/metabolismo , Radiografia , Coluna Vertebral/metabolismo , Resultado do Tratamento
10.
J Surg Res ; 164(2): e253-6, 2010 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-20934724

RESUMO

BACKGROUND: Epidural leaks or canal intrusion are often found in vertebroplasty, which can lead to several complications. To the best of our knowledge, this is the first report on using two-stage injection procedure in vertebroplasty to reduce cement leakage rate. MATERIALS AND METHODS: Fifty cadaveric vertebrae (L1-L5) were harvested from 10 osteoporotic lumbar spines. The age of the female donors ranged from 60 to 72 y; the bone mineral density (BMD) of the vertebrae ranged from 0.226 to 0.631 g/cm(2). Polymethylmethacrylate (PMMA) was injected into vertebral bodies by either novel two-stage injection (1 mL cement was injected at first stage and another 4 mL cement was injected at second stage after the cement solidified) or standard conventional injection procedure. After injection, all vertebral bodies (VBs) were checked for cement leakage into spinal canal by vision and fluoroscopy. Cement leakage rates were recorded. RESULTS: The two-stage injection procedure resulted in a significant decrease in the epidural or canal leakage rate (P = 0.032). In addition, the paravertebral leakage rate was significantly higher in two-stage injection procedure group (48%) than in conventional injection procedure group (16%). However, no significant difference was found for the total cement leakage rate between the two groups. CONCLUSION: Compared with conventional procedure, the two-stage injection procedure in vertebroplasty decreased incidence of epidural and canal leaks. The first-stage injecting PMMA can be a barrier to the epidural extravasation of cement during vertebroplasty. Further in vivo and clinical researches are needed to evaluate the new procedure.


Assuntos
Complicações Intraoperatórias/prevenção & controle , Vértebras Lombares/cirurgia , Osteoporose/cirurgia , Vertebroplastia/métodos , Idoso , Fístula Anastomótica/epidemiologia , Cadáver , Feminino , Humanos , Injeções/métodos , Vértebras Lombares/diagnóstico por imagem , Vértebras Lombares/patologia , Masculino , Pessoa de Meia-Idade , Osteoporose/diagnóstico por imagem , Osteoporose/patologia , Radiografia , Vertebroplastia/efeitos adversos
11.
Med Eng Phys ; 30(9): 1112-8, 2008 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-18595763

RESUMO

Osteoporotic/osteopenia fractures occur most frequently in trabeculae-rich skeletal sites. The purpose of this study was to use a high-resolution micro-computed tomography (micro-CT) and dual energy X-ray absorptionmeter (DEXA) to investigate the changes in micro-architecture and bone mineral density (BMD) in a sheep model resulted from ovariectomy (OVX). Biomechanical tests were performed to evaluate the strength of the trabecular bone. Twenty adult sheeps were randomly divided into three groups: sham group (n=8), group 1 (n=4) and group 2 (n=8). In groups 1 and 2, all sheep were ovariectomized (OVX); in the sham group, the ovaries were located and the oviducts were ligated. In all animals, BMD for lumbar spine was obtained during the surgical procedure. BMD at the spine, femoral neck and femoral condyle was determined 6 months (group 1) and 12 months (group 2) post-OVX. Lumbar spines and femora were obtained and underwent BMD scan, micro-CT analysis. Compressive mechanical properties were determined from biopsies of vertebral bodies and femoral condyles. BMD, micro-architectural parameters and mechanical properties of cancellous bone did not decrease significantly at 6 months post-OVX. Twelve months after OVX, BMD, micro-architectural parameters and mechanical properties decreased significantly. The results of linear regression analyses showed that trabecular thickness (Tb.Th) (r=0.945, R2=0.886) and bone volume fraction (BV/TV) (r=0.783, R2=0.586) had strong (R2>0.5) correlation to compression stress. In OVX sheep, changes in the structural parameters of trabecular bone are comparable to the human situation during osteoporosis was induced. The sheep model presented seems to meet the criteria for an osteopenia model for fracture treatment with respect to morphometric and mechanical properties. But the duration of OVX must be longer than 12 months to ensure the animal model can be established successfully.


