Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Rev Sci Instrum ; 83(9): 094301, 2012 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-23020395

RESUMO

We have developed a continuous-wave near-infrared imaging system to measure fast neuronal signals. We used a simultaneous sampling method with a separate high-speed analog-to-digital converter for each input channel, which provides a much larger point sample in a digital lock-in algorithm, higher temporal resolution, and lower crosstalk among detected channels. Without any analog filter, digital lock-in detection with a large point sample suppresses noise excellently, making the system less complex and offering better flexibility. In addition, using a custom-made collimator, more photons can reach the brain tissue due to the smaller divergence angle. Performance analysis shows high detection sensitivity (on the order of 0.1 pW) and high temporal resolution (~50 Hz, 48 channels). Simulation experiments show that intensity changes on the order of 0.01% can be resolved by our instrument when averaging over approximately 500 stimuli. In vivo experiments over the motor cortex show that our instrument can detect fast neuronal signals in the human brain.


Assuntos
Raios Infravermelhos , Imagem Molecular/instrumentação , Neurônios/citologia , Adulto , Braço/irrigação sanguínea , Arteriopatias Oclusivas/fisiopatologia , Humanos , Córtex Motor/citologia , Fatores de Tempo , Interface Usuário-Computador
2.
Eur J Appl Physiol ; 112(2): 567-78, 2012 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-21611824

RESUMO

To study the relationship between the local and systemic aerobic fitness parameters, and between the muscle oxygenation and aerobic performance, 16 female finswimmers were recruited and divided into high-level (HL) group and low-level group. Cardiorespiratory function, blood lactate concentration and near infrared spectroscopy muscle oxygenation in the vastus lateralis (VL) were monitored simultaneously during a maximal incremental exercise. We found that the break point (Bp) of the oxygenation index (OI) in the VL (BpVL) had significant correlations with lactate threshold (LT) and gas exchange threshold (GET), and the appearance sequence of the three thresholds was BpVL ≈ LT ≤ GET. When considering different levels, the [Formula: see text] at BpVL, LT and GET were higher in the HL group. During intensive exercise, there were significantly faster [Formula: see text] increase and evidently slower OI decrease in the HL group, suggesting that faster [Formula: see text] increase in the HL group slowed down the muscle deoxygenation and facilitated subjects to cycle to higher workloads. In conclusion, multi-modality approaches combining local and systemic physiological monitoring technologies might provide better explanations of the relationship between local and systemic aerobic fitness parameters, and might be a novel way to analyze the difference between groups of different levels.


Assuntos
Limiar Anaeróbio/fisiologia , Exercício Físico/fisiologia , Ácido Láctico/sangue , Músculo Esquelético/fisiologia , Consumo de Oxigênio/fisiologia , Aptidão Física/fisiologia , Natação/fisiologia , Feminino , Humanos , Adulto Jovem
3.
J Sports Sci Med ; 11(4): 606-13, 2012.
Artigo em Inglês | MEDLINE | ID: mdl-24150069

RESUMO

In recent years, breakpoints (Bp) of muscle oxygenation have been measured in local muscles using near infrared spectroscopy (NIRS) to assess (predict) systemic aerobic capacity indices [lactate threshold (LT), gas exchange threshold (GET) and maximal oxygen uptake (VO2peak)]. We investigated muscular differences in the assessment (predictive) ability of the Bp of muscle oxygenation for aerobic capacity indices during incremental cycling exercise on the aerobic capacity indices. Thirty-one active college students were recruited for an incremental cycling exercise test, during which NIRS muscle oxygenation in the vastus lateralis (VL) and gastrocnemius lateralis (GL), blood lactate concentration and cardiopulmonary variables were measured simultaneously in a multi-modality approach. A linear regression model was used to analyse the relationship between the Bp of the muscle oxygenation index (OI) and the systemic aerobic capacity indices. The Bp of the muscle OI in both the VL (BpVL) and GL (BpGL) were significantly correlated with the aerobic capacity indices. Additionally, the BpVL had a better goodness-of-fit [higher coefficient of determination (R(2), p < 0.001) and lower root mean squared error (RMSE, p < 0.03)] in the linear regressions and occurred earlier than the BpGL. In conclusion, both the BpVL and the BpGL could be measured by NIRS to assess the systemic aerobic capacity indices; however, there were muscular differences in the assessment ability of the Bp of muscle oxygenation.

4.
J Biomed Opt ; 15(1): 017007, 2010.
Artigo em Inglês | MEDLINE | ID: mdl-20210481

RESUMO

Our purpose is to compare the changes in muscle oxygenation in the vastus lateralis (VL) and biceps brachii (BB) muscles simultaneously using near-infrared spectroscopy (NIRS) during incremental rowing exercise in eight rowers. Based on the BB and VL muscle oxygenation patterns, two points are used to characterize the muscle oxygenation kinetics in both the arm and the leg muscles. The first point is the breaking point (Bp), which refers to an accelerated fall in muscle oxygenation that correlates with the gas exchange threshold (GET). The second point is the leveling-off point (Lo), which suggests the upper limit of O(2) extraction. The GET occurred at 63.3+/-2.4% of maximal oxygen uptake (VO(2 max)). The Bp appeared at 45.0+/-3.8% and 55.6+/-2.4% VO(2 max) in the BB and VL, respectively. The Lo appeared at 63.6+/-4.1% and 86.6+/-1.0% VO(2 max) in these two muscles, respectively. Both the Bp and the Lo occurred earlier in BB compared with VL. These results suggest that arm muscles have lower oxidative capacity than leg muscles during rowing exercise. The rowers with higher exercise performances showed heavier workloads, as evaluated by Bp and Lo. The monitoring of muscle oxygenation by NIRS in arm and leg muscles during rowing could be a useful guide for evaluation and training.


Assuntos
Exercício Físico/fisiologia , Músculo Esquelético/fisiologia , Oxigênio/metabolismo , Espectroscopia de Luz Próxima ao Infravermelho/métodos , Adolescente , Análise de Variância , Braço/fisiologia , Humanos , Masculino , Músculo Esquelético/metabolismo , Oxigênio/química , Músculo Quadríceps/metabolismo , Músculo Quadríceps/fisiologia , Esportes/fisiologia , Adulto Jovem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...