Assuntos
Densidade Óssea , Osso e Ossos/diagnóstico por imagem , Osso e Ossos/fisiopatologia , Modelos Animais de Doenças , Osteoporose/diagnóstico por imagem , Osteoporose/fisiopatologia , Ovariectomia , Animais , Fenômenos Biomecânicos , Força Compressiva , Módulo de Elasticidade , Feminino , Humanos , Radiografia , Ovinos , Estresse Mecânico
12.
Chin J Traumatol ; 11(2): 72-7, 2008 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-18377708

RESUMO

OBJECTIVE: To investigate the properties of screw-bone interface of expansive pedicle screw (EPS) in osteoporotic sheep by micro-CT and histological observation. METHODS: Six female sheep with bilateral ovariectomy-induced osteoporosis were employed in this experiment. After EPS insertion in each femoral condyle, the sheep were randomly divided into two groups: 3 sheep were bred for 3 months (Group A), while the other 3 were bred for 6 months (Group B). After the animals being killed, the femoral condyles with EPS were obtained, which were three-dimensionally-imaged and reconstructed by micro-CT. Histological evaluation was made thereafter. RESULTS: The trabecular microstructure was denser at the screw-bone interface than in the distant parts in expansive section, especially within the spiral marking. In the non-expansive section, however, there was no significant difference between the interface and the distant parts. The regions of interest (ROI) adjacent to EPS were reconstructed and analyzed by micro-CT with the same thresholds. The three-dimensional (3-D) parameters, including tissue mineral density (TMD), bone volume fraction (BVF, BV/TV), bone surface/bone volume (BS/BV) ratio, trabecular thickness (Tb.Th), and trabecular separation (Tb.Sp), were significantly better in expansive sections than non-expansive sections (P less than 0.05). Histologically, newly-formed bony trabeculae crawled along the expansive fissures and into the center of EPS. The newly-formed bones, as well as the bones at the bone-screw interface, closely contacted with the EPS and constructed four compartments. CONCLUSIONS: The findings of the current study, based on micro-CT and histological evaluation, suggest that EPS can significantly provide stabilization in osteoporotic cancellous bones.


Assuntos
Parafusos Ósseos , Osso e Ossos/diagnóstico por imagem , Osso e Ossos/patologia , Osteoporose/diagnóstico por imagem , Osteoporose/patologia , Tomografia Computadorizada por Raios X , Animais , Feminino , Ovinos
13.
Zhonghua Wai Ke Za Zhi ; 45(18): 1271-3, 2007 Sep 15.
Artigo em Chinês | MEDLINE | ID: mdl-18067743

RESUMO

OBJECTIVE: To investigate the properties of screw-bone interface of expansive pedicle screw (EPS) in osteoporotic sheep using micro-CT and histology. METHODS: Six female sheep with bilateral ovariectomy-induced osteoporosis were employed in this experiment and were randomly assigned into 2 groups: A and B. After EPS insertion in each femoral condyles, sheep in group A were bred for 3 months, while those in group B 6 months. Femoral condyles with EPS were 3D-imaged and reconstructed by micro-CT. Histology was evaluated thereafter. RESULTS: The trabecular microstructure was denser at the screw-bone interface than in the distant parts in expansive section, especially within spiral marking. In the non-expansive section, however, there was no significant difference between the interface and the distant parts. The regions of interest (ROI) adjacent to EPS were reconstructed and analyzed by micro-CT using the same thresholds. The 3D-parameters generated, including tissue mineral density (TMD), bone volume fraction (BVF, BV/TV), bone surface/bone volume (BS/BV) ratio, trabecular thickness (Tb.Th), and trabecular separation (Tb.Sp), were significantly better in expansive than in non-expansive sections (P < 0.05). Histologically, newly formed bone trabeculae crawled along the expansive fissures and into the center of EPS. The newly formed bones, as well as the bone at the bone-screw interface, closely contacted the EPS and constructed four compartments. CONCLUSIONS: Based on micro-CT and histological evaluation, the study suggest that EPS can significantly provide stabilization in osteoporotic cancellous bone.


Assuntos
Parafusos Ósseos , Fêmur/diagnóstico por imagem , Osteoporose/patologia , Tomografia Computadorizada por Raios X/métodos , Animais , Densidade Óssea , Modelos Animais de Doenças , Feminino , Fêmur/metabolismo , Fêmur/cirurgia , Osteoporose/etiologia , Osteoporose/cirurgia , Ovariectomia/efeitos adversos , Reprodutibilidade dos Testes , Ovinos
14.
Spine (Phila Pa 1976) ; 32(22): 2437-42, 2007 Oct 15.
Artigo em Inglês | MEDLINE | ID: mdl-18090082

RESUMO

STUDY DESIGN: Fibrin sealant (FS) combined with or without growth factor was used to improve the micro-architectural and biomechanical properties of vertebral body in osteoporotic ovine spine. OBJECTIVE: To analyze the treatment effects of bovine bone morphogenetic protein (bBMP) combined with FS on osteopenic ovine vertebral architecture, bone mineral density, and biomechanics in vivo. SUMMARY OF BACKGROUND DATA: Vertebroplasty and kyphoplasty were used to treat spinal osteoporosis. They can increase strength of vertebrae physically. However, each has specific disadvantages. bBMP could rapidly increasing bone formation and suppressing bone resorption, but little is known about its effect on ovariectomized-induced osteoporosis. METHODS: Six sheep underwent ovariectomy and were placed on a low-calcium diet. Twelve months later, according to Ladin square design, L4-L6 vertebrae in all sheep were randomly assigned to 3 treatment groups: A (30 mg bBMP/1.5 mL FS), B (30 mg bBMP) and C (1.5 mL FS). All materials were injected into the assigned vertebra transpedicularly. Animals were killed 3 months after injection, and bone mineral density (BMD), biomechanics, and histomorphometry were assessed. Analysis of variance was used to determine effects of bBMP/FS (alpha = 0.05). RESULTS: The BMD in Group 1 was 17.1% and 14.7% higher than that in Group 2 and Group 3, respectively. The micro-CT reconstruction analysis showed that the density and connectivity of trabecular bone in bBMP/FS treated vertebrae were higher than those in control groups. The mechanical properties (yield stress, ultimate stress, energy absorption, bone modulus) of the vertebrae were also significantly higher. In this study, local bBMP/FS treatment showed a positive trend in improving BMD, histomorphometric parameters, and mechanical strength of osteoporotic vertebra. Slow release of bBMP using FS appeared to be an effective method of protein delivery. CONCLUSION: The use of bBMP/FS in the treatment of vertebral osteoporosis in an attempt to enhance bone strength merits further study.


Assuntos
Proteínas Morfogenéticas Ósseas/uso terapêutico , Adesivo Tecidual de Fibrina/uso terapêutico , Osteoporose Pós-Menopausa/tratamento farmacológico , Osteoporose Pós-Menopausa/cirurgia , Vertebroplastia/métodos , Animais , Densidade Óssea/efeitos dos fármacos , Desenvolvimento Ósseo/efeitos dos fármacos , Reabsorção Óssea/tratamento farmacológico , Reabsorção Óssea/patologia , Reabsorção Óssea/prevenção & controle , Modelos Animais de Doenças , Esquema de Medicação , Feminino , Humanos , Injeções , Osteogênese/efeitos dos fármacos , Osteoporose Pós-Menopausa/patologia , Carneiro Doméstico , Coluna Vertebral/efeitos dos fármacos , Coluna Vertebral/patologia , Coluna Vertebral/cirurgia , Estresse Mecânico , Resistência à Tração , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...